Aims. The aim of this study was to determine satisfaction rates after hip and knee arthroplasty in patients who did not respond to postoperative patient-reported outcome measures (PROMs), characteristics of non-responders, and contact preferences to maximize response rates. Methods. A prospective cohort study of patients planned to undergo
Aims. Access to joint replacement is being restricted for patients with comorbidities in a number of high-income countries. However, there is little evidence on the impact of comorbidities on outcomes. The purpose of this study was to determine the safety and effectiveness of hip and knee arthroplasty in patients with and without comorbidities. Methods. In total, 312,079
Aims. In countries with social healthcare systems, such as Canada, patients may experience long wait times and a decline in their health status prior to their operation. The aim of this study is to explore the association between long preoperative wait times (WT) and acute hospital length of stay (LoS) for primary arthroplasty of the knee and hip. Methods. The study population was obtained from the provincial Patient Access Registry Nova Scotia (PARNS) and the Canadian national hospital Discharge Access Database (DAD). We included primary total knee and
Aims. To investigate whether chronic kidney disease (CKD) is associated with the risk of all-cause revision or revision due to a periprosthetic joint infection (PJI) after primary hip or knee arthroplasty. Methods. This retrospective cohort study comprised 18,979 consecutive hip and knee arthroplasties from a single high-volume academic hospital. At a median of 5.6 years (interquartile range (IQR) 3.5 to 8.1), all deaths and revisions were counted. To overcome the competing risk of death, competing risk analysis using the cumulative incidence function (CIF) was applied to analyze the association between different stages of CKD and revisions. Confounding factors such as diabetes and BMI were considered using either a stratified CIF or the Fine and Gray model. Results. There were 2,111 deaths (11.1%) and 677 revisions (3.6%) during the follow-up period. PJI was the reason for revision in 162 cases (0.9%). For
This study aims to evaluate the impact of metabolic syndrome in the setting of obesity on in-hospital outcomes and resource use after total joint replacement (TJR). A retrospective analysis was conducted using the National Inpatient Sample from 2006 to the third quarter of 2015. Discharges representing patients aged 40 years and older with obesity (BMI > 30 kg/m2) who underwent primary TJR were included. Patients were stratified into two groups with and without metabolic syndrome. The inverse probability of treatment weighting (IPTW) method was used to balance covariates.Aims
Methods
Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT. TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90.Aims
Methods
Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by ‘reverse calibration’ of 20 radiographs taken three months after
Our aim was to estimate the total costs of all hospitalizations for treating periprosthetic joint infection (PJI) by main management strategy within 24 months post-diagnosis using activity-based costing. Additionally, we investigated the influence of individual PJI treatment pathways on hospital costs within the first 24 months. Using admission and procedure data from a prospective observational cohort in Australia and New Zealand, Australian Refined Diagnosis Related Groups were assigned to each admitted patient episode of care for activity-based costing estimates of 273 hip PJI patients and 377 knee PJI patients. Costs were aggregated at 24 months post-diagnosis, and are presented in Australian dollars.Aims
Methods
Day-case success rates after primary total hip arthroplasty (THA), total knee arthroplasty (TKA), and medial unicompartmental knee arthroplasty (mUKA) may vary, and detailed data are needed on causes of not being discharged. The aim of this study was to analyze the association between surgical procedure type and successful day-case surgery, and to analyze causes of not being discharged on the day of surgery when eligible and scheduled for day-case THA, TKA, and mUKA. A multicentre, prospective consecutive cohort study was carried out from September 2022 to August 2023. Patients were screened for day-case eligibility using well defined inclusion and exclusion criteria, and discharged when fulfilling predetermined discharge criteria. Day-case eligible patients were scheduled for surgery with intended start of surgery before 1.00 pm.Aims
Methods
The aim of this study was to evaluate the healthcare costs and benefits of enoxaparin compared to aspirin in the prevention of symptomatic venous thromboembolism (VTE) after total hip arthroplasty (THA) or total knee arthroplasty (TKA) using data from the CRISTAL trial. This trial-based economic analysis reports value for money as incremental cost per quality-adjusted life-year (QALY) gained in 2022 Australian dollars, compared to a single threshold value of AUD$70,000 per QALY. Event costs were estimated based on occurrence of VTEs and bleeds, and on published guidelines for treatment. Unit costs were taken from Australian sources. QALYs were estimated using CRISTAL six-month follow-up data. Sensitivity analyses are presented that vary the cost of VTE treatment, and extend the analyses to two years.Aims
Methods
We investigated 15 patients with painful
The EuroQol five-dimension (EQ-5D) questionnaire is a widely used multiattribute general health questionnaire where an EQ-5D < 0 defines a state ‘worse than death’ (WTD). The aim of this study was to determine the proportion of patients awaiting total hip arthroplasty (THA) or total knee arthroplasty (TKA) in a health state WTD and to identify associations with this state. Secondary aims were to examine the effect of WTD status on one-year outcomes. A cross-sectional analysis of 2073 patients undergoing 2073 THAs (mean age 67.4 years (Aims
Patients and Methods
Total knee arthroplasty (TKA) and total hip arthroplasty
(THA) are recognised and proven interventions for patients with
advanced arthritis. Studies to date have demonstrated a steady increase
in the requirement for primary and revision procedures. Projected
estimates made for the United States show that by 2030 the demand
for primary TKA will grow by 673% and for revision TKA by 601% from
the level in 2005. For THA the projected estimates are 174% and
137% for primary and revision surgery, respectively. The purpose
of this study was to see if those predictions were similar for England
and Wales using data from the National Joint Registry and the Office
of National Statistics. Analysis of data for England and Wales suggest that by 2030,
the volume of primary and revision TKAs will have increased by 117%
and 332%, respectively between 2012 and 2030. The data for the United
States translates to a 306% cumulative rate of increase between
2012 and 2030 for revision surgery, which is similar to our predictions
for England and Wales. The predictions from the United States for primary TKA were similar
to our upper limit projections. For THA, we predicted an increase
of 134% and 31% for primary and revision hip surgery, respectively. Our model has limitations, however, it highlights the economic
burden of arthroplasty in the future in England and Wales as a real
and unaddressed problem. This will have significant implications
for the provision of health care and the management of orthopaedic
services in the future. Cite this article:
Wear debris released from bearing surfaces has been shown to
provoke negative immune responses in the recipient. Excessive wear
has been linked to early failure of prostheses. Analysis using coordinate
measuring machines (CMMs) can provide estimates of total volumetric
material loss of explanted prostheses and can help to understand
device failure. The accuracy of volumetric testing has been debated,
with some investigators stating that only protocols involving hundreds
of thousands of measurement points are sufficient. We looked to
examine this assumption and to apply the findings to the clinical
arena. We examined the effects on the calculated material loss from
a ceramic femoral head when different CMM scanning parameters were
used. Calculated wear volumes were compared with gold standard gravimetric
tests in a blinded study. Objectives
Methods
To evaluate the effectiveness of an institutionally developed
algorithm for evaluation and diagnosis of prosthetic joint injection
and to determine the impact of this protocol on overall hospital
re-admissions.p We retrospectively evaluated 2685 total hip arthroplasty (THA)
and total knee arthroplasty (TKA) patients prior to (1263) and following
(1422) the introduction of an infection detection protocol. The
protocol used conservative thresholds for C-reactive protein to
direct the medical attendant to aspirate the joint. The protocol
incorporated a clear set of laboratory and clinical criteria that
allowed a patient to be discharged home if all were met. Patients were
included if they presented to our emergency department within 120
days post-operatively with concerns for swelling, pain or infection
and were excluded if they had an unambiguous infection or if their
chief complaint was non-orthopaedic in nature.Aims
Patients and Methods
The newer techniques of cementing aim to improve interlock between cement and bone around a femoral stem by combining high pressure and reduced viscosity. This may produce increased embolisation of fat and marrow leading to hypotension, impaired pulmonary gas exchange and death. For this reason the use of high pressures has been questioned. We compared finger-packing with the use of a cement gun by measuring intramedullary pressures during the cementing of 31 total hip replacements and measuring physiological changes in 19 patients. We also measured pressure in more detail in a laboratory model. In the clinical series the higher pressures were produced by using a gun, but this caused less physiological disturbance than finger-packing. The laboratory studies showed more consistent results with the gun technique, but for both methods of cementing the highest pressures were generated during the insertion of the stem of the prosthesis.
Surgical site infection (SSI) is a common complication of surgery
with an incidence of about 1% in the United Kingdom. Sutures can
lead to the development of a SSI, as micro-organisms can colonize
the suture as it is implanted. Triclosan-coated sutures, being antimicrobical,
were developed to reduce the rate of SSI. Our aim was to assess
whether triclosan-coated sutures cause a reduction in SSIs following
arthroplasty of the hip and knee. This two-arm, parallel, double-blinded study involved 2546 patients
undergoing elective total hip (THA) and total knee arthroplasty
(TKA) at three hospitals. A total of 1323 were quasi-randomized
to a standard suture group, and 1223 being quasi-randomized to the
triclosan-coated suture group. The primary endpoint was the rate
of SSI at 30 days postoperatively.Aims
Patients and Methods
The interaction between surgical lighting and laminar airflow
is poorly understood. We undertook an experiment to identify any
effect contemporary surgical lights have on laminar flow and recommend
practical strategies to limit any negative effects. Neutrally buoyant bubbles were introduced into the surgical field
of a simulated setup for a routine total knee arthroplasty in a
laminar flow theatre. Patterns of airflow were observed and the
number of bubbles remaining above the surgical field over time identified.
Five different lighting configurations were assessed. Data were analysed
using simple linear regression after logarithmic transformation.Aims
Materials and Methods
Aims. A substantial fraction of patients undergoing knee arthroplasty (KA) or
Aims. To calculate how the likelihood of obtaining measurable benefit from hip or knee arthroplasty varies with preoperative patient-reported scores. Methods. Existing UK data from 222,933 knee and 209,760