Advertisement for orthosearch.org.uk
Results 1 - 50 of 342
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 649 - 653
1 Jul 1995
Bohm P Stihler J

One method of reconstruction in limb salvage surgery for bone tumours is wide resection, extracorporeal devitalisation of the excised segment by autoclaving, and reimplantation of the segment. We have studied the changes in temperature in the medullary cavity, the head, the medial condyle and lateral condyle of calf femora during autoclaving at 134 degrees C in two different autoclaves. There were impressive differences of temperature at different sites. The most unfavourable position was the lateral condyle, which consists mainly of cancellous bone: a short programme of 11 minutes produced a lowest temperature in the series of only 45 degrees C, which may not be sufficient to kill all tumour cells


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 137 - 140
1 Jan 2002
Piska M Yang L Reed M Saleh M

An innovative Kirschner (K-) wire point was developed and compared in fresh pig femora in terms of drilling efficiency and temperature elevation with the trochar and diamond points currently used in clinical practice. The tips of thermal couples were machined to the defined geometry and the temperature measured during drilling. Using the same drill speed (rev/min) and feed rate, the new K-wire point produced the lowest thrust force and torque as measured by a Kistler dynamometer. Drill point temperatures were highest with the trochar geometry (129 ± 6°C), followed by the diamond (98 ± 7°C). The lowest temperatures were recorded with the Medin K-wire (66 ± 2°C). On repeated drilling it could be used for up to 30 holes before reaching the less satisfactory drill performance of the diamond tip. The new K-wire provides a better alternative as it requires less effort for insertion, generates less heat and may be re-used


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 342 - 344
1 Mar 1999
Hamer AJ Stockley I Elson RA

Secondary sterilisation of allograft bone by gamma irradiation is common, but the conditions under which it is performed vary between tissue banks. Some do so at room temperature, others while the bone is frozen. Bone is made brittle by irradiation because of the destruction of collagen alpha chains, probably mediated by free radicals generated from water molecules. Freezing reduces the mobility of water molecules and may therefore decrease the production of free radicals. We found that bone irradiated at −78°C was less brittle and had less collagen damage than when irradiated at room temperature. These findings may have implications for bone-banking


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 102 - 103
1 Feb 1980
Mostafa A El Attar S Mili F Wright E

The effect of the environmental temperature on the healing of fractures was assessed in vertebrae of tails of young albino mice. It was found that fractures in animals kept at 33 degrees Celsius healed very rapidly (bony callus by 14 days) while in animals kept in the cold (8 degrees Celsius) fractures were still at the stage of granulation tissue at this time. Controls were at an intermediate stage. This result might have a clinical application


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 1 | Pages 110 - 113
1 Feb 1962
Pledger HG

1. A patient is described who developed hypothermia shortly after being rendered tetraplegic by a fracture of the cervical spine.

2. The causes and prevention of hypothermia or hyperpyrexia in tetraplegia are discussed.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 231 - 238
1 Mar 2023
Holme TJ Crate G Trompeter AJ Monsell FP Bridgens A Gelfer Y

Aims. The ‘pink, pulseless hand’ is often used to describe the clinical situation in which a child with a supracondylar fracture of the humerus has normal distal perfusion in the absence of a palpable peripheral pulse. The management guidelines are based on the assessment of perfusion, which is difficult to undertake and poorly evaluated objectively. The aim of this study was to review the available literature in order to explore the techniques available for the preoperative clinical assessment of perfusion in these patients and to evaluate the clinical implications. Methods. A systematic literature review was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and registered prospectively with the International Prospective Register of Systematic Reviews. Databases were explored in June 2022 with the search terms (pulseless OR dysvascular OR ischaemic OR perfused OR vascular injury) AND supracondylar AND (fracture OR fractures). Results. A total of 573 papers were identified as being suitable for further study, and 25 met the inclusion criteria for detailed analysis. These studies included a total of 504 patients with a perfused, pulseless limb associated with a supracondylar humeral fracture. Clinical examination included skin colour (23 studies (92%)), temperature (16 studies (64%)), and capillary refill time (13 studies (52%)). Other investigations included peripheral oxygen saturation (SaO2) (six studies (24%)), ultrasound (US) (14 (56%)), and CT angiogram (two studies (8.0%)). The parameters of ‘normal perfusion’ were often not objectively defined. The time to surgery ranged from 1.5 to 12 hours. A total of 412 patients (82%) were definitively treated with closed or open reduction and fixation, and 92 (18%) required vascular intervention, ranging from simple release of entrapped vessels to vascular grafts. Conclusion. The description of the vascular assessment of the patient with a supracondylar humeral fracture and a pulseless limb in the literature is variable, with few objective criteria being used to define perfusion. The evidence base for decision-making is limited, and further research is required. We were able, however, to make some recommendations about objective criteria for the assessment of these patients, and we suggest that these are performed frequently to allow the detection of any deterioration of perfusion. Cite this article: Bone Joint J 2023;105-B(3):231–238


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 554 - 560
1 Apr 2017
Tamai K Suzuki A Takahashi S Akhgar J Rahmani MS Hayashi K Ohyama S Nakamura H

Aims. We aimed to evaluate the temperature around the nerve root during drilling of the lamina and to determine whether irrigation during drilling can reduce the chance of nerve root injury. Materials and Methods. Lumbar nerve roots were exposed to frictional heat by high-speed drilling of the lamina in a live rabbit model, with saline (room temperature (RT) or chilled saline) or without saline (control) irrigation. We measured temperatures surrounding the nerve root and made histological evaluations. Results. In the control group, the mean temperature around the nerve root was 52.0°C (38.0°C to 75.5°C) after 60 seconds of drilling, and nerve root injuries were found in one out of 13 (7.7%) immediately, three out of 14 (21.4%) at three days, and 11 out of 25 (44.0%) at seven days post-operatively. While the RT group showed a significantly lower temperature around the nerve root compared with the control group (mean 46.5°C; 34.5°C to 66.9°C, p < 0.001), RT saline failed to significantly reduce the incidence of nerve root injury (ten out of 26; 38.5%; odds ratio (OR) 0.96; 95% confidence interval (CI) 0.516 to 1.785; p = 0.563). However, chilled saline irrigation resulted in a significantly lower temperature than the control group (mean 39.0°C; 35.3°C to 52.3°C; p < 0.001) and a lower rate of nerve root injury (two out of 21; 9.5%, OR 0.13; 95% CI 0.02 to 0.703, p = 0.010). Conclusion. Frictional heat caused by a high-speed drill can cause histological nerve root injury. Chilled saline irrigation had a more prominent effect than RT in reducing the incidence of the thermal injury during extended drilling. Cite this article: Bone Joint J 2017;99-B:554–60


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1273 - 1283
1 Nov 2024
Mahmud H Wang D Topan-Rat A Bull AMJ Heinrichs CH Reilly P Emery R Amis AA Hansen UN

Aims. The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids. Methods. Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage. Results. At the completion of the wear test, the total thickness of the cartilage had significantly decreased in both the ceramic and metal groups, by 27% (p = 0.019) and 29% (p = 0.008), respectively. However, the differences between the two were not significant (p = 0.606) and the patterns of wear in the specimens were unpredictable. No significant correlation was found between cartilage wear and various factors, including age, sex, the size of the humeral head, joint mismatch, the thickness of the native cartilage, and the surface roughness (all p > 0.05). Conclusion. Although ceramic has better tribological properties than metal, we did not find evidence that its use in hemiarthroplasty of the shoulder in patients with healthy cartilage is a better alternative than conventional metal humeral heads. Cite this article: Bone Joint J 2024;106-B(11):1273–1283


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 677 - 683
1 May 2014
Greenberg A Berenstein Weyel T Sosna J Applbaum J Peyser A

Osteoid osteoma is treated primarily by radiofrequency (RF) ablation. However, there is little information about the distribution of heat in bone during the procedure and its safety. We constructed a model of osteoid osteoma to assess the distribution of heat in bone and to define the margins of safety for ablation. Cavities were drilled in cadaver bovine bones and filled with a liver homogenate to simulate the tumour matrix. Temperature-sensing probes were placed in the bone in a radial fashion away from the cavities. RF ablation was performed 107 times in tumours < 10 mm in diameter (72 of which were in cortical bone, 35 in cancellous bone), and 41 times in cortical bone with models > 10 mm in diameter. Significantly higher temperatures were found in cancellous bone than in cortical bone (p <  0.05). For lesions up to 10 mm in diameter, in both bone types, the temperature varied directly with the size of the tumour (p < 0.05), and inversely with the distance from it. Tumours of > 10 mm in diameter showed a trend similar to those of smaller lesions. No temperature rise was seen beyond 12 mm from the edge of a cortical tumour of any size. Formulae were developed to predict the expected temperature in the bone during ablation. Cite this article: Bone Joint J 2014; 96-B:677–83


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 16 - 20
1 Jan 2007
Gill HS Campbell PA Murray DW De Smet KA

Resurfacing arthroplasty of the hip is being used increasingly as an alternative to total hip replacement, especially for young active patients. There is concern about necrosis of the femoral head after resurfacing which can result in fracture and loosening. Most systems use a cemented femoral component, with the potential for thermal necrosis of the cancellous bone of the reamed femoral head. We used thermal probes to record temperatures close to the cement-bone interface during resurfacing arthroplasty. The maximum temperature recorded at the cement-bone interface in four cases was approximately 68°C which was higher than that reported to kill osteocytes. A modified surgical technique using insertion of a suction cannula into the lesser trochanter, generous pulsed lavage and early reduction of the joint significantly reduced the maximum recorded cancellous bone temperature to approximately 36°C in five cases (p = 0.014). We recommend the modified technique since it significantly reduces temperatures at the cement-bone interface


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 454 - 460
1 Mar 2010
Baleani M Bialoblocka-Juszczyk E Engels GE Viceconti M

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue tests, and were examined for porosity. Pre-heating the stem alone significantly increased the mean temperature values measured within the mantle (+14.2°C) (p < 0.001) and reduced the mean curing time (−1.5 min) (p < 0.001). The addition of vacuum mixing modulated the mean rise in the temperature of polymerisation to 11°C and reduced the mean duration of the process by one minute and 50 seconds (p = 0.01 and p < 0.001, respectively). In all cases, the maximum temperature values measured in the mould simulating the femur were < 50°C. The mixing technique and pre-heating the stem slightly increased the static mechanical strength of bone cement. However, the fatigue life of the cement was improved by both vacuum mixing and pre-heating the stem, but was most marked (+ 280°C) when these methods were combined. Pre-heating the stem appears to be an effective way of improving the quality of the cement mantle, which might enhance the long-term performance of bone cement, especially when combined with vacuum mixing


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 113 - 122
1 Jan 2021
Kayani B Tahmassebi J Ayuob A Konan S Oussedik S Haddad FS

Aims. The primary aim of this study was to compare the postoperative systemic inflammatory response in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic-arm assisted total knee arthroplasty (robotic TKA). Secondary aims were to compare the macroscopic soft tissue injury, femoral and tibial bone trauma, localized thermal response, and the accuracy of component positioning between the two treatment groups. Methods. This prospective randomized controlled trial included 30 patients with osteoarthritis of the knee undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localized knee temperature were collected preoperatively and postoperatively at six hours, day 1, day 2, day 7, and day 28 following TKA. Blinded observers used the Macroscopic Soft Tissue Injury (MASTI) classification system to grade intraoperative periarticular soft tissue injury and bone trauma. Plain radiographs were used to assess the accuracy of achieving the planned postioning of the components in both groups. Results. Patients undergoing conventional TKA and robotic TKA had comparable changes in the postoperative systemic inflammatory and localized thermal response at six hours, day 1, day 2, and day 28 after surgery. Robotic TKA had significantly reduced levels of interleukin-6 (p < 0.001), tumour necrosis factor-α (p = 0.021), ESR (p = 0.001), CRP (p = 0.004), lactate dehydrogenase (p = 0.007), and creatine kinase (p = 0.004) at day 7 after surgery compared with conventional TKA. Robotic TKA was associated with significantly improved preservation of the periarticular soft tissue envelope (p < 0.001), and reduced femoral (p = 0.012) and tibial (p = 0.023) bone trauma compared with conventional TKA. Robotic TKA significantly improved the accuracy of achieving the planned limb alignment (p < 0.001), femoral component positioning (p < 0.001), and tibial component positioning (p < 0.001) compared with conventional TKA. Conclusion. Robotic TKA was associated with a transient reduction in the early (day 7) postoperative inflammatory response but there was no difference in the immediate (< 48 hours) or late (day 28) postoperative systemic inflammatory response compared with conventional TKA. Robotic TKA was associated with decreased iatrogenic periarticular soft tissue injury, reduced femoral and tibial bone trauma, and improved accuracy of component positioning compared with conventional TKA. Cite this article: Bone Joint J 2021;103-B(1):113–122


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1541 - 1544
1 Nov 2009
Hosono N Miwa T Mukai Y Takenaka S Makino T Fuji T

Using the transverse processes of fresh porcine lumbar spines as an experimental model we evaluated the heat generated by a rotating burr of a high-speed drill in cutting the bone. The temperature at the drilled site reached 174°C with a diamond burr and 77°C with a steel burr. With water irrigation at a flow rate of 540 ml/hr an effective reduction in the temperature was achieved whereas irrigation with water at 180 ml/hr was much less effective. There was a significant negative correlation between the thickness of the residual bone and the temperature measured at its undersurface adjacent to the drilling site (p < 0.001). Our data suggest that tissues neighbouring the drilled bone, especially nerve roots, can be damaged by the heat generated from the tip of a high-speed drill. Nerve-root palsy, one of the most common complications of cervical spinal surgery, may be caused by thermal damage to nerve roots arising in this manner


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 933 - 939
1 Jul 2007
Ya’ish F Cooper JP Craigen MAC

The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury, comparison was made against the unaffected nerve distribution in the same hand. Receiver operating characteristic curve analysis showed that an absolute temperature difference ≥ 1.0°C was diagnostic of a nerve injury (area under the curve = 0.985, sensitivity = 100%, specificity = 93.8%). Thermotropic liquid crystal strip assessment is a new, reliable and objective method for the diagnosis of traumatic peripheral nerve injuries. If implemented in the acute setting, it could improve the reliability of clinical assessment and reduce the number of negative surgical explorations


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 117 - 124
1 Jan 2016
Takenaka S Hosono N Mukai Y Tateishi K Fuji T

Aims. The aim of this study was to determine whether chilled irrigation saline decreases the incidence of clinical upper limb palsy (ULP; a reduction of one grade or more on manual muscle testing; MMT), based on the idea that ULP results from thermal damage to the nerve roots by heat generated by friction during bone drilling. Methods. Irrigation saline for drilling was used at room temperature (RT, 25.6°C) in open-door laminoplasty in 400 patients (RT group) and chilled to a mean temperature of 12.1°C during operations for 400 patients (low-temperature (LT) group). We assessed deltoid, biceps, and triceps brachii muscle strength by MMT. ULP occurring within two days post-operatively was categorised as early-onset palsy. Results. The incidence of ULP (4.0% vs 9.5%, p = 0.003), especially early-onset palsy (1.0% vs 5.5%, p < 0.001), was significantly lower for the LT group than for the RT group. Multivariate analysis indicated that RT irrigation saline use, concomitant foraminotomy, and opened side were significant predictors for ULP. Discussion. Using chilled irrigation saline during bone drilling significantly decreased the ULP incidence, particularly the early-onset type, and shortened the recovery period for ULP. Chilled irrigation saline can thus be recommended as a simple method for preventing ULP. Take home message: Chilled irrigation during laminoplasty reduces C5 palsy. Cite this article: Bone Joint J 2016;98-B:117–24


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 407 - 410
1 Mar 2013
Legg AJ Hamer AJ

We have recently shown that waste heat from forced-air warming blankets can increase the temperature and concentration of airborne particles over the surgical site. The mechanism for the increased concentration of particles and their site of origin remained unclear. We therefore attempted to visualise the airflow in theatre over a simulated total knee replacement using neutral-buoyancy helium bubbles. Particles were created using a Rocket PS23 smoke machine positioned below the operating table, a potential area of contamination. The same theatre set-up, warming devices and controls were used as in our previous study. This demonstrated that waste heat from the poorly insulated forced-air warming blanket increased the air temperature on the surgical side of the drape by > 5°C. This created convection currents that rose against the downward unidirectional airflow, causing turbulence over the patient. The convection currents increased the particle concentration 1000-fold (2 174 000 particles/m. 3. for forced-air warming vs 1000 particles/m. 3. for radiant warming and 2000 particles/m. 3. for the control) by drawing potentially contaminated particles from below the operating table into the surgical site. Cite this article: Bone Joint J 2013;95-B:407–10


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 492 - 496
1 May 2002
Giannoudis PV Snowden S Matthews SJ Smye SW Smith RM

We have carried out a prospective, randomised trial to measure the rise of temperature during reaming of the tibia before intramedullary nailing. We studied 34 patients with a mean age of 35.1 years (18 to 63) and mean injury severity score of 10 (9 to 13). The patients were randomised into two groups: group 1 included 18 patients whose procedure was undertaken without a tourniquet and group 2, 16 patients in whom a tourniquet was used. The temperature in the bone was measured directly by two thermocouples inserted into the cortical bone near the isthmus of the tibial diaphysis. Reaming was carried out to at least 1.5 mm above the required diameter of the nail. Blood loss was assessed by recording the preoperative and postoperative haemoglobin (Hb) level. The minimum clinical follow-up was six months. In group 1 (no tourniquet), the mean Hb dropped 2.8 g/dl from 14.3 ± 1.02 g/dl to 11.5 ± 1.04 g/dl (p = 0.0001), whereas with the tourniquet, the mean decrease was 1.3 g/dl from 14 ± 1 g/dl to 12.7 ± 1.3 g/dl (p = 0.007). This difference was not statistically significant. The mean initial tibial temperature was 35.6°C (. sd. 0.6) and rose with reaming to levels between 36.3°C and 51.6°C. The highest temperatures were obtained with the largest reamers (11 and 12 mm, p = 0.0001) and the most rapid rise with the smallest diameters of medullary canal (8 or 9 mm). The rise of temperature was transient (20s). We were unable to identify any effect of the use of a tourniquet on the temperature achieved. Reamed intramedullary tibial nailing induces a transient elevation of temperature which is directly related to the amount of reaming


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1298 - 1302
1 Sep 2005
Iesaka K Jaffe WL Jones CM Kummer FJ

We have investigated the role of the penetration of saline on the shear strength of the cement-stem interface for stems inserted at room temperature and those preheated to 37°C using a variety of commercial bone cements. Immersion in saline for two weeks at 37°C reduced interfacial strength by 56% to 88% after insertion at room temperature and by 28% to 49% after preheating of the stem. The reduction in porosity as a result of preheating ranged from 71% to 100%. Increased porosity correlated with a reduction in shear strength after immersion in saline (r = 0.839, p < 0.01) indicating that interfacial porosity may act as a fluid conduit


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1478 - 1481
1 Nov 2007
Aono H Ohwada T Kaneko N Fuji T Iwasaki M

Inflammatory markers such as the C-reactive protein (CRP), white blood cell count and body temperature are easy to measure and are used as indicators of infection. The way in which they change in the early post-operative period after instrumented spinal surgery has not been reported in any depth. We measured these markers pre-operatively and at one, four, seven and 14 days postoperatively in 143 patients who had undergone an instrumented posterior lumbar interbody fusion. The CRP proved to be the only sensitive marker and had returned to its normal level in 48% of patients after 14 days. The CRP on day 7 was never higher than that on day 4. Age, gender, body temperature, operating time and blood loss were not related to the CRP level. A high CRP does not in itself suggest infection, but any increase after four days may presage infection


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1065 - 1070
1 Aug 2011
Tanavalee A Honsawek S Rojpornpradit T Sakdinakiattikoon M Ngarmukos S

We compared inflammation in the knee after total knee replacement (TKR) for primary osteoarthritis between two groups of patients undergoing joint replacement with and without synovectomy. A total of 67 patients who underwent unilateral TKR were randomly divided into group I, TKR without synovectomy, and group II, TKR with synovectomy. Clinical outcomes, serial serum inflammatory markers (including interleukin-6 (IL-6), CRP and ESR) and the difference in temperature of the skin of the knee, compared with the contralateral side, were sequentially evaluated until 26 weeks after surgery. Pre-operatively, there were no statistically different clinical parameters between groups I and II. At the 26-week follow-up, both groups had a similarly significantly improved American Knee Society clinical score (p < 0.001) and functional score (p < 0.001) with no differences between the groups. Similar changes in serial inflammatory markers were found in both groups, including mean peak levels of IL-6 (189 pg/ml (. sd. 53.4) versus 201 pg/ml (. sd. 49.4) for groups I and II, respectively) and CRP (91 mg/L (. sd. 24.1) versus 88 mg/L (. sd. 23.4), respectively) on the first post-operative day, returning to pre-operative values at two and six weeks, respectively. The mean peak level of ESR for the respective two groups was 46 mm/hr versus 48 mm/hr at two weeks, which had still not returned to its pre-operative mean value at 26 weeks. The elevation in the skin temperature appeared to mirror the peak elevation of the ESR, with a range of 2.5° C to 4.5° C with some reduction at 26 weeks but still exceeding the pre-operative value. We concluded that synovectomy at the time of TKR does not provide any benefit to the clinical outcome or shorten the duration of the inflammatory response after surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 511 - 518
1 Nov 1975
Jefferiss CD Lee AJC Ling RSM

Bone necrosis adjacent to self-curing polymethylmethacrylate is a matter of accepted fact. Among the possible causes are mechanical and vascular damage from the preparation of the bone cavity, chemical damage from the monomer and free radicals in the cement dough, and thermal damage from the heat of polymerisation, occurring in this order. Consideration of the tissue reaction to this material, theoretical calculation of the heat output from polymerising acrylic and interface temperature proffiles, experimental observations of interface temperatures and maximal temperatures at polymerisation, together with clinical observations, all lead to the view that the bone necrosis is not a consequence of thermal damage, which is unlikely to be a cause of failure of prosthetic fixation. Temperatures recorded from within polymerising acrylic masses are related primarily to the amount of monomer polymerising and are of no clinical significance in the fixation of prostheses. Interface temperatures are related primarily to the surface area of the interface and the thermal characteristics of the cooler material


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 349 - 356
1 May 1996
Bishop NE Ferguson S Tepic S

The fatigue failure of bone cement, leading to loosening of the stem, is likely to be one mode of failure of cemented total hip replacements. There is strong evidence that cracks in the cement are initiated at voids which act as stress risers, particularly at the cement-stem interface. The preferential formation of voids at this site results from shrinkage during polymerisation and the initiation of this process at the warmer cement-bone interface, which causes bone cement to shrink away from the stem. A reversal of the direction of polymerisation would shrink the cement on to the stem and reduce or eliminate the formation of voids at this interface. We have investigated this by implanting hip prostheses, at room temperature or preheated to 44°C, into human cadaver femora kept at 37°C. Two types of bone cement were either hand-mixed or vacuum-mixed before implantation. We found that the area of porosity at the cement-stem interface was dramatically reduced by preheating the stem and that the preheating temperature of 44°C determined by computer analysis of transient heat transfer was the minimum required to induce initial polymerisation at the cement-stem interface. Temperature measurements taken during these experiments in vitro showed that preheating of the stem caused a negligible increase in the temperature of the bone. Reduction of porosity at the cement-stem interface could significantly increase the life of hip arthroplasties


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1214 - 1219
1 Nov 2004
Jafri AA Green SM Partington PF McCaskie AW Muller SD

Fatigue fractures which originate at stress-concentrating voids located at the implant-cement interface are a potential cause of septic loosening of cemented femoral components. Heating of the component to 44°C is known to reduce the porosity of the cement-prosthesis interface. The temperature of the cement-bone interface was recorded intra-operatively as 32.3°C. A simulated femoral model was devised to study the effect of heating of the component on the implant-cement interface. Heating of the implant and vacuum mixing have a synergistic effect on the porosity of the implant-cement interface, and heating also reverses the gradients of microhardness in the mantle. Heating of the implant also reduces porosity at the interface depending on the temperature. A minimum difference in temperature between the implant and the bone of 3°C was required to produce this effect. The optimal difference was 7°C, representing a balance between maximal reduction of porosity and an increased risk of thermal injury. Using contemporary cementing techniques, heating the implant to 40°C is recommended to produce an optimum effect


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 115 - 120
1 Jul 2019
Hooper J Schwarzkopf R Fernandez E Buckland A Werner J Einhorn T Walker PS

Aims. This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Materials and Methods. Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced. Results. Before and after steam sterilization, dimensional analysis showed that acrylonitrile butadiene styrene could not withstand the temperatures without dimensional changes. Oscillating saw tests with slotted cutting blocks produced debris, fractures, or further dimensional changes in the shape of Nylon-12 and polymethylmethacrylate (MED610), but polyetherimide ULTEM 1010 was least affected. Conclusion. The study showed that 3D-printed instrumentation was technically feasible and had some advantages. However, other factors, such as whether all procedural steps can be accomplished with a set of 3D-printed instruments, the logistics of delivery, and the economic aspects, require further study. Cite this article: Bone Joint J 2019;101-B(7 Supple C):115–120


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1021 - 1030
1 Sep 2024
Oto J Herranz R Fuertes M Plana E Verger P Baixauli F Amaya JV Medina P

Aims

Bacterial infection activates neutrophils to release neutrophil extracellular traps (NETs) in bacterial biofilms of periprosthetic joint infections (PJIs). The aim of this study was to evaluate the increase in NET activation and release (NETosis) and haemostasis markers in the plasma of patients with PJI, to evaluate whether such plasma induces the activation of neutrophils, to ascertain whether increased NETosis is also mediated by reduced DNaseI activity, to explore novel therapeutic interventions for NETosis in PJI in vitro, and to evaluate the potential diagnostic use of these markers.

Methods

We prospectively recruited 107 patients in the preoperative period of prosthetic surgery, 71 with a suspicion of PJI and 36 who underwent arthroplasty for non-septic indications as controls, and obtained citrated plasma. PJI was confirmed in 50 patients. We measured NET markers, inflammation markers, DNaseI activity, haemostatic markers, and the thrombin generation test (TGT). We analyzed the ability of plasma from confirmed PJI and controls to induce NETosis and to degrade in vitro-generated NETs, and explored the therapeutic restoration of the impairment to degrade NETs of PJI plasma with recombinant human DNaseI. Finally, we assessed the contribution of these markers to the diagnosis of PJI.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 227 - 229
1 Mar 2023
Theologis T Brady MA Hartshorn S Faust SN Offiah AC

Acute bone and joint infections in children are serious, and misdiagnosis can threaten limb and life. Most young children who present acutely with pain, limping, and/or loss of function have transient synovitis, which will resolve spontaneously within a few days. A minority will have a bone or joint infection. Clinicians are faced with a diagnostic challenge: children with transient synovitis can safely be sent home, but children with bone and joint infection require urgent treatment to avoid complications. Clinicians often respond to this challenge by using a series of rudimentary decision support tools, based on clinical, haematological, and biochemical parameters, to differentiate childhood osteoarticular infection from other diagnoses. However, these tools were developed without methodological expertise in diagnostic accuracy and do not consider the importance of imaging (ultrasound scan and MRI). There is wide variation in clinical practice with regard to the indications, choice, sequence, and timing of imaging. This variation is most likely due to the lack of evidence concerning the role of imaging in acute bone and joint infection in children. We describe the first steps of a large UK multicentre study, funded by the National Institute for Health Research, which seeks to integrate definitively the role of imaging into a decision support tool, developed with the assistance of individuals with expertise in the development of clinical prediction tools.

Cite this article: Bone Joint J 2023;105-B(3):227–229.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 59 - 66
1 Mar 2024
Karunaseelan KJ Nasser R Jeffers JRT Cobb JP

Aims

Surgical approaches that claim to be minimally invasive, such as the direct anterior approach (DAA), are reported to have a clinical advantage, but are technically challenging and may create more injury to the soft-tissues during joint exposure. Our aim was to quantify the effect of soft-tissue releases on the joint torque and femoral mobility during joint exposure for hip resurfacing performed via the DAA.

Methods

Nine fresh-frozen hip joints from five pelvis to mid-tibia cadaveric specimens were approached using the DAA. A custom fixture consisting of a six-axis force/torque sensor and motion sensor was attached to tibial diaphysis to measure manually applied torques and joint angles by the surgeon. Following dislocation, the torques generated to visualize the acetabulum and proximal femur were assessed after sequential release of the joint capsule and short external rotators.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 254 - 256
1 Feb 2012
Legg AJ Cannon T Hamer AJ

Patient warming significantly decreases the risk of surgical site infection. Recently there have been concerns that forced air warming may interfere with unidirectional airflow, potentially posing an increased risk of infection. Our null hypothesis was that forced air and radiant warming devices do not increase the temperature and the number of particles over the surgical site when compared with no warming device. A forced air warming device was compared with a radiant warming device and no warming device as a control. The temperature and number of particles were measured over the surgical site. The theatre was prepared as for a routine lower-limb arthroplasty operation, and the same volunteer was used throughout the study. Forced air warming resulted in a significant mean increase in the temperature (1.1°C vs 0.4°C, p < 0.0001) and number of particles (1038.2 vs 274.8, p = 0.0087) over the surgical site when compared with radiant warming, which raises concern as bacteria are known to require particles for transport


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 815 - 820
1 Jul 2023
Mitchell PD Abraham A Carpenter C Henman PD Mavrotas J McCaul J Sanghrajka A Theologis T

Aims

The aim of this study was to determine the consensus best practice approach for the investigation and management of children (aged 0 to 15 years) in the UK with musculoskeletal infection (including septic arthritis, osteomyelitis, pyomyositis, tenosynovitis, fasciitis, and discitis). This consensus can then be used to ensure consistent, safe care for children in UK hospitals and those elsewhere with similar healthcare systems.

Methods

A Delphi approach was used to determine consensus in three core aspects of care: 1) assessment, investigation, and diagnosis; 2) treatment; and 3) service, pathways, and networks. A steering group of paediatric orthopaedic surgeons created statements which were then evaluated through a two-round Delphi survey sent to all members of the British Society for Children’s Orthopaedic Surgery (BSCOS). Statements were only included (‘consensus in’) in the final agreed consensus if at least 75% of respondents scored the statement as critical for inclusion. Statements were discarded (‘consensus out’) if at least 75% of respondents scored them as not important for inclusion. Reporting these results followed the Appraisal Guidelines for Research and Evaluation.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 516 - 521
1 Jun 2024
Al-Hourani K Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims

Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI.

Methods

The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 261 - 268
1 Mar 2023
Ruhr M Huber G Niki Y Lohner L Ondruschka B Morlock MM

Aims

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure.

Methods

Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 373 - 381
15 Mar 2023
Jandl NM Kleiss S Mussawy H Beil FT Hubert J Rolvien T

Aims

The aim of this study was to evaluate the diagnostic accuracy of the absolute synovial polymorphonuclear neutrophil cell (PMN) count for the diagnosis or exclusion of periprosthetic joint infection (PJI) after total hip (THA) or knee arthroplasty (TKA).

Methods

In this retrospective cohort study, 147 consecutive patients with acute or chronic complaints following THA and TKA were included. Diagnosis of PJI was established based on the 2018 International Consensus Meeting criteria. A total of 39 patients diagnosed with PJI (32 chronic and seven acute) and 108 patients with aseptic complications were surgically revised.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 833 - 843
1 Jul 2022
Kayani B Baawa-Ameyaw J Fontalis A Tahmassebi J Wardle N Middleton R Stephen A Hutchinson J Haddad FS

Aims

This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA).

Methods

Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 347 - 355
15 Mar 2023
Birch NC Cheung JPY Takenaka S El Masri WS

Initial treatment of traumatic spinal cord injury remains as controversial in 2023 as it was in the early 19th century, when Sir Astley Cooper and Sir Charles Bell debated the merits or otherwise of surgery to relieve cord compression. There has been a lack of high-class evidence for early surgery, despite which expeditious intervention has become the surgical norm. This evidence deficit has been progressively addressed in the last decade and more modern statistical methods have been used to clarify some of the issues, which is demonstrated by the results of the SCI-POEM trial. However, there has never been a properly conducted trial of surgery versus active conservative care. As a result, it is still not known whether early surgery or active physiological management of the unstable injured spinal cord offers the better chance for recovery. Surgeons who care for patients with traumatic spinal cord injuries in the acute setting should be aware of the arguments on all sides of the debate, a summary of which this annotation presents.

Cite this article: Bone Joint J 2023;105-B(4):347–355.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1104 - 1109
1 Oct 2022
Hansjee S Giebaly DE Shaarani SR Haddad FS

We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation.

Cite this article: Bone Joint J 2022;104-B(10):1104–1109.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 714 - 718
1 Jul 2004
Bickels J Kollender Y Merimsky O Isaakov J Petyan-Brand R Meller I

We report our experience with a new technique for cryosurgical ablation of bone tumours which allows accurate determination of the temperature and freezing time within a cavity of any geometrical shape. Between 1997 and 2000, 58 patients diagnosed with 13 malignant and 45 aggressive benign bone tumours underwent argon-based cryoablation. This technique includes removal of the tumour by curettage and filling the cavity with a gel medium into which metal probes are inserted. Argon gas is delivered through the metal probes and both time and temperature are computer-controlled. After formal reconstruction, all patients were followed for more than two years. None had skin necrosis, infection, neurapraxia or thromboembolic complication. Fractures occurred in two patients (3.4%) and the tumour recurred in two patients (3.4%)


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1047 - 1051
1 Sep 2022
Balato G Dall’Anese R Balboni F Ascione T Pezzati P Bartolini G Quercioli M Baldini A

Aims

The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid.

Methods

Between October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1067 - 1072
1 Sep 2022
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Charalampidis A Nietosvaara Y Helenius I

Aims

The aim of this study was to evaluate whether, after correction of an adolescent idiopathic scoliosis (AIS), leaving out the subfascial drain gives results that are no worse than using a drain in terms of total blood loss, drop in haemoglobin level, and opioid consumption.

Methods

Adolescents (aged between 10 and 21 years) with an idiopathic scoliosis (major curve ≥ 45°) were eligible for inclusion in this randomized controlled noninferiority trial (n = 125). A total of 90 adolescents who had undergone segmental pedicle screw instrumentation were randomized into no-drain or drain groups at the time of wound closure using the sealed envelope technique (1:1). The primary outcome was a drop in the haemoglobin level during first three postoperative days. Secondary outcomes were 48-hour postoperative oxycodone consumption and surgical complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 13 - 15
1 Jan 1991
Toksvig-Larsen S Ryd L Lindstrand A

A saw blade was made from two standard oscillating blades which were fixed to each other with channels between, so that cooling fluid could be directed to the saw teeth. The blade was connected to a standard arthroscopy pump which delivered a flow of 80 ml/min through the blade. The performance of this blade was compared with that of a standard saw blade, cutting ox-bone in the laboratory. Irrigation of the standard saw blade with saline delivered by a syringe only slightly diminished the maximum temperature. Pumped irrigation was more effective but required large volumes of fluid. The heat generated by the internally cooled saw blade was negligible and the temperatures achieved (19 degrees C to 34 degrees C) fell well below the critical level for bone death (44 degrees C to 47 degrees C)


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1556 - 1561
1 Nov 2011
Singhal R Perry DC Khan FN Cohen D Stevenson HL James LA Sampath JS Bruce CE

Clinical prediction algorithms are used to differentiate transient synovitis from septic arthritis. These algorithms typically include the erythrocyte sedimentation rate (ESR), although in clinical practice measurement of the C-reactive protein (CRP) has largely replaced the ESR. We evaluated the use of CRP in a predictive algorithm. The records of 311 children with an effusion of the hip, which was confirmed on ultrasound, were reviewed (mean age 5.3 years (0.2 to 15.1)). Of these, 269 resolved without intervention and without long-term sequelae and were considered to have had transient synovitis. The remaining 42 underwent arthrotomy because of suspicion of septic arthritis. Infection was confirmed in 29 (18 had micro-organisms isolated and 11 had a high synovial fluid white cell count). In the remaining 13 no evidence of infection was found and they were also considered to have had transient synovitis. In total 29 hips were categorised as septic arthritis and 282 as transient synovitis. The temperature, weight-bearing status, peripheral white blood cell count and CRP was reviewed in each patient. A CRP > 20 mg/l was the strongest independent risk factor for septic arthritis (odds ratio 81.9, p < 0.001). A multivariable prediction model revealed that only two determinants (weight-bearing status and CRP > 20 mg/l) were independent in differentiating septic arthritis from transient synovitis. Individuals with neither predictor had a < 1% probability of septic arthritis, but those with both had a 74% probability of septic arthritis. A two-variable algorithm can therefore quantify the risk of septic arthritis, and is an excellent negative predictor.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 42 - 44
1 Jan 1986
Devereaux M Parr G Lachmann S Thomas D Hazleman B

Pain in front of the knee is common in athletes and is often called patellofemoral arthralgia, but it is difficult to prove that the pain arises in that joint. Thermograms of 30 athletes clinically considered to have patellofemoral arthralgia were compared with those of a similar number of unaffected athletes matched for age and sex. A comparison was also made with thermograms of two older groups of 30 patients with knee involvement from either rheumatoid arthritis or osteoarthritis. Twenty-eight of the athletes with patellofemoral arthralgia had a diagnostic pattern on thermography. The anterior knee view showed a rise in temperature on the medial side of the patella and the medialis knee view showed that this temperature rise radiated from the patellar insertion of the vastus medialis into the muscle itself. The possible aetiological role of quadriceps muscle imbalance in athletes with patellofemoral arthralgia is discussed in relation to these findings


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 647 - 656
1 Jun 2022
Knudsen MB Thillemann JK Jørgensen PB Jakobsen SS Daugaard H Søballe K Stilling M

Aims

BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems.

Methods

A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 141 - 144
1 Jan 2015
Hughes AW Clark D Carlino W Gosling O Spencer RF

Reported rates of dislocation in hip hemiarthroplasty (HA) for the treatment of intra-capsular fractures of the hip, range between 1% and 10%. HA is frequently performed through a direct lateral surgical approach. The aim of this study is to determine the contribution of the anterior capsule to the stability of a cemented HA through a direct lateral approach. . A total of five whole-body cadavers were thawed at room temperature, providing ten hip joints for investigation. A Thompson HA was cemented in place via a direct lateral approach. The cadavers were then positioned supine, both knee joints were disarticulated and a digital torque wrench was attached to the femur using a circular frame with three half pins. The wrench applied an external rotation force with the hip in extension to allow the hip to dislocate anteriorly. Each hip was dislocated twice; once with a capsular repair and once without repairing the capsule. Stratified sampling ensured the order in which this was performed was alternated for the paired hips on each cadaver. . Comparing peak torque force in hips with the capsule repaired and peak torque force in hips without repair of the capsule, revealed a significant difference between the ‘capsule repaired’ (mean 22.96 Nm, standard deviation (. sd. ) 4.61) and the ‘capsule not repaired’ group (mean 5.6 Nm, . sd. 2.81) (p < 0.001). Capsular repair may help reduce the risk of hip dislocation following HA. Cite this article: Bone Joint J 2015;97-B:141–4


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1791 - 1801
1 Dec 2021
Bhalekar RM Nargol ME Shyam N Nargol AVF Wells SR Collier R Pabbruwe M Joyce TJ Langton DJ

Aims

The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs).

Methods

At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 495 - 503
1 Apr 2022
Wong LPK Cheung PWH Cheung JPY

Aims

The aim of this study was to assess the ability of morphological spinal parameters to predict the outcome of bracing in patients with adolescent idiopathic scoliosis (AIS) and to establish a novel supine correction index (SCI) for guiding bracing treatment.

Methods

Patients with AIS to be treated by bracing were prospectively recruited between December 2016 and 2018, and were followed until brace removal. In all, 207 patients with a mean age at recruitment of 12.8 years (SD 1.2) were enrolled. Cobb angles, supine flexibility, and the rate of in-brace correction were measured and used to predict curve progression at the end of follow-up. The SCI was defined as the ratio between correction rate and flexibility. Receiver operating characteristic (ROC) curve analysis was carried out to assess the optimal thresholds for flexibility, correction rate, and SCI in predicting a higher risk of progression, defined by a change in Cobb angle of ≥ 5° or the need for surgery.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 103 - 111
1 Jan 2022
Li J Hu Z Qian Z Tang Z Qiu Y Zhu Z Liu Z

Aims

The outcome following the development of neurological complications after corrective surgery for scoliosis varies from full recovery to a permanent deficit. This study aimed to assess the prognosis and recovery of major neurological deficits in these patients, and to determine the risk factors for non-recovery, at a minimum follow-up of two years.

Methods

A major neurological deficit was identified in 65 of 8,870 patients who underwent corrective surgery for scoliosis, including eight with complete paraplegia and 57 with incomplete paraplegia. There were 23 male and 42 female patients. Their mean age was 25.0 years (SD 16.3). The aetiology of the scoliosis was idiopathic (n = 6), congenital (n = 23), neuromuscular (n = 11), neurofibromatosis type 1 (n = 6), and others (n = 19). Neurological function was determined by the American Spinal Injury Association (ASIA) impairment scale at a mean follow-up of 45.4 months (SD 17.2). the patients were divided into those with recovery and those with no recovery according to the ASIA scale during follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 218 - 225
1 Feb 2005
Tsuchiya H Wan SL Sakayama K Yamamoto N Nishida H Tomita K

We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of en bloc excision of the tumour, removal of soft tissue, curettage of the tumour, drilling and preparation for internal fixation or prosthetic replacement before incubation for 20 minutes in liquid nitrogen, thawing at room temperature for 15 minutes, thawing in distilled water for ten minutes, and internal fixation with an intramedullary nail, plate or composite use of prosthetic replacement. Bone graft or cement was used to augment bone strength when necessary. The limb function was rated as excellent in 20 patients (71.4%), good in three (10.7%), fair in three (10.7%), and poor in two (7.1%). At the final follow-up six patients had died at a mean of 19.8 months after the operation, while 21 remained free from disease with a mean follow-up of 28.1 months (10 to 54). One patient is alive with disease. Bony union was seen at a mean of 6.7 months after the operation in 26 patients. Complications were encountered in seven patients, including three deep infections, two fractures, and two local recurrences. All were managed successfully. Our results suggest that this is a simple and effective method of biological reconstruction


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 578 - 583
1 Mar 2021
Coulin B Demarco G Spyropoulou V Juchler C Vendeuvre T Habre C Tabard-Fougère A Dayer R Steiger C Ceroni D

Aims

We aimed to describe the epidemiological, biological, and bacteriological characteristics of osteoarticular infections (OAIs) caused by Kingella kingae.

Methods

The medical charts of all children presenting with OAIs to our institution over a 13-year period (January 2007 to December 2019) were reviewed. Among these patients, we extracted those which presented an OAI caused by K. kingae and their epidemiological data, biological results, and bacteriological aetiologies were assessed.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims

The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty.

Methods

Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output.