Advertisement for orthosearch.org.uk
Results 1 - 100 of 694
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score. Results. At final follow-up, the knee was unstable in 9/18 patients (50%) in the osteoarticular allograft group and 2/15 patients (13%) in the rAPC group (p = 0.026). The median range of motion (ROM) of the knee was 117° (IQR 115° to 120°) in the osteoarticular allograft group and 100° (IQR 95° to 105°) in the rAPC group (p < 0.001). The median MSTS score was 25 (IQR 23 to 26) in the osteoarticular allograft group and 28 (IQR 26 to 29) in the rAPC group (p = 0.007). Osteoarthritic change was detected in 11/18 patients (61%) in the osteoarticular allograft group and in 4/15 (26%) patients in the rAPC group (p = 0.048). Conclusion. In our series, a resurfaced allograft-prosthesis composite provided better knee stability and function, with a lower rate of osteoarthritis; an osteoarticular allograft was associated with better knee ROM. Cite this article: Bone Joint J 2022;104-B(10):1174–1179


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided. Methods. This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively. Results. There was significant improvement in the mean OSS from 24.7 (SD 5.4) preoperatively to 42.0 (SD 6.3) at one year, and this improvement was maintained at 9.1 years (p < 0.001), with a score of 42.8 (SD 6.8). Similar significant improvements in the pain score were seen and maintained at the final follow-up from 6.1 (SD 1.6) to 2.1 (SD 2.3) (p < 0.001). There were also significant improvements in the ROM of the shoulder, and patient satisfaction was high. Conclusion. The use of an interposition human dermal allograft in patients with an irreparable rotator cuff tear leads to good outcomes that are maintained at a mean of nine years postoperatively. Cite this article: Bone Joint J 2022;104-B(1):91–96


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 297 - 301
1 Feb 2022
Jamshidi K Bagherifard A Mohaghegh MR Mirzaei A

Aims. Giant cell tumours (GCTs) of the proximal femur are rare, and there is no consensus about the best method of filling the defect left by curettage. In this study, we compared the outcome of using a fibular strut allograft and bone cement to reconstruct the bone defect after extended curettage of a GCT of the proximal femur. Methods. In a retrospective study, we reviewed 26 patients with a GCT of the proximal femur in whom the bone defect had been filled with either a fibular strut allograft (n = 12) or bone cement (n = 14). Their demographic details and oncological and nononcological complications were retrieved from their medical records. Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. Mean follow-up was 116 months (SD 59.2; 48 to 240) for the fibular strut allograft group and 113 months (SD 43.7; 60 to 192) for the bone cement group (p = 0.391). The rate of recurrence was not significantly different between the two groups (25% vs 21.4%). The rate of nononcological complications was 16.7% in the strut allograft group and 42.8% in the bone cement group. Degenerative joint disease was the most frequent nononcological complication in the cement group. The mean MSTS score of the patients was 92.4% (SD 11.5%; 73.3% to 100.0%) in the fibular strut allograft group and 74.2% (SD 10.5%; 66.7% to 96.7%) in the bone cement group (p < 0.001). Conclusion. Given the similar rate of recurrence and a lower rate of nononcological complications, fibular strut grafting could be recommended as a method of reconstructing the bone defect left by curettage of a GCT of the proximal femur. Cite this article: Bone Joint J 2022;104-B(2):297–301


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims. The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients. Patients and Methods. We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH). Results. The mean forward elevation in the LP and FA groups was 125.3° (. sd. 21.4) and 148.9° (. sd. 19.8), respectively (p = 0.042), while other clinical factors showed no statistically significant differences between the groups. The changes in NSA and HHH immediately after the operation and at final follow-up were significantly better in the FA group than in the LP group (p = 0.015 and p = 0.021, respectively). Conclusion. For comminuted proximal humeral fractures in osteoporotic patients, locking plate fixation with a fibular strut allograft shows satisfactory short-term results with respect to humeral head support and maintenance of reduction, and may reduce the incidence of complications associated with fixation using a locking plate alone. Cite this article: Bone Joint J 2019;101-B:260–265


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 11 - 16
1 Nov 2014
Khanna V Tushinski DM Drexler M Backstein DB Gross AE Safir OA Kuzyk PR

Cartilage defects of the hip cause significant pain and may lead to arthritic changes that necessitate hip replacement. We propose the use of fresh osteochondral allografts as an option for the treatment of such defects in young patients. Here we present the results of fresh osteochondral allografts for cartilage defects in 17 patients in a prospective study. The underlying diagnoses for the cartilage defects were osteochondritis dissecans in eight and avascular necrosis in six. Two had Legg-Calve-Perthes and one a femoral head fracture. Pre-operatively, an MRI was used to determine the size of the cartilage defect and the femoral head diameter. All patients underwent surgical hip dislocation with a trochanteric slide osteotomy for placement of the allograft. The mean age at surgery was 25.9 years (17 to 44) and mean follow-up was 41.6 months (3 to 74). The mean Harris hip score was significantly better after surgery (p < 0.01) and 13 patients had fair to good outcomes. One patient required a repeat allograft, one patient underwent hip replacement and two patients are awaiting hip replacement. Fresh osteochondral allograft is a reasonable treatment option for hip cartilage defects in young patients. Cite this article: Bone Joint J 2014;96-B(11 Supple A):11–16


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 574 - 580
1 May 2007
Delloye C Cornu O Druez V Barbier O

Bone allografts can be used in any kind of surgery involving bone from minor defects to major bone loss after tumour resection. This review describes the various types of bone grafts and the current knowledge on bone allografts, from procurement and preparation to implantation. The surgical conditions for optimising the incorporation of bone are outlined, and surgeon expectations from a bone allograft discussed


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1454
1 Nov 2018
Green CM Buckley SC Hamer AJ Kerry RM Harrison TP

Aims. The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction. Patients and Methods. Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study. Results. At a mean follow-up of 16.9 years, there had been 23 revisions (18.7%), including ten for infection, eight for aseptic loosening, and three for dislocation. Of the 66 surviving hips (58 patients) that could be reassessed, 50 hips (42 patients; 75.6%) were still functioning satisfactorily. Union of the graft had occurred in all hips with a surviving implant. Survival analysis for all indications was 80.6% at 15 years (55 patients at risk, 95% confidence interval (CI) 71.1 to 87.2) and 73.7% at 20 years (eight patients at risk, 95% CI 61.6 to 82.5). Conclusion. Acetabular reconstruction using frozen, irradiated, and morsellized allograft bone and a cemented acetabular component is an effective method of treatment. It gives satisfactory long-term results and is comparable to other types of reconstruction. Cite this article: Bone Joint J 2018;100-B:1449–54


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1155 - 1159
1 Jun 2021
Jamshidi K Zandrahimi F Bagherifard A Mohammadi F Mirzaei A

Aim. There is insufficient evidence to support bony reconstruction of the pubis after a type III internal hemipelvectomy (resection of all or part of the pubis). In this study, we compared surgical complications, postoperative pain, and functional outcome in a series of patients who had undergone a type III internal hemipelvectomy with or without bony reconstruction. Methods. In a retrospective cohort study, 32 patients who had undergone a type III hemipelvectomy with or without allograft reconstruction (n = 15 and n = 17, respectively) were reviewed. The mean follow-up was 6.7 years (SD 3.8) for patients in the reconstruction group and 6.1 years (SD 4.0) for patients in the non-reconstruction group. Functional outcome was evaluated using the Musculoskeletal Tumor Society (MSTS) scoring system and the level of postoperative pain with a visual analogue scale (VAS). Results. The mean MSTS score of the patients was significantly better in patients after reconstruction (26 (SD 1.7) vs 22.7 (SD 2.0); p < 0.001). The mean visual analogue scale score for pain was significantly less in the reconstruction group (2.1 (SD 2) vs 4.2 (SD 2.2); p = 0.016). One infection occurred in each group. Bladder herniation occurred in three patients (17.6%) in the non-reconstruction group but none in the reconstruction group. Five patients (29.4%) in the non-reconstruction group and one (7%) in the reconstruction group had a limp. Graft displacement occurred in two patients in the reconstruction group. Conclusion. We recommend reconstruction of the bony defect after a type III hemipelvectomy: it gives a better functional result, less postoperative pain, and fewer late surgical complications. Cite this article: Bone Joint J 2021;103-B(6):1155–1159


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1568 - 1574
1 Nov 2005
Day RE Megson S Wood D

Allograft bone is widely used in orthopaedic surgery, but peri-operative infection of the graft remains a common and disastrous complication. The efficacy of systemic prophylactic antibiotics is unproven, and since the graft is avascular it is likely that levels of antibiotic in the graft are low. Using an electrical potential to accelerate diffusion of antibiotics into allograft bone, high levels were achieved in specimens of both sheep and human allograft. In human bone these ranged from 187.1 mg/kg in endosteal (. sd. 15.7) to 124.6 (. sd. 46.2) in periosteal bone for gentamicin and 31.9 (. sd. 8.9) in endosteal and 2.9 (. sd. 1.1) in periosteal bone for flucloxacillin. The antibiotics remained active against bacteria in vitro after iontophoresis and continued to elute from the allograft for up to two weeks. Structural allograft can be supplemented directly with antibiotics using iontophoresis. The technique is simple and inexpensive and offers a potential means of reducing the rate of peri-operative infection in allograft surgery. Iontophoresis into allograft bone may also be applicable to other therapeutic compounds


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 973 - 978
1 Jul 2017
Gupta S Kafchinski LA Gundle KR Saidi K Griffin AM Wunder JS Ferguson PC

Aims. Intercalary allografts following resection of a primary diaphyseal tumour have high rates of complications and failures. At our institution intercalary allografts are augmented with intramedullary cement and fixed using compression plating. Our aim was to evaluate their long-term outcomes. Patients and Methods. A total of 46 patients underwent reconstruction with an intercalary allograft between 1989 and 2014. The patients had a mean age of 32.8 years (14 to 77). The most common diagnoses were osteosarcoma (n = 16) and chondrosarcoma (n = 9). The location of the tumours was in the femur in 21, the tibia in 16 and the humerus in nine. Function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The survival of the graft and the overall survival were assessed using the Kaplan-Meier method. Results. The median follow-up was 92 months (4 to 288). The mean MSTS 87 score was 29.1 (19 to 35), the mean MSTS 93 score was 82.2 (50 to 100) and the mean TESS score was 81.2 (43 to 100). Overall survival of the allograft was 84.8%. A total of 15 patients (33%) had a complication. Five allografts were revised for complications and one for local recurrence. Conclusion. Intercalary allografts augmented with intramedullary cement and compression plate fixation provide a reliable and durable method of reconstruction after the excision of a primary diaphyseal bone tumour, with high levels of function and satisfaction. . Cite this article: Bone Joint J 2017;99-B:973–8


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 643 - 648
1 May 2013
Wang J Hsu C Huang C Lin P Chen W

Structural allografts may be used to manage uncontained bone defects in revision total knee replacement (TKR). However, the availability of cadaver grafts is limited in some areas of Asia. The aim of this study was to evaluate the mid-term outcome of the use of femoral head allografts for the reconstruction of uncontained defects in revision TKR, focusing on complications related to the graft. We retrospectively reviewed 28 patients (30 TKRs) with Anderson Orthopaedic Research Institute (AORI) type 3 bone defects, who underwent revision using femoral head allografts and stemmed components. The mean number of femoral heads used was 1.7 (1 to 3). The allograft–host junctions were packed with cancellous autograft. At a mean follow-up of 76 months (38 to 136) the mean American Knee Society knee score improved from 37.2 (17 to 60) pre-operatively to 90 (83 to 100) (p < 0.001). The mean function score improved from 26.5 (0 to 50) pre-operatively to 81 (60 to 100) (p < 0.001). All the grafts healed to the host bone. The mean time to healing of the graft was 6.6 months (4 to 16). There have been no complications of collapse of the graft, nonunion, infection or implant loosening. No revision surgery was required. The use of femoral head allografts in conjunction with a stemmed component and autogenous bone graft in revision TKR in patients with uncontained bone defects resulted in a high rate of healing of the graft with minimal complications and a satisfactory outcome. Longer follow-up is needed to observe the evolution of the graft. Cite this article: Bone Joint J 2013;95-B:643–8


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 92 - 94
1 Nov 2013
Gehrke T Gebauer M Kendoff D

Femoral revision after cemented total hip replacement (THR) might include technical difficulties, following essential cement removal, which might lead to further loss of bone and consequently inadequate fixation of the subsequent revision stem. . Femoral impaction allografting has been widely used in revision surgery for the acetabulum, and subsequently for the femur. In combination with a primary cemented stem, impaction grafting allows for femoral bone restoration through incorporation and remodelling of the impacted morsellized bone graft by the host skeleton. Cavitary bone defects affecting meta-physis and diaphysis leading to a wide femoral shaft, are ideal indications for this technique. Cancellous allograft bone chips of 1 mm to 2 mm size are used, and tapered into the canal with rods of increasing diameters. To impact the bone chips into the femoral canal a prosthesis dummy of the same dimensions of the definitive cemented stem is driven into the femur to ensure that the chips are very firmly impacted. Finally, a standard stem is cemented into the neo-medullary canal using bone cement. . To date several studies have shown favourable results with this technique, with some excellent long-term results reported in independent clinical centres worldwide. Cite this article: Bone Joint J 2013;95-B, Supple A:92–4


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 95 - 99
1 Jan 2006
Ramseier LE Malinin TI Temple HT Mnaymneh WA Exner GU

The outcome of tibial allograft reconstruction after resection of a tumour is inconsistent and has a high rate of failure. There are few reports on the use of tibial allografts in children with open growth plates. We performed 21 allograft reconstructions (16 osteoarticular, five intercalary) in 19 consecutive patients between seven and 17 years of age. Two had Ewing’s sarcoma, one an adamantinoma and 16 osteosarcoma, one with multifocal disease. Five patients have died; the other 14 were free from disease at the time of follow-up. Six surviving patients (eight allograft reconstructions) continue to have good or excellent function at a mean of 59 months (14 to 132). One patient has poor function at 31 months. The other seven patients have a good or excellent function after additional procedures including exchange of the allograft and resurfacing or revision to an endoprosthesis at a mean of 101 months (43 to 198). The additional operations were performed at a mean of 47 months (20 to 84) after the first reconstruction. With the use of allograft reconstruction in growing children, joints and growth plates may be preserved, at least partially. Although our results remain inconsistent, tibial allograft reconstruction in selected patients may restore complete and durable function of the limb


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1430 - 1437
1 Nov 2006
Michalak KA Khoo PPC Yates PJ Day RE Wood DJ

Revision arthroplasty after infection can often be complicated by both extensive bone loss and a relatively high rate of re-infection. Using allograft to address the bone loss in such patients is controversial because of the perceived risk of bacterial infection from the use of avascular graft material. We describe 12 two-stage revisions for infection in which segmental allografts were loaded with antibiotics using iontophoresis, a technique using an electrical potential to drive ionised antibiotics into cortical bone. Iontophoresis produced high levels of antibiotic in the allograft, which eluted into the surrounding tissues. We postulate that this offers protection from infection in the high-risk peri-operative period. None of the 12 patients who had two-stage revision with iontophoresed allografts had further infection after a mean period of 47 months (14 to 78)


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 537 - 541
1 Apr 2011
Song WS Kong C Jeon D Cho WH Kim JR Lee S

The use of allografts for the treatment of bone tumours in children is limited by nonunion and the difficulty of finding a suitable graft. Furthermore, appositional growth can’t be expected of an allograft. We used an overlapping allograft in 11 children, with a mean age of ten years (4 to 15), with a mean follow-up of 24.1 months (20 to 33). There were five intercalary and six intra-articular resections, and the tumours were in the femur in six cases and the humerus in five. Rates of union, times to union, remodelling patterns and allograft-associated complications were evaluated. No allograft was removed due to a complication. Of the 16 junctional sites, 15 (94%) showed union at a mean of 3.1 months (2 to 5). Remodelling between host and allograft was seen at 14 junctions at a mean of five months (4 to 7). The mean Musculoskeletal Tumor Society score was 26.5 of 30 (88.3%). One case of nonunion and another with screw protrusion required re-operation. Overlapping allografts have the potential to shorten time to union, decrease rates of nonunion and have positive appositional growth effect


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1194 - 1200
1 Sep 2011
Akiyama H Yamamoto K Tsukanaka M Kawanabe K Otsuka H So K Goto K Nakamura T

We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts were used for the management of Type III defects in 23 hips. A total of five hips showed radiological failure at a mean follow-up of 6.7 years (4.5 to 9.3), two of which were infected. The mean pre-operative Merle d’Aubigné score was 10 (5 to 15) vs 13.6 (9 to 18) at the latest follow-up. The Kaplan-Meier survival rate at ten years, calculated using radiological failure or revision of the acetabular component for any reason as the endpoint, was 87% (95% confidence interval 76.3 to 97.7). A separate experimental analysis of the mechanical properties of the device and the load-displacement properties of bone grafts showed that a structurally hard allograft resected from femoral heads of patients with osteoarthritis should be preferentially used in any type of defect. If impacted bone allografts were used, a bone graft thickness of < 25 mm was acceptable in Type II defects. This clinical study indicates that revision total hip replacement using the Kerboull-type acetabular reinforcement device with bone allografts yielded satisfactory mid-term results


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 46 - 52
1 Jan 2019
León SA Mei XY Safir OA Gross AE Kuzyk PR

Aims. The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function. Patients and Methods. We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score. Results. A total of 14 grafts (23.3%) failed at a mean of 8.6 years (1.4 to 20.1). Graft survivorship was 87.3% (95% confidence interval (CI) 79.0 to 96.6), 85.0% (95% CI 75.8 to 95.3), 74.8% (95% CI 62.2 to 90.0), 65.2% (95% CI 49.9 to 85.2), and 59.8% (95% CI 43.5 to 82.1) at five, ten, 15, 20, and 25 years, respectively. A total of 23 patients (38.3%) developed complications, and 26 (43.3%) had a further operation. Persistent postoperative malalignment occurred more frequently in failed grafts (28.6% vs 4.3%; p = 0.023), and was a risk factor for graft failure (hazard ratio 6.55; 95% CI 1.61 27.71; p = 0.009). The mean mHSS score improved from 74.1 (40 to 91) preoperatively to 89.0 (66 to 100) at final follow-up (p < 0.001). Conclusion. Femoral condylar FOCA with concomitant realignment osteotomy provides excellent long-term graft survival and reliable functional improvement. Persistent malalignment may increase the risk for graft failure


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 838 - 844
1 Jul 2020
Chen L Hong G Hong Z Lin T Chen Z Zhang Q He W

Aims. The aim of this study was to report the medium-term outcomes of impaction bone allograft and fibular grafting for osteonecrosis of the femoral head (ONFH) and to define the optimal indications. Methods. A total of 67 patients (77 hips) with ONFH were enrolled in a single centre retrospective review. Success of the procedure was assessed using the Harris Hip Score (HHS) and rate of revision to total hip arthroplasty (THA). Risk factors were studied, including age, aetiology, duration of hip pain, as well as two classification systems (Association Research Circulation Osseous (ARCO) and Japanese Investigation Committee (JIC) systems). Results. After a mean follow-up period of 8.61 years (SD 1.45), 81.3% (52/64) of enrolled cases had a good or excellent HHS at latest follow-up (declining to 76.0% (38/50) for those with more than eight years of follow-up). Overall survival was 92.1% at eight years’ follow-up (95% CI 83.2% to 96.4%). A total of 12 hips (19.0%) failed (reoperation or HHS < 70 points) at final follow-up. Rate of success was adversely affected by increasing age, duration of pain, and more severe disease as measured using the ARCO and JIC classifications, but not by aetiology of the ONFH. Conclusion. We report favourable medium-term results of this procedure. Best outcomes can be expected in patients matching the following indications: younger than 40 years; less 12-month hip pain before surgery; femoral head collapse being less than 2 mm; and integrated lateral wall of femoral head. Cite this article: Bone Joint J 2020;102-B(7):838–844


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1149 - 1157
1 Sep 2006
Khoo PPC Michalak KA Yates PJ Megson SM Day RE Wood DJ

Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82)


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1225 - 1228
1 Sep 2007
van de Pol GJ Sturm PDJ van Loon CJ Verhagen C Schreurs BW

Allografts of bone from the femoral head are often used in orthopaedic procedures. Although the donated heads are thoroughly tested microscopically before release by the bone bank, some surgeons take additional cultures in the operating theatre before implantation. There is no consensus about the need to take these cultures. We retrospectively assessed the clinical significance of the implantation of positive-cultured bone allografts. The contamination rate at retrieval of the allografts was 6.4% in our bone bank. Intra-operative cultures were taken from 426 femoral head allografts before implantation; 48 (11.3%) had a positive culture. The most frequently encountered micro-organism was coagulase-negative staphylococcus. Deep infection occurred in two of the 48 patients (4.2%). In only one was it likely that the same micro-organism caused the contamination and the subsequent infection. In our study, the rate of infection in patients receiving positive-cultured allografts at implantation was not higher than the overall rate of infection in allograft surgery suggesting that the positive cultures at implantation probably represent contamination and that the taking of additional cultures is not useful


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1684 - 1687
1 Dec 2005
Buttaro MA Morandi A Rivello HG Piccaluga F

Vancomycin-supplemented allografts provide biological restoration of bone stock and sound fixation with a low incidence of re-infection. Experimental incorporation of these grafts is similar to allografts without vancomycin. However, the underlying biology remains unknown. We report the first histological observations of vancomycin-supplemented impacted bone allografts in two reconstructions performed 14 and 20 months after revision surgery because of a periprosthetic fracture. Areas of active bone remodelling (creeping substitution), as well as calcified bone trabeculae and graft particles embedded in dense fibrous tissue, were observed with osteoid and fibroconnective tissue surrounding polymethylmethacrylate particles. These pathological findings are similar to those reported in allografts without vancomycin and support the hypothesis that high levels of vancomycin do not affect the incorporation of bone graft


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 342 - 345
1 Mar 2007
Vaidya R Weir R Sethi A Meisterling S Hakeos W Wybo CD

We carried out a prospective study to determine whether the addition of a recombinant human bone morphogenetic protein (rhBMP-2) to a machined allograft spacer would improve the rate of intervertebral body fusion in the spine. We studied 77 patients who were to undergo an interbody fusion with allograft and instrumentation. The first 36 patients received allograft with adjuvant rhBMP-2 (allograft/rhBMP-2 group), and the next 41, allograft and demineralised bone matrix (allograft/demineralised bone matrix group). Each patient was assessed clinically and radiologically both pre-operatively and at each follow-up visit using standard methods. Follow-up continued for two years. Every patient in the allograft/rhBMP-2 group had fused by six months. However, early graft lucency and significant (> 10%) subsidence were seen radiologically in 27 of 55 levels in this group. The mean graft height subsidence was 27% (13% to 42%) for anterior lumbar interbody fusion, 24% (13% to 40%) for transforaminal lumbar interbody fusion, and 53% (40% to 58%) for anterior cervical discectomy and fusion. Those who had undergone fusion using allograft and demineralised bone matrix lost only a mean of 4.6% (0% to 15%) of their graft height. Although a high rate of fusion (100%) was achieved with rhBMP-2, significant subsidence occurred in more than half of the levels (23 of 37) in the lumbar spine and 33% (6 of 18) in the cervical spine. A 98% fusion rate (62 of 63 levels) was achieved without rhBMP-2 and without the associated graft subsidence. Consequently, we no longer use rhBMP-2 with allograft in our practice if the allograft has to provide significant structural support


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 314 - 319
1 Mar 2005
Buttaro MA Pusso R Piccaluga F

Bone allografts can store and release high levels of vancomycin. We present our results of a two-stage treatment for infected hip arthroplasty with acetabular and femoral impaction grafting using vancomycin-loaded allografts. We treated 29 patients (30 hips) by removal of the implants, meticulous debridement, parenteral antibiotic therapy and second-stage reconstruction using vancomycin-supplemented impacted bone allografts and a standard cemented Charnley femoral component. The mean follow-up was 32.4 months (24 to 60). Infection control was obtained in 29 cases (re-infection rate of 3.3%; 95% confidence interval 0.08 to 17) without evidence of progressive radiolucent lines, demarcation or graft resorption. One patient had a further infection ten months after revision caused by a different pathogen. Associated post-operative complications were one traumatic periprosthetic fracture at 14 months, a single dislocation in two hips and four displacements of the greater trochanter. Vancomycin-supplemented allografts restored bone stock and provided sound fixation with a low incidence of further infection


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 378 - 386
1 Mar 2018
Campanacci DA Totti F Puccini S Beltrami G Scoccianti G Delcroix L Innocenti M Capanna R

Aims. After intercalary resection of a bone tumour from the femur, reconstruction with a vascularized fibular graft (VFG) and massive allograft is considered a reliable method of treatment. However, little is known about the long-term outcome of this procedure. The aims of this study were to determine whether the morbidity of this procedure was comparable to that of other reconstructive techniques, if it was possible to achieve a satisfactory functional result, and whether biological reconstruction with a VFG and massive allograft could achieve a durable, long-lasting reconstruction. Patients and Methods. A total of 23 patients with a mean age of 16 years (five to 40) who had undergone resection of an intercalary bone tumour of the femur and reconstruction with a VFG and allograft were reviewed clinically and radiologically. The mean follow-up was 141 months (24 to 313). The mean length of the fibular graft was 18 cm (12 to 29). Full weight-bearing without a brace was allowed after a mean of 13 months (seven to 26). Results. At final follow-up, the mean Musculoskeletal Tumor Society Score of 22 evaluable patients was 94% (73 to 100). Eight major complications, five fractures (21.7%), and three nonunions (13%) were seen in seven patients (30.4%). Revision-free survival was 72.3% at five, ten, and 15 years, with fracture and nonunion needing surgery as failure endpoints. Overall survival, with removal of allograft or amputation as failure endpoints, was 94.4% at five, ten, and 15 years. Discussion. There were no complications needing surgical revision after five years had elapsed from surgery, suggesting that the mechanical strength of the implant improves with time, thereby decreasing the risk of complications. In young patients with an intercalary bone tumour of the femur, combining a VFG and massive allograft may result in a reconstruction that lasts a lifetime. Cite this article: Bone Joint J 2018;100-B:378–86


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 121 - 128
1 Jan 2015
Kang S Han I Hong SH Cho HS Kim W Kim H

Cancellous allograft bone chips are commonly used in the reconstruction of defects in bone after removal of benign tumours. We investigated the MRI features of grafted bone chips and their change over time, and compared them with those with recurrent tumour. We retrospectively reviewed 66 post-operative MRIs from 34 patients who had undergone curettage and grafting with cancellous bone chips to fill the defect after excision of a tumour. All grafts showed consistent features at least six months after grafting: homogeneous intermediate or low signal intensities with or without scattered hyperintense foci (speckled hyperintensities) on T1 images; high signal intensities with scattered hypointense foci (speckled hypointensities) on T2 images, and peripheral rim enhancement with or without central heterogeneous enhancements on enhanced images. Incorporation of the graft occurred from the periphery to the centre, and was completed within three years. Recurrent lesions consistently showed the same signal intensities as those of pre-operative MRIs of the primary lesions. There were four misdiagnoses, three of which were chondroid tumours. We identified typical MRI features and clarified the incorporation process of grafted cancellous allograft bone chips. The most important characteristics of recurrent tumours were that they showed the same signal intensities as the primary tumours. It might sometimes be difficult to differentiate grafted cancellous allograft bone chips from a recurrent chondroid tumour. Cite this article: Bone Joint J 2015;97-B:121–8


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 121 - 126
1 Jan 2007
Jensen TB Overgaard S Lind M Rahbek O Bünger C Søballe K

Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1. After three weeks osteogenic protein-1 increased bone formation and the energy absorption of implants grafted with allograft and ProOsteon. A composite of allograft, ProOsteon and osteogenic protein-1 was comparable, but not superior to, allograft used on its own. ProOsteon alone cannot be recommended as a substitute for allograft around non-cemented implants, but should be used to extend the volume of the graft, preferably with the addition of a growth factor


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1414 - 1420
1 Aug 2021
Wellings EP Houdek MT Owen AR Bakri K Yaszemski MJ Sim FH Moran SL Rose PS

Aims. Orthopaedic and reconstructive surgeons are faced with large defects after the resection of malignant tumours of the sacrum. Spinopelvic reconstruction is advocated for resections above the level of the S1 neural foramina or involving the sacroiliac joint. Fixation may be augmented with either free vascularized fibular flaps (FVFs) or allograft fibular struts (AFSs) in a cathedral style. However, there are no studies comparing these reconstructive techniques. Methods. We reviewed 44 patients (23 female, 21 male) with a mean age of 40 years (SD 17), who underwent en bloc sacrectomy for a malignant tumour of the sacrum with a reconstruction using a total (n = 20), subtotal (n = 2), or hemicathedral (n = 25) technique. The reconstructions were supplemented with a FVF in 25 patients (57%) and an AFS in 19 patients (43%). The mean length of the strut graft was 13 cm (SD 4). The mean follow-up was seven years (SD 5). Results. There was no difference in the mean age, sex, length of graft, size of the tumour, or the proportion of patients with a history of treatment with radiotherapy in the two groups. Reconstruction using an AFS was associated with nonunion (odds ratio 7.464 (95% confidence interval (CI) 1.77 to 31.36); p = 0.007) and a significantly longer mean time to union (12 months (SD 3) vs eight (SD 3); p = 0.001) compared with a reconstruction using a FVF. Revision for a pseudoarthrosis was more likely to occur in the AFS group compared with the FVF group (hazard ratio 3.84 (95% CI 0.74 to 19.80); p = 0.109); however, this was not significant. Following the procedure, 32 patients (78%) were mobile with a mean Musculoskeletal Tumor Society Score 93 of 52% (SD 24%). There was a significantly higher mean score in patients reconstructed with a FVF compared with an AFS (62% vs 42%; p = 0.003). Conclusion. Supplementation of spinopelvic reconstruction with a FVF was associated with a shorter time to union and a trend towards a reduced risk of hardware failure secondary to nonunion compared with reconstruction using an AFS. Spinopelvic fixation supplemented with a FVF is our preferred technique for reconstruction following resection of a sacral tumour. Cite this article: Bone Joint J 2021;103-B(8):1414–1420


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 427 - 431
1 Mar 2015
Wu C Hsieh P Fan Jiang J Shih H Chen C Hu C

Fresh-frozen allograft bone is frequently used in orthopaedic surgery. We investigated the incidence of allograft-related infection and analysed the outcomes of recipients of bacterial culture-positive allografts from our single-institute bone bank during bone transplantation. The fresh-frozen allografts were harvested in a strict sterile environment during total joint arthroplasty surgery and immediately stored in a freezer at -78º to -68º C after packing. Between January 2007 and December 2012, 2024 patients received 2083 allografts with a minimum of 12 months of follow-up. The overall allograft-associated infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts taken before implantation revealed 21 (1.0%) positive findings. The 21 recipients were given various antibiotics at the individual orthopaedic surgeon’s discretion. At the latest follow-up, none of these 21 recipients displayed clinical signs of infection following treatment. Based on these findings, we conclude that an incidental positive culture finding for allografts does not correlate with subsequent surgical site infection. Additional prolonged post-operative antibiotic therapy may not be necessary for recipients of fresh-frozen bone allograft with positive culture findings. Cite this article: Bone Joint J 2015;97-B:427–31


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 70 - 72
1 Nov 2014
Callaghan JJ Liu SS Phruetthiphat O

A common situation presenting to the orthopaedic surgeon today is a worn acetabular liner with substantial acetabular and pelvic osteolysis. The surgeon has many options for dealing with osteolytic defects. These include allograft, calcium based substitutes, demineralised bone matrix, or combinations of these options with or without addition of platelet rich plasma. To date there are no clinical studies to determine the efficacy of using bone-stimulating materials in osteolytic defects at the time of revision surgery and there are surprisingly few studies demonstrating the clinical efficacy of these treatment options. Even when radiographs appear to demonstrate incorporation of graft material CT studies have shown that incorporation is incomplete. The surgeon, in choosing a graft material for a surgical procedure must take into account the efficacy, safety, cost and convenience of that material. Cite this article: Bone Joint J 2014;96-B (11 Suppl A):70–2


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1292 - 1297
1 Sep 2005
Lietman SA Inoue N Rafiee B Deitz LW Chao EYS

We used a canine intercalary bone defect model to determine the effects of recombinant human osteogenic protein 1 (rhOP-1) on allograft incorporation. The allograft was treated with an implant made up of rhOP-1 and type I collagen or with type I collagen alone. Radiographic analysis showed an increased volume of periosteal callus in both test groups compared with the control group at weeks 4, 6, 8 and 10. Mechanical testing after 12 weeks revealed increased maximal torque and stiffness in the rhOP-1 treated groups compared with the control group. These results indicate a benefit from the use of an rhOP-1 implant in the healing of bone allografts. The effect was independent of the position of the implant. There may be a beneficial clinical application for this treatment


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 319 - 324
1 Mar 2014
Abolghasemian M Sadeghi Naini M Tangsataporn S Lee P Backstein D Safir O Kuzyk P Gross AE

We retrospectively reviewed 44 consecutive patients (50 hips) who underwent acetabular re-revision after a failed previous revision that had been performed using structural or morcellised allograft bone, with a cage or ring for uncontained defects. Of the 50 previous revisions, 41 cages and nine rings were used with allografts for 14 minor-column and 36 major-column defects. We routinely assessed the size of the acetabular bone defect at the time of revision and re-revision surgery. This allowed us to assess whether host bone stock was restored. We also assessed the outcome of re-revision surgery in these circumstances by means of radiological characteristics, rates of failure and modes of failure. We subsequently investigated the factors that may affect the potential for the restoration of bone stock and the durability of the re-revision reconstruction using multivariate analysis. At the time of re-revision, there were ten host acetabula with no significant defects, 14 with contained defects, nine with minor-column, seven with major-column defects and ten with pelvic discontinuity. When bone defects at re-revision were compared with those at the previous revision, there was restoration of bone stock in 31 hips, deterioration of bone stock in nine and remained unchanged in ten. This was a significant improvement (p <  0.001). Morselised allografting at the index revision was not associated with the restoration of bone stock. . In 17 hips (34%), re-revision was possible using a simple acetabular component without allograft, augments, rings or cages. There were 47 patients with a mean follow-up of 70 months (6 to 146) available for survival analysis. Within this group, the successful cases had a minimum follow-up of two years after re-revision. There were 22 clinical or radiological failures (46.7%), 18 of which were due to aseptic loosening. The five and ten year Kaplan–Meier survival rate was 75% (95% CI, 60 to 86) and 56% (95% CI, 40 to 70) respectively with aseptic loosening as the endpoint. The rate of aseptic loosening was higher for hips with pelvic discontinuity (p = 0.049) and less when the allograft had been in place for longer periods (p = 0.040). . The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent re-revision surgery to a certain extent. Cite this article: Bone Joint J 2014;96-B:319–24


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 836 - 841
1 Jun 2012
Frisoni T Cevolani L Giorgini A Dozza B Donati DM

We retrospectively reviewed 101 consecutive patients with 114 femoral tumours treated by massive bone allograft at our institution between 1986 and 2005. There were 49 females and 52 males with a mean age of 20 years (4 to 74). At a median follow-up of 9.3 years (2 to 19.8), 36 reconstructions (31.5%) had failed. The allograft itself failed in 27 reconstructions (24%). Mechanical complications such as delayed union, fracture and failure of fixation were studied. The most adverse factor on the outcome was the use of intramedullary nails, followed by post-operative chemotherapy, resection length > 17 cm and age > 18 years at the time of intervention. The simultaneous use of a vascularised fibular graft to protect the allograft from mechanical complications improved the outcome, but the use of intramedullary cementing was not as successful. In order to improve the strength of the reconstruction and to advance the biology of host–graft integration, we suggest avoiding the use of intramedullary nails and titanium plates, but instead using stainless steel plates, as these gave better results. The use of a supplementary vascularised fibular graft should be strongly considered in adult patients with resection > 17 cm and in those who require post-operative chemotherapy


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 393 - 397
1 May 1992
Stockley I McAuley J Gross A

We reviewed 32 deep-frozen irradiated allografts used for the reconstruction of bone defects in 20 knees. They were subdivided into bulk grafts, cortical strut grafts, and morsellised bone. The average follow-up was 4.2 years (2 to 7.2). Radiographs showed union of the allograft to the host in all cases. Two allografts later fractured and three knees required further surgery because of infection. The allografts effectively filled large bone defects around the knee, lessening the need for custom-made and constrained prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 228 - 231
1 Feb 2008
Buttaro M Araujo GS Araujo ES Comba F Piccaluga F

Metal meshes are used in revision surgery of the hip to contain impacted bone grafts in cases with cortical or calcar defects in order to provide rotational stability to the stem. However, the viability of bone allografts under these metal meshes has been uncertain. We describe the histological appearances of biopsies obtained from impacted bone allografts to the calcar contained by a metal mesh in two femoral reconstructions which needed further surgery at 24 and 33 months after the revision procedure. A line of osteoid and viable new bone was observed on the surface of necrotic trabeculae. Active bone marrow between these trabeculae showed necrotic areas in some medullary spaces with reparative fibrous tissue and isolated reactive lymphocytes. This is interpreted as reparative changes after revascularisation of the cancellous allografts. These pathological findings are similar to those reported in allografts contained by cortical host bone and support the hypothesis that incorporation of morcellised bone under metal meshes is not affected by these devices


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 421 - 425
1 Mar 2005
Blom AW Cunningham JL Hughes G Lawes TJ Smith N Blunn G Learmonth ID Goodship AE

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens. There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 235 - 240
1 Mar 1991
Allan D Lavoie G McDonald S Oakeshott R Gross A

We followed prospectively 69 patients with 78 proximal femoral allografts performed for revision of total hip arthroplasty for an average of 36 months (range 29 to 68). Large fragment proximal femoral allografts and cortical strut allografts were successful in 85%. Grafts smaller than 3 cm in length (calcar grafts) were clinically successful in 81%, but 50% underwent significant radiographic resorption. We conclude that large proximal femoral allografts and cortical strut allografts provide dependable reconstruction of bone stock deficiencies during revision total hip arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 830 - 836
1 Aug 2000
Haddad FS Garbuz DS Masri BA Duncan CP

There are few medium- and long-term data on the outcome of the use of proximal femoral structural allografts in revision hip arthroplasty. This is a study of a consecutive series of 40 proximal femoral allografts performed for failed total hip replacements using the same technique with a minimum follow-up of five years (mean 8.8 years; range 5 to 11.5 years). In all cases the stem was cemented into both the allograft and the host femur. The proximal femur of the host was resected in 37 cases. There were four early revisions (10%), two for infection, one for nonunion of the allograft-host junction, and one for allograft resorption noted at the time of revision of a failed acetabular reconstruction. Junctional nonunion was seen in three patients (8%), two of whom were managed successfully by bone grafting, and bone grafting and plating respectively. Instability was observed in four (10%). Trochanteric nonunion was seen in 18 patients (46%) and trochanteric escape in ten of these (27%). The mean Harris hip score improved from 39 to 79. Severe resorption involving the full thickness of the allograft was seen in seven patients (17.5%). This progressed rapidly and silently, but has yet to cause failure of any of the reconstructions. Profound resorption of the allograft may be related to a combination of factors, including a slow form of immune rejection, stress shielding and resorption due to mechanical disuse with solid cemented distal fixation, and the absence of any masking or protective effect which may be provided by the retention of the bivalved host bone as a vascularised onlay autograft. Although continued surveillance is warranted, the very good medium-term clinical results justify the continued use of structural allografts for failed total hip replacements with severe loss of proximal femoral bone


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 398 - 399
1 May 1992
Chapman P Villar R

We report the contamination rate in the Cambridge bone bank of 35 consecutive allograft specimens, all harvested in a clean-air environment, using a strict aseptic technique and antibiotic cover. Five of 27 femoral heads taken from living donors and three of eight massive allografts taken from cadavers were found to be contaminated. The contaminated femoral heads were discarded. All massive allografts were rendered sterile by gamma-irradiation. It is important to exclude bacteriological contamination of harvested and banked bone


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 336 - 341
1 Mar 1999
Sugihara S van Ginkel AD Jiya TU van Royen BJ van Diest PJ Wuisman PIJM

From November 1994 to March 1997, we harvested 137 grafts of the femoral head from 125 patients for donation during total hip arthroplasty according to the guidelines of the American Associations of Tissue Banks (AATB) and the European Association of Musculo-Skeletal transplantation (EAMST). In addition to the standards recommended by these authorities, we performed histopathological examination of a core biopsy of the retrieved bone allograft and of the synovium. Of the 137 allografts, 48 (35.0%) fulfilled all criteria and were free for donation; 31 (22.6%) were not regarded as suitable for transplantation because the serological retests at six months were not yet complete and 58 (42.3%) were discarded because of incomplete data. Of those discarded, five showed abnormal histopathological findings; three were highly suspicious of low-grade B-cell lymphoma, one of monoclonal plasmacytosis and the other of non-specific inflammation of bone marrow. However, according to the standards of the AATB or EAMST they all met the criteria and were eligible for transplantation. Our findings indicate that the incidence of abnormal histopathology in these retrieved allografts was 3.6%. Since it is essential to confirm the quality of donor bones in bone banking, we advise that histopathological screening of donor bone should be performed to exclude abnormal allografts


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1228 - 1231
1 Sep 2006
Peidro L Segur JM Poggio D de Retana PF

Glenoid replacement is technically challenging. Removal of a cemented glenoid component often results in a large osseous defect which makes the immediate introduction of a revision prosthesis almost impossible. We describe a two-stage revision procedure using a reversed shoulder prosthesis. Freeze-dried allograft with platelet-derived growth factor was used to fill the glenoid defect. Radiological incorporation of the allograft was seen and its consistency allowed the placement of a screwed glenoid component. There were no signs of new mature bone formation on histological examination. The addition of platelet-derived growth factor to the allograft seems to contribute to an increase in incorporation and hardness, but does not promote the growth of new bone


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1050 - 1055
1 Aug 2015
Drexler M Abolghasemian M Kuzyk PR Dwyer T Kosashvili Y Backstein D Gross AE Safir O

This study reports the clinical outcome of reconstruction of deficient abductor muscles following revision total hip arthroplasty (THA), using a fresh–frozen allograft of the extensor mechanism of the knee. A retrospective analysis was conducted of 11 consecutive patients with a severe limp because of abductor deficiency which was confirmed on MRI scans. The mean age of the patients (three men and eight women) was 66.7 years (52 to 84), with a mean follow-up of 33 months (24 to 41). . Following surgery, two patients had no limp, seven had a mild limp, and two had a persistent severe limp (p = 0.004). The mean power of the abductors improved on the Medical Research Council scale from 2.15 to 3.8 (p < 0.001). Pre-operatively, all patients required a stick or walking frame; post-operatively, four patients were able to walk without an aid. Overall, nine patients had severe or moderate pain pre-operatively; ten patients had no or mild pain post-operatively. . At final review, the Harris hip score was good in five patients, fair in two and poor in four. . We conclude that using an extensor mechanism allograft is relatively effective in the treatment of chronic abductor deficiency of the hip after THA when techniques such as local tissue transfer are not possible. . Longer-term follow-up is necessary before the technique can be broadly applied. Cite this article: Bone Joint J 2015;97-B:1050–5


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 746 - 750
1 Jun 2011
Zampelis V Ornstein E Franzén H Atroshi I

Previously, radiostereometric analysis following hip revision performed using impacted morsellised allograft bone and a cemented Exeter stem has shown continuous subsidence of the stem for up to five years. It is not known whether the subsidence continues thereafter. In our study, 17 of 25 consecutive osteo-arthritic patients with aseptically loose stems who underwent first-time revision using impacted morsellised allograft bone and a cemented Exeter stem were followed by yearly radiostereometric examinations for nine years. The mean subsidence at six weeks was 1.1 mm (0.1 to 2.3), from six weeks to one year 1.3 mm (0 to 2.6), from one to five years 0.7 mm (0 to 2.0), and from five to nine years 0.7 mm (0.1 to 3.1). That from six weeks to nine years was 2.7 mm (0 to 6.4) (95% confidence interval 2.0 to 3.5). The Charnley pain score significantly improved after revision, and was maintained at nine years, but walking ability deteriorated slightly as follow-up extended. Of the eight patients who were not followed for nine years, two had early subsidence exceeding 11 mm. Our findings show that in osteo-arthritic patients who undergo revision for aseptic loosening of the stem using impacted morsellised allograft bone and a cemented Exeter stem, migration of the stem continues over nine years at a slower rate after the first year, but without clinical deterioration or radiological loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1690 - 1694
1 Dec 2010
Scoccianti G Campanacci DA Beltrami G Caldora P Capanna R

Several techniques have been described to reconstruct a mobile wrist joint after resection of the distal radius for tumour. We reviewed our experience of using an osteo-articular allograft to do this in 17 patients with a mean follow-up of 58.9 months (28 to 119). The mean range of movement at the wrist was 56° flexion, 58° extension, 84° supination and 80° pronation. The mean ISOLS-MSTS score was 86% (63% to 97%) and the mean patient-rated wrist evaluation score was 16.5 (3 to 34). There was no local recurrence or distant metastases. The procedure failed in one patient with a fracture of the graft and an arthrodesis was finally required. Union was achieved at the host-graft interface in all except two cases. No patient reported more than modest non-disabling pain and six reported no pain at all. Radiographs showed early degenerative changes at the radiocarpal joint in every patient. A functional pain-free wrist can be restored with an osteo-articular allograft after resection of the distal radius for bone tumour, thereby avoiding the donor site morbidity associated with an autograft. These results may deteriorate with time


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1524 - 1526
1 Nov 2005
Kwong FNK Ibrahim T Power RA

Implantation of allograft bone is an integral part of revision surgery of the hip. One major concern with its use is the risk of transmission of infective agents. There are a number of methods of processing allograft bone in order to reduce this risk. One method requires washing the tissue using pulsed irrigation immediately before implantation. We report the incidence of deep bacterial infection in 138 patients (144 revision hip arthroplasties) who had undergone implantation of allograft bone. The bone used was fresh-frozen, non-irradiated and pulse-washed with normal saline before implantation. The deep infection rate at a minimum follow-up of one year was 0.7%. This method of processing appears to be associated with a very low risk of allograft-related bacterial infection


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 908 - 913
1 Nov 1997
Masterson EL Masri BA Duncan CP Rosenberg A Cabanela M Gross M

An analysis of the cement mantle obtained with the Exeter impaction allografting system at one centre showed that it was either deficient or absent in almost 47% of Gruen zones. We therefore examined the mantle obtained using this system at another hospital and compared the results with those from the CPT and Harris Precoat Systems at other centres. The surgical indications for the procedure and the patient details were broadly similar in all four hospitals. There was some variation in the frequency of use of cortical strut allografts, cerclage wires and wire mesh to supplement the impaction allograft. Analysis of the cement mantles showed that when uncertain Gruen zones were excluded, the incidence of zones with areas of absence or deficiency of the cement was 47% and 50%, respectively, for the two centres using the Exeter system, 21% for the CPT system and 18% for the Harris Precoat system. We measured the difference in size between the proximal allograft impactors and the definitive prosthesis for each system. The Exeter system impactors are shorter than the definitive prosthesis and taper sharply so that the cavity created is inadequate, especially distally. The CPT proximal impactors are considerably longer than the definitive prosthesis and are designed to give a mantle of approximately 2 mm medially and laterally and 1.5 mm anteriorly and posteriorly. The Harris Precoat proximal impactors allow for a mantle with a circumference of 0.75 mm in the smaller sizes and 1 mm in the larger. Many reports link the longevity of a cemented implant to the adequacy of the cement mantle. For this reason, femoral impaction systems require careful design to achieve a cement mantle which is uninterrupted in its length and adequate in its thickness. Our results suggest that some current systems require modification


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1006 - 1010
1 Sep 2000
Rödl RW Ozaki T Hoffmann C Böttner F Lindner N Winkelmann W

We assessed the results of 17 limb-salvage procedures using osteoarticular allografts after wide resection of high-grade malignant bone tumours. All patients received chemotherapy. At the five-year follow-up, three patients had died from metastases. The allografts survived for five years in only seven patients all of whom had good function, ranging from 73% to 90% of normal. The allografts were removed because of fracture in seven patients and infection in one, and in all of these a second limb-salvage procedure was undertaken. With such a low rate of survival of osteoarticular allografts, we believe that their use in the management of high-grade malignant bone tumours should, at best, be considered a temporary solution


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 419 - 422
1 May 1994
Hooten J Engh C Engh C

We investigated the radiographic and clinical course of 31 patients in whom a bulk acetabular allograft had been used during the cementless revision of a total hip replacement. Two patients died and two were lost to follow-up within 24 months, but of the remaining 27 acetabular components, 12 (44%) showed radiographic evidence of instability at a mean of 46 months. Five of these have been revised. In the 12 failures, signs of instability had been noted at an average of 29 months (1 to 60). Failures during the first 24 months were usually due to technical errors, later failures to gradual migration of the cup into the graft. The cups with the greatest amount of their surface supported by grafts were most likely to migrate, but this migration was usually asymptomatic. Screw fixation of the cup, used in 24 cases, appeared to control the mechanism of failure. Femoral head allografts and distal femoral allografts had been used, with failure in 6 of 16, and 6 of 11 respectively; distal femoral allografts were used only for large defects. The insidious course of late cup migration and graft failure necessitates close radiographic follow-up of patients treated with bulk allografts


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 994 - 998
1 Nov 1998
Kumta SM Leung PC Griffith JF Roebuck DJ Chow LTC Li CK

The aim of limb-salvage surgery in malignant bone tumours in children is to restore function and eradicate local disease with as little morbidity as possible. Allografts are associated with a high rate of complications, particularly malunion at the allograft-host junction. We describe a simple technique which enhances union of allograft to host bone taking advantage of the discrepancy in size between the adult allograft and the child’s bone. This involves lifting a flap of periosteum before resection from the host bone, which is then telescoped into the allograft medullary canal, which may require internal burring or splitting, for a distance of 1.5 to 2 cm and covering the bone junction with the periosteal flap. This is more stable than conventional end-to-end opposition. For each centimetre of telescoping the surface area available for bony union is increased more than three times. The periosteal flap also augments union. Additional surface fixation with a plate and screws is not necessary. We have used this technique in nine children, in eight of whom there was complete union at a mean of 16 weeks. Delayed union, associated with generalised limb osteoporosis, occurred in one. Early mobilisation, with weight-bearing by three weeks, was possible. There was only one fracture of the allograft


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 962 - 970
1 Jul 2007
Albert C Patil S Frei H Masri B Duncan C Oxland T Fernlund G

This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting. Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured. Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration/micromotion, and valgus/varus migration were significantly higher in the no-pressure group than in that subjected to pressure. These motion components correlated negatively with the mean area of cement and its contact with the endosteum. The presence of cement at the endosteum appears to play an important role in the initial stability of the implant following impaction allografting


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1425 - 1429
1 Nov 2006
Old AB McGrory BJ White RR Babikian GM

The use of allograft struts and cerclage wire, possibly augmented by plate fixation, for the treatment of Vancouver type-B1 peri-prosthetic fractures around a total hip replacement has been strongly advocated. We examined our results using plate fixation without allograft struts and compared them with the results of the use of struts alone or when combined with plate fixation. Of 20 consecutive patients with type-B1 fractures treated by open reduction and plate fixation, 19 were available for follow-up. The fractures healed in 18 patients with a mean time to weight-bearing of ten weeks (4 to 19). There were no cases of infection or malunion. Nonunion occurred in one patient and required a second plate fixation to achieve union. Safe, cost-effective treatment of Vancouver type-B1 fractures can be performed by plate fixation without the addition of cortical struts. This procedure may allow earlier weight-bearing than allograft strut fixation alone


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 51 - 55
1 Jan 2012
Masterson S Lidder S Scott G

We report the long-term results of revision total hip replacement using femoral impaction allografting with both uncemented and cemented Freeman femoral components. A standard design of component was used in both groups, with additional proximal hydroxyapatite coating in the uncemented group. A total of 33 hips in 30 patients received an uncemented component and 31 hips in 30 patients a cemented component. The mean follow-up was 9.8 years (2 to 17) in the uncemented group and 6.2 years (1 to 11) in the cemented group. Revision procedures (for all causes) were required in four patients (four hips) in the uncemented group and in five patients (five hips) in the cemented group. Harris hip scores improved significantly in both groups and were maintained independently of the extent of any migration of the femoral component within the graft or graft–cement mantle


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 962 - 965
1 Sep 2004
Ammon P Stockley I

A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement. Allograft bone was used in the second stage. Pathogenic organisms were identified in all patients. In stage 1, the prosthesis was removed together with infected tissue. Antibiotics were added to customised cement beads. Systemic antibiotics were not used. At the second stage, 45 of the patients had either acetabular impaction grafting, femoral impaction grafting or a combination; 12 had a massive allograft. Eight patients suffered recurrent infection (14%), in six with the original infecting organism. The risk factors for re-infection were multiple previous procedures and highly resistant organisms. We believe that systemic antibiotic therapy should be considered for these patients. Allograft bone is shown to be a useful adjunct in most infected hip replacements with considerable loss of bone stock


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 71 - 76
1 Jan 2010
Diklic ID Ganic ZD Blagojevic ZD Nho SJ Romeo AA

The treatment of a chronic posterior dislocation of the shoulder is often determined by the size of the associated impression fracture of the humeral head. Our hypothesis was that patients with a chronic unreduced posterior dislocation of the shoulder and a defect in the humeral head involving between 25% to 50% of the articular surface, would do better if reconstructed with an allograft from the femoral head rather than treated by a non-anatomical reconstruction. We reviewed ten men and three women with a mean age of 42 years (36 to 51) at a mean follow-up of 54 months (41 to 64) who had this procedure. At follow-up, nine had no pain or restriction of activities of daily living. Their mean Constant-Murley shoulder score was 86.8 (43 to 98). No patient had symptoms of instability of the shoulder. Reconstruction of the defect in the humeral head with an allograft provides good pain relief, stability and function for patients with a locked, chronic posterior dislocation where the defect involves between 25% and 50% of the circumference of the articular surface


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 576 - 582
1 Aug 1989
Doi K DeSantis G Singer D Hurley J O'Brien B McKay S Hickey M Murphy B

Five vascularised allografts of the knee joint were performed in dogs immunosuppressed with cyclosporin A and azathioprine. Three survived with normal function for 3 to 4 months after operation. One of the unsuccessful grafts had a failed vascular anastomosis, the other an inadequate blood level of cyclosporin A. All three successful grafts healed well. In two, bone scans, radiographs and biopsies were indistinguishable from successful autografts; in the third the blood supply to the graft failed despite patent anastomoses but the graft healed well with good function. All three grafts were rejected within 2 to 3 weeks of withdrawal of cyclosporin A and azathioprine. In non-immunosuppressed dogs, allografts of the knee, both vascularised and non-vascularised, were rejected within a few days of operation. In two non-vascularised allografts, administration of cyclosporin and azathioprine had no apparent effect on the rate of rejection of the graft


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 986 - 990
1 Sep 2004
Burnett RSJ Fornasier VL Haydon CM Wehrli BM Whitewood CN Bourne RB

We present the histological findings of an extensor mechanism allograft which was used in a total knee arthroplasty two years after implantation. Analysis of the graft was undertaken at four distinct anatomical levels and it was found to be incorporated into host tissue at each level. A wedge of fibrinoid necrosis, probably related to impingement of the graft on the tibial polyethylene insert, was seen. Impingement may play a role in the injury and necrosis of an allograft and may be one mode of failure in an extensor mechanism allograft


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1419 - 1423
1 Nov 2009
Emms NW Buckley SC Stockley I Hamer AJ Kerry RM

Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%). Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years. Acetabular reconstruction using irradiated allograft and a cemented acetabular component is an effective method of reconstruction, providing results in the medium- to long-term comparable with those of reported series where non-irradiated freshly-frozen bone was used


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 806 - 814
1 Sep 1995
Boyer M Danska J Nolan L Kiral A Bowen C

We compared growth in vascularised allograft transplants, autografts and in non-operated physes in rabbits immunosuppressed with cyclosporin A and in non-immunosuppressed animals. Molecular haplotyping was undertaken before operation to ensure allogenicity. Postoperative bone scans and fluorochrome labelling were used to confirm physeal vascularity. The animals were killed at three or five weeks. Proximal tibial physeal autografts, with or without cyclosporin A, or allografts with cyclosporin A, grew at similar rates to the physes of non-operated rabbits. All the operated physes grew at rates significantly greater than their contralateral controls. 99mTc-MDP bone scans accurately predicted the viability of the epiphyseal plate. Quantitative histomorphological analysis of the heights of the physeal proliferative and hypertrophic zones showed that successful physeal transplants have a normal appearance, but when unsuccessful have thickened hypertrophic zones compatible with physeal ischaemia. We discuss the significance of these results in relation to the transplantation of physes in children


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 190 - 193
1 Feb 2012
Koh Y Moon H Kim Y Park Y Jo S Kwon S

We compared extrusion of the allograft after medial and lateral meniscal allograft transplantation and examined the correlation between the extent of extrusion and the clinical outcome. A total of 73 lateral and 26 medial meniscus allografts were evaluated by MRI at a mean of 32 months (24 to 59) in 99 patients (67 men, 32 women) with a mean age of 35 years (21 to 52). The absolute values and the proportional widths of extruded menisci as a percentage were measured in coronal images that showed maximum extrusion. Functional assessments were performed using Lysholm scores. The mean extrusion was 4.7 mm (1.8 to 7.7) for lateral menisci and 2.9 mm (1.2 to 6.5) for medial menisci (p < 0.001), and the mean percentage extrusions were 52.0% (23.8% to 81.8%) and 31.2% (11.6% to 63.4%), respectively (p < 0.001). Mean Lysholm scores increased significantly from 49.0 (10 to 83) pre-operatively to 86.6 (33 to 99) at final follow-up for lateral menisci (p = 0.001) and from 50.9 (15 to 88) to 88.3 (32 to 100) for medial menisci (p < 0.001). The final mean Lysholm scores were similar in the two groups (p = 0.312). Furthermore, Lysholm scores were not found to be correlated with degree of extrusion (p = 0.242). Thus, transplanted lateral menisci extrude more significantly than transplanted medial menisci. However, the clinical outcome after meniscal transplantation was not found to be adversely affected by extrusion of the allograft


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 213 - 216
1 Mar 1996
Alexeeff M Mahomed N Morsi E Garbuz D Gross A Latner AJ

We report 11 patients having revision of total hip arthroplasty using massive structural allografts for failure due to sepsis and associated bone loss. All patients had a two-stage reconstruction and the mean follow-up was 47.8 months (24 to 72). Positive cultures were obtained at the first stage in nine of the 11 patients, with Staphylococcus epidermidis being the most common organism. The other two patients had draining sinuses with negative cultures. There was no recurrence of infection in any patient. The mean increase in the modified Harris hip score was 45 and all the grafts appeared to have united to host bone. Two patients required additional procedures, but only one was related to the allograft. Complications included an incomplete sciatic nerve palsy and one case of graft resorption. Our results support the use of massive allografts in failed septic hip arthroplasty in which there is associated bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1580 - 1584
1 Dec 2008
Winkler H Stoiber A Kaudela K Winter F Menschik F

Infection of a total hip replacement (THR) requires component removal and thorough local debridement. Usually, long-term antibiotic treatment in conjunction with a two-stage revision is required. This may take several months. One-stage revision using antibiotic-loaded cement has not gained widespread use, although the clinical and economic advantages are obvious. Allograft bone may be impregnated with high levels of antibiotics, and in revision of infected THR, act as a carrier providing a sustained high local concentration. We performed 37 one-stage revision of infected THRs, without the use of cement. There were three hips which required further revision because of recurrent infection, the remaining 34 hips (92%) stayed free from infection and stable at a mean follow-up of 4.4 years (2 to 8). No adverse effects were identified. Incorporation of bone graft was comparable with unimpregnated grafts. Antibiotic-impregnated allograft bone may enable reconstruction of bone stock, insertion of an uncemented implant and control of infection in a single operation in revision THR for infection


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 670 - 675
1 May 2009
Agholme F Aspenberg P

Soaking bone grafts in a bisphosphonate solution before implantation can prevent their resorption and increase the local bone density in rats and humans. However, recent studies suggest that pre-treatment of allografts with bisphosphonate can prevent bone ingrowth into impaction grafts. We tested the hypothesis that excessive amounts of bisphosphonate would also cause a negative response in less dense grafts. We used a model where non-impacted metaphyseal bone grafts were randomised into three groups with either no bisphosphonate, alendronate followed by rinsing, and alendronate without subsequent rinsing, and inserted into bone chambers in rats. The specimens were evaluated histologically at one week, and by histomorphometry and radiology at four weeks. At four weeks, both bisphosphonate groups showed an increase in the total bone content, increased newly formed bone, and higher radiodensity than the controls. In spite of being implanted in a chamber with a limited opportunity to diffuse, even an excessive amount of bisphosphonate improved the outcome. We suggest that the negative results seen by others could be due to the combination of densely compacted bone and a bisphosphonate. We suggest that bisphosphonates are likely to have a negative influence where resorption is a prerequisite to create space for new bone ingrowth


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 337 - 343
1 Apr 2004
Graham NM Stockley I

Between April 1992 and November 1998 we used 34 massive proximal femoral allografts for femoral reconstruction at revision hip arthroplasty. Seven patients have died and two have been lost to follow-up. There were thus 25 grafts in 24 patients for review. The mean follow-up was 53 months (16 to 101). By the time of the review two patients had undergone a further revision for failure of the allograft. Another had required secondary plating and grafting at the graft-host junction for symptomatic nonunion. One had recurrence of deep sepsis and was being managed conservatively. Trochanteric union was considered to have occurred radiologically in 16 of the 25 grafts and union at the host-graft junction in 20. Resorption of the allograft was significant in only two hips. We recommend this technique in cases in which femoral bone loss has been catastrophic


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 106 - 109
1 Jan 1999
Govender S Parbhoo AH

Fresh-frozen allografts from the humerus were used to help to stabilise the spine after anterior decompression for tuberculosis in 47 children with a mean age of 4.2 years (2 to 9). The average angle of the gibbus, before operation, was 53°; at follow-up, two years later, it was 15°. Rejection of the graft or deep sepsis was not seen. Cross trabeculation between the allograft and the vertebral body was observed at six months, with remodelling occurring at approximately 30 months


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1000 - 1004
1 Aug 2008
Wraighte PJ Howard PW

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). The median pre-operative bone defect score was 3 (interquartile range (IQR) 2 to 3) using the Endo-Klinik classification. The median subsidence at one year post-operatively was 2 mm (IQR 1 to 3). At the final review the median Harris hip score was 80.6 (IQR 67.6 to 88.9) and the median subsidence 2 mm (IQR 1 to 4). Incorporation of the allograft into trabecular bone and secondary remodelling were noted radiologically at the final follow-up in 87% (393 of 452 zones) and 40% (181 of 452 zones), respectively. Subsidence of the Exeter stem correlated with the pre-operative Endo-Klinik bone loss score (p = 0.037). The degree of subsidence at one year had a strong association with long-term subsidence (p < 0.001). There was a significant correlation between previous revision surgery and a poor Harris Hip score (p = 0.028), and those who had undergone previous revision surgery for infection had a higher risk of complications (p = 0.048). Survivorship at 10.5 years with any further femoral operation as the end-point was 92% (95% confidence interval 82 to 97)


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 167 - 172
1 Feb 2012
Buttaro MA Costantini J Comba F Piccaluga F

We determined the midterm survival, incidence of peri-prosthetic fracture and the enhancement of the width of the femur when combining struts and impacted bone allografts in 24 patients (25 hips) with severe femoral bone loss who underwent revision hip surgery. The pre-operative diagnosis was aseptic loosening in 16 hips, second-stage reconstruction in seven, peri-prosthetic fracture in one and stem fracture in one hip. A total of 14 hips presented with an Endoklinik grade 4 defect and 11 hips a grade 3 defect. The mean pre-operative Merle D’Aubigné and Postel score was 5.5 points (1 to 8). The survivorship was 96% (95% confidence interval 72 to 98) at a mean of 54.5 months (36 to 109). The mean functional score was 17.3 points (16 to 18). One patient in which the strut did not completely bypass the femoral defect was further revised using a long cemented stem due to peri-prosthetic fracture at six months post-operatively. The mean subsidence of the stem was 1.6 mm (1 to 3). There was no evidence of osteolysis, resorption or radiolucencies during follow-up in any hip. Femoral width was enhanced by a mean of 41% (19% to 82%). A total of 24 hips had partial or complete bridging of the strut allografts. This combined biological method was associated with a favourable survivorship, a low incidence of peri-prosthetic fracture and enhancement of the width of the femur in revision total hip replacement in patients with severe proximal femoral bone loss


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 771 - 779
1 Jun 2015
te Stroet MAJ Rijnen WHC Gardeniers JWM van Kampen A Schreurs BW

We report the clinical and radiographic outcomes of 208 consecutive femoral revision arthroplasties performed in 202 patients (119 women, 83 men) between March 1991 and December 2007 using the X-change Femoral Revision System, fresh-frozen morcellised allograft and a cemented polished Exeter stem. All patients were followed prospectively. The mean age of the patients at revision was 65 years (30 to 86). At final review in December 2013 a total of 130 patients with 135 reconstructions (64.9%) were alive and had a non re-revised femoral component after a mean follow-up of 10.6 years (4.7 to 20.9). One patient was lost to follow-up at six years, and their data were included up to this point. Re-operation for any reason was performed in 33 hips (15.9%), in 13 of which the femoral component was re-revised (6.3%). The mean pre-operative Harris hip score was 52 (19 to 95) (n = 73) and improved to 80 (22 to 100) (n = 161) by the last follow-up. Kaplan–Meier survival with femoral re-revision for any reason as the endpoint was 94.9% (95% confidence intervals (CI) 90.2 to 97.4) at ten years; with femoral re-revision for aseptic loosening as the endpoint it was 99.4% (95% CI 95.7 to 99.9); with femoral re-operation for any reason as the endpoint it was 84.5% (95% CI 78.3 to 89.1); and with subsidence ≥ 5 mm it was 87.3% (95% CI 80.5 to 91.8). Femoral revision with the use of impaction allograft bone grafting and a cemented polished stem results in a satisfying survival rate at a mean of ten years’ follow-up. Cite this article: Bone Joint J 2015; 97-B:771–9


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 904 - 913
1 Nov 1993
Hernigou P Delepine G Goutallier D Julieron A

From 1984 to 1988 we implanted 127 massive allografts irradiated with a dose of 25,000 grays. These were reviewed at a minimum follow-up of three years to determine the effect of irradiation on infection, the complications and the functional result. No bacteriological infection was seen in the 44 patients who had allografts for revision of joint arthroplasty or for a tumour with no adjuvant therapy. For the 83 patients who also had chemotherapy or radiotherapy or both for a bone tumour, the rate of infection was 13%. The major mechanical complications were nonunion in seven grafts (5.5%) and fracture in eight (6%). These rates do not differ greatly from those reported for non-irradiated grafts. Our results suggest that irradiation, which remains the most convenient and acceptable method of sterilisation, does not jeopardize the clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 865 - 869
1 Jul 2006
Comba F Buttaro M Pusso R Piccaluga F

We reviewed the clinical and radiological results of 131 patients who underwent acetabular revision for aseptic loosening with impacted bone allograft and a cemented acetabular component. The mean follow-up was 51.7 months (24 to 156). The mean post-operative Merle D’Aubigné and Postel scores were 5.7 points (4 to 6) for pain, 5.2 (3 to 6) for gait and 4.5 (2 to 6) for mobility. Radiological evaluation revealed migration greater than 5 mm in four acetabular components. Radiological failure matched clinical failure. Asymptomatic radiolucent lines were observed in 31 of 426 areas assessed (7%). Further revision was required in six patients (4.5%), this was due to infection in three and mechanical failure in three. The survival rate for the reconstruction was 95.8% (95% confidence interval 92.3 to 99.1) overall, and 98%, excluding revision due to sepsis. Our study, from an independent centre, has reproduced the results of the originators of the method


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 63 - 67
1 Jan 1990
Jasty M Harris W

We evaluated 38 hip reconstructions in 36 patients at a mean follow-up of 5.9 years (range 4 to 9.1) after femoral head allografts had been used to augment severely deficient acetabular bone stock. The patients were all relatively young and had many previous operations. Their pre-operative Harris hip rating averaged 46 points (range 18 to 73). All the allografts united and there were no infections. However, 12 acetabular components (32%) became loose; six of these had needed revision using the healed allograft, and two hips had required resection arthroplasty. The 30 surviving hips had a mean Harris hip score of 82 points. Some radiographic evidence of graft resorption was seen in 23 hips, though this was mild in 17. The extent of cover provided by the allograft and the severity of graft resorption both correlated with acetabular loosening. Although structural allografts had allowed successful hip reconstructions in many of these patients with major bone loss, the failure rate had increased from zero at four years to 32% at six years; clearly they provide only a short-term solution


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 887 - 892
1 Nov 1992
Muscolo D Petracchi L Ayerza M Calabrese M

Six massive femoral allografts followed up for 22 to 36 years are described. Three were intercalary, two were osteoarticular and one was a total femoral replacement. Their functional rating according to the Musculoskeletal Tumor Society System (Enneking 1987) averaged 82% (56 to 100). The radiographic score averaged 75% (48 to 100). Four allografts had suffered fractures, but three of these had later united to give good final scores. Our study shows that massive femoral allografts can function well for as long as 36 years


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 205 - 212
1 Mar 1995
Goertzen M Clahsen H Burrig K Schulitz K

Bone-ACL-bone allograft transplantation is a potential solution to the problem of reconstruction of the anterior cruciate ligament (ACL), but sterilisation by gamma irradiation or ethylene oxide causes degradation of the graft. We have studied the biomechanical and histological properties of deep-frozen canine bone-ACL-bone allografts sterilised by gamma irradiation (2.5 Mrad) under argon gas protection. Particular attention was paid to their collagen structure and neuroanatomy compared with those of non-irradiated allografts. We used 60 skeletally mature foxhounds. In 30 animals one ACL was replaced by an irradiated allograft and in the other 30 a non-irradiated graft was used. In both groups the graft was augmented by a Kennedy Ligament Augmentation Device. Examination of the allografts at 3, 6 and 12 months after implantation included mechanical testing, histology, collagen morphometry, neuroanatomical morphology (silver and gold chloride stain) and studies of the microvasculature (modified Spalteholz technique). At 12 months the irradiated ACL allografts failed at a mean maximum load of 718.3 N, 63.8% of the strength of the normal canine ACL. The non-irradiated allografts failed at 780.1 N, 69.1% of normal. All the allografts showed a well-orientated collagen structure one year after transplantation and there was no difference between the irradiated grafts and the others. The silver staining technique demonstrated Golgi tendon organs and free nerve endings within both groups of allografts. As in the normal ACL these structures were most commonly found near the surface of the graft and at its bony attachments. At 12 months the irradiated allografts showed slight hypervascularity compared with the non-irradiated grafts.(ABSTRACT TRUNCATED AT 250 WORDS)


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 595 - 599
1 Jul 1991
Power R Wood D Tomford W Mankin H

The early results of revision osteoarticular allografts in weight-bearing joints are reported. Sixteen consecutive patients underwent surgery over a six-year period between 1982 and 1988. At the time of review eight patients (50%) had surviving second allografts with an average follow-up time of 48 months (range 12 to 87). Five patients were graded excellent according to the Mankin scale, one good and two fair. Eight patients (50%) required further surgery, but only two patients came to amputation


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1009 - 1014
1 Sep 2002
Deijkers RLM Bloem RM Hogendoorn PCW Verlaan JJ Kroon HM Taminiau AHM

Low-grade surface tumours of bone may theoretically be treated by hemicortical resection, retaining part of the circumference of the cortex. An inlay allograft may be used to reconstruct the defect. Since 1988 we have performed 22 hemicortical procedures in selected patients with low-grade parosteal osteosarcoma (6), peripheral chondrosarcoma (6) and adamantinoma (10). Restricted medullary involvement was not a contraindication for this procedure. There was no evidence of local recurrence or distant metastasis at a mean follow-up of 64 months (27 to 135). Wide resection margins were obtained in 19 patients. All allografts incorporated completely and there were no fractures or infections. Fractures of the remaining hemicortex occurred in six patients and were managed successfully by casts or by osteosynthesis. The functional results were excellent or good in all except one patient. Hemicortical procedures for selected cases of low-grade surface tumours give excellent oncological and functional outcomes. There was complete remodelling and fewer complications when compared with larger intercalary procedures. The surgery is technically demanding but gives good clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 333 - 335
1 Mar 1999
Palmer SH Gibbons CLMH Athanasou NA

We analysed the histological findings in 1146 osteoarthritic femoral heads which would have been considered suitable for bone-bank donation to determine whether pathological lesions, other than osteoarthritis, were present. We found that 91 femoral heads (8%) showed evidence of disease. The most common conditions noted were chondrocalcinosis (63 cases), avascular necrosis (13), osteomas (6) and malignant tumours (one case of low-grade chondrosarcoma and two of well-differentiated lymphocytic lymphoma). There were two with metabolic bone disease (Paget’s disease and hyperparathyroid bone disease) and four with inflammatory (rheumatoid-like) arthritis. Our findings indicate that occult pathological conditions are common and it is recommended that histological examination of this regularly used source of bone allograft should be included as part of the screening protocol for bone-bank collection


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 105 - 110
1 Jan 1992
Beaver R Mahomed M Backstein D Davis A Zukor D Gross A

Fresh osteochondral allografts were used to repair post-traumatic osteoarticular defects in 92 knees. At the time of grafting, varus or valgus deformities were corrected by upper tibial or supracondylar femoral osteotomies. A survivorship analysis was performed in which failure was defined as the need for a revision operation or the persistence of the pre-operative symptoms. There was a 75% success rate at five years, 64% at ten years and 63% at 14 years. The failure rate was higher for bipolar grafts than for unipolar and the results in patients over the age of 60 years were poor. The outcome did not depend on the sex of the patient and the results of allografts in the medial and lateral compartments of the knee were similar. Careful patient selection, correction of joint malalignment by osteotomy, and rigid fixation of the graft are all mandatory requirements for success. We recommend this method for the treatment of post-traumatic osteochondral defects in the knees of relatively young and active patients


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1674 - 1681
1 Dec 2016
Verdegaal SHM van Rijswijk CS Brouwers HFC Dijkstra PDS van de Sande MAJ Hogendoorn PCW Taminiau AHM

Aims. The purpose of this retrospective study was to differentiate between the MRI features of normal post-operative change and those of residual or recurrent disease after intralesional treatment of an atypical cartilage tumour (ACT)/grade I chondrosarcoma. Patients and Methods. We reviewed the case notes, radiology and histology of 75 patients, who had been treated for an ACT/grade I chondrosarcoma by curettage, phenolisation and bone allografting between 1994 and 2005. The first post-operative Gd-enhanced MRI scan was carried out within one year of surgery. Patients had a minimum of two scans and a mean follow-up of 72 months (13 to 169). Further surgery was undertaken in cases of suspected recurrence. Results. In 14 patients (18.6%) a second procedure was undertaken after a mean period of 59 months (8 to 114). Radio frequency ablation (RFA) was used in lesions of < 10 mm and curettage, phenolisation and bone grafting for those ≥ 10 mm. Only six of these (8% of total) had a histologically-proven recurrence. No increase in tumour grade was seen at time of recurrence. Conclusion. Based on this study, we have been able to classify the post-operative MRI appearances into four groups. These groups differ in follow-up, and have a different risk of recurrence of the lesion. Follow-up and treatment vary for the patients in each group. We present a flow diagram for the appropriate and safe follow-up for this specific group of patients. Cite this article: Bone Joint J 2016;98-B:1674–81


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 14 - 21
1 Jan 1993
Gie G Linder L Ling R Simon J Slooff T Timperley A

We report the results of using impacted cancellous allografts and cement for fixation of the femoral component when revision arthroplasty is required in the face of lost bone stock. In 56 hips reviewed after 18 to 49 months there were few complications and a majority of satisfactory results with evidence of incorporation of the graft. Further study and review are necessary, but the use of the method appears to be justified


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 431 - 434
1 May 1988
Dodd C Fergusson C Freedman L Houghton G Thomas D

The results of a study of the use of autograft versus allograft bone in the surgery of idiopathic adolescent scoliosis are presented. Two groups of patients, matched for age, sex, level and angle of curve, received bone grafts, 20 patients having autogenous bone from the iliac crest and the other 20 having donor bone from a bone bank. Both groups had otherwise identical posterior fusions and Harrington instrumentation. There was no difference between the two groups in a blind, radiographic assessment of bone graft mass at six months, nor in maintenance of the curve correction over the same period. No major operative complications nor failures of instrumentation were encountered. There was, however, a marked reduction in operative time and blood loss in the patients receiving donor bone and also a much lower incidence of late symptoms relating to the operative sites. We conclude that, even in the presence of adequate iliac crest, the use of bank bone is superior for grafting in idiopathic scoliosis surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 538 - 544
1 May 1999
Deijkers RLM Bouma GJ van der Meer-Prins EMW Huysmans PE Taminiau AHM Claas FHJ

We analysed the cellular immune response in ten transplantations of different massive bone allografts, of which five had a poor clinical outcome. Cytotoxic T lymphocytes (CTL) and T helper lymphocytes (TH) against mismatched donor antigens were found in all patients. More importantly, CTL with a high affinity for donor antigens were found in five cases. High-affinity CTL need no CD8 molecule to stabilise the antigen binding and are strongly associated with rejection of heart and corneal transplants. Even after removal of most of the bone-marrow cells, we found high-affinity CTL and high TH frequencies. This T-cell response could be detected over a period of years. We conclude that frozen bone allografts can induce high-affinity donor-specific CTL. The present assay allows qualification and quantification of the levels of CTL and TH in the blood. This approach may be helpful in studying the effect of the immune response on the outcome of the graft


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 342 - 344
1 Mar 1999
Hamer AJ Stockley I Elson RA

Secondary sterilisation of allograft bone by gamma irradiation is common, but the conditions under which it is performed vary between tissue banks. Some do so at room temperature, others while the bone is frozen. Bone is made brittle by irradiation because of the destruction of collagen alpha chains, probably mediated by free radicals generated from water molecules. Freezing reduces the mobility of water molecules and may therefore decrease the production of free radicals. We found that bone irradiated at −78°C was less brittle and had less collagen damage than when irradiated at room temperature. These findings may have implications for bone-banking


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 363 - 368
1 May 1996
Hamer AJ Strachan JR Black MM Ibbotson CJ Stockley I Elson RA

There have been conflicting reports on the effects of gamma irradiation on the material properties of cortical allograft bone. To investigate changes which result from the method of preparation, test samples must be produced with similar mechanical properties to minimise variations other than those resulting from treatment. We describe a new method for the comparative measurement of bone strength using standard bone samples. We used 233 samples from six cadavers to study the effects of irradiation at a standard dose (28 kGy) alone and combined with deep freezing. We also investigated the effects of varying the dose from 6.8 to 60 kGy (n = 132). None of the treatments had any effect on the elastic behaviour of the samples, but there was a reduction in strength to 64% of control values (p < 0.01) after irradiation with 28 kGy. There was also a dose-dependent reduction in strength and in the ability of the samples to absorb work before failure. We suggest that irradiation may cause an alteration in the bone matrix of allograft bone, but provided it is used in situations in which loading is within its elastic region, then failure should not occur


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 740 - 744
1 Sep 1994
Azuma T Yasuda H Okagaki K Sakai K

We report the results of 24 acetabular reconstructions in which cemented polyethylene cups and tamped corticocancellous allografts were used for severe acetabular bone deficiency. Eleven hips had type-II (cavitary) bone deficiency and 13 had type-III (combined) defects. At a mean follow-up of 5.8 years, two components had migrated more than 5 mm and had accompanying radiolucent zones of more than 2 mm width. A radiolucency 5 mm wide was also seen in zone III of an acetabular implant which had not migrated. None of the patients had required revision because of loosening or infection


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 643 - 646
1 Jul 1990
Mulroy R Mankin H Harris W

We describe a patient in whom a total hip replacement had failed and who subsequently fractured her proximal femur. The prosthetic hip and the surrounding bone were excised and replaced by a matched pair of allograft components. She obtained seven years of pain free hip function before the graft showed radiographic signs of failure; it was then replaced by a new prosthetic hip


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 791 - 794
1 Sep 1991
Guo M Xia Z Lin L

We studied the calcium content and mechanical strength of cortical bone from rats and dogs after different periods of demineralisation, showing that the rate of demineralisation differed considerably between the species. Specimens from the rat were further treated by chemical extraction and autolysis and tested for osteoinductive properties. We showed that partially demineralised cortical bone retained adequate mechanical strength, while retaining the biological effects of completely demineralised bone. This shows that it is possible to prepare allografts which have adequate mechanical strength and still retain osteo-inductive properties


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 544 - 549
1 May 2002
Piccaluga F Valle AD Fernández JCE Pusso R

Impacted morcellised bone allograft and a Charnley stem was used to revise 59 loose femoral components in 57 consecutive patients. Femoral bone loss was rated as Endo-Klinik grade 2 in nine patients, grade 3 in 41, and grade 4 in nine. The immediate postoperative radiographs and those taken at the most recent follow-up were compared for radiolucencies, subsidence and incorporation of the graft. One patient was lost to follow-up and two were not available for radiological analysis. The mean clinical follow-up in 58 procedures was 56.7 months (24 to 144) and the mean radiological review of 56 reconstructions was 54.4 months (24 to 144). An intraoperative femoral fracture occurred in one patient (1.7%) and was successfully treated by strut grafting and cerclage wiring. Extrusion of cement through perforations or incomplete hoop fractures was detected in the postoperative radiographs of ten procedures (17%); none of these patients sustained a complete fracture. Three patients had dislocations (5%) and two (3.5%) developed painful subsidence of the stem which required a further revision. The latest follow-up radiographs in 56 reconstructions showed a well fixed stem and radiological healing of the graft in 52 (93%), and definite loosening in four (7%). Of these four, two were revised again and two were asymptomatic after a follow-up of 120 months each. The mean subsidence in the 52 successful revisions was 0.38 mm (0 to 4). Impaction allografting with a Charnley stem restored bone stock and provided adequate fixation of the stem in 93% of the hips. There was a low rate of rerevision (3.5%) and a low incidence of intraoperative and postoperative complications


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 135 - 142
1 Jan 1999
Kärrholm J Hultmark P Carlsson L Malchau H

We revised 24 consecutive hips with loosening of the femoral stem using impaction allograft and a cemented stem with an unpolished proximal surface. Repeated radiostereometric examinations for up to two years showed a slow rate of subsidence with a mean of 0.32 mm (−2.0 to +0.31). Fifteen cases followed for a further year showed the same mean subsidence after three years, indicating stabilisation. A tendency to retroversion of the stems was noted between the operation and the last follow-up. Retroversion was also recorded when displacement of the stem was studied in ten of the patients after two years. Repeated determination of bone mineral density showed an initial loss after six months, followed by recovery to the postoperative level at two years. Defects in the cement mantle and malalignment of the stem were often noted on postoperative radiographs, but did not correlate with the degrees of migration or displacement. After one year, increasing frequency of trabecular remodelling or resorption of the graft was observed in the greater trochanter and distal to the tip of the stem. Cortical repair was noted distally and medially (Gruen regions 3, 5 and 6). Migration of the stems was the lowest reported to date, which we attribute to the improved grafting technique and to the hardness of the graft


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 74 - 80
1 Jan 1989
Wakitani S Kimura T Hirooka A Ochi T Yoneda M Yasui N Owaki H Ono K

In an attempt to repair articular cartilage, allograft articular chondrocytes embedded in collagen gel, were transplanted into full-thickness defects in rabbit articular cartilage. Twenty-four weeks after the transplantation, the defects were filled with hyaline cartilage, specifically synthesising Type II collagen. These chondrocytes were autoradiographically proven to have originated from the transplanted grafts. Assessed histologically the success rate was about 80%, a marked improvement over the results reported in previous studies on chondrocyte transplantation without collagen gel. By contrast, the defects without chondrocyte transplantation healed with fibrocartilage. Immunological enhancement induced by transplanted allogenic chondrocytes or collagen was not significant at eight weeks after treatment, so far as shown by both direct and indirect blastformation reactions. Thus, allogenic transplantation of isolated chondrocytes embedded in collagen gel appears to be one of the most promising methods for the restoration of articular cartilage


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 862 - 864
1 Nov 1995
Franzen H Toksvig-Larsen S Lidgren L Onnerfalt R

We report the preliminary findings of the use of roentgen stereophotogrammetric analysis to evaluate the early migration of five femoral components after revision for mechanical loosening using impacted cancellous allograft and cement. All hips were examined at one week, four to six months and one year after surgery. All the components subsided by 0.4 to 4.9 mm during the first year. In four hips the prosthetic head was displaced 1.1 to 6.9 mm posteriorly. Fixation of the femoral components was less secure than after primary arthroplasty but the incidence and magnitude of early migration were similar to those after revision with cement alone


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 310 - 313
1 Mar 2005
Buckley SC Stockley I Hamer AJ Kerry RM

We report the results of the revision of 123 acetabular components for aseptic loosening treated by impaction bone grafting using frozen, morsellised, irradiated femoral heads and cemented sockets. This is the first large series using this technique to be reported. A survivorship of 88% with revision as the end-point after a mean of five years is comparable with that of other series.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 559 - 559
1 May 1998
McMinn D


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 935 - 935
1 Sep 1999
SIDDIQUI SA LIPTON J BRYK E VIGORITA V EVANGALISTA J


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 178 - 180
1 Mar 1997
Norman-Taylor FH Villar RN


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 151 - 152
1 Jan 1990
Nelson I Bulstrode C Mowat A


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1363 - 1369
1 Oct 2010
Garcia-Cimbrelo E Garcia-Rey E Cruz-Pardos A Madero R

Revision surgery of the hip was performed on 114 hips using an extensively porous-coated femoral component. Of these, 95 hips (94 patients) had a mean follow-up of 10.2 years (5 to 17). No cortical struts were used and the cortical index and the femoral cortical width were measured at different levels.

There were two revisions for aseptic loosening. Survivorship at 12 years for all causes of failure was 96.9% (95% confidence interval 93.5 to 100) in the best-case scenario. Fibrous or unstable fixation was associated with major bone defects. The cortical index (p = 0.045) and the lateral cortical thickness (p = 0.008) decreased at the proximal level over time while the medial cortex increased (p = 0.001) at the proximal and distal levels. An increase in the proximal medial cortex was found in patients with an extended transtrochanteric osteotomy (p = 0.026) and in those with components shorter than 25 cm (p = 0.008).

The use of the extensively porous-coated femoral component can provide a solution for difficult cases in revision surgery. Radiological bony ingrowth is common. Although without clinical relevance at the end of follow-up, the thickness of the medial femoral cortex often increased while that of the lateral cortex decreased. In cases in which a shorter component was used and in those undertaken using an extended trochanteric osteotomy, there was a greater increase in thickness of the femoral cortex over time.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 350 - 351
1 May 1994
Michaud R Drabu K


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1124 - 1132
1 Nov 2004
Tsiridis E Narvani AA Haddad FS Timperley JA Gie GA

We reviewed retrospectively the outcome of the treatment by impaction grafting of periprosthetic femoral fractures around loose stems in 106 patients with Vancouver type-B2 and type-B3 fractures. Eighty-nine patients had a cemented revision with impaction grafting and a long or short stem. The remaining 17 had cemented revision without impaction grafting.

Fractures treated by impaction grafting and a long stem were more than five times likely to unite than those treated by impaction grafting and a short stem (odds ratio = 5.5, 95% confidence interval (CI) 1.54 to 19.6; p = 0.009). Furthermore, those with impaction grafting and a long stem were significantly more likely to unite than those with a long stem without impaction grafting (odds ratio = 4.07, 95% CI 1.10 to 15.0; p = 0.035).

There was also a trend towards a higher rate of union in those treated by impaction grafting than in those without (odds ratio = 2.69, 95% CI 0.86 to 8.45; p = 0.090).

Impaction grafting is being increasingly widely used for the restoration of femoral bone stock. It can be successfully applied to periprosthetic femoral fractures but a long stem should be used to bypass the distal fracture line.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 771 - 776
1 Jul 2004
Frei H Mitchell P Masri BA Duncan CP Oxland TR

We studied various aspects of graft impaction and penetration of cement in an experimental model. Cancellous bone was removed proximally and local diaphyseal lytic defects were simulated in six human cadaver femora. After impaction grafting the specimens were sectioned and prepared for histomorphometric analysis.

The porosity of the graft was lowest in Gruen zone 4 (52%) and highest in Gruen zone 1 (76%). At the levels of Gruen zones 6 and 2 the entire cross-section was almost filled with cement. Cement sometimes reached the endosteal surface in other Gruen zones. The mean peak impaction forces exerted with the impactors were negatively correlated with the porosity of the graft.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 29 - 35
1 Jan 1986
Aston J Bentley G

Allografts of intact cartilage, isolated chondrocytes and cultured chondrocytes taken from the epiphysial growth-plate and from the articular surface of immature rabbits were inserted into full thickness defects in the tibial articular surface of 160 mature rabbits. In the contralateral knees, which were used as controls, similar defects were made but no grafts were inserted. Grafts were followed up for periods of up to one year after transplantation. Both intact articular and intact growth-plate grafts produced significantly better repair than that seen in control ungrafted defects in normal joints (P less than 0.01 and P less than 0.05 respectively) and in arthritic joints (P less than 0.01). Cultured chondrocytes cut to a precise fit also produced significantly better repair than ungrafted defects in arthritic joints (P less than 0.05).


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 595 - 599
1 Jul 1998
Galea G Kopman D Graham BJM

The Scottish National Blood Transfusion Service is the main provider of bone for grafting in Scotland. Bone is procured only from live donors, following very strict selection criteria, and we have investigated whether the amount being collected was adequate.

Our current harvest of approximately 1700 femoral heads per year is shown not to be enough to meet the future demand for revision surgery of the hip. Many more of these operations are being undertaken, and impaction grafting is being used increasingly.

We have calculated the predicted rates of collection and usage for the next four to five years so that we can expand our service in a controlled fashion.