Advertisement for orthosearch.org.uk
Results 1 - 100 of 498
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 821 - 824
1 Jun 2012
Fushimi K Miyamoto K Fukuta S Hosoe H Masuda T Shimizu K

There have been few reports regarding the efficacy of posterior instrumentation alone as surgical treatment for patients with pyogenic spondylitis, thus avoiding the morbidity of anterior surgery. We report the clinical outcomes of six patients with pyogenic spondylitis treated effectively with a single-stage posterior fusion without anterior debridement at a mean follow-up of 2.8 years (2 to 5). Haematological data, including white cell count and level of C-reactive protein, returned to normal in all patients at a mean of 8.2 weeks (7 to 9) after the posterior fusion. Rigid bony fusion between the infected vertebrae was observed in five patients at a mean of 6.3 months (4.5 to 8) post-operatively, with the remaining patient having partial union. Severe back pain was immediately reduced following surgery and the activities of daily living showed a marked improvement. Methicillin-resistant Staphylococcus aureus was detected as the causative organism in four patients. Single-stage posterior fusion may be effective in patients with pyogenic spondylitis who have relatively minor bony destruction


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 172 - 179
1 Feb 2023
Shimizu T Kato S Demura S Shinmura K Yokogawa N Kurokawa Y Yoshioka K Murakami H Kawahara N Tsuchiya H

Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model. Results. A total of 44 patients (32.4%) developed IF at a median of 31 months (interquartile range 23 to 74) following TES. Most IFs were rod fractures preceded by a mean CS of 6.1 mm (2 to 18) and LA kyphotic enhancement of 10.8° (-1 to 36). IF-free survival rates were 75.8% at five years and 56.9% at ten years. The interval from TES to IF peaked at two to three years postoperatively and continued to occur over a period of time thereafter; the early IF-developing group had greater CS at one month postoperatively (CS1M) and more lumbar TES. CS1M ≥ 3 mm and sole use of frozen autografts were identified as independent risk factors for IF. Conclusion. IF is a common complication following TES. We have demonstrated that robust spinal reconstruction preventing CS, and high-quality bone grafting are necessary for successful reconstruction. Cite this article: Bone Joint J 2023;105-B(2):172–179


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 982 - 989
1 Nov 1991
McMaster M

Adolescent idiopathic scoliosis in 152 patients was treated by Luque L-rod instrumentation and early mobilisation without external support. This series was compared with a matched group of 156 patients treated by Harrington instrumentation and immobilised in an underarm jacket for nine months. All the operations in both groups were performed by one surgeon and the patients were followed prospectively for more than two years. Correction of the scoliosis in the frontal plane was similar in both groups. However, the normal sagittal contour was better maintained with Luque rods, especially in the thoracolumbar and lumbar regions, and provided less loss of correction than with Harrington rods. Neither method significantly derotated the scoliosis. All the patients with Luque instrumentation developed a solid fusion despite breakage of the sublaminar wires at one or two levels in 4.9%. There were no major neurological complications with either type of instrumentation


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1067 - 1072
1 Sep 2022
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Charalampidis A Nietosvaara Y Helenius I

Aims. The aim of this study was to evaluate whether, after correction of an adolescent idiopathic scoliosis (AIS), leaving out the subfascial drain gives results that are no worse than using a drain in terms of total blood loss, drop in haemoglobin level, and opioid consumption. Methods. Adolescents (aged between 10 and 21 years) with an idiopathic scoliosis (major curve ≥ 45°) were eligible for inclusion in this randomized controlled noninferiority trial (n = 125). A total of 90 adolescents who had undergone segmental pedicle screw instrumentation were randomized into no-drain or drain groups at the time of wound closure using the sealed envelope technique (1:1). The primary outcome was a drop in the haemoglobin level during first three postoperative days. Secondary outcomes were 48-hour postoperative oxycodone consumption and surgical complications. Results. All 90 patients were included in the primary outcome analysis (no drain = 43; drain = 47). The mean total postoperative blood loss (intraoperative and drain output) was significantly higher in the group with a subfascial drain than in the no-drain group (1,008 ml (SD 520) vs 631 ml (SD 518); p < 0.001). The drop in haemoglobin level did not differ between the study groups over the postoperative timepoints (p = 0.290). The 48-hour opioid consumption was significantly higher in the no-drain group (2.0 mg/kg (SD 0.9) vs 1.4 (SD 0.6); p = 0.005). Two patients in the no-drain and one patient in the drain group developed a surgical site infection. Conclusion. Leaving the subfascial drain out after pedicle screw instrumentation for AIS is not associated with higher postoperative haemoglobin levels. Patients treated without a subfascial drain needed 30% more opioids during the first 48 hours than those who had a drain. Cite this article: Bone Joint J 2022;104-B(9):1067–1072


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 75 - 82
1 Jan 2019
Kim J Lee SY Jung JH Kim SW Oh J Park MS Chang H Kim T

Aims. The aim of this study was to evaluate the outcome of spinal instrumentation in haemodialyzed patients with native pyogenic spondylodiscitis. Spinal instrumentation in these patients can be dangerous due to rates of complications and mortality, and biofilm formation on the instrumentation. Patients and Methods. A total of 134 haemodialyzed patients aged more than 50 years who underwent surgical treatment for pyogenic spondylodiscitis were included in the study. Their mean age was 66.4 years (50 to 83); 66 were male (49.3%) and 68 were female (50.7%). They were divided into two groups according to whether spinal instrumentation was used or not. Propensity score matching was used to attenuate the potential selection bias. The outcome of treatment was compared between these two groups. Results. A total of 89 patients (66.4%) underwent non-instrumented surgery and 45 (33.5%) underwent instrumented surgery. There were no significant differences in the rates of postoperative complications, except for an increased rate of wound problems in the instrumented group, which was found in the unmatched cohorts (p = 0.034). There were no significant differences in the rate of recurrent infections (p = 0.328 for the unmatched cohort; p = 0.269 for the matched cohort) and mortality rate, including in-hospital (p = 0.713 for the unmatched cohort; p = 0.738 for the matched cohort) and one-year rates (p = 0.363 for the unmatched cohort; p = 0.787 for the matched cohort), between the groups. However, the interval between the initial diagnosis and the first recurrence was significantly longer in the instrumented group (p = 0.008 for the unmatched cohort; p = 0.032 for the matched cohort). Conclusion. Instrumented surgery for haemodialyzed patients with pyogenic spondylodiscitis showed similar outcomes, including recurrence and mortality, to non-instrumented surgery, despite the instrumented group having more severe neurological deficit, a larger number of involved levels, and increased kyphotic angle


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims. Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation. Materials and Methods. A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force. Results. Augmentation showed no significant increase in the mean cycles to failure and fatigue force (SHORT p = 0.067; EXTENDED p = 0.239). Extending the instrumentation resulted in a significantly increased number of cycles to failure and a significantly higher fatigue force compared with the SHORT instrumentation (EXTENDED non-augmented + 76%, p < 0.001; EXTENDED augmented + 87%, p < 0.001). Conclusion. The stabilising effect of cement augmentation of pedicle screws might not be as beneficial as expected from biomechanical pull-out tests. Lengthening the dorsal instrumentation results in a much higher increase of stability during fatigue testing in the osteoporotic spine compared with cement augmentation. Cite this article: Bone Joint J 2016;98-B:1099–1105


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 565 - 572
1 May 2019
Teeter MG Marsh JD Howard JL Yuan X Vasarhelyi EM McCalden RW Naudie DDR

Aims. The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs. . Patients and Methods. The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (. sd. 8.4) in the PSI group and 69.4 years (. sd. 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group. Results. There were no differences (p > 0.05) in any measurement of migration at two years for either the tibial or femoral components. Movement between one and two years was < 0.2 mm, indicating stable fixation. There were no differences in coronal or sagittal alignment between the two groups. The PSI group took a mean 6.1 minutes longer (p = 0.04) and used a mean 3.4 less trays (p < 0.0001). Total waste generated was similar (10 kg) between the two groups. The PSI group cost a mean CAD$1787 more per case (p < 0.01). Conclusion. RSA criteria suggest that both groups will have revision rates of approximately 3% at five years. The advantages of PSI were minimal or absent for surgical resources used and waste eliminated, and for meeting target alignment, yet had significantly greater costs. Therefore, we conclude that PSI may not offer any advantage over CSI for routine primary TKA cases. Cite this article: Bone Joint J 2019;101-B:565–572


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 56 - 63
1 Jan 2015
Abane L Anract P Boisgard S Descamps S Courpied JP Hamadouche M

In this study we randomised 140 patients who were due to undergo primary total knee arthroplasty (TKA) to have the procedure performed using either patient-specific cutting guides (PSCG) or conventional instrumentation (CI). . The primary outcome measure was the mechanical axis, as measured at three months on a standing long-leg radiograph by the hip–knee–ankle (HKA) angle. This was undertaken by an independent observer who was blinded to the instrumentation. Secondary outcome measures were component positioning, operating time, Knee Society and Oxford knee scores, blood loss and length of hospital stay. A total of 126 patients (67 in the CI group and 59 in the PSCG group) had complete clinical and radiological data. There were 88 females and 52 males with a mean age of 69.3 years (47 to 84) and a mean BMI of 28.6 kg/m. 2. (20.2 to 40.8). The mean HKA angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4 to 183.4) in the PSCG group (p = 0.34). Outliers were identified in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%) in the PSCG group (p = 0.99). There was no significant difference in the clinical results (p = 0.95 and 0.59, respectively). Operating time, blood loss and length of hospital stay were not significantly reduced (p = 0.09, 0.58 and 0.50, respectively) when using PSCG. . The use of PSCG in primary TKA did not reduce the proportion of outliers as measured by post-operative coronal alignment. . Cite this article: Bone Joint J 2015;97-B:56–63


Aims. Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement. Patients and Methods. A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (. sd. 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (. sd. 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group. Results. There was no difference over two years in longitudinal migration of the tibial component between the KA+PSI and MA+CAS groups (reaching median maximum total point motion migration at two years of 0.40 mm for the KA+PSI group and 0.37 mm for the MA+CAS group, p = 0.82; p = 0.68 adjusted for age, sex, and body mass index (BMI) for all follow-ups). Both groups had mean migrations below acceptable thresholds. There was no difference in inducible displacement (p = 0.34) or PROMS (p = 0.61 for the Oxford Knee Score) between groups. There was no correlation between alignment and tibial component migration or alignment and inducible displacement. These findings support non-neutral alignment as a viable option with this component, with no evidence that it compromises fixation. Conclusion. Kinematic alignment using patient-specific instrumentation in TKA was associated with acceptable tibial component migration, indicating stable fixation. These results are supportive of future investigations of kinematic alignment. Cite this article: Bone Joint J 2019;101-B:929–940


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 210 - 214
1 Feb 2007
Lee JS Moon KP Kim SJ Suh KT

There are few reports of the treatment of lumbar tuberculous spondylitis using the posterior approach. Between January 1999 and February 2004, 16 patients underwent posterior lumbar interbody fusion with autogenous iliac-bone grafting and pedicle screw instrumentation. Their mean age at surgery was 51 years (28 to 66). The mean follow-up period was 33 months (24 to 48). The clinical outcome was assessed using the Frankel neurological classification and the Kirkaldy-Willis criteria. On the Frankel classification, one patient improved by two grades (C to E), seven by one grade, and eight showed no change. The Kirkaldy-Willis functional outcome was classified as excellent in eight patients, good in five, fair in two and poor in one. Bony union was achieved within one year in 15 patients. The mean pre-operative lordotic angle was 27.8° (9° to 45°) which improved by the final follow-up to 35.8° (28° to 48°). Post-operative complications occurred in four patients, transient root injury in two, a superficial wound infection in one and a deep wound infection in one, in whom the implant was removed. Our results show that a posterior lumbar interbody fusion with autogenous iliac-bone grafting and pedicle screw instrumentation for tuberculous spondylitis through the posterior approach can give satisfactory results


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 536 - 541
1 Dec 1982
Hsu L Zucherman J Tang S Leong J

Twenty-eight patients with adolescent idiopathic scoliosis treated by anterior spinal fusion with Dwyer instrumentation were reviewed. The average length of follow-up was 6.9 years. This technique produced better correction of lateral curvature and rotation than Harrington instrumentation, particularly in the thoracolumbar and lumbar region. The length of spine requiring fusion was also shorter. There is, however, a tendency for Dwyer instrumentation to lead to kyphosis. Morbidity was significant and included one case of paraplegia, four cases of deep infection and one case of instrument failure. All of these complications, except one case of deep infection, occurred in patients with curves with an apex above the seventh thoracic vertebra


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1061 - 1065
1 Aug 2010
Cho W Cho SK Wu C

There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Thirdly, fixation can be augmented in cases of severe osteoporosis or revision. A trajectory parallel or caudal to the superior endplate can minimise breakage of the screw from repeated axial loading. Straight insertion of the pedicle screw in the mid-sagittal plane provides the strongest stability. Rotational stability can be improved by adding transverse connectors. The indications for their use include anterior column instability, and the correction of rotational deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 98 - 102
1 Jan 2010
Lattig F Fekete TF Jeszenszky D

Fracture of a pedicle is a rare complication of spinal instrumentation using pedicular screws, but it can lead to instability and pain and may necessitate extension of the fusion. Osteosynthesis of the fractured pedicle by cerclage-wire fixation and augmentation of the screw fixation by vertebroplasty or temporary elongation of the fixation, allows stabilisation without sacrifice of the adjacent healthy segment. We describe three patients who developed a fracture of the pedicle in the most caudal instrumented vertebra early after lumbar spinal fusion. During revision surgery the pedicles were reduced and secured by a soft cerclage wire bilaterally. Fusion was obtained at the site of the primary instrumentation and healing of the pedicles was achieved. Cerclage wiring of the fractured pedicle seems to be safe and avoids permanent extension of the fusion without the sacrifice of an otherwise healthy segment


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1477 - 1481
1 Nov 2008
Jain AK Dhammi IK Prashad B Sinha S Mishra P

Injury to the spinal cord and kyphosis are the two most feared complications of tuberculosis of the spine. Since tuberculosis affects principally the vertebral bodies, anterior decompression is usually recommended. Concomitant posterior instrumentation is indicated to neutralise gross instability from panvertebral disease, to protect the anterior bone graft, to prevent graft-related complications after anterior decompression in long-segment disease and to correct a kyphosis. Two-stage surgery is usually performed in these cases. We present 38 consecutive patients with tuberculosis of the spine for whom anterior decompression, posterior instrumentation, with or without correction of the kyphus, and anterior and posterior fusion was performed in a single stage through an anterolateral extrapleural approach. Their mean age was 20.4 years (2.0 to 57.0). The indications for surgery were panvertebral disease, neurological deficit and severe kyphosis. The patients were operated on in the left lateral position using a ‘T’-shaped incision sited at the apex of kyphosis or lesion. Three ribs were removed in 34 patients and two in four and anterior decompression of the spinal cord was carried out. The posterior vertebral column was shortened to correct the kyphus, if necessary, and was stabilised by a Hartshill rectangle and sublaminar wires. Anterior and posterior bone grafting was performed. The mean number of vertebral bodies affected was 3.24 (2.0 to 9.0). The mean pre-operative kyphosis in patients operated on for correction of the kyphus was 49.08° (30° to 72°) and there was a mean correction of 25° (6° to 42°). All except one patient with a neural deficit recovered complete motor and sensory function. The mean intra-operative blood loss was 1175 ml (800 to 2600), and the mean duration of surgery 3.5 hours (2.7 to 5.0). Wound healing was uneventful in 33 of 38 patients. The mean follow-up was 33 months (11 to 74). None of the patients required intensive care. The extrapleural anterolateral approach provides simultaneous exposure of the anterior and posterior aspects of the spine, thereby allowing decompression of the spinal cord, posterior stabilisation and anterior and posterior bone grafting. This approach has much less morbidity than the two-stage approaches which have been previously described


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1052 - 1061
1 Aug 2014
Thienpont E Schwab PE Fennema P

We conducted a meta-analysis, including randomised controlled trials (RCTs) and cohort studies, to examine the effect of patient-specific instruments (PSI) on radiological outcomes after total knee replacement (TKR) including: mechanical axis alignment and malalignment of the femoral and tibial components in the coronal, sagittal and axial planes, at a threshold of > 3º from neutral. Relative risks (RR) for malalignment were determined for all studies and for RCTs and cohort studies separately. Of 325 studies initially identified, 16 met the eligibility criteria, including eight RCTs and eight cohort studies. There was no significant difference in the likelihood of mechanical axis malalignment with PSI versus conventional TKR across all studies (RR = 0.84, p = 0.304), in the RCTs (RR = 1.14, p = 0.445) or in the cohort studies (RR = 0.70, p = 0.289). The results for the alignment of the tibial component were significantly worse using PSI TKR than conventional TKR in the coronal and sagittal planes (RR = 1.75, p = 0.028; and RR = 1.34, p = 0.019, respectively, on pooled analysis). PSI TKR showed a significant advantage over conventional TKR for alignment of the femoral component in the coronal plane (RR = 0.65, p = 0.028 on pooled analysis), but not in the sagittal plane (RR = 1.12, p = 0.437). Axial alignment of the tibial (p = 0.460) and femoral components (p = 0.127) was not significantly different. We conclude that PSI does not improve the accuracy of alignment of the components in TKR compared with conventional instrumentation. Cite this article: Bone Joint J 2014; 96-B:1052–61


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 670 - 674
1 Jul 1990
Cundy P Paterson D Hillier T Sutherland A Stephen J Foster B

We have studied 34 consecutive patients receiving Cotrel- Dubousset instrumentation for a single and flexible thoracic scoliotic curve, evaluating the rib hump deformity from a single CT scan through the apical vertebra of the curve. Using two measures of rotation we found a mean improvement of 25% in the rotation of the vertebra after operation. Any, usually minor, deterioration occurred in the first six months postoperatively, and there was no significant further deterioration in 19 patients assessed over two years after surgery. Cotrel-Dubousset instrumentation can produce a significant correction of vertebral rotation and of the associated rib hump deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1670 - 1677
1 Dec 2012
Tsirikos AI Subramanian AS

We reviewed 212 consecutive patients with adolescent idiopathic scoliosis who underwent posterior spinal arthrodesis using all pedicle screw instrumentation in terms of clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51 patients), the correction was performed over two rods using bilateral segmental pedicle screws. In Group 2 (161 patients), the correction was performed over one rod using unilateral segmental pedicle screws with the second. rod providing stability of the construct through two-level screw fixation at proximal and distal ends. The mean age at surgery was 14.8 years in both groups. Comparison between groups showed no significant differences with regard to age and Risser grade at surgery, pre- and post-operative scoliosis angle, coronal Cobb correction, length of hospital stay and SRS scores. Correction of upper thoracic curves was significantly better in Group 1 (p = 0.02). Increased surgical time and intra-operative blood loss was recorded in Group 1 (p < 0.001 and p = 0.04, respectively). The implant cost was reduced by mean 35% in Group 2 due to the lesser number of pedicle screws. Unilateral and bilateral pedicle screw techniques have both achieved excellent deformity correction in adolescent patients with idiopathic scoliosis, which was maintained at two-year follow-up. This has been associated with high patient satisfaction and low complication rates


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1342 - 1347
1 Nov 2024
Onafowokan OO Jankowski PP Das A Lafage R Smith JS Shaffrey CI Lafage V Passias PG

Aims

The aim of this study was to investigate the impact of the level of upper instrumented vertebra (UIV) in frail patients undergoing surgery for adult spine deformity (ASD).

Methods

Patients with adult spinal deformity who had undergone T9-to-pelvis fusion were stratified using the ASD-Modified Frailty Index into not frail, frail, and severely frail categories. ASD was defined as at least one of: scoliosis ≥ 20°, sagittal vertical axis (SVA) ≥ 5 cm, or pelvic tilt ≥ 25°. Means comparisons tests were used to assess differences between both groups. Logistic regression analyses were used to analyze associations between frailty categories, UIV, and outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 20 - 25
1 Jan 1987
McMaster M

Twenty-three patients with severe paralytic thoracolumbar scoliosis due to a myelomeningocele were treated by a two-stage procedure. Before operation the mean scoliosis was 98 degrees: after the first-stage procedure, an anterior spinal fusion and correction with Dwyer instrumentation, this was reduced to a mean of 45 degrees. Approximately two weeks later a posterior spinal fusion with Harrington instrumentation was performed, further reducing the scoliosis to a mean of 29 degrees. The pelvic obliquity also was reduced from a mean of 32 degrees to 6 degrees. Although such management carries risks (one patient died of cardiorespiratory failure after the first stage and one patient was made worse), 21 of the 23 patients had improved posture and function


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 185 - 188
1 Mar 1986
McQueen M Court-Brown C Scott J

A method of stabilising spondylolisthesis using Dwyer instrumentation is described and the results in seven patients are presented. The operation is straightforward, has few complications and also succeeds in reducing the angle of slip


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 526 - 529
1 Dec 1982
Gertzbein S Macmichael D Tile M

The results of the use of Harrington rods in the treatment of spinal fractures were reviewed. It was found that with burst fractures where the anterior pillar was deficient there was a significant incidence of loss of reduction. Anterior bone supplementation is recommended in these fractures when major loss of height or angulation occurs. Several technical faults were detected which, in most cases, also led to a loss of reduction. Almost all patients with an anatomical reduction were free of pain. There was no correlation between the loss of reduction and the lapse of time before operation, the levels of instrumentation, the length of the fusion, the severity of the initial deformity, the degree of initial correction or the presence or absence of a neurological deficit


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1201 - 1205
1 Sep 2007
Sundararaj GD Babu N Amritanand R Venkatesh K Nithyananth M Cherian VM Lee VN

Anterior debridement, grafting of the defect and posterior instrumentation as a single-stage procedure is a controversial method of managing pyogenic vertebral osteomyelitis. Between 1994 and 2005, 37 patients underwent this procedure at our hospital, of which two died and three had inadequate follow-up. The remaining 32 were reviewed for a mean of 36 months (12 to 66). Their mean age was 48 years (17 to 68). A significant pre-operative neurological deficit was present in 13 patients (41%). The mean duration of surgery was 285 minutes (240 to 360) and the mean blood loss was 900 ml (300 to 1600). Pyogenic organisms were isolated in 21 patients (66%). All patients began to mobilise on the second post-operative day. The mean hospital stay was 13.6 days (10 to 20). Appropriate antibiotics were administered for 10 to 12 weeks. Early wound infection occurred in four patients (12.5%), and late infection in two (6.3%). At final follow-up, the infection had resolved in all patients, neurological recovery was seen in ten of 13 (76.9%) and interbody fusion had occurred in 30 (94%). The clinical outcome was excellent or good in 30 patients according to Macnab’s criteria. This surgical protocol can be used to good effect in patients with pyogenic vertebral osteomyelitis when combined with appropriate antibiotic therapy


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 58 - 63
1 Feb 1976
Piggott H

One hundred and three patients with scoliosis treated by posterior fusion and Harrington instrumentation are reviewed. The fusion technique described does not require added bone. Walking in a localiser plaster is encouraged as soon as the wound is healed, usually two weeks after operation. The results compare satisfactorily with others published. It is concluded that added bone is not necessary unless neural arch defects are present, and that early walking is advantageous and without risk to the correction


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 570 - 577
1 Aug 1968
Berkin CR

1. Twelve patients with suspected pseudarthroses in previous spine grafts were subjected to operation. 2. Correction of the curves was produced by Harrington's instrumentation at the sites of pseudarthroses, osteotomies and fractures. 3. A significant increase in stature was produced in all the patients. 4. Harrington's hooks were safely inserted into cavities cut in intact portions of previous grafts. 5. Most patients were able to leave hospital in less than four weeks. 6. Deliberate bending of the Harrington rods has not led to subsequent fracture of the rod. 7. A sliding scoliosis fusion frame is described. It reduces friction during correction and it reduces haemorrhage during surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 22 - 28
1 Jan 2001
Bentley G Haddad F Bull TM Seingry D

We have treated 101 patients with scoliosis secondary to muscular dystrophy over a 13-year period; 64 had Duchenne’s muscular dystrophy, 33 spinal muscular atrophy and four congenital muscular dystrophy. The patients underwent a modified Luque (87) or Harrington-Luque instrumentation (14) combined with a limited Moe fusion in all except 27 cases. A mean of 13 levels was instrumented. The mean preoperative sitting Cobb angle was 84° (10 to 150) and the mean postoperative angle 40° (52% correction). Most patients (96%) were able to discard their braces and there was a high level of patient satisfaction (89.6%). Less correction was seen for severe curves, and there was a greater recurrence of postoperative pelvic tilt in those patients not instrumented to the sacrum. Although the incidence of minor or temporary complications was high, these occurred chiefly in the early high-risk patients with very severe curves and considerable pre-existing immobility


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1342 - 1346
1 Oct 2016
Spencer-Gardner L Pierrepont J Topham M Baré J McMahon S Shimmin AJ

Aims

Accurate placement of the acetabular component during total hip arthroplasty (THA) is an important factor in the success of the procedure. However, the reported accuracy varies greatly and is dependent upon whether free hand or navigated techniques are used. The aim of this study was to assess the accuracy of an instrument system that incorporates 3D printed, patient-specific guides designed to optimise the placement of the acetabular component.

Patients and Methods

A total of 100 consecutive patients were prospectively enrolled and the accuracy of placement of the acetabular component was measured using post-operative CT scans.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 535 - 540
1 Apr 2014
Nagahama K Sudo H Abumi K Ito M Takahata M Hiratsuka S Kuroki K Iwasaki N

We investigated the incidence of anomalies in the vertebral arteries and Circle of Willis with three-dimensional CT angiography in 55 consecutive patients who had undergone an instrumented posterior fusion of the cervical spine.

We recorded any peri-operative and post-operative complications. The frequency of congenital anomalies was 30.9%, abnormal vertebral artery blood flow was 58.2% and vertebral artery dominance 40%.

The posterior communicating artery was occluded on one side in 41.8% of patients and bilaterally in 38.2%. Variations in the vertebral arteries and Circle of Willis were not significantly related to the presence or absence of posterior communicating arteries. Importantly, 18.2% of patients showed characteristic variations in the Circle of Willis with unilateral vertebral artery stenosis or a dominant vertebral artery, indicating that injury may cause lethal complications. One patient had post-operative cerebellar symptoms due to intra-operative injury of the vertebral artery, and one underwent a different surgical procedure because of insufficient collateral circulation.

Pre-operative assessment of the vertebral arteries and Circle of Willis is essential if a posterior spinal fusion with instrumentation is to be carried out safely.

Cite this article: Bone Joint J 2014;96-B:535–40.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 702 - 702
1 May 2009
SUNDARARAJ GD


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 452 - 456
1 May 1997
Hasegawa K Homma T Uchiyama S Takahashi HE

We have performed simple bone grafting in four elderly patients with pain due to unstable pseudarthroses in the osteoporotic spine after compression fracture.

At operation, we observed abnormal movement of the affected vertebral body which was covered with a hypertrophic membrane; this seemed to inhibit the blood supply to the lesion. The thick membrane and avascular granulation in the false joint were excised and bone grafting carried out. Symptoms were dramatically improved immediately after operation and bony union was confirmed in the three surviving patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 226 - 227
1 Apr 1982
Ransford A Edgar M


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1176 - 1181
1 Oct 2024
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Nietosvaara Y Helenius I

Aims. Closed suction subfascial drainage is widely used after instrumented posterior spinal fusion in patients with a spinal deformity. The aim of this study was to determine the effect of this wound drainage on the outcomes in patients with adolescent idiopathic scoliosis (AIS). This was a further analysis of a randomized, multicentre clinical trial reporting on patients after posterior spinal fusion using segmental pedicle screw instrumentation. In this study the incidence of deep surgical site infection (SSI) and chronic postoperative pain at two years’ follow-up are reported. Methods. We conducted a randomized, multicentre clinical trial on adolescents undergoing posterior spinal fusion for AIS using segmental pedicle screw instrumentation. A total of 90 consecutive patients were randomized into a ‘drain’ or ‘no drain’ group at the time of wound closure, using the sealed envelope technique (1:1). The primary outcomes in the initial study were the change in the level of haemoglobin in the blood postoperatively and total blood loss. A secondary outcome was the opioid consumption immediately after surgery. The aim of this further study was to report the rate of deep SSI and persistent postoperative pain, at two years' follow-up. Results. As previously reported, the mean 48-hour opioid consumption was significantly higher in the no drain group (2.0 mg/kg (SD 0.8) vs 1.4 mg/kg (SD 0.7); p = 0.005). There were no delayed deep SSIs. At two years’ follow-up, the mean Scoliosis Research Society 24-item questionnaire (SRS-24) total score did not differ between the groups (4.11 (SD 0.47) vs 4.16 (SD 0.33); p = 0.910). The mean SRS-24 pain score was 4.28 (SD 0.48) in the no drain group compared with 4.33 (SD 0.66) in the drain group (p = 0.245). Seven patients (19%) in the no drain group and six in the drain group (14%) reported moderate to severe pain (numerical rating scale ≥ 4) at two years’ follow-up (p = 0.484). The general self-image domain score was significantly higher in the no drain group compared with the drain group (4.02 (SD 0.74) vs 4.59 (SD 0.54); p < 0.001). Conclusion. The main finding in this study was that more severe pain immediately after surgery did not result in a higher incidence of chronic pain in the no drain group compared with the drain group. Back pain and health-related quality of life at two years’ follow-up did not differ between the groups. The patient-reported self-image domain was significantly better in the no drain group compared with the drain group. Cite this article: Bone Joint J 2024;106-B(10):1176–1181


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 148 - 156
1 Jan 2021
Tsirikos AI Carter TH

Aims. To report the surgical outcome of patients with severe Scheuermann’s kyphosis treated using a consistent technique and perioperative management. Methods. We reviewed 88 consecutive patients with a severe Scheuermann's kyphosis who had undergone posterior spinal fusion with closing wedge osteotomies and hybrid instrumentation. There were 55 males and 33 females with a mean age of 15.9 years (12.0 to 24.7) at the time of surgery. We recorded their demographics, spinopelvic parameters, surgical correction, and perioperative data, and assessed the impact of surgical complications on outcome using the Scoliosis Research Society (SRS)-22 questionnaire. Results. The mean follow-up was 8.4 years (2 to 14.9). There were 85 patients (96.6%) with a thoracic deformity. Posterior spinal fusion with closing-wedge osteotomies and hybrid instrumentation was used in 86 patients; two patients underwent combined anterior and posterior spinal fusion. The mean kyphosis was corrected from 94.5° to 47.5° (p < 0.001). Coronal and sagittal balance returned to normal. The rate of complications was 12.5%: there were no neurological deficits, implant failure, or revision surgery. SRS-22 scores improved from a mean 3.6 (1.3 to 4.1) to 4.6 (4.2 to 5.0) at two years (p < 0.001) with a high rate of patient satisfaction. Non-smokers and patients with lower preoperative SRS-22 scores showed greater improvement in their quality of life. Sagittal pelvic balance did not change after correction of the kyphosis and correlated with lumbar lordosis but not with thoracic or thoracolumbar kyphosis. Conclusion. Posterior spinal fusion using hybrid instrumentation, closing-wedge osteotomies, and iliac bone grafting achieves satisfactory correction of a severe kyphosis resulting in improvements in physical and mental health and a high degree of patient-reported satisfaction. Cite this article: Bone Joint J 2021;103-B(1):148–156


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims. The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique. Methods. This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively. Results. A total of 517 patients were included in the study. Their mean age was 65.0 years (SD 10.3) and their mean BMI was 29.2 kg/m. 2. (SD 5.5). A mean of 1.2 levels (SD 0.6) were fused with LLIF, and a mean of 1.6 (SD 0.9) posterior levels were fused. Femoral neuropraxia occurred in six patients (1.2%), of which four (0.8%) were LLIF-related and two (0.4%) had persistent symptoms one year postoperatively. Non-femoral neuropraxia occurred in nine patients (1.8%), one (0.2%) was LLIF-related and five (1.0%) were persistent at one year. All LLIF-related neuropraxias resolved by one year. A total of 32 patients (6.2%) had thigh pain, 31 (6.0%) were LLIF-related and three (0.6%) were persistent at one year. Weakness of hip flexion occurred in 14 patients (2.7%), of which eight (1.6%) were LLIF-related and three (0.6%) were persistent at one year. No patients had bowel injury, three (0.6%) had an intraoperative vascular injury (not LLIF-related), and five (1.0%) had ileus. Reoperations occurred in five patients (1.0%) within 30 days, 37 (7.2%) within 90 days, and 41 (7.9%) within one year postoperatively. Conclusion. LLIF involving the L4-L5 disc level has a low rate of persistent neurological, psoas-related, and abdominal complications in patients with the appropriate indications and using a standardized surgical technique. Cite this article: Bone Joint J 2024;106-B(1):53–61


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 892 - 897
1 Sep 2024
Mancino F Fontalis A Kayani B Magan A Plastow R Haddad FS

Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon’s philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation. Cite this article: Bone Joint J 2024;106-B(9):892–897


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims. This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes. Methods. Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence. Results. In all, 500 patients reached six-month follow-up, 420 reached one-year follow-up, and 188 reached two-year follow-up. The mean age was 67.8 years (23.9 to 88.5). A total of 38 patients (7.5%) presented with inflammatory arthritis. A total of 101 (20.0%) of implantations used patient-specific instrumentation; 167 patients (33.1%) underwent an additional procedure at the time of surgery. A total of seven patients died of unrelated causes, two withdrew, and one was lost to follow-up. The mean follow-up was 16.2 months (6 to 36). There was a significant improvement from baseline across all functional outcome scores at six months, one, and two years. There was no significant difference in outcomes with the use of patient-specific instrumentation, type of arthritis, or COFAS type. Five (1.0%) implants were revised. The overall complication rate was 8.8%. The non-revision reoperation rate was 1.4%. The 30-day readmission rate was 1.2% and the one-year mortality 0.74%. Conclusion. The early experience and complications reported in this study support the current use of the INFINITY TAA as a safe and effective implant in the treatment of end-stage ankle arthritis. Cite this article: Bone Joint J 2021;103-B(7):1270–1276


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 261 - 267
1 Feb 2020
Tøndevold N Lastikka M Andersen T Gehrchen M Helenius I

Aims. It is uncertain whether instrumented spinal fixation in nonambulatory children with neuromuscular scoliosis should finish at L5 or be extended to the pelvis. Pelvic fixation has been shown to be associated with up to 30% complication rates, but is regarded by some as the standard for correction of deformity in these conditions. The incidence of failure when comparing the most caudal level of instrumentation, either L5 or the pelvis, using all-pedicle screw instrumentation has not previously been reported. In this retrospective study, we compared nonambulatory patients undergoing surgery at two centres: one that routinely instrumented to L5 and the other to the pelvis. Methods. In all, 91 nonambulatory patients with neuromuscular scoliosis were included. All underwent surgery using bilateral, segmental, pedicle screw instrumentation. A total of 40 patients underwent fusion to L5 and 51 had their fixation extended to the pelvis. The two groups were assessed for differences in terms of clinical and radiological findings, as well as complications. Results. The main curve (MC) was a mean of 90° (40° to 141°) preoperatively and 46° (15° to 82°) at two-year follow-up in the L5 group, and 82° (33° to 116°) and 19° (1° to 60°) in the pelvic group (p < 0.001 at follow-up). Correction of MC and pelvic obliquity (POB) were statistically greater in the pelvic group (p < 0.001). There was no statistically significant difference in the operating time, blood loss, or complications. Loss of MC correction (> 10°) was more common in patients fixated to the pelvis (23% vs 3%; p = 0.032), while loss of pelvic obliquity correction was more frequent in the L5 group (25% vs 0%; p = 0.007). Risk factors for loss of correction (either POB or MC) included preoperative coronal imbalance (> 50 mm, odds ratio (OR) 11.5, 95%confidence interval (CI) 2.0 to 65; p = 0.006) and postoperative sagittal imbalance (> 25 mm, OR 11.0, 95% CI1.9 to 65; p = 0.008). Conclusion. We found that patients undergoing pelvic fixation had a greater correction of MC and POB. The rate of complications was not different. Preoperative coronal and postoperative sagittal imbalance were associated with increased risks of loss of correction, regardless of extent of fixation. Therefore, we recommend pelvic fixation in all nonambulatory children with neuromuscular scoliosis where coronal or sagittal imbalance are present preoperatively. Cite this article: Bone Joint J 2020;102-B(2):261–267


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 376 - 382
1 Mar 2020
Pesenti S Lafage R Henry B Kim HJ Bolzinger M Elysée J Cunningham M Choufani E Lafage V Blanco J Jouve J Widmann R

Aims. To compare the rates of sagittal and coronal correction for all-pedicle screw instrumentation and hybrid instrumentation using sublaminar bands in the treatment of thoracic adolescent idiopathic scoliosis (AIS). Methods. We retrospectively reviewed the medical records of 124 patients who had undergone surgery in two centres for the correction of Lenke 1 or 2 AIS. Radiological evaluation was carried out preoperatively, in the early postoperative phase, and at two-year follow-up. Parameters measured included coronal Cobb angles and thoracic kyphosis. Postoperative alignment was compared after matching the cohorts by preoperative coronal Cobb angle, thoracic kyphosis, lumbar lordosis, and pelvic incidence. Results. A total of 179 patients were available for analysis. After matching, 124 patients remained (62 in each cohort). Restoration of thoracic kyphosis was significantly better in the sublaminar band group than in the pedicle screw group (from 23.7° to 27.5° to 34.0° versus 23.9° to 18.7° to 21.5°; all p < 0.001). When the preoperative thoracic kyphosis was less than 20°, sublaminar bands achieved a normal postoperative thoracic kyphosis, whereas pedicle screws did not. In the coronal plane, pedicle screws resulted in a significantly better correction than sublaminar bands at final follow-up (73.0% versus 59.7%; p < 0.001). Conclusion. This is the first study to compare sublaminar bands and pedicle screws for the correction of a thoracic AIS. We have shown that pedicle screws give a good coronal correction which is maintained at two-year follow-up. Conversely, sublaminar bands restore the thoracic kyphosis better while pedicle screws are associated with a flattening of the thoracic spine. In patients with preoperative hypokyphosis, sublaminar bands should be used to restore a proper sagittal profile. Cite this article: Bone Joint J 2020;102-B(3):376–382


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 115 - 120
1 Jul 2019
Hooper J Schwarzkopf R Fernandez E Buckland A Werner J Einhorn T Walker PS

Aims. This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Materials and Methods. Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced. Results. Before and after steam sterilization, dimensional analysis showed that acrylonitrile butadiene styrene could not withstand the temperatures without dimensional changes. Oscillating saw tests with slotted cutting blocks produced debris, fractures, or further dimensional changes in the shape of Nylon-12 and polymethylmethacrylate (MED610), but polyetherimide ULTEM 1010 was least affected. Conclusion. The study showed that 3D-printed instrumentation was technically feasible and had some advantages. However, other factors, such as whether all procedural steps can be accomplished with a set of 3D-printed instruments, the logistics of delivery, and the economic aspects, require further study. Cite this article: Bone Joint J 2019;101-B(7 Supple C):115–120


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1563 - 1569
1 Dec 2019
Helenius IJ Saarinen AJ White KK McClung A Yazici M Garg S Thompson GH Johnston CE Pahys JM Vitale MG Akbarnia BA Sponseller PD

Aims. The aim of this study was to compare the surgical and quality-of-life outcomes of children with skeletal dysplasia to those in children with idiopathic early-onset scoliosis (EOS) undergoing growth-friendly management. Patients and Methods. A retrospective review of two prospective multicentre EOS databases identified 33 children with skeletal dysplasia and EOS (major curve ≥ 30°) who were treated with growth-friendly instrumentation at younger than ten years of age, had a minimum two years of postoperative follow-up, and had undergone three or more lengthening procedures. From the same registries, 33 matched controls with idiopathic EOS were identified. A total of 20 children in both groups were treated with growing rods and 13 children were treated with vertical expandable prosthetic titanium rib (VEPTR) instrumentation. Results. Mean preoperative major curves were 76° (34° to 115°) in the skeletal dysplasia group and 75° (51° to 113°) in the idiopathic group (p = 0.55), which were corrected at final follow-up to 49° (13° to 113°) and 46° (12° to 112°; p = 0.68), respectively. T1-S1 height increased by a mean of 36 mm (0 to 105) in the skeletal dysplasia group and 38 mm (7 to 104) in the idiopathic group at the index surgery (p = 0.40), and by 21 mm (1 to 68) and 46 mm (7 to 157), respectively, during the distraction period (p = 0.0085). The skeletal dysplasia group had significantly worse scores in the physical function, daily living, financial impact, and parent satisfaction preoperatively, as well as on financial impact and child satisfaction at final follow-up, than the idiopathic group (all p < 0.05). The domains of the 24-Item Early-Onset Scoliosis Questionnaire (EOSQ24) remained at the same level from preoperative to final follow-up in the skeletal dysplasia group (all p > 0.10). Conclusion. Children with skeletal dysplasia gained significantly less spinal growth during growth-friendly management of their EOS and their health-related quality of life was significantly lower both preoperatively and at final follow-up than in children with idiopathic EOS. Cite this article: Bone Joint J 2019;101-B:1563–1569


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 78 - 80
1 Jan 2016
Lee G

Patient specific instrumentation (PSI) uses advanced imaging of the knee (CT or MRI) to generate individualised cutting blocks aimed to make the procedure of total knee arthroplasty (TKA) more accurate and efficient. However, in this era of healthcare cost consciousness, the value of new technologies needs to be critically evaluated. There have been several comparative studies looking at PSI versus standard instrumentation. Most compare PSI with conventional instrumentation in terms of alignment in the coronal plane, operative time and surgical efficiency, cost effectiveness and short-term outcomes. Several systematic reviews and meta-analyses have also been published. PSI has not been shown to be superior compared with conventional instrumentation in its ability to restore traditional mechanical alignment in primary TKA. Most studies show comparative efficacy and no decrease in the number of outliers in either group. In terms of operative time and efficiency, PSI tended towards decreasing operative time, saving a mean of five minutes per patient (0 to 20). Furthermore, while some cost savings could be realised with less operative time and reduced instrumentation per patient, these savings were overcome by the cost of the CT/MRI and the cutting blocks. Finally, there was no evidence that PSI positively affected clinical outcomes at two days, two months, or two years. Consequently, current evidence does not support routine use of PSI in routine primary TKA. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):78–80


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1392 - 1399
2 Aug 2021
Kang TW Park SY Oh H Lee SH Park JH Suh SW

Aims. Open discectomy (OD) is the standard operation for lumbar disc herniation (LDH). Percutaneous endoscopic lumbar discectomy (PELD), however, has shown similar outcomes to OD and there is increasing interest in this procedure. However despite improved surgical techniques and instrumentation, reoperation and infection rates continue and are reported to be between 6% and 24% and 0.7% and 16%, respectively. The objective of this study was to compare the rate of reoperation and infection within six months of patients being treated for LDH either by OD or PELD. Methods. In this retrospective, nationwide cohort study, the Korean National Health Insurance database from 1 January 2007 to 31 December 2018 was reviewed. Data were extracted for patients who underwent OD or PELD for LDH without a history of having undergone either procedure during the preceding year. Individual patients were followed for six months through their encrypted unique resident registration number. The primary endpoints were rates of reoperation and infection during the follow-up period. Other risk factors for reoperation and infection were also evalulated. Results. Out of 549,531 patients, 522,640 had undergone OD (95.11%) and 26,891 patients had undergone PELD (4.89%). Reoperation rates within six months were 2.28% in the OD group, and 5.38% in the PELD group. Infection rates were 1.18% in OD group and 0.83% in PELD group. The risk of reoperation was lower for patients with OD than for patients with PELD (adjusted hazard ratio (HR) 0.38). The risk of infection was higher for patients with OD than for patients undergoing PELD (HR, 1.325). Conclusion. Compared with the OD group, the PELD group showed higher reoperation rates and lower infection rates. Cite this article: Bone Joint J 2021;103-B(8):1392–1399


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 53 - 58
1 Jul 2021
Lawrie CM Bechtold D Schwabe M Clohisy JC

Aims. The direct anterior approach (DAA) for total hip arthroplasty (THA) has potential advantages over other approaches and is most commonly performed with the patient in the supine position. We describe a technique for DAA THA with the patient in the lateral decubitus position and report the early clinical and radiological outcomes, the characteristics of the learning curve, and perioperative complications. Methods. All primary DAA THAs performed in the lateral position by a single surgeon over a four-year period from the surgeon’s first case using the technique were identified from a prospectively collected database. Modified Harris Hip Scores (mHHS) were collected to assess clinical outcome, and routine radiological analysis was performed. Retrospective review of the medical records identified perioperative complications, the characteristics of the learning curve, and revisions. Results. A total of 257 patients were included in the study. Their mean age was 60 years (SD 9.0). A total of 164 (64%) were female. The mean mHHS improved significantly from 52.1 (SD 16.2) preoperatively to 94.4 (SD 11) at a follow-up of one year (p < 0.001), with 212 of 225 patients (94%) achieving a minimal clinically important difference (MCID) (> 8 points). Radiological evaluation showed a mean leg length discrepancy of 2.6 mm (SD 5.9) and a mean difference in femoral offset of 0.2 mm (SD 4.9). A total of 234/243 acetabular components (96.3%) were positioned within Lewinnek’s safe zone. Analysis of operating time, blood loss, the position of the components, and complications did not identify a learning curve. A total of 14 patients (5.4%) had a major perioperative complication and three (1.2%) required revision THA. There were no major neurovascular complications and no dislocations. Conclusion. We have described and analyzed a surgical technique for undertaking DAA THA in the familiar lateral decubitus position using a routine operating table, positioning devices, and instrumentation, and shown that it can be performed safely and effectively under these circumstances. Cite this article: Bone Joint J 2021;103-B(7 Supple B):53–58


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1088 - 1095
1 Jun 2021
Banger M Doonan J Rowe P Jones B MacLean A Blyth MJB

Aims. Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs. Methods. The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups. Results. Overall, 104 (80%) patients of the original 130 who received surgery were available at five years (55 robotic, 49 manual). Both procedures reported successful results over all outcomes. At five years, there were no statistical differences between the groups in any of the patient reported or clinical outcomes. There was a lower reintervention rate in the robotic arm-assisted group with 0% requiring further surgery compared with six (9%) of the manual group requiring additional surgical intervention (p < 0.001). Conclusion. This study has shown excellent clinical outcomes in both groups with no statistical or clinical differences in the patient-reported outcome measures. The notable difference was the lower reintervention rate at five years for roboticarm-assisted UKA when compared with a manual approach. Cite this article: Bone Joint J 2021;103-B(6):1088–1095


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 834 - 839
1 Jun 2016
Wang S Ma H Lin C Chou P Liu C Yu W Chang M

Aim. Many aspects of the surgical treatment of patients with tuberculosis (TB) of the spine, including the use of instrumentation and the types of graft, remain controversial. Our aim was to report the outcome of a single-stage posterior procedure, with or without posterior decompression, in this group of patients. Patients and Methods. Between 2001 and 2010, 51 patients with a mean age of 62.5 years (39 to 86) underwent long posterior instrumentation and short posterior or posterolateral fusion for TB of the thoracic and lumbar spines, followed by anti-TB chemotherapy for 12 months. No anterior debridement of the necrotic tissue was undertaken. Posterior decompression with laminectomy was carried out for the 30 patients with a neurological deficit. Results. The mean kyphotic angle improved from 26.1° (- 1.8° to 62°) to 15.2° (-25° to 51°) immediately after the operation. At a mean follow-up of 68.8 months (30 to 144) the mean kyphotic angle was 16.9° (-22° to 54°), with a mean loss of correction of 1.6° (0° to 10°). There was a mean improvement in neurological status of 1.2 Frankel grades in those with a neurological deficit. Bony union was achieved in all patients, without recurrent infection. Conclusions. Long posterior instrumentation with short posterior or posterolateral fusion is effective in the treatment of TB spine. It controls infection, corrects the kyphosis, and maintains correction and neurological improvement over time. . Take home message: With effective anti-TB chemotherapy, a posterior only procedure without debridement of anterior lesion is effective in the treatment of TB spondylitis, and an anterior procedure can be reserved for those patients who have not improved after posterior surgery. Cite this article: Bone Joint J 2016;98-B:834–9


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 547 - 552
1 Mar 2021
Magampa RS Dunn R

Aims. Spinal deformity surgery carries the risk of neurological injury. Neurophysiological monitoring allows early identification of intraoperative cord injury which enables early intervention resulting in a better prognosis. Although multimodal monitoring is the ideal, resource constraints make surgeon-directed intraoperative transcranial motor evoked potential (TcMEP) monitoring a useful compromise. Our experience using surgeon-directed TcMEP is presented in terms of viability, safety, and efficacy. Methods. We carried out a retrospective review of a single surgeon’s prospectively maintained database of cases in which TcMEP monitoring had been used between 2010 and 2017. The upper limbs were used as the control. A true alert was recorded when there was a 50% or more loss of amplitude from the lower limbs with maintained upper limb signals. Patients with true alerts were identified and their case history analyzed. Results. Of the 299 cases reviewed, 279 (93.3%) had acceptable traces throughout and awoke with normal clinical neurological function. No patient with normal traces had a postoperative clinical neurological deficit. True alerts occurred in 20 cases (6.7%). The diagnoses of the alert group included nine cases of adolescent idiopathic scoliosis (AIS) (45%) and six of congenital scoliosis (30%). The incidence of deterioration based on diagnosis was 9/153 (6%) for AIS, 6/30 (20%) for congenital scoliosis, and 2/16 (12.5%) for spinal tuberculosis. Deterioration was much more common in congenital scoliosis than in AIS (p = 0.020). Overall, 65% of alerts occurred during rod instrumentation: 15% occurred during decompression of the internal apex in vertebral column resection surgery. Four alert cases (20%) awoke with clinically detectable neurological compromise. Conclusion. Surgeon-directed TcMEP monitoring has a 100% negative predictive value and allows early identification of physiological cord distress, thereby enabling immediate intervention. In resource constrained environments, surgeon-directed TcMEP is a viable and effective method of intraoperative spinal cord monitoring. Level of evidence: III. Cite this article: Bone Joint J 2021;103-B(3):547–552


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims. Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning. Methods. A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts. Results. A total of 59 surgeons completed the survey. For all surgeons, the use of the PSP significantly increased agreement with the experts in glenoid classification (x. 2. = 8.54; p = 0.014) and surgical planning (x. 2. = 37.91; p < 0.001). The additional information provided by the PSP also showed a significantly higher impact on surgical decision-making for surgeons who undertake fewer than ten shoulder arthroplasties annually (p = 0.017). Conclusions. The information provided by PSP has the greatest impact on the surgical decision-making of low volume surgeons (those who perform fewer than ten shoulder arthroplasties annually), and PSP brings all surgeons in to closer agreement with the recommendations of experts for glenoid classification and surgical planning. Cite this article: Bone Joint J 2020;102-B(3):365–370


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 5 - 10
1 Jan 2020
Cawley DT Rajamani V Cawley M Selvadurai S Gibson A Molloy S

Aims. Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery. Methods. A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed. Results. The greatest gains in productivity were in avoiding repeat intraoperative scans (a mean of 248 minutes for patients who had two scans, and a mean 180 minutes for those who had a single scan). Optimizing accuracy was the biggest factor influencing this, which was reliant on incremental changes to the operating setup and technique. Conclusion. The application of lean principles to the introduction of ION for AIS surgery helps assimilate this method into the environment of the operating theatre. Data and stakeholder analysis identified a reproducible technique for using ION for AIS surgery, reducing operating time, and radiation exposure. Cite this article: Bone Joint J. 2020;102-B(1):5–10


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 354 - 359
1 Mar 2013
Chareancholvanich K Narkbunnam R Pornrattanamaneewong C

Patient-specific cutting guides (PSCGs) are designed to improve the accuracy of alignment of total knee replacement (TKR). We compared the accuracy of limb alignment and component positioning after TKR performed using PSCGs or conventional instrumentation. A total of 80 patients were randomised to undergo TKR with either of the different forms of instrumentation, and radiological outcomes and peri-operative factors such as operating time were assessed. No significant difference was observed between the groups in terms of tibiofemoral angle or femoral component alignment. Although the tibial component in the PSCGs group was measurably closer to neutral alignment than in the conventional group, the size of the difference was very small (89.8° (. sd. 1.2) vs 90.5° (. sd. 1.6); p = 0.030). This new technology slightly shortened the bone-cutting time by a mean of 3.6 minutes (p < 0.001) and the operating time by a mean 5.1 minutes (p = 0.019), without tangible differences in post-operative blood loss (p = 0.528) or need for blood transfusion (p = 0.789). This study demonstrated that both PSCGs and conventional instrumentation restore limb alignment and place the components with the similar accuracy. The minimal advantages of PSCGs in terms of consistency of alignment or operative time are unlikely to be clinically relevant. Cite this article: Bone Joint J 2013;95-B:354–9


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 402 - 409
1 Mar 2016
Sudo H Kaneda K Shono Y Iwasaki N

Aims. A total of 30 patients with thoracolumbar/lumbar adolescent idiopathic scoliosis (AIS) treated between 1989 and 2000 with anterior correction and fusion surgery using dual-rod instrumentation were reviewed. . Patients and Methods. Radiographic parameters and clinical outcomes were compared among patients with lowest instrumented vertebra (LIV) at the lower end vertebra (LEV; EV group) (n = 13) and those treated by short fusion (S group), with LIV one level proximal to EV (n = 17 patients). . Results. The allocation of the surgical technique was determined by the flexibility of the TL/L curves and/or neutral vertebrae located one level above LEV as determined on preoperative radiographs. If these requirements were met a short fusion was performed. The mean follow-up period was 21.4 years (16 to 27). The mean correction rate at final follow-up was significantly lower in the S group (74 . sd. 11%) than in the EV group (88 . sd. 13%) (p = 0.004).Coronal and sagittal balance, thoracic kyphosis, lumbar lordosis, and clinical outcomes evaluated by the Scoliosis Research Society-22 questionnaire scores were equivalent between the two groups. . Conclusion. Short fusion strategy, which uses LIV one level proximal to LEV can be considered as an alternative to the conventional strategy, which includes LEV in the fusion, when highly flexible TL/L curves are confirmed and/or neutral vertebrae are located one level above LEV in patients with thoracolumbar/lumbar AIS curves. Take home message: Short fusion strategy can be considered as an alternative to the conventional strategy in patients with thoracolumbar/lumbar AIS curves undergoing anterior spinal fusion with dual-rod instrumentation. Cite this article: Bone Joint J 2016;98-B:402–9


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 405 - 411
1 Mar 2012
Keel MJB Ecker TM Cullmann JL Bergmann M Bonel HM Büchler L Siebenrock KA Bastian JD

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five ‘windows’ for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called ‘Pararectus’ approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (. sd. 2.6) vs 0.1 mm (. sd. 0.3), p < 0.001; and mean gap 11.5 mm (. sd. 6.5) vs 0.8 mm (. sd. 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims. A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation. Methods. This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded. Results. There were 194 patients in the control group, 103 in group 1, and 74 in group 2. There were no significant differences in baseline demographics between the groups. Patients in group 2 had significantly higher baseline mental health subscores than control and group 1 patients (53.2 vs 50.2 vs 50.2, p = 0.041). There were no significant differences in any PROMs at six weeks or 12 months postoperatively (p > 0.05). There was no difference in the rate of manipulation under anaesthesia (MUA), complication rates, postoperative ROM, or blood loss. There were fewer mechanical axis outliers in groups 1 and 2 (25.2%, 14.9% respectively) versus control (28.4%), but this was not statistically significant (p = 0.10). Conclusion. The sequential addition of navigation of the distal femoral cut and sensor-guided ligament balancing did not improve short-term PROMs, radiological outcomes, or complication rates compared with conventional techniques. The costs of these added technologies may not be justified. Cite this article: Bone Joint J 2020;102-B(6 Supple A):24–30


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 102 - 108
1 Feb 2023
MacDessi SJ Oussedik S Abdel MP Victor J Pagnano MW Haddad FS

Orthopaedic surgeons are currently faced with an overwhelming number of choices surrounding total knee arthroplasty (TKA), not only with the latest technologies and prostheses, but also fundamental decisions on alignment philosophies. From ‘mechanical’ to ‘adjusted mechanical’ to ‘restricted kinematic’ to ‘unrestricted kinematic’ — and how constitutional alignment relates to these — there is potential for ambiguity when thinking about and discussing such concepts. This annotation summarizes the various alignment strategies currently employed in TKA. It provides a clear framework and consistent language that will assist surgeons to compare confidently and contrast the concepts, while also discussing the latest opinions about alignment in TKA. Finally, it provides suggestions for applying consistent nomenclature to future research, especially as we explore the implications of 3D alignment patterns on patient outcomes.

Cite this article: Bone Joint J 2023;105-B(2):102–108.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 93 - 98
1 Jan 2024
Broida SE Tsoi KM Rose PS Ferguson PC Griffin AM Wunder JS Houdek MT

Aims

The sacroiliac joint (SIJ) is the only mechanical connection between the axial skeleton and lower limbs. Following iliosacral resection, there is debate on whether reconstruction of the joint is necessary. There is a paucity of data comparing the outcomes of patients undergoing reconstruction and those who are not formally reconstructed.

Methods

A total of 60 patients (25 females, 35 males; mean age 39 years (SD 18)) undergoing iliosacral resection were reviewed. Most resections were performed for primary malignant tumours (n = 54; 90%). The mean follow-up for surviving patients was nine years (2 to 19).


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 148 - 157
1 Feb 2023
Koster LA Rassir R Kaptein BL Sierevelt IN Schager M Nelissen RGHH Nolte PA

Aims

The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs.

Methods

A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 541 - 547
1 Apr 2014
Kose KC Inanmaz ME Isik C Basar H Caliskan I Bal E

The purpose of this study was to evaluate and compare the effect of short segment pedicle screw instrumentation and an intermediate screw (SSPI+IS) on the radiological outcome of type A thoracolumbar fractures, as judged by the load-sharing classification, percentage canal area reduction and remodelling. . We retrospectively evaluated 39 patients who had undergone hyperlordotic SSPI+IS for an AO-Magerl Type-A thoracolumbar fracture. Their mean age was 35.1 (16 to 60) and the mean follow-up was 22.9 months (12 to 36). There were 26 men and 13 women in the study group. In total, 18 patients had a load-sharing classification score of seven and 21 a score of six. All radiographs and CT scans were evaluated for sagittal index, anterior body height compression (%ABC), spinal canal area and encroachment. There were no significant differences between the low and high score groups with respect to age, duration of follow-up, pre-operative sagittal index or pre-operative anterior body height compression (p = 0.217, 0.104, 0.104, and 0.109 respectively). The mean pre-operative sagittal index was 19.6° (12° to 28°) which was corrected to -1.8° (-5° to 3°) post-operatively and 2.4° (0° to 8°) at final follow-up (p = 0.835 for sagittal deformity). No patient needed revision for loss of correction or failure of instrumentation. Hyperlordotic reduction and short segment pedicle screw instrumentation and an intermediate screw is a safe and effective method of treating burst fractures of the thoracolumbar spine. It gives excellent radiological results with a very low rate of failure regardless of whether the fractures have a high or low load-sharing classification score. Cite this article: Bone Joint J 2014;96-B:541–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1393 - 1398
1 Oct 2012
Mattila M Jalanko T Puisto V Pajulo O Helenius IJ

We compared the clinical, radiological and quality-of-life outcomes between hybrid and total pedicle screw instrumentation in patients undergoing surgery for neuromuscular scoliosis. A matched comparison using prospectively collected data was undertaken. A total of 66 patients underwent posterior or anteroposterior correction and fusion with hybrid (n = 33, mean age at surgery 15.8 years (9.10 to 19.6)) or total pedicle screw instrumentation (n = 33, mean age 14.7 years (7.0 to 20.7)) with a minimum follow-up of two years. The major curve pre-operatively was a mean of 87° (. sd. 29, 25° to 141°) and 81° (. sd. 18, 47° to 116°) in the hybrid and total pedicle screw groups, respectively (p = 0.29) and at a minimum of two years it was 33° (. sd. 20; 2° to 87°) and 20° (. sd. 12; 1° to 55°), respectively (p = 0.0016). The mean correction of the major curve was 59% (41% to 88%) in the hybrid and 75% (43% to 99%) in the total pedicle screw groups at two-year follow-up (p = 0.0011). The mean operating time was 7.45 hours (. sd. 2.18) and 6.04 hours (. sd. 1.71) in the hybrid and total pedicle screw groups, respectively (p = 0.001), and the mean intra-operative blood loss was 3760 ml (. sd.  2790) and 1785 ml (. sd. 1110), respectively (p = 0.001). Total pedicle screw instrumentation provided shorter operating times, less blood loss and better correction of the major curve compared with hybrid constructs in patients undergoing surgery for neuromuscular scoliosis


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 312 - 318
1 Apr 2024
Sheth NP Jones SA Sanghavi SA Manktelow A

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.

Cite this article: Bone Joint J 2024;106-B(4):312–318.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 59 - 66
1 Mar 2024
Karunaseelan KJ Nasser R Jeffers JRT Cobb JP

Aims

Surgical approaches that claim to be minimally invasive, such as the direct anterior approach (DAA), are reported to have a clinical advantage, but are technically challenging and may create more injury to the soft-tissues during joint exposure. Our aim was to quantify the effect of soft-tissue releases on the joint torque and femoral mobility during joint exposure for hip resurfacing performed via the DAA.

Methods

Nine fresh-frozen hip joints from five pelvis to mid-tibia cadaveric specimens were approached using the DAA. A custom fixture consisting of a six-axis force/torque sensor and motion sensor was attached to tibial diaphysis to measure manually applied torques and joint angles by the surgeon. Following dislocation, the torques generated to visualize the acetabulum and proximal femur were assessed after sequential release of the joint capsule and short external rotators.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1059 - 1066
1 Oct 2024
Konishi T Hamai S Tsushima H Kawahara S Akasaki Y Yamate S Ayukawa S Nakashima Y

Aims

The Coronal Plane Alignment of the Knee (CPAK) classification has been developed to predict individual variations in inherent knee alignment. The impact of preoperative and postoperative CPAK classification phenotype on the postoperative clinical outcomes of total knee arthroplasty (TKA) remains elusive. This study aimed to examine the effect of postoperative CPAK classification phenotypes (I to IX), and their pre- to postoperative changes on patient-reported outcome measures (PROMs).

Methods

A questionnaire was administered to 340 patients (422 knees) who underwent primary TKA for osteoarthritis (OA) between September 2013 and June 2019. A total of 231 patients (284 knees) responded. The ­Knee Society Score 2011 (KSS 2011), Knee injury and Osteoarthritis Outcome Score-12 (KOOS-12), and Forgotten Joint Score-12 (FJS-12) were used to assess clinical outcomes. Using preoperative and postoperative anteroposterior full-leg radiographs, the arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) were calculated and classified based on the CPAK classification. To investigate the impact on PROMs, multivariable regression analyses using stepwise selection were conducted, considering factors such as age at surgery, time since surgery, BMI, sex, implant use, postoperative aHKA classification, JLO classification, and changes in aHKA and JLO classifications from preoperative to postoperative.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 596 - 602
1 Jun 2024
Saarinen AJ Sponseller P Thompson GH White KK Emans J Cahill PJ Hwang S Helenius I

Aims

The aim of this study was to compare outcomes after growth-friendly treatment for early-onset scoliosis (EOS) between patients with skeletal dysplasias versus those with other syndromes.

Methods

We retrospectively identified 20 patients with skeletal dysplasias and 292 with other syndromes (control group) who had completed surgical growth-friendly EOS treatment between 1 January 2000 and 31 December 2018. We compared radiological parameters, complications, and health-related quality of life (HRQoL) at mean follow-up of 8.6 years (SD 3.3) in the dysplasia group and 6.6 years (SD 2.6) in the control group.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 543 - 550
1 May 2023
Abel F Avrumova F Goldman SN Abjornson C Lebl DR

Aims

The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system.

Methods

The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims

This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days.

Methods

We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 94 - 99
1 Jan 2014
Evans S Ramasamy A Marks DS Spilsbury J Miller P Tatman A Gardner AC

The management of spinal deformity in children with univentricular cardiac pathology poses significant challenges to the surgical and anaesthetic teams. To date, only posterior instrumented fusion techniques have been used in these children and these are associated with a high rate of complications. We reviewed our experience of both growing rod instrumentation and posterior instrumented fusion in children with a univentricular circulation. Six children underwent spinal corrective surgery, two with cavopulmonary shunts and four following completion of a Fontan procedure. Three underwent growing rod instrumentation, two had a posterior fusion and one had spinal growth arrest. There were no complications following surgery, and the children undergoing growing rod instrumentation were successfully lengthened. We noted a trend for greater blood loss and haemodynamic instability in those whose surgery was undertaken following completion of a Fontan procedure. At a median follow-up of 87.6 months (interquartile range (IQR) 62.9 to 96.5) the median correction of deformity was 24.2% (64.5° (IQR 46° to 80°) vs 50.5° (IQR 36° to 63°)). We believe that early surgical intervention with growing rod instrumentation systems allows staged correction of the spinal deformity and reduces the haemodynamic insult to these physiologically compromised children. Due to the haemodynamic changes that occur with the completed Fontan circulation, the initial scoliosis surgery should ideally be undertaken when in the cavopulmonary shunt stage. Cite this article: Bone Joint J 2014;96-B:94–9


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 400 - 411
15 Mar 2023
Hosman AJF Barbagallo G van Middendorp JJ

Aims

The aim of this study was to determine whether early surgical treatment results in better neurological recovery 12 months after injury than late surgical treatment in patients with acute traumatic spinal cord injury (tSCI).

Methods

Patients with tSCI requiring surgical spinal decompression presenting to 17 centres in Europe were recruited. Depending on the timing of decompression, patients were divided into early (≤ 12 hours after injury) and late (> 12 hours and < 14 days after injury) groups. The American Spinal Injury Association neurological (ASIA) examination was performed at baseline (after injury but before decompression) and at 12 months. The primary endpoint was the change in Lower Extremity Motor Score (LEMS) from baseline to 12 months.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1039 - 1046
1 Sep 2022
Özdemir E Kuijpers MFL Visser J Schreurs BW Rijnen WHC

Aims

The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique.

Methods

We updated the outcomes of our previous study, based on 208 consecutive revisions using IBG and the X-change femoral revision system in combination with a cemented polished stem, performed in our tertiary care institute between 1991 and 2007. Kaplan-Meier survival analyses were used to determine the survival rate of the revisions with endpoint revision for any reason and aseptic loosening. Secondary outcomes were radiological loosening and patient-reported outcome measures.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 590 - 592
1 Jun 2023
Manktelow ARJ Mitchell P Haddad FS

Cite this article: Bone Joint J 2023;105-B(6):590–592.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 557 - 560
1 Apr 2007
Davis ET Gallie P Macgroarty K Waddell JP Schemitsch E

A cadaver study using six pairs of lower limbs was conducted to investigate the accuracy of computer navigation and standard instrumentation for the placement of the Birmingham Hip Resurfacing femoral component. The aim was to place all the femoral components with a stem-shaft angle of 135°. The mean stem-shaft angle obtained in the standard instrumentation group was 127.7° (120° to 132°), compared with 133.3° (131° to 139°) in the computer navigation group (p = 0.03). The scatter obtained with computer-assisted navigation was approximately half that found using the conventional jig. Computer navigation was more accurate and more consistent in its placement of the femoral component than standard instrumentation. We suggest that image-free computer-assisted navigation may have an application in aligning the femoral component during hip resurfacing


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 215 - 219
1 Feb 2023
Buchan SJ Lindisfarne EA Stabler A Barry M Gent ED Bennet S Aarvold A

Aims

Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide.

Methods

All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1329 - 1333
1 Dec 2022
Renfree KJ

This annotation reviews current concepts on the three most common surgical approaches used for proximal interphalangeal joint arthroplasty: dorsal, volar, and lateral. Advantages and disadvantages of each are highlighted, and the outcomes are discussed.

Cite this article: Bone Joint J 2022;104-B(12):1329–1333.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 377 - 381
1 Mar 2008
Canavese F Gupta S Krajbich JI Emara KM

Our aim was to review the efficacy of the wound vacuum-assisted closure (VAC) system in the treatment of deep infection after extensive instrumentation and fusion for spinal deformity in children and adolescents. A total of 14 patients with early deep spinal infection were treated using this technique. Of these, 12 had neuromuscular or syndromic problems. Clinical and laboratory data were reviewed. The mean follow-up was 44 months (24 to 72). All wounds healed. Two patients required plastic surgery to speed up the process. In no patient was the hardware removed and there was no loss of correction or recurrent infection. We believe that the wound VAC system is a useful tool in the armamentarium of the spinal surgeon dealing with patients susceptible to wound infections, especially those with neuromuscular diseases. It allows for the retention of the instrumentation and the maintenance of spinal correction. It is reliable and easy to use


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 5 - 10
1 Jan 2023
Crowe CS Kakar S

Injury to the triangular fibrocartilage complex (TFCC) may result in ulnar wrist pain with or without instability. One component of the TFCC, the radioulnar ligaments, serve as the primary soft-tissue stabilizer of the distal radioulnar joint (DRUJ). Tears or avulsions of its proximal, foveal attachment are thought to be associated with instability of the DRUJ, most noticed during loaded pronosupination. In the absence of detectable instability, injury of the foveal insertion of the radioulnar ligaments may be overlooked. While advanced imaging techniques such as MRI and radiocarpal arthroscopy are well-suited for diagnosing central and distal TFCC tears, partial and complete foveal tears without instability may be missed without a high degree of suspicion. While technically challenging, DRUJ arthroscopy provides the most accurate method of detecting foveal abnormalities. In this annotation the spectrum of foveal injuries is discussed and a modified classification scheme is proposed.

Cite this article: Bone Joint J 2023;105-B(1):5–10.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 114 - 120
1 Feb 2024
Khatri C Metcalfe A Wall P Underwood M Haddad FS Davis ET

Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies.

Cite this article: Bone Joint J 2024;106-B(2):114–120.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 166 - 171
1 Feb 2023
Ragborg LC Dragsted C Ohrt-Nissen S Andersen T Gehrchen M Dahl B

Aims

Only a few studies have investigated the long-term health-related quality of life (HRQoL) in patients with an idiopathic scoliosis. The aim of this study was to investigate the overall HRQoL and employment status of patients with an idiopathic scoliosis 40 years after diagnosis, to compare it with that of the normal population, and to identify possible predictors for a better long-term HRQoL.

Methods

We reviewed the full medical records and radiological reports of patients referred to our hospital with a scoliosis of childhood between April 1972 and April 1982. Of 129 eligible patients with a juvenile or adolescent idiopathic scoliosis, 91 took part in the study (71%). They were evaluated with full-spine radiographs and HRQoL questionnaires and compared with normative data. We compared the HRQoL between observation (n = 27), bracing (n = 46), and surgical treatment (n = 18), and between thoracic and thoracolumbar/lumbar (TL/L) curves.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 593 - 601
1 Jun 2023
Scott CEH Yapp LZ Howard T Patton JT Moran M

Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty.

Cite this article: Bone Joint J 2023;105-B(6):593–601.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1044 - 1049
1 Oct 2024
Abelleyra Lastoria DA Ogbolu C Olatigbe O Beni R Iftikhar A Hing CB

Aims

To determine whether obesity and malnutrition have a synergistic effect on outcomes from skeletal trauma or elective orthopaedic surgery.

Methods

Electronic databases including MEDLINE, Global Health, Embase, Web of Science, ScienceDirect, and PEDRo were searched up to 14 April 2024, as well as conference proceedings and the reference lists of included studies. Studies were appraised using tools according to study design, including the Oxford Levels of Evidence, the Institute of Health Economics case series quality appraisal checklist, and the CLARITY checklist for cohort studies. Studies were eligible if they reported the effects of combined malnutrition and obesity on outcomes from skeletal trauma or elective orthopaedic surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 575 - 582
1 May 2023
Kato S Demura S Yokogawa N Shimizu T Kobayashi M Yamada Y Murakami H Tsuchiya H

Aims

Patients with differentiated thyroid carcinomas (DTCs) have a favourable long-term survival. Spinal metastases (SMs) cause a decline in performance status (PS), directly affecting mortality and indirectly preventing the use of systemic therapies. Metastasectomy is indicated, if feasible, as it yields the best local tumour control. Our study aimed to examine the long-term clinical outcomes of metastasectomy for SMs of thyroid carcinomas.

Methods

We collected data on 22 patients with DTC (16 follicular and six papillary carcinomas) and one patient with medullary carcinoma who underwent complete surgical resection of SMs at our institution between July 1992 and July 2017, with a minimum postoperative follow-up of five years. The cancer-specific survival (CSS) from the first spinal metastasectomy to death or the last follow-up was determined using Kaplan-Meier analysis. Potential factors associated with survival were evaluated using the log-rank test. We analyzed the clinical parameters and outcome data, including pre- and postoperative disability (Eastern Cooperative Oncology Group PS 3), lung and non-spinal bone metastases, and history of radioiodine and kinase inhibitor therapies.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 978 - 985
1 Sep 2024
Savoie III FH Delvadia BP Tate JP Winter JE Williams GH Sherman WF O’Brien MJ

Rotator cuff tears are common in middle-aged and elderly patients. Despite advances in the surgical repair of rotator cuff tears, the rates of recurrent tear remain high. This may be due to the complexity of the tendons of the rotator cuff, which contributes to an inherently hostile healing environment. During the past 20 years, there has been an increased interest in the use of biologics to complement the healing environment in the shoulder, in order to improve rotator cuff healing and reduce the rate of recurrent tears. The aim of this review is to provide a summary of the current evidence for the use of forms of biological augmentation when repairing rotator cuff tears.

Cite this article: Bone Joint J 2024;106-B(9):978–985.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims

This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height.

Methods

Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 239 - 246
1 Mar 2023
Arshad Z Aslam A Al Shdefat S Khan R Jamil O Bhatia M

Aims

This systematic review aimed to summarize the full range of complications reported following ankle arthroscopy and the frequency at which they occur.

Methods

A computer-based search was performed in PubMed, Embase, Emcare, and ISI Web of Science. Two-stage title/abstract and full-text screening was performed independently by two reviewers. English-language original research studies reporting perioperative complications in a cohort of at least ten patients undergoing ankle arthroscopy were included. Complications were pooled across included studies in order to derive an overall complication rate. Quality assessment was performed using the Oxford Centre for Evidence-Based Medicine levels of evidence classification.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 679 - 687
1 Jun 2023
Lou Y Zhao C Cao H Yan B Chen D Jia Q Li L Xiao J

Aims

The aim of this study was to report the long-term prognosis of patients with multiple Langerhans cell histiocytosis (LCH) involving the spine, and to analyze the risk factors for progression-free survival (PFS).

Methods

We included 28 patients with multiple LCH involving the spine treated between January 2009 and August 2021. Kaplan-Meier methods were applied to estimate overall survival (OS) and PFS. Univariate Cox regression analysis was used to identify variables associated with PFS.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 64 - 71
1 Jan 2023
Danielsen E Gulati S Salvesen Ø Ingebrigtsen T Nygaard ØP Solberg TK

Aims

The number of patients undergoing surgery for degenerative cervical radiculopathy has increased. In many countries, public hospitals have limited capacity. This has resulted in long waiting times for elective treatment and a need for supplementary private healthcare. It is uncertain whether the management of patients and the outcome of treatment are equivalent in public and private hospitals. The aim of this study was to compare the management and patient-reported outcomes among patients who underwent surgery for degenerative cervical radiculopathy in public and private hospitals in Norway, and to assess whether the effectiveness of the treatment was equivalent.

Methods

This was a comparative study using prospectively collected data from the Norwegian Registry for Spine Surgery. A total of 4,750 consecutive patients who underwent surgery for degenerative cervical radiculopathy and were followed for 12 months were included. Case-mix adjustment between those managed in public and private hospitals was performed using propensity score matching. The primary outcome measure was the change in the Neck Disability Index (NDI) between baseline and 12 months postoperatively. A mean difference in improvement of the NDI score between public and private hospitals of ≤ 15 points was considered equivalent. Secondary outcome measures were a numerical rating scale for neck and arm pain and the EuroQol five-dimension three-level health questionnaire. The duration of surgery, length of hospital stay, and complications were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims

Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice.

Methods

This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m2 (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims

Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes.

Methods

A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 610 - 621
1 Jun 2023
Prodromidis AD Chloros GD Thivaios GC Sutton PM Pandit H Giannoudis PV Charalambous CP

Aims

Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening.

Methods

A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1009 - 1010
1 Sep 2022
Haddad FS


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims

A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting.

Methods

This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 997 - 1002
1 Jul 2016
Sudo HS Mayer MM Kaneda KK Núñez-Pereira S Shono SY Hitzl WH Iwasaki NI Koller HK

Aims. The aims of our study were to provide long-term information on the behaviour of the thoracolumbar/lumbar (TL/L) curve after thoracic anterior correction and fusion (ASF) and to determine the impact of ASF on pulmonary function. Patients and Methods. A total of 41 patients (four males, 37 females) with main thoracic (MT) adolescent idiopathic scoliosis (AIS) treated with ASF were included. Mean age at surgery was 15.2 years (11 to 27). Mean follow-up period was 13.5 years (10 to 18). Results. For the TL/L curve, the mean curve flexibility evaluated with supine pre-operative bending radiographs was 78.6% (standard deviation 16.5%), with no significant loss of correction observed. On comparing patients with an increase of the TL/L curve increase (> 4º, n = 9, 22%) to those without, significant differences were observed in the correction rate of the MT curve at the final follow-up (p = 0.011), correction loss of the MT curve (p = 0.003) and the proportion of patients who had semi-rigid instrumentation (p = 0.003). Pre-operative percentage predicted forced vital capacity (%FVC) was 80%, dropping to 72% at final follow-up (p < 0.001). The Scoliosis Research Society questionnaire score was not significantly different between patients with and without a TL/L curve increase (p = 0.606). Spontaneous lumbar curve correction (SLCC) was maintained up to 18 years following selective ASF in most patients and demonstrated significant correlation with maintenance of MT curve correction. Conclusion. Maintenance of MT curve correction using rigid instrumentation provided stable SLCC over time. An observed 8% decrease in %FVC indicates that ASF should be reserved for patients with no or only mild pulmonary impairment. Cite this article: Bone Joint J 2016;98-B:997–1002


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1611 - 1619
1 Dec 2016
Wilson MJ Hook S Whitehouse SL Timperley AJ Gie GA

Aims. Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time. . Patients and Methods. Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died. Results. There were 76 further revisions (10.8%) involving the stem; seven for aseptic loosening, 23 for periprosthetic fracture, 24 for infection, one for malposition, one for fracture of the stem and 19 cement-in-cement exchanges of the stem during acetabular revision. The 20-year survival rate for the entire series was 98.8% (95% confidence interval (CI) 97.8 to 99.8) with aseptic loosening as the endpoint, and 87.7% (95% CI 82.8 to 92.6) for revision for any reason. Survival improved with the evolution of the technique, although this was not statistically significant due to the overall low rate of further revision. Conclusion. This is the largest series of revision total hip arthroplasties with femoral impaction grafting, and the results support the continued use of this technique. Cite this article: Bone Joint J 2016;98-B:1611–19


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 708 - 713
1 Jun 2017
Rushton PRP Siddique I Crawford R Birch N Gibson MJ Hutton MJ

The MAGnetic Expansion Control (MAGEC) system is used increasingly in the management of early-onset scoliosis. Good results have been published, but there have been recent reports identifying implant failures that may be associated with significant metallosis surrounding the implants. This article aims to present the current knowledge regarding the performance of this implant, and the potential implications and strategies that may be employed to identify and limit any problems. We urge surgeons to apply caution to patient and construct selection; engage in prospective patient registration using a spine registry; ensure close clinical monitoring until growth has ceased; and send all explanted MAGEC rods for independent analysis. The MAGEC system may be a good instrumentation system for the treatment of early-onset scoliosis. However, it is innovative and like all new technology, especially when deployed in a paediatric population, robust systems to assess long-term outcome are required to ensure that patient safety is maintained. Cite this article: Bone Joint J 2017;99-B:708–13


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 257 - 264
1 Feb 2022
Tahir M Mehta D Sandhu C Jones M Gardner A Mehta JS

Aims

The aim of this study was to compare the clinical and radiological outcomes of patients with early-onset scoliosis (EOS), who had undergone spinal fusion after distraction-based spinal growth modulation using either traditional growing rods (TGRs) or magnetically controlled growing rods (MCGRs).

Methods

We undertook a retrospective review of skeletally mature patients who had undergone fusion for an EOS, which had been previously treated using either TGRs or MCGRs. Measured outcomes included sequential coronal T1 to S1 height and major curve (Cobb) angle on plain radiographs and any complications requiring unplanned surgery before final fusion.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 229 - 237
1 Feb 2016
Roberts SB Dryden R Tsirikos AI

Aims. Clinical and radiological data were reviewed for all patients with mucopolysaccharidoses (MPS) with thoracolumbar kyphosis managed non-operatively or operatively in our institution. Methods. In all 16 patients were included (eight female: eight male; 50% male), of whom nine had Hurler, five Morquio and two Hunter syndrome. Six patients were treated non-operatively (mean age at presentation of 6.3 years; 0.4 to 12.9); mean kyphotic progression +1.5. o. /year; mean follow-up of 3.1 years (1 to 5.1) and ten patients operatively (mean age at presentation of 4.7 years; 0.9 to 14.4); mean kyphotic progression 10.8. o. /year; mean follow-up of 8.2 years; 4.8 to 11.8) by circumferential arthrodesis with posterior instrumentation in patients with flexible deformities (n = 6). Results. In the surgical group (mean age at surgery of 6.6 years; 2.4 to 16.8); mean post-operative follow-up of 6.3 years (3.5 to 10.3), mean pre-operative thoracolumbar kyphosis of 74.3. o. (42. o. to 110. o. ) was corrected to mean of 28.6. o. (0. o. to 65. o. ) post-operatively, relating to a mean deformity correction of 66.9% (31% to 100%). Surgical complications included a deep wound infection treated by early debridement, apical non-union treated by posterior re-grafting, and stable adjacent segment spondylolisthesis managed non-operatively. Thoracolumbar kyphosis > +38. o. at initial presentation was identified as predicting progressively severe deformity with 90% sensitivity and 83% specificity. Discussion. This study demonstrates that severe thoracolumbar kyphosis in patients with MPS can be effectively treated by circumferential arthrodesis. Severity of kyphosis at initial presentation may predict progression of thoracolumbar deformity. Patients with MPS may be particularly susceptible to post-operative complications due to the underlying connective tissue disorder and inherent immunological compromise. Take home message: Clinical and radiological data were reviewed for all patients with mucopolysaccharidoses with thoracolumbar kyphosis managed non-operatively or operatively in our institution. Cite this article: Bone Joint J 2016;98-B:229–37


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 103 - 111
1 Jan 2022
Li J Hu Z Qian Z Tang Z Qiu Y Zhu Z Liu Z

Aims

The outcome following the development of neurological complications after corrective surgery for scoliosis varies from full recovery to a permanent deficit. This study aimed to assess the prognosis and recovery of major neurological deficits in these patients, and to determine the risk factors for non-recovery, at a minimum follow-up of two years.

Methods

A major neurological deficit was identified in 65 of 8,870 patients who underwent corrective surgery for scoliosis, including eight with complete paraplegia and 57 with incomplete paraplegia. There were 23 male and 42 female patients. Their mean age was 25.0 years (SD 16.3). The aetiology of the scoliosis was idiopathic (n = 6), congenital (n = 23), neuromuscular (n = 11), neurofibromatosis type 1 (n = 6), and others (n = 19). Neurological function was determined by the American Spinal Injury Association (ASIA) impairment scale at a mean follow-up of 45.4 months (SD 17.2). the patients were divided into those with recovery and those with no recovery according to the ASIA scale during follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 351 - 359
1 Mar 1998
Lund T Oxland TR Jost B Cripton P Grassmann S Etter C Nolte L

We performed a biomechanical study on human cadaver spines to determine the effect of three different interbody cage designs, with and without posterior instrumentation, on the three-dimensional flexibility of the spine. Six lumbar functional spinal units for each cage type were subjected to multidirectional flexibility testing in four different configurations: intact, with interbody cages from a posterior approach, with additional posterior instrumentation, and with cross-bracing. The tests involved the application of flexion and extension, bilateral axial rotation and bilateral lateral bending pure moments. The relative movements between the vertebrae were recorded by an optoelectronic camera system. We found no significant difference in the stabilising potential of the three cage designs. The cages used alone significantly decreased the intervertebral movement in flexion and lateral bending, but no stabilisation was achieved in either extension or axial rotation. For all types of cage, the greatest stabilisation in flexion and extension and lateral bending was achieved by the addition of posterior transpedicular instrumentation. The addition of cross-bracing to the posterior instrumentation had a stabilising effect on axial rotation. The bone density of the adjacent vertebral bodies was a significant factor for stabilisation in flexion and extension and in lateral bending


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 34 - 40
1 Oct 2016
Emerson RH Alnachoukati O Barrington J Ennin K

Aims. Approved by the Food and Drug Administration in 2004, the Phase III Oxford Medial Partial Knee is used to treat anteromedial osteoarthritis (AMOA) in patients with an intact anterior cruciate ligament. This unicompartmental knee arthroplasty (UKA) is relatively new in the United States, and therefore long-term American results are lacking. Patients and Methods. This is a single surgeon, retrospective study based on prospectively collected data, analysing a consecutive series of primary UKAs using the Phase III mobile-bearing Oxford Knee and Phase III instrumentation. Between July 2004 and December 2006, the senior author (RHE) carried out a medial UKA in 173 patients (213 knees) for anteromedial osteoarthritis or avascular necrosis (AVN). . A total of 95 patients were men and 78 were women. Their mean age at surgery was 67 years (38 to 89) and mean body mass index 29.87 kg/m2 (17 to 62). The mean follow-up was ten years (4 to 11). Results. Survivorship of the Oxford UKA at ten years was 88%, using life table analysis. Implant survivorship at ten years was 95%. The most common cause for revision was the progression of osteoarthritis in the lateral compartment. The mean knee score element of the American Knee Society Score (AKSS) was 50 pre-operatively and increased to 93 post-operatively. The mean AKSS function score was 56 pre-operatively rising to 78 post-operatively. Conclusion. This ten-year follow-up study of the Oxford UKA undertaken in the United States shows good survivorship and excellent function in a wide selection of patients with AMOA and AVN. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):34–40


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 95 - 99
1 Nov 2012
Barrack RL Ruh EL Williams BM Ford AD Foreman K Nunley RM

Patient specific cutting guides generated by preoperative Magnetic Resonance Imaging (MRI) of the patient’s extremity have been proposed as a method of improving the consistency of Total Knee Arthroplasty (TKA) alignment and adding efficiency to the operative procedure. The cost of this option was evaluated by quantifying the savings from decreased operative time and instrument processing costs compared to the additional cost of the MRI and the guide. Coronal plane alignment was measured in an unselected consecutive series of 200 TKAs, 100 with standard instrumentation and 100 with custom cutting guides. While the cutting guides had significantly lower total operative time and instrument processing time, the estimated $322 savings was overwhelmed by the $1,500 additional cost of the MRI and the cutting guide. All measures of coronal plane alignment were equivalent between the two groups. The data does not currently support the proposition that patient specific guides add value to TKA