The MAKO Robotic arm is a haptic robotic system that can be used to optimise performance during total hip arthroplasty (THA). We present the outcome of the first 40 robotic cases performed in an NHS foundation trust along with the technique of performing robotic THA in our unit. Forty consecutive patients undergoing robotic THA (rTHA) were compared to a case matched group of patients undergoing manual THA (m-THA). 2:1 blinded case matching was performed for age, sex, implants used (Trident uncemented socket and cemented Exeter stem, Stryker Mahwah, NJ, US) and surgeon grade. Comparisons were made for radiological positioning of implants, including leg length assessment, and patient reported functional outcome (PROMS). Pre- and post-operative radiographs were independently analysed by 2 authors. All patients underwent THA for a primary diagnosis of osteoarthritis. No significant difference between groups was identified for post-operative leg length discrepancy (LLD) although pre-operatively a significantly higher LLD was highlighted on the MAKO group, likely due to patient selection. Significantly lower post-operative socket version was identified in the MAKO cohort although no difference in post-operative cup inclination was noted. However, there was significantly larger variance in post-op LLD (p=0.024), cup version (p=0.004) and inclination (p=0.05) between groups indicating r-THA was significantly less variable (Levene's test for homogeneity of variance). There was no significant difference in the number of cases outside of Lewinnek's ‘safe’ zone for inclination (p=0.469), however, there were significantly more cases outside Lewinnek's ‘safe’ zone for version (12.5% vs 40.3%, p=0.002) in the m-THA group. We report the commencement of performance of MAKO robotic THA in an NHS institution. No problems with surgery were reported during our learning curve. Robotic THA cases had less variability in terms of implant positioning suggesting that the MAKO robot allows more accurate, less variable implant positioning with fewer outliers. Longer term follow-up of more cases is needed to identify whether this improved implant positioning has an effect on outcomes, but the initial results seem promising.
The Exeter V40 femoral stem is the most implanted stem in the NJR for primary THA. In 2004, the 44/00/125 stem was released for use in “cement-in-cement” revision cases. It has however been used ‘off-label’ as a primary stem when, for example, patient anatomy requires a smaller stem with a 44mm offset. We aimed to investigate survival of this stem in comparison to others in the range when used in primary THAs recorded in the NJR. Analyses were performed using a dataset based on that used for the 2020 NJR annual report. Our exposure was the stem; the outcome was all-cause construct revision. Crude analyses were performed using Kaplan-Meier and adjusted using Cox models. The 44/00/125 stem was directly compared to other stems in the Exeter range. We analysed 330,732 primary THAs using the Exeter V40 stem comprising 34.5% of the 958,869 THAs with complete information from the start of the NJR to 31 December 2018. The 44/00/125 stem was implanted in 2,158 primary THAs with 67.5% in female patients and a mean age of 67.8. The 10-year revision estimate for the 44/00/125 stem was 4.9% (95%CI 3.6, 6.8) and in constructs using an Exeter V40 stem was 2.8% (95%CI 2.7, 2.8). Controlling for age, sex and ASA demonstrated an increased overall hazard of revision for constructs using the 44/00/125 stem compared to constructs using other Exeter V40 femoral stems (HR 1.8 (95%CI 1.4, 2.3)). Although the revision estimate is within the NICE 10-year benchmark, survivorship of constructs using the 44/00/125 stem appears to be lower than the rest of the Exeter V40 range. Attempts to control for age, sex and ASA will not take into account confounding by indication i.e. patients with more complex anatomy who may have a higher risk of revision. Surgeons and patients should be reassured by this but should be aware of the observed increased revision estimate and use the stem according to its indications.
Total hip replacements (THRs) provide pain relief and improved function to thousands of patients suffering from end-stage osteoarthritis, every year. Over 800 different THR constructs were implanted in the UK in 2017. To ensure reliable implants are used, a NICE revision benchmark of 5% after 10 years exists. Given the 10-year cumulative mortality of patients under 55 years of age receiving THRs is only 5% and that a recent study suggests 25-year THR survival of 58%, we aim to produce revision estimates out to 30 years that may guide future long-term benchmarks. The local database of the Princess Elizabeth Orthopaedic Centre (PEOC), Exeter, holds data on over 20,000 patients with nearly 30-years follow-up with contemporary prostheses. A previous study suggests that the results of this centre are generalisable if comparisons restricted to the same prostheses. Via flexible parametric survival analysis, we created an algorithm using this database, for revision of any part of the construct for any reason, controlling for age and gender. This algorithm was applied to 664,761 patients in the NJR who have undergone THR, producing a revision prediction for patients with the same prostheses as those used at this centre. Using our algorithm, the 10-year predicted revision rate of THRs in the NJR was 2.2% (95% CI 1.8, 2.7) based on a 68-year-old female patient; well below the current NICE benchmark. Our predictions were validated by comparison to the maximum observed survival in the NJR (14.2 years) using restricted mean survival time (P=0.32). Our predicted cumulative revision estimate after 30 years is 6.5% (95% CI 4.5, 9.4). The low observed and predicted revision rate with the prosthesis combinations studied, suggest current benchmarks may be lowered and new ones introduced at 15 and 20 years to encourage the use of prostheses with high survival.
The principle function of the “short external rotator” muscle group is primarily as an abductor and extensor of the flexed hip and is better referred to as the “Quadriceps Coxa” (QC). The QC has a profound influenced on weight bearing rising and propulsive motions. The SPAIRE technique preserves Obturator Internus (OI) and Piriformis (P) resulting in improved stability of the hip and potentially improved recovery and function in patients undergoing hip arthroplasty. Short term outcomes of the first 42 consecutive SPAIRE cases are compared with 86 consecutive cases using the traditional posterior approach that immediately preceded introduction of the technique. The purpose was to document the learning curve and confirm the safety of introducing SPAIRE into routine clinical practice. The two groups were comparable and there was no statistically significant difference in length of stay, blood loss, intra-or post-operative complications nor radiological measurements relating to the femoral or acetabular components. Statistically significant differences were found for component usage (more uncemented acetabula for SPAIRE), length of operation (8 mins longer with SPAIRE); patient satisfaction was higher at 6 weeks and measured leg length discrepancy less in the SPAIRE group. SPAIRE has been used routinely for all routine arthroplasties for over two years. RCTs are ongoing to document the effect of SPAIRE on recovery, long term function and activity level. If the potential benefits are confirmed SPAIRE may become the default technique for hip arthroplasty operations through a posterior approach for elective and hip fracture cases.