Abstract

The principle function of the “short external rotator” muscle group is primarily as an abductor and extensor of the flexed hip and is better referred to as the “Quadriceps Coxa” (QC). The QC has a profound influenced on weight bearing rising and propulsive motions. The SPAIRE technique preserves Obturator Internus (OI) and Piriformis (P) resulting in improved stability of the hip and potentially improved recovery and function in patients undergoing hip arthroplasty.

Short term outcomes of the first 42 consecutive SPAIRE cases are compared with 86 consecutive cases using the traditional posterior approach that immediately preceded introduction of the technique. The purpose was to document the learning curve and confirm the safety of introducing SPAIRE into routine clinical practice.

The two groups were comparable and there was no statistically significant difference in length of stay, blood loss, intra-or post-operative complications nor radiological measurements relating to the femoral or acetabular components. Statistically significant differences were found for component usage (more uncemented acetabula for SPAIRE), length of operation (8 mins longer with SPAIRE); patient satisfaction was higher at 6 weeks and measured leg length discrepancy less in the SPAIRE group.

SPAIRE has been used routinely for all routine arthroplasties for over two years. RCTs are ongoing to document the effect of SPAIRE on recovery, long term function and activity level. If the potential benefits are confirmed SPAIRE may become the default technique for hip arthroplasty operations through a posterior approach for elective and hip fracture cases.