header advert
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2016
Borus T Roberts D Fairchild P Christopher J Conditt M Branch S Matthews J Pirtle K Baer M
Full Access

Introduction

Unicompartmental Knee Arthroplasty (UKA) has been offered as a tissue sparing alternative to total knee arthroplasty (TKA) for treatment of early to mid-stage osteoarthritis (OA). While the spared tissue and retention of cruciate ligaments may result in faster recovery, smaller incision, less bone resection, decreased pain and blood loss and more normal kinematics and function, UKA has shown unpredictable results in practice, which may be due to variations in surgical techniques1. Recently a robotic-assisted technique has been introduced as a means to provide more consistent and reproducible surgical results. In this study, the early return to function was measured to determine proposed benefits between UKA and TKA.

Methods

Patients requiring either UKA or TKA were prospectively enrolled in this IRB approved study. Each patient received pre-operative education regarding their expected physical therapy (PT) regimen, which was uniform for all patients. PT was determined to be concluded when each patient reached an achievable functional endpoint with each of the following 5 criteria: range of motion from 5 to 115 degrees, recovery of flexion and extension strength to 4/5 of pre-operative strength, gait with minimal limp and without an assistive device for 250 feet and ability to ascend and descend a flight of stairs with step over gait and good control. The number of PT visits to reach each functional goal was recorded.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 18 - 18
1 Jun 2015
Roberts D Power D Stapley S
Full Access

Scapula fractures mostly occur following high energy trauma, however, the demographics are unknown in deployed soldiers. We analysed the incidence, aetiology, associated injuries, treatment and complications of these fractures in military personnel from Afghanistan and Iraq (2004–2014). Forty-four scapula fractures from 572 upper limb fractures (7.7%) were sustained. 85% were caused by blast or gunshot wounds and 54% were open blast fractures. Multiple injuries were noted including lung, head, vascular and nerve injuries. Injury Severity Scores were almost double compared to the average upper limb injury without a scapula fracture (21 vs. 11). Brachial plexus injuries (17%) have a favourable outcome following GSW compared to blast injuries. Glenoid fractures or floating shoulders were internally fixed (10%) and resulted from high velocity gunshot wounds or mounted blast ejections. There were no cases of deep soft tissue infection or osteomyelitis and all scapula fractures united. Scapula fractures have a 20 times higher incidence in military personnel compared to the civilian population. These fractures are often associated with multiple injuries, including brachial plexus injuries, where those sustained from blast have less favourable outcome. High rates of union following fixation and low rates of infection are expected despite significant contamination and soft tissue loss.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 19 - 19
1 Jun 2015
Roberts D Power D Stapley S
Full Access

Major upper limb arterial injuries sustained in combat are associated with significant trauma. We analysed the survival and complication rates following upper limb vascular injury in Iraq and Afghanistan (2004–2014). Fifty-two soldiers sustained 59 major arterial injuries in 54 limbs. Axillary artery injuries were more likely to be caused by gunshot wounds (86%), whilst brachial and ulnar artery injuries were primarily associated with blasts (72% and 87% respectively); no such correlation was identified with radial artery injuries. Apart from three temporary shunts, all vascular injuries were treated definitively in the local field hospital before repatriation. Proximal injuries were predominantly treated with long saphenous vein grafts and distal injuries with ligation. One soldier required an immediate amputation following failed LSV grafting, however no amputations followed repatriation. There were five identified graft failures (21%), although these were not associated with subsequent perfusion issues. There were no graft failures following temporary shunting. Associated nerve injuries often required operative intervention and have a guarded outcome. 100% of radial fractures went onto non-union if combined with a radial artery injury. Successful immediate re-perfusion of a vascular compromised upper limb correlates with excellent long-term limb survival, despite a significant number of grafts developing secondary failure.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 41 - 43
1 Oct 2014
Roberts D Cole AS


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_11 | Pages 13 - 13
1 Feb 2013
Roberts D Jones S Uglow M
Full Access

Aim

To determine if the instigation of Magnetic Resonance Extremity (MRE) scanning in our unit as part of the management of suspected paediatric scaphoid fractures has prevented overuse of splints or casts reduced unnecessary clinic appointments and saved our department financially.

Methods

Children with traumatic anatomical snuffbox tenderness and negative radiographs are seen 10 days following injury having been given a Futura® splint. If repeat radiographs are negative with on-going positive clinical findings the child has an MRE scan, which is usually reported the same day. If negative, the splint is removed on that day, but if positive, a cast is applied and the child referred onto paediatric fracture clinic.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 2 - 2
1 Feb 2013
Roberts D Panagiotidou A Calder P
Full Access

Purpose

To investigate the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) with external fixator use and to help establish whether current guidelines are appropriate.

Methods

Case notes of individuals undergoing external fixator application by the senior author (PC) from March 2005 to June 2011 were examined. In this period 207 individuals underwent 255 primary applications of Ilizarov, Taylor Spatial Frame (TSF) or monolateral fixator. Fixators applied were 173 tibial, 63 femoral and 19 to other bones. Records were obtained for 182 individuals (88%), representing 214 operations (84%).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 222 - 222
1 Jan 2013
Roberts D Panagiotidou A Calder P
Full Access

Introduction

No published work exists regarding deep vein thrombosis (DVT) and pulmonary embolism (PE) incidence with the elective use of external fixators. The aim of this work was to establish the rate of DVT and PE in such cases to help inform whether thromboprophylaxis guided by risk factors is adequate or if a more aggressive approach is required.

Patients and methods

Information from a prospectively maintained electronic database and case notes were examined for consecutive patients from March 2005 to June 2011. Occurrence of DVT and PE, detected by ultrasound or CT angiogram, were recorded. Risk factors for thromboembolism, age, weight, height, surgical indications, type of surgery and operative time were recorded. As recommended by the National Institute for Health and Clinical Excellence (NICE) thromboprophylaxis use is guided by risks of thromboembolism and bleeding. For adults and older adolescent patients contralateral leg compression stockings and an intraoperative calf pump were used. Mobilisation began the morning after surgery and the majority of cases permitted to bear weight fully.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 557 - 557
1 Sep 2012
Roberts D Garlick N
Full Access

Introduction

Dislocation following total hip arthroplasty THA is a major short term complication not infrequently resulting in revision arthroplasty. Malposition of the acetabular component in THA results in a higher rate of dislocation as well as increased wear and osteolysis. The aim of this study was to assess the effect of mode of fixation on positioning of the acetabular component.

Patients, materials and methods

For all THAs performed at our hospital in 2008, angle of acetabular inclination was measured using PACS by two independent observers. Interobserver and intraobserver reliability were assessed (Pearson's correlation coefficient, r). We determined whether the number of acetabular components outside the target angle range (eg:45±5°) was significantly different between cemented and cementless THA (chi squared test). An enquiry was made to the National Joint Registry (NJR) in respect to incidence of revision for dislocation of THA using cemented and cementless acetabular components, 2004–2009.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 66 - 66
1 Feb 2012
Noorani A Roberts D Malone A Waters T Jaggi A Lambert S Bayley I
Full Access

Introduction

The Stanmore Percentage of Normal Shoulder Assessment (SPONSA) is a simple, fast and reproducible measure of the subjective state of a shoulder. It has been invaluable in our busy clinical practice. This study validates the SPONSA score against the Oxford Shoulder and Constant score and demonstrates a greater sensitivity to change.

Methods

The SPONSA involves defining the concept of ‘normality’ in a shoulder and then asking patients to express the current state of their shoulder as a percentage of normal. The score uses a specific script which is read exactly as typed.

The SPONSA, Oxford Shoulder and Constant scores were measured by an independent observer in 61 consecutive patients undergoing treatment for shoulder conditions in our unit. Scores were recorded at 2-6 weeks before admission, immediately before intervention, and between 3-6 months post-intervention. The time taken to measure each score was recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_I | Pages 50 - 50
1 Jan 2012
Roberts D Ong B
Full Access

The difficulties in the management of chronic lower back pain are recognised by professionals and patients alike but this recognition can stem from very different perspectives. This paper discusses how patients identify ways in which their experience and perception of pain changes over time and how that impacts on their relationship with professionals delivering a treatment regime. It presents the results of secondary analysis of longitudinal patient data collected under a serial qualitative interview methodology in which the analytical focus is on patients' changing expectations and perceptions of pain. This orientation to the data demonstrates not only established notions of ‘acceptance’ within biographical disruption, but also ways in which individuals revise, mediate, negotiate and integrate meanings of pain to gain both short and long-term coherence. By taking a more holistic view of patient narratives that situates treatment prescriptions and related behaviours within the context of individuals' everyday life, the analysis highlights ‘sense-making’ as a dynamic process. In doing so, it shows that patients draw reference points not only from their most immediate experiences of chronic low back pain but also from the (dis)continuities of lifecourse experience prior to the onset of pain and anticipated for the future. The paper therefore seeks to both illuminate the dynamics of the patient perspective and provide indicators of where some differences in patient/professional perceptions may lie. Suggestions for promoting concordance between patients and health care professionals will be discussed.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 478 - 478
1 Aug 2008
Roberts D Shanbhag V Coakley M Jones A Davies P Howes J Ahuja S
Full Access

Paravertebral anaesthesia is a particularly effective, safe and reliable option in scoliosis patients undergoing anterior release in whom percutaneous epidural placement may be difficult to perform. A recent systematic review and meta-analysis of randomized trials has demonstrated that whilst paravertebral block and thoracic epidural insertion provide comparable pain relief after thoracic surgery, paravertebral block placement is associated with a better side effect profile, including a reduction in pulmonary complications, hypotension, nausea and vomiting and urinary retention. We describe a case of a 16 year old female patient who underwent staged correction of her thoracolumbar scoliosis. A paravertebral catheter was inserted under direct vision for continuous infusion post operative analgesia following the anterior release. 48 hours after surgery a swelling was noted in the groin, which was confirmed with ultrasonography as a fluid collection. The swelling resolved upon removing the paravertebral catheter. This suggests that it was caused by the local anaesthetic fluid tracking along the psoas muscle. Retroperitoneal infections, venous thrombosis, femoral hernia, femoral artery aneurysm and inguinal lymphadenopathy are other differentials. Ultrasonography was a fast and sensitive investigation to rule out these differentials and determined that fluid communicating with the abdominal cavity was the cause for this swelling. The infused local anaesthetic had tracked down into the femoral triangle and the swelling resolved upon cessation of the infusion.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 480 - 480
1 Aug 2008
Shanbhag V Roberts D Turner B Jones A Howes J Davies P Ahuja S
Full Access

Background data: Previous studies have questioned the quality of information available on the internet. Internet research has proven to more prevalent among scoliosis patients as compared to other orthopaedic conditions.

Aim: Scoliosis websites identified by commonly used search engines were assessed for quality and medical accuracy.

Methods: The word scoliosis was entered into top six search engines and Websites ranked according to frequency. Five websites from the worldwide web and five from the UK only search were evaluated by medical professionals – 4 spinal consultants, 2 registrars, 3 nurses and 1 physiotherapist. 10 patients/carers who had scoliosis surgery also assessed these sites. A scale of 1 to 5 was used for ease of understanding, reliability, clinical correlation, adequacy and links and average score calculated.

Results: None of the top five UK websites figured in the top 5 WWW searchs. Scoliosis research society (SRS) and American Academy of Orthopaedic Surgeons (AAOS) website scored the highest by clinicians and patients in the www list. From the UK list, SAUK website scored the highest with both groups followed by Great Ormond Street Hospital (GOSH) website. We compared the assessment of websites by a healthcare professionals and by patients who had undergone treatment and showed no statistical difference in the scoring.

Conclusion: As treating clinicians it is necessary to educate patients by guiding them to reliable internet sites like SAUK and SRS.