Total hip arthroplasty (THA) has been efficacious for treating hip fractures. However, in these patients with fractures a widely variable prevalence of dislocation has been reported, partly because of varying durations of follow-up for this specific end-point. The purpose of the present study was to determine the risk of dislocation as a function of time after total hip arthroplasty in these patients with fractures and to investigate if constrained liners influence the cumulative risk of dislocation. Between 2000 and 2005, 425 patients with neck fracture underwent primary THA using a constrained acetabular liner (Cemented retentive cup, Groupe lépine, Genay, France). The results of these 425 constrained acetabular liners were compared with 380 THA without constrained liners performed for neck fractures between 1994 and 1999 in the same hospital. All patients were followed for a minimum of 5 years for radiographic evidence of implant failure. The patients were followed at routine intervals and were specifically queried about dislocation. The cumulative risk of dislocation was calculated with use of the Kaplan-Meier method. For patients without constrained liners, the cumulative risk of a first-time dislocation was 5% at one month and 12% at one year and then rose at a constant rate of approximately 2% every five years to 17% at five years, 19% at ten years, 21% at 15 years for patients who were alive and had not had a revision by that time. For patients with constrained liners, the cumulative risk of a first-time dislocation was 1% at one month, 2% at one year and then did not changed at 5 years and at 10 years for patients who were alive and had not had a revision by that time. Multivariate analysis revealed that the relative risk of dislocation for female patients (as compared with male patients) was 2.1 and that the relative risk for patients who were 80 years old or more (as compared with those who were less than 80 years old) was 1.5. Two underlying diagnoses - cognitively impaired patients or neurologic desease—were also associated with a significantly greater risk of dislocation. At minimum 7 year follow up (range 5 10 yrs), there were 8 radiographic failures (dislocations) of the 425 constrained liners (2%), and no loosenings were noted. The cumulative long-term risk of dislocation for patients with hip fractures is considerably greater than has been reported in short-term studies. The incidence of dislocation is highest in the first year after arthroplasty and then continues at a relatively constant rate for the life of the arthroplasty. Patients at highest risk are old female patients and those with a diagnosis of neurologic desease. Constrained liners in these patients is an efffective technique to prevent post operative hip dislocation.Results
Conclusions
This study reports the results of percutaneous autologous bone marrow grafting in 62 patients with corticosteroids treatment who had one hip osteonecrosis treated with bone marrow (BM) injection and the other contralateral hip osteonecrosis with core decompression (CD) alone. Only patients with bilateral symptomatic osteonecrosis and with those hips at stage I or II (as defined by Steinberg) were included in this study. Between 1988 and 1995, 62 consecutive patients (28 males and 34 females) were included in this study. These patients had a mean age of 31 years (range 18 to 34 years) at the time of the onset of symptoms. The average follow-up was 17 years (range, 15 to 20 years). An average of 152 + 16 milliliters of marrow was aspirated from the iliac crest. The number of stroma progenitor that was transplanted was estimated by counting the Fibroblast Colony Forming Units which express type I and type III collagen. The bone marrow graft obtained after concentration contained average 4889 + 716 progenitors per cubic centimeter (range 3515 to 6293 per cubic centimeter). Each hip received a mean number of thirty cubic centimeters of bone marrow graft (range 27 to 35 cubic centimeters). The average total number of CFU-F injected in each hip was therefore 147 × 103 cells (range 119 × 103 to 195 × 103 cells).Introduction
Material and Methods
From a theoritical point of vue, experience is an important factor in obtaining a satisfactory result in arthroplasty surgery. We wished to determine whether standard posterior stabilized total knee replacement (PS TKA) performed by young surgeons (Group A) increased rates of mortality and complications compared with PS TKA performed by senior surgeons (Group B) using the same model of arthroplasty. Between 1990 and 1995, 195 patients underwent 250 total knee arthroplasties in the same orthopaedic university department of the hospital by two senior surgeons (100 TKA; Group B) and 12 younger surgeons without senior assistance (150 TKA; Group A). The procedures were undertaken consecutively and the implant was always the same. There were no significant pre-operative differences between the groups in terms of age, gender, height, weight, body mass index, diagnosis, comorbidity and duration of follow-up, which was more than 15 years in both groups. Pre-and postoperative assessments were made according to the system of the Knee Society. The preoperative and postoperative deformities were measured on weight-bearing radiographs of the whole limb (hip-knee-ankle angle). The mean Knee Society knee and functional scores were not significantly different (p = 0.125) pre-operatively: 37.5 points (16 to 53) and 15 points (0 to 20) respectively in the Group B, and 36.0 points (10 to 58) and 17 points (0 to 30) respectively in the Group A; and at final follow-up (p = 0.145): 91 points (42 to 100) and 82 points (25 to 100) respectively in the Group B, and 89 points (58 to 100) and 84 points (35 to 100) respectively in the Group A. The rate of survival at ten years, with revision as the endpoint for failure, was 96% (95% CI, 93 to 100) in both groups; at fifteen years 91% (95% CI, 85 to 97) in group B, and 92% (95% CI, 90 to 94) in group A. There were no significant differences in revision rates in Group B or Group A (p = 0.735). In the Group B group, 1 knee (0.6%) revised for osteolysis, 1 (0.6%) deep infection, 1 (0.6%) aseptic loosening, and 1 (0.6%) for fracture. In the Group A, 1 knee (1%) revised for deep infection, none for osteolysis and 2 (2%) for aseptic loosening, and one for dislocation. In this series surgeons in the early stages of their careers achieved the same results as seniors; so this study is very reassuring for patients undergoing surgery in a university hospital. Our study has however limitations. All the patients received cemented TKA in a large-volume centre specialising in joint reconstruction. It is not a randomised-controlled trial; but it would be impossible to perform one. Would really patients sign up to a study where they would be randomised between an inexperienced and experienced surgeon? What is difficult to assess is how the ‘learning curve’ of one implant affects the ‘learning curve’ for a different implant.
Maltracking or subluxation is one of the complication of patellofemoral arthroplasty (PFA). The purpose of this investigation was to measure femoral component rotational alignment in PFA using a standard computed tomography (CT) scanner. Second, apply this technique to two groups; a control group of patients with well functioning PFA and a study of a group of patients with patellofemoral problems as maltracking or subluxation. Data was analyzed from our center that has continuously performed PFA for isolated patellofemoral degenerative disease since 1978. Patients were included if they had a minimum four year follow up. A total of 124 patients (149 knees) were treated with PFA. There were 39 men and 85 women who had a mean age of 64 years (range, 46 to 78 years). A pre-operative and post-operative CT scan is performed in our center for all the patients since this period to assess femoro-patellar malalignment. The trochlear twist angle was determined using the single axial CT image through the femoral epi-condyles. To determine whether the femoral component was in excessive internal or external rotation, measurements were done on the post-operative CT scan and the trochlear twist angle of the femoral component was compared to the pre-operative trochlear twist angle. At a mean follow up of 13 years (range, 4 to 30 years), overall prosthetic survival and preservation was 91 per cent. There were 112 knees (75 per cent) with good or excellent clinical results (Knee Society score of 80 points or more). Revision to total knee replacement for femoro-tibial disease progression was necessary in 9 knees (6 per cent). Complications related to the patellofemoral arthroplasty (28 knees) included : residual pain or mechanical symptom 10 (7 per cent) requiring other ancillary procedures ; maltracking or subluxation 18 (12%) with component revision in 10 knees; Radiographic findings show 2 component loosenings and 1 patella fracture. There was no incidence of infection or component wear. The group with patellofemoral complications had excessive (p less than 0.01) femoral internal component rotation. This excessive combined internal rotation was directly proportional to the severity of the patellofemoral complication. Small amounts of internal rotation (1–4 degrees) correlated with pain. Moderate combined internal rotation (5–10 degrees) with lateral tracking and patellar tilting. Large amounts of combined internal rotational (10–17 degrees) correlated with patellar sub-luxation, early patellar dislocation or late patellar prosthesis failure (fracture of the patella or loosening of the patella button). The control group (112 knees without complications) was in external rotation (10-0 degrees). This study showed that increasing amounts of excessive internal rotational malalignment resulted in more severe patellofemoral complications.
The purpose was to assess the effect of the posterior slope on the long-term outcome of unicompartmental arthroplasty in knees with intact and deficient anterior cruciate ligaments. We retrospectively reviewed ninety-nine unicompartmental arthroplasties after a mean duration of follow-up of sixteen years (12 to 20 years). At the time of the arthroplasty, the anterior cruciate ligament was considered to be normal in fifty knees, damaged in thirty-one, and absent in eighteen. At the most recent follow-up, we measured the posterior tibial slope and the anterior tibial translation on standing lateral radiographs. In the group of seventy-seven knees that had not been revised by the time of the most recent follow-up, there was a significant linear relationship between anterior tibial translation (mean, 3.7 mm) and posterior tibial slope (mean, 4.3) (p = 0.01). The mean posterior slope of the tibial implant was significantly less in the group of seventy-seven knees without loosening of the implant than it was in the group of seventeen knees with loosening of the implant (p = 0.03). Five ruptures of the anterior cruciate ligament occurred in knees in which the ligament had been considered to be normal at the time of implantation; the posterior tibial slope in these five knees was greater than 13 degrees. Clinical evaluation revealed normal or nearly normal anteroposterior stability at the time of the most recent follow-up in all sixty-six unrevised knees in which the anterior cruciate ligament had been present at the time of implantation. Of the eighteen knees in which the anterior cruciate ligament had been absent at the time of the arthroplasty, eleven still had the implant in situ at the time of the most recent follow-up; the mean posterior tibial slope in these 11 knees was less than 5 degrees. Seven knees in which the anterior cruciate ligament had been absent at the time of the arthroplasty were revised. In these 7 knees, the tibial prosthesis was implanted with a posterior slope greater than 8 degrees. These findings suggest that more than 7 degrees of posterior slope of the tibial implant should be avoided, particularly if the anterior cruciate ligament is absent at the time of implantation. An intact anterior cruciate ligament, even when partly degenerated, was associated with the maintenance of normal anteroposterior stability of the knee for an average of sixteen years following unicompartmental knee arthroplasty.
We studied hips with these two different ceramics during the same period and with a minimum follow-up of 15 years. Because the sizes of the alumina and zir-conia heads were different, hips with 32 mm alumina heads and those with 28 mm zirconia heads were compared with control hips with stainless-steel heads of the same sizes. The same stem and the same PE cup were implanted with cement at the same period. The femoral head was made of alumina with a diameter of 32 mm in 62 cases, and made of yttrium-oxide-partially-stabilized zirconia with a diameter of 28 mm in 40 cases. These ceramic heads were compared with 32 and 28 mm stainless steel heads (40 hips) There was an increased linear rate of penetration of the femoral heads into the liner between years five and 15 for the zirconia and the stainless-steel groups. This was severe in the zirconia group (0.4 mm/year compared with 0.13 mm/year for the stainless-steel group). During the same 15-year period there was, however, no significant change in the rate of wear in the alumina group (0.07 mm/year). The mean wear at the most recent follow-up was 1740 mm3 for the 28 mm zirconia group, 842 mm3 for the 28 mm stainless-steel group, 825 mm3 for the 32 mm alumina group and 1416 mm3 for the 32 mm stainless-steel group. The three femoral heads retrieved in the zirconia group were analysed using x-ray diffraction. The transformation rate of the tetragonal to the monoclinic crystal was 19 mol%, 25 mol% and 30 mmol% respectively. By comparison, the percentage of monoclinic phase was 4 mol% on a non-implanted femoral head at its surface. Their surface roughness was increased. Scanning electron microscopy of the surface of the retrieved heads showed more craters than on the zirconia heads before implantation. Changes were observed in the volume and sphericity of the retrieved heads. Their volume was measured by fluid displacement and had increased respectively by 0.5%, 0.7% and 1.1%. This variation was greater than that due to manufacturing tolerances . The morphological appearance of the surface of the retrieved cups was inspected. The most surprising change was found on the periphery of one cup with an increase in volume of the polyethylene on the non-articular surface of the liner as if the polyethylene had melted and then cooled. Although experimental studies have shown encouraging results, the long term clinical results of zirconia are not favorable.
In a society dependent upon the motor car, impaired driving ability is a significant disability which may affect patients with total knee replacement during the postoperative rehabilitation. Recently, there has been much interest in minimally invasive surgery for total knee arthroplasty (TKA). This study evaluated the hypothesis that a minimally invasive technique using a small incision (7 to 10 cm), and a minimal quadriceps muscle splitting without eversion of the patella (MIS approach) would have a beneficial effect on driving reaction time. 15 patients undergoing a primary TKA with the MIS approach were compared with 15 TKAs using a standard approach. An experimental car was used to measure the force and timing of pressure by the foot on accelerator and break pedals. The mean reaction time for normal adults was 0.442 s to go from the accelerator to the brake pedal. This time falls well within the code guideline of 0.7 s. The driving reaction times of the patients with knee arthroplasty were measured at one, two and three months after the operation. The ability to perform an emergency stop was assessed as the time taken to achieve a brake pressure of 100 N after a visual stimulus.The patients have an actual follow-up of 2 years. A clinical and radiological evaluation was performed. Radiographic analysis included evaluation of postoperative alignment variables and progressive radioluciencies. Over all 27 among the 30 knees have good and excellent objective knee Society Scores and patient satisfaction indices. The patients in the MIS group had a statistically shorter time until they could straight leg raise, used less epidural analgesia, used less overall analgesics and had a more rapid regaining of flexion. Patients with standard approach and technique for total knee replacement recovered sufficient knee function to return to driving at only three months after the operation according to the time and the force necessary to the brake pedal. Patients with mini invasive surgery approach have recovered sufficient knee function to return driving at one month after the operation. There was no significant difference in alignment of implants and in alignment of the knee between the two groups. Three knees had radioluciencies (two with a standard incision and one with a MIS approach). Using a small incision without patellar eversion does not jeopardize the alignment of the implants and improves postoperative rehabilitation.