Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 9 - 9
1 Aug 2022
Ali C Nazar N Silk Z Shafafy R Gibson A Noordeen H
Full Access

Less invasive single-rod fusion technique may be indicated in the management of NMS to minimise operative time, blood loss and wound-related complications. This retrospective 12-year cohort study (2008–2020) aims to evaluate and compare the outcomes of this technique to the current standard dual rod technique to determine their safety and efficacy.

28 patients in the single rod group (Mean age = 16.4 [SD ±4.0]) and 30 in the double rod group (Mean age = 16.3 [SD±3.5]). Indications included a minimum 2 year follow period, detailed information on the type of implant and a complete pre- and post-operative imaging and medical records. Baseline demographics, comorbidities, and surgical characteristics were collected. Outcomes assessed included the immediate post-op and final follow up angles and general complications. All outcome analysis was performed using a regression approach.

Angles at final follow-up: lumbar (Difference ratio (DR)= 2.60 [95% CI 0.37 – 18.4], p=0.25), thoracic (DR= 1.08 [95% CI 0.19 – 6.28], p=0.92), thoracolumbar (major curve angle) (DR 1.35 [95% CI 0.60 – 3.06], p=0.46) and kyphosis (DR = 0.97 [0.66, 1.42] p=0.86). There was no statistically significant difference, between the two groups, for any of the above angle outcomes as well as for length of surgery, blood loss and complication outcomes.

Both single and double rod instrumentation achieves satisfactory and safe deformity correction which is maintained at final follow up. A larger scale study is warranted to further assess these techniques while also conducting a cost-benefit analysis between them.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1368 - 1374
3 Oct 2020
McDonnell JM Ahern DP Lui DF Yu H Lehovsky J Noordeen H Molloy S Butler JS Gibson A

Aims

Whether a combined anteroposterior fusion or a posterior-only fusion is more effective in the management of patients with Scheuermann’s kyphosis remains controversial. The aim of this study was to compare the radiological and clinical outcomes of these surgical approaches, and to evaluate the postoperative complications with the hypothesis that proximal junctional kyphosis would be more common in one-stage posterior-only fusion.

Methods

A retrospective review of patients treated surgically for Scheuermann’s kyphosis between 2006 and 2014 was performed. A total of 62 patients were identified, with 31 in each group. Parameters were compared to evaluate postoperative outcomes using chi-squared tests, independent-samples t-tests, and z-tests of proportions analyses where applicable.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 19 - 19
1 Apr 2014
Yoon W Panagiotidou A Noordeen H Blunn G
Full Access

Aim:

The aim of this study was test the amount of corrosion occurring at the (Ti) /cobalt chrome (CoCr) interface comparing this with Ti and Ti interfaces. This was compared with retrieved metal work visualised under a scanning electron microscope (SEM).

Methods:

The interface of interest is the interface between rod and the screw. We investigated corrosion seen at that interface with a CoCr rod coupled to a Ti screw versus a Ti rod coupled to a Ti screw (6 screws were used) Implants were loaded according to the ASTM F2193 – 02 Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System. Pitting potentials were monitored using cyclic potentiodynamic polarization tests (ASTM F2129 – 08 Standard Test Method for Conducting Cyclic Potentiodynamic Polarisation Measurements) to determine corrosion susceptibility. Retrieved implants were visualised under (SEM) to confirm corrosion.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 15 - 15
1 Apr 2014
Lukina E Blunn G Kollero M Meswania J Mason P Wagstaff P Laka A Noordeen H Yoon W
Full Access

Introduction:

Due to absence of fusion in guided-growth devices for EOS (growing rods, Shilla, LSZ) movement of the rods against their attachment is possible resulting in wear debris formation. It is important to understand the wear resistance of materials used in these devices under appropriate conditions.

Aim:

The aim of our work was to investigate wear resistance of titanium alloy Ti-6Al-4V and superelastic Nitinol. Nitinol has been used recently for correcting scoliosis and may provide a better and more gradual correction than other materials.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 75 - 80
1 Jan 2013
Dannawi Z Altaf F Harshavardhana NS El Sebaie H Noordeen H

Conventional growing rods are the most commonly used distraction-based devices in the treatment of progressive early-onset scoliosis. This technique requires repeated lengthenings with the patient anaesthetised in the operating theatre. We describe the outcomes and complications of using a non-invasive magnetically controlled growing rod (MCGR) in children with early-onset scoliosis. Lengthening is performed on an outpatient basis using an external remote control with the patient awake.

Between November 2009 and March 2011, 34 children with a mean age of eight years (5 to 12) underwent treatment. The mean length of follow-up was 15 months (12 to 18). In total, 22 children were treated with dual rod constructs and 12 with a single rod. The mean number of distractions per patient was 4.8 (3 to 6). The mean pre-operative Cobb angle was 69° (46° to 108°); this was corrected to a mean 47° (28° to 91°) post-operatively. The mean Cobb angle at final review was 41° (27° to 86°). The mean pre-operative distance from T1 to S1 was 304 mm (243 to 380) and increased to 335 mm (253 to 400) in the immediate post-operative period. At final review the mean distance from T1 to S1 had increased to 348 mm (260 to 420).

Two patients developed a superficial wound infection and a further two patients in the single rod group developed a loss of distraction. In the dual rod group, one patient had pull-out of a hook and one developed prominent metalwork. Two patients had a rod breakage; one patient in the single rod group and one patient in the dual rod group. Our early results show that the MCGR is safe and effective in the treatment of progressive early-onset scoliosis with the avoidance of repeated surgical lengthenings.

Cite this article: Bone Joint J 2013;95-B:75–80.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 14 - 14
1 Jul 2012
Dannawi Z El-Sebaie HB Akbarnia BA Noordeen H
Full Access

Purpose

The aim of this study is to assess the safety and efficacy of a remote-operated magnetic growth rod in the treatment of 11 patients with progressive early onset scoliosis (EOS).

Introduction

The Growth rod technique (GR) has been a viable treatment option for progressive early onset scoliosis (EOS). However, an increased complication rate has been associated with conventional GR due to frequent surgeries required for lengthening. The safety and efficacy of a remote-operated magnetic growth rod (RO-MGR) has been previously reported in a porcine model. We are reporting the preliminary clinical results of this device which obviates the need for repeated surgeries.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 7 - 7
1 Jul 2012
Dannawi Z Al-Mukhtar M Leong JJH Shaw M Gibson A Elsebaie HB Noordeen H
Full Access

Purpose of the study

We propose a simple classification for adolescent idiopathic scoliosis (AIS) based on two components which include the curve type and shoulder level and suggest a treatment algorithm for AIS.

Introduction

Few Classification systems for adolescent idiopathic scoliosis (AIS) have helped in communicating, understanding and selecting a treatment for this condition; however, most of these classifications are complex and include many subtypes, making it difficult for the orthopaedic surgeon to use them in clinical practice. The variable reliability and reproducibility of these studies make recommendations and comparisons between various operative treatments a difficult task. Furthermore, none of these classifications has taken the shoulder imbalance into account, despite its importance as a clinical parameter and outcome measure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 12 - 12
1 Jun 2012
Noordeen H Shah S Elsebaie H Garrido E Farooq N Mukhtar M
Full Access

Introduction

Growing rods are used in the treatment of early-onset scoliosis. The aim of this technique is to achieve deformity correction while maintaining spinal growth. Gradual stiffening or spontaneous fusion of the spine can interfere with the ability to lengthen. Furthermore, diminished acquired length with serial distraction is common and needs to be evaluated and quantified. The purpose of this prospective study was to measure the forces and amount of distraction over time in patients with early-onset scoliosis treated with growing rods.

Methods

Distraction forces were measured prospectively during 60 consecutive lengthening procedures in 26 patients. All patients had single submuscular rod constructs with side-to-side connectors. For every measurement, output from a transducer on a dedicated pair of distraction calipers was recorded at zero load status, and the force was then recorded at every 1 mm lengthening; length was obtained at each event and was recorded in millimeters.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 4 - 4
1 Jun 2012
Elsebaie H Noordeen H Akbarnia B Gadelhak A
Full Access

Introduction

There is an unresolved controversy in the published work about the effect of screws crossing the neuro-central cartilage (NCC) on spinal canal dimension in very young children and in animals. Anterior vertebral body screws with fusion can invade and damage the NCC, especially at the site of screw insertion; however, this finding has never been studied.

Methods

This study is a retrospective, clinical and radiological analysis of seven consecutive children aged 1–2 years treated with anterior vertebral instrumentation and fusion by downsized rod screw systems. The mean age at time of surgery was 2 years 4 months (range 1 year 9 months to 2 years 10 months). The average follow-up period was 3 years 3 months (2 years 6 months to 4 years 5 months). 16 screws inserted anteriorely were evaluated by a follow-up CT scan. Spinal canals were divided with known anatomical landmarks into right and left hemicanals. The relation of the anterior screws to the NCC and the spinal canal dimension were studied. All clinical and radiological complications were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 35 - 35
1 Jun 2012
Noordeen H Elsebaie H Akbarnia B
Full Access

Introduction

Surgical correction of spinal deformities is a challenge; segmental instrumentation controlling almost every level is the most recent approach. Correction of the deformity only through apical manipulation has many potential advantages, including little tissue disruption, less invasive intervention, preservation of spinal mobility, and vertebral growth. However, quantification of the amount of force needed to pull on the apex and its effect on translation, de-rotation, and overall correction of the curve needs to be studied. The purpose of this study is to determine the effect and amount of force needed to pull on the apex of a scoliotic deformity towards the midline, and the feasibility of use of this novel potential method of correction in the treatment of patients with adolescent idiopathic scoliosis (AIS).

Methods

Measurements were taken from 20 patients with AIS treated between June, 2009, and January, 2010. There were 16 female and 4 male patients with an average age of 14.2 years (range 11–20); the coronal preoperative Cobb angle was 67° (42–108°), decreasing on bending to 39° (8–83°), and the apex of the deformity was between T6 and L2. All patients had proximal and distal anchors spanning two levels on each end; the anchors were connected by a concave rod to which the apical vertebra was pulled. We measured the distance between the rod and the apical vertebra and the rotation of the apical vertebrae.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 7 - 7
1 Jun 2012
Elsebaie H Noordeen H Akbarnia B Gadelhak A
Full Access

Introduction

The change of position of the distal pedicle screws with growing rods in relation to vertebral bodies was described as pedicle screws migration. Pedicle screws are subjected to serial distractive forces pushing them down with every distraction; additionally there is continuous growth of the vertebral bodies during the treatment period. These two factors can affect the change of position of the pedicle screws in relation to the vertebrae during the use of growing rods. To our knowledge, this finding has never been studied, confirmed, or quantified.

Methods

This is a retrospective review of the radiographs and operative notes of 23 consecutive cases of early-onset scoliosis treated with single growing rods. Age at index surgery ranged from 4 years 2 months to 8 years 9 months, and the number of distractions was four to 11 per patient. Measurements were done on post-index and latest follow-up true lateral radiographs. With optimum initial position of the screws in the pedicle, we calculated the distance between the upper end plate and the pedicle screw (distance superior to the screw [SS]) and the distance between the screw and lower-end plate (distance inferior to the screw [IS]). We expressed this ratio as a percentage: SS/IS x 100%. Any increase in this percentage with time denoted a more caudal position; however, a change in the percentage of less than 10% was regarded as insignificant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XX | Pages 12 - 12
1 May 2012
Altaf F Osei N Garrido E Al-mukhtar M Natali C Sivaraman A Noordeen H
Full Access

We describe the results of a prospective case series to evaluate a technique of direct pars repair stabilised with a construct that consists of a pair of pedicle screws connected with a u-shaped modular link that passes beneath the spinous process. Tightening the link to the screws compresses the bone grafted pars defect providing rigid intrasegmental fixation. 20 patients aged between 9 and 21 years with a pars defect at L5 confirmed on computed tomography (CT) were included. The average age of the patients was 13.9 years. The eligible patient had Grade I or less spondylolisthesis and no evidence of intervertebral degeneration on MRI. The average duration of follow-up was 4 years. Clinical assessments for all patients was via the Oswestry disability index (ODI) and visual analogue scores (VAS). At the latest follow-up, 18 of the 20 patients had excellent clinical outcomes with a significant (p<0.001) improvement in their ODI and VAS scores with a mean post-operative ODI score of 8%. Fusion of the pars defect as assessed by CT showed fusion rates of 80%. There were no hardware complications. The strength of the construct obviates the need for post-operative immobilisation.