Advertisement for orthosearch.org.uk
Results 1 - 20 of 39
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 43 - 43
19 Aug 2024
Lustig S Batailler C
Full Access

The stem design in total hip arthroplasty (THA) is constantly evolving. The impact of the collar on the risk of periprosthetic fracture remains controversial. This study aimed to determine whether adding a collar to the femoral stem impacts the early periprosthetic fracture risk within 90 days of surgery.

This retrospective study included 1,623 patients who underwent primary total hip arthroplasty in a single orthopedic department between January 2010 and December 2020. The inclusion criteria were uncemented stem with or without a collar, in a primary intention, without previous hip surgery with a similar “corail like” design. The assessed data were demographic characteristics (age, gender, number of obese (BMI > 30)), single or dual mobility, the surgical approach, the early complication, particularly the periprosthetic femoral fractures. Of the 1,623 patients, 1,380 received a collared stem (85%), and 243 received a collarless stem (15%). A multivariate analysis was performed to determine the collar's effect on the risk of early periprosthetic fracture (<90 days).

Nine (0.55%) early periprosthetic fractures were identified in the whole cohort. There were four fractures (1.65%) in the collarless stem group and five fractures (0.36%) in the collared stem group (p=0,005). One patient required revision surgery in the collared stem group, while two patients required revision surgery in the collarless stem group. The multinomial logistic regression model indicated a statistically significant lower (p<0.05) risk of early periprosthetic fracture within 90 days of surgery in the collared stems group. No other risk factor for early periprosthetic fractures has been identified.

Using collared stems in cementless THA protects early periprosthetic femoral fractures within 90 days of surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 81 - 88
1 Mar 2024
Lustig S Cotte M Foissey C Asirvatham RD Servien E Batailler C

Aims

The benefit of a dual-mobility acetabular component (DMC) for primary total hip arthroplasties (THAs) is controversial. This study aimed to compare the dislocation and complication rates when using a DMC compared to single-mobility (SM) acetabular component in primary elective THA using data collected at a single centre, and compare the revision rates and survival outcomes in these two groups.

Methods

Between 2010 and 2019, 2,075 primary THAs using either a cementless DM or SM acetabular component were included. Indications for DMC were patients aged older than 70 years or with high risk of dislocation. All other patients received a SM acetabular component. Exclusion criteria were cemented implants, patients treated for femoral neck fracture, and follow-up of less than one year. In total, 1,940 THAs were analyzed: 1,149 DMC (59.2%) and 791 SM (40.8%). The mean age was 73 years (SD 9.2) in the DMC group and 57 years (SD 12) in the SM group. Complications and revisions have been analyzed retrospectively.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims

Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure.

Methods

Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m2 (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 953 - 960
1 Sep 2023
Cance N Erard J Shatrov J Fournier G Gunst S Martin GL Lustig S Servien E

Aims

The aim of this study was to evaluate the association between chondral injury and interval from anterior cruciate ligament (ACL) tear to surgical reconstruction (ACLr).

Methods

Between January 2012 and January 2022, 1,840 consecutive ACLrs were performed and included in a single-centre retrospective cohort. Exclusion criteria were partial tears, multiligament knee injuries, prior ipsilateral knee surgery, concomitant unicompartmental knee arthroplasty or high tibial osteotomy, ACL agenesis, and unknown date of tear. A total of 1,317 patients were included in the final analysis, with a median age of 29 years (interquartile range (IQR) 23 to 38). The median preoperative Tegner Activity Score (TAS) was 6 (IQR 6 to 7). Patients were categorized into four groups according to the delay to ACLr: < three months (427; 32%), three to six months (388; 29%), > six to 12 months (248; 19%), and > 12 months (254; 19%). Chondral injury was assessed during arthroscopy using the International Cartilage Regeneration and Joint Preservation Society classification, and its association with delay to ACLr was analyzed using multivariable analysis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 42 - 42
23 Jun 2023
Lustig S Cotte M Foissey C Asirvatham R Servien E Batailler C
Full Access

The benefit of dual mobility cup (DMC) for primary total hip arthroplasties (THA) is still controversial. This study aimed to compare 1) the complications rate, 2) the revisions rate, 3) the survival rate after monobloc DMC compared to large femoral heads (LFH) in primary THA.

Between 2010 and 2019, 2,075 primary THA using cementless DMC or LFH were included. Indications for DMC were patients older than 70 years old or with high risk of dislocation. Every other patient received a LFH. Exclusion criteria were cemented implants, femoral neck fracture, a follow-up of less than one year. 1,940 THA were analyzed: 1,149 DMC (59.2%), 791 LFH (40.8%). The mean age was 73 ±9.2 years old in DMC group and 57 ±12 in LFH group. The complications and the revisions have been assessed retrospectively.

The mean follow-up was 41.9 months ±14 [12–134]. There were significantly fewer dislocations in DMC group (n=2; 0.17%) compared to LFH group (n=8; 1%) (p=0.019). The femoral head size had no impact on the dislocations rate in LFH group (p=0.70). The overall complication rate in DMC (n=59; 5.1%) and LFH (n=53; 6.7%) were not statistically different (p=0.21). No specific complication was attributed to the DMC. In DMC group, 18 THA (1.6%) were revised versus 15 THA in LFH group (1.9%) (p= 0.71). There was no statistical difference for any cause of revisions in both groups. The cup aseptic revision-free survival rates at 5 years were 98% in DMC group and 97.3% in LFH group (p=0.78).

Monobloc DMC had a lower risk of dislocation in a high-risk population than LFH in a low-risk population at the mid-term follow-up. There was no significant risk of specific complications or revisions for DMC in a large cohort. Monobloc DMC can be safely used in a selected high-risk population.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims

The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients.

Methods

All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m2 (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle).


Aims

The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group).

Methods

This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 33 - 33
1 Oct 2022
Ferry T Kolenda C Briot T Craighero F Conrad A Lustig S Bataillers C Laurent F
Full Access

Background

Bacteriophages are natural viruses of interest in the field of PJI. A paper previously reported the PhagoDAIR procedure (use of phages during DAIR) in three patients with PJI for whom explantation was not desirable. As the need to isolate the pathogen before surgery to perform phage susceptibility testing is a strong hindrance for the development of this procedure, we developed post-operative phage injections using ultrasound, in patients infected with S. aureus and/or P. aeruginosa who were eligible for the PhagoDAIR procedure, but for whom phages were not available at the time of surgery.

Materials/Methods

We performed a single center, exploratory, prospective cohort study including patients with knee PJI who received phage therapy with ultrasound after performance of a DAIR or a partial prosthesis exchange. All patients had PJI requiring conservative surgery and suppressive antimicrobial therapy (SAT) as salvage procedure. Each case was discussed in multidisciplinary meetings in agreement with French health authority, based on the clinical presentation, and the phage susceptibility testing. The cocktail of highly concentrate active phages (5 mL; about 10e9 PFU/mL) was extemporaneous prepared and administered three times directly into the joint using sonography (1 injection per week during 3 weeks) during the postoperative period, before switching antibiotics to SAT.


Background

Exebacase, an antistaphylococcal lysin in Phase 3 of development as a treatment for S. aureus bacteremia/right-sided endocarditis has demonstrated antibiofilm activity in vitro and has previously been used as salvage therapy in four patients with relapsing multidrug-resistant (MDR) S. epidermidis knee prosthetic joint infection (PJI) using a procedure called LysinDAIR (administration of the lysin during the performance of an arthroscopic DAIR).

Materials/methods

We performed a single center, exploratory, open-label prospective study using the LysinDAIR procedure in patients with chronic (inoculation >3 months prior to treatment) coagulase-negative staphylococci (CNS) PJI of the knee with two different clinical presentations and treatment paradigms. Cohort A: first episode of CNS knee PJI, for whom the LysinDAIR was followed by clindamycin + levofloxacin planned to be prescribed for three months and then stopped; and Cohort B: relapsing episodes of MDR CNS knee PJI for whom the LysinDAIR was followed by primary antimicrobial therapy for three months, followed by suppressive antimicrobial therapy (SAT). Exebacae susceptibility testing was performed before treatment for each patient. In agreement with the French Health authority, exebacase (2 to 3.5 total mg in 30–50 ml (∼0.067 – 0.075 mg/m) was administered directly into the joint during arthroscopy.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 383 - 389
1 May 2022
Motesharei A Batailler C De Massari D Vincent G Chen AF Lustig S

Aims

No predictive model has been published to forecast operating time for total knee arthroplasty (TKA). The aims of this study were to design and validate a predictive model to estimate operating time for robotic-assisted TKA based on demographic data, and evaluate the added predictive power of CT scan-based predictors and their impact on the accuracy of the predictive model.

Methods

A retrospective study was conducted on 1,061 TKAs performed from January 2016 to December 2019 with an image-based robotic-assisted system. Demographic data included age, sex, height, and weight. The femoral and tibial mechanical axis and the osteophyte volume were calculated from CT scans. These inputs were used to develop a predictive model aimed to predict operating time based on demographic data only, and demographic and 3D patient anatomy data.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 9 - 9
1 Dec 2021
Ferry T Conrad A Senneville E Roux S Dupieux-Chabert C Dinh A Lustig S Goutelle S Briot T Pham T Valour F
Full Access

Aim

Tedizolid is an oxazolidinone antibiotic that: (i) is recommended at the dose of 200 once daily in patients with skin and soft tissue infection; (ii) seems to have a better long-term hematological and neurological safety profile in comparison with linezolid; (iii) remains active on multidrug-resistant (MDR) Gram-positive pathogens. Consequently, it might represent an option as suppressive antimicrobial treatment (SAT) in patients with complex implant-associated bone and joint infection (BJI) due to MDR Gram-positive pathogens.

Method

We performed a cohort study (2017–2020) to evaluate the long-term safety of tedizolid (200mg qd) as SAT in patients with implant-associated BJI. In all cases, the use of tedizolid was validated as the last oral treatment option during multidisciplinar meetings in a reference center for the management of BJI. Serious adverse events, any reason for discontinuation, and standard biological data, were prospectively collected.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 78 - 78
1 Dec 2021
Benech N LEVAST B Gasc C Cecile B Senneville E Lustig S Boutoille D Dauchy F Zeller V Cazanave C Josse J Laurent F Ferry T
Full Access

Aim

Bone and joint infections (BJI) need frequently prolonged antibiotic treatment at high dosage for a total of 6 or 12 weeks depending the type of infection. Impact of such prolonged antibiotic exposure on the gut microbiota has never been assessed.

Method

We performed a national multicentric prospective study of patients with BJI to monitor the gut microbiota dynamic all along antimicrobial treatment. Clinical data and stool collection were performed at the baseline visit (B) within 24h before starting antibiotics, at the end of the treatment (EOT) and 2 weeks after antibiotic withdrawal during a follow-up visit (FU). Microbiota composition was determined by shotgun metagenomic sequencing. Biological markers of gut permeability and inflammation were monitored at each time point.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 127 - 127
1 Nov 2021
Batailler C Lording T Naaim A Servien E Cheze L Lustig S
Full Access

Introduction and Objective

In recent studies, robotic-assisted surgical techniques for unicompartmental knee arthroplasty (UKA) have demonstrated superior implant positioning and limb alignment compared to a conventional technique. However, the impact of the robotic-assisted technique on clinical and functional outcomes is less clear. The aim of this study was to compare the gait parameters of UKA performed with conventional and image-free robotic-assisted techniques.

Materials and Methods

This prospective, single center study included 66 medial UKA, randomized to a robotic-assisted (n=33) or conventional technique (n=33). Gait analysis was performed on a treadmill at 6 months to identify changes in gait characteristics (walking speed, each degree-of-freedom: flexion–extension, abduction–adduction, internal-external rotation and anterior-posterior displacement). Clinical results were assessed at 6 months using the IKS score and the Forgotten Joint Score. Implants position was assessed on post-operative radiographs.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 610 - 618
1 Apr 2021
Batailler C Bordes M Lording T Nigues A Servien E Calliess T Lustig S

Aims

Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted techniques versus a conventional surgical technique.

Methods

Three groups of 93 medial UKAs were assessed. The first group was performed by a conventional technique, the second group with an image-free robotic-assisted system (Image-Free group), and the last group with an image-based robotic arm-assisted system, using a preoperative CT scan (Image-Based group). There were no demographic differences between groups. We compared six parameters on postoperative radiographs to assess UKA sizing. Incorrect sizing was defined by an over- or under-sizing greater than 3 mm.


Introduction

In prosthetic knee surgery, the axis of the lower limb is often determined only by static radiographic analysis. However, it is relevant to determine if this axis varies during walking, as this may alter the stresses on the implants. The aim of this study was to determine whether pre-operative measurement of the mechanical femorotibial axis (mFTA) varies between static and dynamic analysis in isolated medial femorotibial osteoarthritis.

Methods

Twenty patients scheduled for robotic-assisted medial unicompartmental knee arthroplasty (UKA) were included in this prospective study. We compared three measurements of the coronal femorotibial axis: in a static and weightbearing position (on long leg radiographs), in a dynamic but non-weightbearing position (intra-operative acquisition during robotic-assisted UKA), and in a dynamic and weightbearing position (during walking by a gait analysis).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 60 - 60
1 Feb 2021
Lustig S Batailler C Servien E Foissey C
Full Access

Introduction

Increasingly young and active patients are concerned about revision arthroplasty forcing the manufacturers to think about revision prostheses that fit to this population while meeting the indications and fitting with bone losses and ligament deficiencies. One of those industrials claims that its system allows the surgeon to rise the constraint from a posterior stabilized (PS) prostheses to a semi-constraint total stabilized (TS) prostheses without modifying the gait pattern thanks to a similar single radius design. The aim of the study was to compare gait parameters in patients receiving either PS or TS knee prostheses.

Methods

Nineteen patients in each groups were prospectively collected for this study and compared between each other. All subjects were assessed with a 3D knee kinematics analysis, performed with an optoelectronic knee assessment device (KneeKG®). Were measured for each knees range of motion (ROM) in flexion–extension, abduction–adduction, internal–external rotation and anterior–posterior displacement.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 27 - 27
1 Dec 2019
Triffault-Fillit C Eugenie M Karine C Becker A Evelyne B Michel T Goutelle S Fessy M Dupieux C Laurent F Lustig S Chidiac C Ferry T Valour F
Full Access

Aim

The use of piperacillin/tazobactam with vancomycin as empirical antimicrobial therapy (EAT) for prosthetic joint infection (PJI) has been associated with an increased risk of acute kidney injury (AKI), leading to propose cefepim as an alternative since 2017 in our reference center. The present study compared microbiological efficacy and tolerance of these two EAT strategies.

Method

All patients with PJI empirically treated by vancomycin-cefepim (n=90) were prospectively enrolled in an observational study, and compared with vancomycin-piperacillin/tazobactam-treated historical controls (n=117), regarding: i) the proportion efficacious empirical regimen (i.e., at least one of the two molecules active against the identified organism(s) based on in vitro susceptibility testing); and ii) the incidence of empirical therapy-related adverse events (AE), classified according to the Common terminology criteria for AE (CTCAE).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 26 - 26
1 Dec 2019
Kolenda C Josse J Medina M Fevre C Lustig S Ferry T Laurent F
Full Access

Aim

Staphylococcus aureus is the first causative agent of bone and joints infections (BJI). It causes difficult-to-treat infections because of its ability to form biofilms, and to be internalized and persist inside osteoblastic cells. Recently, phage therapy has emerged as a promising therapy to improve the management of chronic BJI. In the present study, we evaluated the efficacy of an assembly of three bacteriophages previously used in a clinical case report (Ferry, 2018) against S. aureus in in vitro models of biofilm and intracellular osteoblast infection.

Methods

Using HG001 S. aureus, the bactericidal activities of the assembly of the three bacteriophages (Pherecydes Pharma) used alone or in association with vancomycin or rifampicin were compared by quantifying the number of viable bacteria in mature biofilms and infected osteoblasts after 24h of exposure.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 4 - 4
1 Dec 2018
Becker A Triffault-Fillit C Forestier E Lesens O Cazorla C Descamps S Chidiac C Lustig S Montbarbon E Batailler C Boyer B Ferry T
Full Access

Aim

S. aureus and coagulase-negative staphylococci are the most frequent bacteria responsible for PJI. In patients with acute PJI (i.e. <1 month following the implantation), DAIR with exchange of removal components followed by a combination of antibiotics that includes rifampin (particularly rifampin+fluoroquinolone) are recommended. Unfortunately, some patients could not receive rifampin due to drug-drug interaction or stopped it due to an adverse event. Finally, it was unclear if the dose and the duration of rifampin influenced the prognosis.

Method

We performed a retrospective cohort study in 4 hospitals and included patients with staphylococcal acute post-operative (< 1 month) PJI treated with DAIR in 2011–2016 period. Univariate and multivariate Cox analysis and Kaplan Meier curves were used to determine the risk factors for treatment failure (persistence of clinical signs, new surgery w/o persistence or superinfection, infection-related death).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 68 - 68
1 Dec 2018
Abad L Diot A Josse J Tasse J Lustig S Ferry T Laurent F Valour F
Full Access

Aim

Leading etiology of Bone and Join infections (BJI), Staphylococcus aureus (SA) is responsible for difficult-to-treat infections mainly because of three persistence factors: (i) biofilm formation, (ii) persistence within bone cells and (iii) switch to the small colony variant (SCV) phenotype. The impact of rifampin on these mechanisms gave it a prominent place in orthopedic device-associated BJI. However, resistance emergence, intolerance and drug interactions cause significant concerns. In this context, other rifamycins – namely rifapentine and rifabutin – have poorly been evaluated, particularly toward their ability to eradicate biofilm-embedded and intracellular reservoirs of SA.

Method

This study aimed at comparing the intracellular activities of and SCV induction by rifampin, rifabutin and rifapentine in an in vitro model of osteoblast infection. Four concentrations were tested (0.1xMIC, MIC, 10xMIC, 100xMIC) against three SA strains (6850 and two clinical isolates involved in recurrent BJI)