In early secondary arthritis due to femoral dysplasia, varus osteotomy achieves a control of arthritis for two decades in 80 % of cases : it is therefore a very reliable conservative treatment. Moreover, in carefully selected cases of severe arthritis in young active patients, a valgus osteotomy can achieve pain relief for a decade in 70 % of cases.
A – 1) Four factors are mandatory to achieve long term improvement:
The arthritis must be the There must be a real The articular The possibility of articular 2) Therefore varus osteotomy is
in a non symptomatic dysplasia (as some of them may not lead to arthritis), or if the symptoms are those of a labrum syndrom, with suddent pain, instead of a progressive and mechanical arthritic pain. if the dysplasia is only acetabular : then only the acetabulum has to be treated. if the anatomic abnormality is not an increase of the inclinaison (neck-shaft) angle, but a modification of the head-neck angle, which causes impigement with the labrum, and which is not improved by inter-tro-chanteric osteotomy. 3) The
If there is a femoral hyperanteversion there are two different conditions in the adult : if the patient walks with internal rotation of knees (convergent strabismus of patella), realising a dynamic correction of hyperanteversion, the association an external rotation of the femur to the varisation is recommended. but if, despite hyperanteversion, walking is without abnormal rotations of the knees, this means that the optimum congruity of the hip is in that position. An ostotomy is no advocated as, instead of retroversing the femoral neck, it would rotate externally the femoral shaft. If there are both an acetabular and a femoral dysplasia, they both have to be treated : if an augmentation is recommended for an anterolateral defect, the shelf osteoplasty can be performed in the same operation that the varus osteotomy. if a medialisation is necessary (Chiari), both osteotomies can be assosciated in one stage. but if a complex reorientation osteotomy is necessary (either periacetabular –Giacometti-, or pelvic –Ganz-), it could be hazardous to perform a varus osteotomy at the same time. B –
The importance of the varisation depends on that of the coxa valga. The final inclinaison angle must be 125°, as the lever of arm of the abductors is impaired for a lower angle. Moreover there is a post operative limping due to the ajustement of the glutei length, the duration of which is function of the varisation (one year per 10°). To reduce this limping, only the necessary varisation has to be made. The technic has several important points : non union is avoided by non dissection of the medial metaphysis or removal of a wedge : we use a subperiosteal osteotomy, leaving in contact the medial cortex, with a lateral opening, fixed by a nail plate as a tension band. This technique gives a minimum limb shortening (12 mm for 15° varisation). respect of the articulation and soft tissues. There is no arthrotomy as the nail plate is inserted on a guide pin. Later implantation of the THR will not be complicated by the previous osteotomy. precise, « automatic » correction, depends only on the nailplate angle. the resistance of the osteosynthesis allows immediate rehabilitation (this extra articular operation does not reduce ROM), and 10 to 20 kilos weight bearing. Full weight bearing is authorized at three months. C – There are less thant 5 % mechanical complications. An antalgic effect is obtained within some weeks. In 80 % of cases, painlessness and absence of radiological deterioration for two decades is achieved, a THR becoming necessary in the third decade. In 20 % of cases, only a temporary effect is obtained, leading to a THR after 5 to 10 years.
The femoral varus osteotomy remains one of the most reliable conservative operations in osteoarthritis due to DDH. However to achieve these good results, a clear understanding of the indications and biomechanical demands of this operation is required. In seldom and selected cases of severe arthritis, a palliative valgus osteotomy can achieve a decade of pain relief.
For unstable fractures of the femoral shaft, the current interlocking nails are the most reliable fixation. However, these procedures require the use of an image amplifier for targeting the distal screws, and are expensive, ancillary instrumentation and an extensive stock of numerous nail sizes with various diameters, sides, and lengths is necessary. We report a consecutive series of 60 unstable femoral fractures treated with the Endolock nail. This closed 11 mm diameter nail is introduced after little or no reaming. Distal fixation is achieved by means of a spur that unfolds from the nail and fixes into the posterior metaphysis. Radiological control during the procedure is recommended but not mandatory. Fusion was achieved in all cases but three (5%). Two were aseptic in the same patient who presented two upper limb non-unions, and one with infection (little or no reaming was used in the nine open fractures). Eight moderate mal-unions were observed (angulation <
10°, external rotation <
20°, shortening <
20 mm) but did not require re-operation. All of these were the consequence of insufficient reduction of the fractures. No secondary displacement occurred between operation and fusion. No complications related to spur penetration or removal were observed. The Endolock nail allows satisfactory interlocking without the mandatory use of an image amplifier, with little or no reaming, and at a low cost.