To compare 24-month patient-reported outcomes after surgical treatment or casting in patients age 60 years of age or older with unstable distal radius fractures (DRF's). The Wrist and Radius Injury Surgical Trial (WRIST), is the largest randomized, multicenter trial in Hand Surgery, which enrolled 304 adults with isolated, unstable DRF's at 24 institutions. WRIST participants were followed for 24 months- longest follow-up among prospective studies comparing four treatment methods. Patients who agreed to surgical treatment (n=187) were randomized to internal fixation with volar plate (VLPS), external fixation, or percutaneous pinning; patients who preferred conservative management (n=117) received casting. The primary outcome was 24-month Michigan Hand Outcomes Questionnaire (MHQ) Summary score. Secondary outcomes were MHQ Domain scores. At 24-month assessment, participants' mean MHQ Summary score was 86 (95% CI: 83,88), representing good hand function. Participants reported good return of their Activities of Daily Living (ADLs) with a mean MHQ ADL score of 88 (95% CI: 85,91). Finally, participants were satisfied, with a mean MHQ Satisfaction score of 84 (95% CI: 80,88). There were no significant differences in score by treatment group in any MHQ domain at 24 months. Six weeks after surgery, VLPS participants scored significantly higher than the other three groups on (ADLs) and Satisfaction (both p<0.0001), whereas participants who received external fixation scored significantly lower than the casting and VLPS groups on the same domains. By the 3-month assessment, the gap between VLPS and casting had disappeared but external fixation participants continued to report significantly worse scores. External fixation participants did not report comparable ADL scores to the other three groups until 12 months after surgery. Participants reported good outcomes 24 months after DRF regardless of treatment. Casting and VLPS are both acceptable treatments for older adults. The decision between the two treatments should be made considering patient goals regarding recovery speed and desire to avoid surgical risks. External fixation should be avoided because of worse outcomes in the year after surgery and the risk of pin site infections.
Isolated liner and head exchange procedure has been an established treatment method for polyethylene wear and osteolysis when the acetabular component remains well-fixed. In this study, its mid-term results were evaluated retrospectively in 34 hips. Among the consecutive patients operated upon from September 1995, 2 patients (3 hips) were excluded because of inadequate follow-up and the results of remaining 34 hips of 34 patients were evaluated. They were 20 men and 14 women with a mean age of 49 years at the time of index surgery. Conventional polyethylene liner was used in 26 cases and highly cross-linked polyethylene liner was used in 8 cases. In 3 cases, liner was cemented in the metal shell because compatible liner could not be used. After a minimum follow-up of 5 years (range, 5∼20.2), re-revision surgery was necessary in 10 cases (29.4%); 8 for wear and osteolysis, 2 for acetabular loosening. In all re-revision cases, conventional polyethylene was used. There was no failure in the cases in which highly cross-linked polyethylene was used. There was no case complicated with dislocation. The results of this study suggest more promising results with the use of highly cross-linked polyethylene in isolated liner exchange.
Recent clinical studies have suggested that systemic metal ion levels are significantly elevated at midterm follow-up after ceramic-on-metal (COM) bearing. However, it is not clear whether there is a correlation between patient- and surgical-related factors including the lifestyle and elevated levels of serum metal ions following COM total hip arthroplsty (THA). Two hundred and one patients (234 hips) including 121 COM patients (140 hips) and 80 non-COM patients (94 hips) were enrolled in accordance with the inclusion criteria. The patients were divided into three groups based on the type of surgical bearings used. The Harris Hip Score (HHS), University of California, Los Angeles (UCLA) activity scale score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score were measured, and radiographs were obtained for the analysis. Serum metal ion levels of cobalt and chromium were measured using a high-resolution inductively coupled plasma mass spectrometry. Patient- and surgical-related factors were analyzed to determine which group of patients is at a high risk of metal ion-related problems.Background
Material and Methods
The purpose was to compare the accuracy of the method using 3D printing model with the method using picture archiving and communication system (PACS) images in high tibial osteotomy (HTO). This study analyzed 40 patients with varus deformity and medial osteoarthritis. From 2012 to 2016, patients underwent HTO using either 3D printing model (20 knees) or method based on a PACS image (20 knees). After obtaining the correction angle for the target point (62.5% point of the mediolateral tibial plateau width), in the 3D printing method, the wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The PACS method used preoperative radiographs to shift the weight bearing axis. The accuracy of the HTO and the proportion of acceptable range (62.5 ± 5%) at each method was compared using the full-length lower limb radiographs at the sixth postoperative week. The pre and postoperative posterior tibial slope angle was also compared at each method.Purpose
Materials and methods
Although total hip arthroplasty is highly successful for treatment of osteoarthrosis of hip joint, it is skill demanding surgery to perform and even more challenging in case of revision with bone defects. There are many options available for reconstruction of acetabular bony defects. Here, we evaluate the outcome of acetabular bony defect reconstructed with trabecular metal augments in short term. We performed, 22 revision total hip arthroplasties and 6 primary total hip arthroplasties (total 28 in 28 patients) using trabecular metal augments to reconstruct acetabular defect between 2011 to 2015. Out of these 28 patients, 18 were males and 10 were females. Mean age of these patients was 61.2 years (range: 46 years to 79 years). Pre-operative templating was done for all cases and need for trabecular metal augments was anticipated in all cases. All cases were classified according to Paprosky classification for acetabular bone defects. Out of 28 patients, 3 had type 2B, 1 had type 2C, 18 had type 3A and 6 had type 3B acetabular defects. Post operatively, all patients were followed at regular interval for their clinical and radiological outcome. An average follow up was 20.1 months (range: 6 months to 42.5 months). We assessed clinical outcome in the form of Herris hip score (HHS) and radiological outcomes in form of osteolysis in acetabular zones and osseointegration, according to the criteria of Moore. The average Harris hip score (HHS) was improved from 58.0 preoperatively to 87.2 postoperatively. The average degree of cup abduction at the final follow up was 44.29. The centre of rotation of the hip joint was corrected from average 38.90mm (range: 22.15mm to 66.35mm) above the inter-teardrop line preoperatively to average 23.85mm (range: 11.82mm to 37.69mm) above the inter-teardrop line postoperatively. Out of 28 patients, 18 patients had three or more signs of osseointegration, according to the criteria of Moore, at the time of final follow up. Rest of patients, had one or two signs of osseointegration (5 patients had one sign and 5 patients had two signs). We had no patient with migration or loosening of acetabular components. No patient has osteolysis of acetabulum in any zone. Trabecular metal augments provide good initial stability to acetabular cup as well as helpful to bring down the centre of rotation of the hip joint within limit of 35mm above the inter-teardrop line. They also facilitate osseointegration. Our study showed that the results of the trabecular metal augments in reconstruction of acetabular bony defects were successful even in short term. However, long term study is required for better evaluation.
Clinical and radiological results of total hip arthroplasty (THA) using proximally coated single wedge (PSW) cementless stems are generally excellent. The geometry of cementless stems and the morphology of proximal femurs (Dorr types) provide optimal fit for primary stability and secondary biologic fixation. Because the geometry of PSW shape is designed to be engaged at the metaphysis, cementless PSW stem is not traditionally recommended to Dorr type C femurs with concerns of inadequate implant-host bone contact and the risk of femoral fracture. Nevertheless, previous studies on PSW cementless stems have not examined long-term survivorship according to Dorr types of femur. Paucity of a long-term comparative study makes it difficult to know whether the PSW stem plays a role in Dorr type C femurs or not. We postulated that the PSW stem could achieve stable fixation without increased risk of femoral fracture even in Dorr type C femurs, and demonstrate acceptable long-term results. The aim of this study was to investigate differences of clinical and radiological outcomes of THA using PSW stem according to proximal femoral geometry (Dorr types) in more than a 10-year follow-up. Three hundred and seven primary THA in 247 patients, which was performed with use of a single-designed PSW stem from 1997 to 2003 and was followed up for over 10 years, were included in this retrospective study. According to Dorr's criteria, 89 femora were classified as Type A, 156 as Type B, and 62 as Type C. The patients' mean age at operation was 43.2 years (range, 18.4 – 69.6 years). They were followed-up for an average of 13.2 years (the range, 10.0 – 17.3 years). All of the hips were evaluated clinically and radiologically with special attention to the occurrence of implant loosening and periprosthetic femoral fracture. The mean preoperative Harris hip score (50.4±20.6 points) improved significantly to 95.6±9.0 points at the final follow-ups. The improvements were observed regardless of Dorr types (p<0.001 in all 3 groups). The incidence of thigh pain (p=0.704) was not significantly different among groups. Implant survivorship was 100% in all 3 groups. None of the stems were loosened or revised. No significant differences were observed in osteolysis (p=0.492), pedestal formation (p=0.323), or cortical hypertrophy (p=0.169) among the groups [Fig. 1]. Radiolucent lines less than 2mm in thickness in Gruen zone 4 were observed more in Dorr type C femora than in Dorr type A or B (p=0.003) [Fig. 2]. Spot weld (p<0.001) and stress shielding (p=0.010) of proximal femur were more pronounced in Dorr C type femora than in type A or B [Fig. 3]. The prevalence of intraoperative (p=0.550) or postoperative (p=0.600) femoral fractures were not significantly different among the groups. From over a 10-year follow-up, the PSW stem provided excellent stem survivorship regardless of Dorr type with satisfactory outcomes. The remodeling process around the stem was more pronounced in Dorr type C femur. The present study shows that the PSW stem is a recommendable option for Dorr type C femur.
Alternative bearing surfaces has been introduced to reduce wear debris-induced osteolysis after total hip arthroplasty (THA) and offered favorable results. Large population-based data for total joint surgery permit timely recognition of adverse results and prediction of events in the future. The purpose of this study was to present the epidemiology and national trends of bearing surface usage in primary total hip arthroplasty (THA) in Korea using nationwide database. A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital. The number of primary THAs increased by 25.2% from 5,484 in 2007 to 6,866 in 2011. The average age of the entire study population was 58.1 years, and 53.5% were male [Table 1]. CoC was the most commonly used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The distribution of bearing surfaces was identical to that in the general population regardless of age, gender, hospital type, and primary payer [Table 2]. The mean age of patients that received hard-on-hard bearing surfaces (CoC and MoM) was significantly younger than that of patients receiving hard-on-soft bearing surfaces (CoP and MoP) (56.9 years vs. 62.6 years). During the study period, 55.1% of THAs that used a hard-on-hard bearing surface were performed in males, while 53.0% of THAs that used a hard-on-soft bearing surface were performed in females. The order of prevalence of bearing surfaces was identical in low- and medium-volume hospitals (CoC was first, MoP was second, CoP was third, and MoM was fourth). The mean hospital charges did not differ according to the bearing surface used, with the exception of CoP, which was associated with a lower mean hospital charge. There were no changes in the distribution of bearing surfaces in each year between 2007 and 2011. Overall, the percentage of THAs that used CoC bearing surfaces increased substantially from 71.6% in 2007 to 81.4% in 2011, while the percentage that used CoP, MoP, and MoM decreased significantly [Fig. 1]. One of the reasons for the dominant usage of hard-on-hard bearing surfaces may be that the principal diagnosis of primary THAs and the patient age group distribution in Korea differ from those in other countries. The most common indication for primary THA is osteonecrosis of the femoral head in Korea. In contrast, the majority of primary THAs are performed for osteoarthritis in Western countries. The choice of bearing surface may be affected by many factors, including the nation's medical delivery system, payment type, disease pattern, and age distribution of patients that undergo THA. In future, the results of a large-scale nationwide study on primary THAs using CoC bearing surfaces in Korea will be reported.
A cell-based tissue-engineered construct can be employed for treating meniscal lesions occurring in the non-vascularized inner two-thirds. The objective of this study was to test the hypothesis that both pre-differentiation of human bone marrow derived stromal cells (hBMSCs) into chondrogenic lineage before cell seeding and platelet-rich plasma (PRP) pretreatment on a PLGA mesh scaffold enhances the healing capacity of the meniscus with hBMSCs-seeded scaffolds PRP of 5 donors was mixed and used for the experiments. The woven PLGA mesh scaffold (VicrylTM, Ethicon) measuring 20×8 mm (thickness, 0.2 mm) was prepared. The scaffolds were immersed into 1,000 μl of PRP and were centrifuged at 150g for 10 min. Then, the scaffold was flipped 180° and the same procedure was done for the other side. After washing, the scaffolds were soaked into 1,000 μl of DMEM media. hBMSCs from an iliac crest of 10 patients after informed consent and approval of our IRB were induced into chondrogenic differentiation with chondrogenic media containing 10 ng/ml rhTGF-ß3 in 1.2% alginate bead culture system for 7 days. Then, 2×105 hBMSCs were recovered, seeded onto the scaffold, and cultured under dynamic condition. Based on the presence of pre-differentiation into chondrogenic lineage and the PRP pretreatment, 4 study groups were prepared. (no differentiation without PRP, no differentiation with PRP, chondrogenic differentiation without PRP, chondrogenic differentiation with PRP) Cell number for each cell-seeded scaffold was determined at 24 hours after seeding. Then, scaffolds were placed between human meniscal discs and were implanted subcutaneously in nude mice for 6 weeks (n=10 per group).Background
Methods
Few epidemiological studies from Asian countries have addressed this issue and reported that FAI is less prevalent in Asian population. The purpose of this study was to determine the prevalence of radiographic hip abnormalities associated with FAI in asymptomatic Korean volunteers. The authors hypothesized that the prevalence of FAI in Korean population would not be less than that in western population. Two hundred asymptomatic volunteers with no prior hip surgery or childhood hip problems underwent three-view plain radiography (pelvis anteroposterior (AP) view, Sugioka view, and 45° Dunn view) of both hips. Cam lesions were defined as the presence of the following signs on each views: pistol-grip deformity, osseous bump at the femoral head-neck junction, flattening of the femoral head-neck offset, or alpha angle >50°. Pincer lesions were determined by radiographic signs, including crossover sign, posterior wall deficient sign, or lateral center-edge (CE) angle >40°. Only positive cases agreed by both observers were defined as true FAI-related deformities. There were 146 male and 254 female hips, with a mean age of 34.7 years. On pelvis AP view, the prevalence of pistol grip deformity, bump, flattening, and alpha angle >50° was 1.3% (male 3.4%, female 0%), 0.8% (male 2.1%, female 0%), 0.8% (male 2.1%, female 0%), and 1.0% (male 2.7%, female 0%), respectively. On Sugioka view, the prevalence of bump, flattening, and alpha angle >50° was 9.8% (male 14.4%, female 7.1%), 13.5% (male 20.5%, female 9.4%), and 14.0% (male 26.7%, female 6.7%), respectively. On 45° Dunn view, the prevalence of bump, flattening, and alpha angle >50° was 8.0% (male 14.4%, female 4.3%), 17.5% (male 27.4%, female 11.8%), and 27.5% (male 44.5%, female 17.7%), respectively. The prevalence of cam lesion which was identified on at least one radiograph was 42.5% (male 62.3%, female 31.1%). The prevalence of cam lesion which was identified on ≥2 radiographs was 19.3% (male 30.8%, female 12.6%). The prevalence of cam type FAI (at least one cam lesion) was 2.0% (male 5.5%, female 0%) on pelvis AP view, 25.8% (male 37.0%, female 19.3%) on Sugioka view, and 35.8% (male 55.5%, female 24.4%) on 45° Dunn view. On pelvis AP view, the prevalence of crossover sign, posterior wall sign, and CE angle >40° was 20.0% (male 23.3%, female 18.1%), 20.8% (male 22.6%, female 19.7%), and 2.0% (male 2.7%, female 1.6%), respectively. The prevalence of pincer type of FAI (at least one pincer lesion) was 23.0% (male 27.4%, female 20.5%). In asymptomatic Korean volunteers, the prevalence of cam type FAI was low on AP pelvis radiographs, whereas the prevalence of cam type FAI on Sugioka and 45° Dunn view was found to be comparable to that previously reported in Western populations. The prevalence of pincer type FAI in asymptomatic Korean volunteers was also comparable that in Western populations and was similar in both gender. Considering the high prevalence of FAI morphologic features on plain radiographs in asymptomatic Korean populations, it is also important to determine whether FAI is a cause of hip pain when considering surgery in Asian patients.
Legg-Calve-Perthes disease (LCPD), a juvenile osteonecrosis of the femoral head (ONFH), can remain sequelae around hip joint, and results in osteoarthritis necessitating total hip arthroplasty (THA) in middle-age. THA for sequelae of LCPD needs specific concerns for anatomical deformity, leg length discrepancy (LLD), and relatively young patient's age. To date, few studies are available for the results of THA for LCPD sequelae. Moreover, there was no study for the result of Alumina-Alumina THA (Al-Al THA) in patient with LCPD sequelae, even excellent long term outcome of Al-Al THA has been documented in relatively young patients. The aim of this retrospective study is to evaluate the clinical and radiological outcome of Al-Al THA for LCPD sequelae, especially in terms of the restoration of LLD and the occurrence of complication. In addition, we compared the results of THA for LCPD sequelae with those for adult onset ONFH, in which THA is necessitated in relatively young age and excellent long term outcome has been proven after Al-Al THA. Between 1997 and 2007, 41 cementless Al-Al THA were performed in 37 patients with LCPD sequelae and followed up for mean, 10.4 years. Mean age at THA was 43.6 years. Using the propensity score matching with age, gender, and the length of follow-up as variables, 41 THAs in 37 patients were identified from 339 hips in 256 patients who underwent primary Al-Al THA for ONFH during the same period. Clinical and radiological outcomes in terms of implant survival, Harris hip score (HHS), LLD change, and perioperative complication were compared between the two groups.Introduction
Method
Navigation systems that increase alignment accuracies of the lower limbs have been applied widely in total knee arthroplasty and are currently being adopted for minimally invasive UKA (MIS UKA) with good alignment results. There is little debate that when compared with total knee arthroplasty (TKA), UKA is less invasive, causes less morbidity, better reproduces kinematics, and therefore offers quicker recovery, better range of movement and more physiologic function. However, despite improved alignment accuracies, advantages of use of navigation system in UKA in clinical outcomes and survivals are still debatable. To the best of our knowledge, no reports are available on the long-term results after UKA performing using a navigation system. The purpose of this prospective study was to compare the radiological, clinical, and survival outcomes of UKA that performed using the navigation system and using the conventional technique at average 8 years follows up. Between January 2003 and December 2005, Total of 98 UKAs were enrolled for this study, 56 UKAs in the navigation group and 42 UKAs in conventional group were included in this study after a average 8 years follow-up. At the final follow up, the radiological measurements with regard to the mechanical axis, the inclination of the femoral and tibial components, and radiolucent line or loosening were evaluated and compared between two groups. The clinical evaluations were performed using range of motion, Western Ontario and McMaster Arthritis index (WOMAC) scores and Knee Society (KS) score.Background
Methods
Despite the excellent clinical success of total knee arthroplasty (TAK), controversy remains concerning whether or not to resurface the patella. This has led to a number of randomized controlled trials. Randomized controlled trials constitute the most reliable source of evidence for the evaluation of the efficacy of a potential intervention. But most of these studies include all degree of osteoarthritis of the patellofemoral joint. So we did this prospective study to compare clinical and radiological outcomes after TKA with or without patellar resurfacing in patients with grade IV osteoarthritis on patellofemoral joint. 123 cases (93 patients) with Kellgren-Lawrence grade IV osteoarthritis on patellofemoral joint were enrolled for this study. At the operating room, they were randomly assigned to undergo patella resurfacing (62 cases) or patella retention (61 cases). Among them, 114 cases that could be followed for more than 2 years were included in this study (resurfacing group; 59 cases, retention group; 55 cases). When patellar retention was performed, osteophytes of the patella were removed and marginal electrocauterization was carried out. Preoperative and postoperative clinical outcomes were evaluated and compared regarding the Hospital for Special Surgery Patellar (HSSP) score (total 100 point; anterior knee pain, functional limitation, tenderness, crepitus, Q-strength). We also compared Hospital for Special Surgery (HSS) and WOMAC scores, and range of motion (ROM). We also compared radiological outcomes at the final follow up, with regards to mechanical axis of the lower limb, patella tilt and patella congruence angle between two groups.Background
Materials and Methods
The most important factors affecting the outcome of a TKA are restoring the normal mechanical axis and achieving optimum soft tissue balance. In the measured resection technique may have accompanying problems in imbalanced patients. Secondly individual variability of the reference points may affect the alignment of the bony cuts and thereby the alignment of the implant. The gap balance technique blends the soft tissue balance with the bony cuts and tries to overcome this problem. However proponents of the measured resection technique argue that no consideration is given to the coronal and rotational alignment of the femoral component in the gap balance technique. The ligament specific navigation assisted gap balance technique, tries to overcome these fallacies. The lateral ligaments and soft tissues act as a reference against which the medial soft tissues are balanced. Thus the reference becomes individualized and any variability is taken care of. Navigation assistance ensures control of the coronal and rotational alignment of the femoral component. The aim of the present study was two fold: - To describe our methodology of ligament specific navigation assisted gap balance technique and analyze the clinico-radiological outcome of our technique over an eight year follow up. 79 patients (98 knees) with primary osteoarthritis with varus deformity and flexion deformity of were followed up for eight year duration. After obtaining an optimum gap balance and neutral axis in extension, tibial osteotomy perpendicular to the mechanical axis in both the coronal and sagittal planes was done. At this stage joint gaps were distracted in extension and 90â�° flexion. Based on the gap values patients were classified into three groups. Group 1 was the balanced group with flexion extension gap difference ≤2mm, group 2 was the flexion tight group with flexion gap smaller than the extension gap by ≥3mm and group 3 was the extension tight group with the extension gap smaller than the flexion gap by ≥3mm. Thereafter flexion gap balance was achieved only by adjusting the cutting levels of the distal and posterior condyles and adjusting the axial rotation of the femoral component without any further soft tissue release. Intraoperative navigation readings were recorded. All patients were followed clinico-radiologically at 1, 4, and 8 years post operatively.Background
Methods
The purpose of this study is to evaluate the midterm results of cementless revision total hip arthroplasty (THA) using Wagner Cone Prosthesis. Between 1996 and 2007, 36 hips in 36 consecutive patients underwent femoral revision THA using Wagner Cone Prosthesis. Among them 28 hips were followed for more than 5 years. The mean age at revision surgery was 57 years and a mean follow-up was 7.6 years. The Paprosky classification system was used for preoperative bone loss evaluation. Clinical results were evaluated using Harris hip scores. For evaluation of the femoral component, radiolucent lines at bone-implant interfaces were evaluated and femoral component vertical subsidence was measured. Heterotopic bone formation and complications were also evaluated.Purpose
Material and Methods
The purpose of this study was to evaluate the results of two stage reconstruction for infected arthroplasty of hip joint and to know the risk factor for failures. From May 2004 to September 2011, 104 consecutive patients (105 hips) who underwent two stage reconstruction for the infected arthroplasty of hip joint were retrospectively evaluated. There were 60 hips with primary THA infection (Acute infection 22, Delayed infection 38), 4 hips with revision THA infection (Acute infection 1, Delayed infection 3), 20 hips with primary hemiarthroplasty infection (Acute infection 14, Delayed infection 6) and 24 hips with acute pyogenic coxitis. We evaluated the number of surgeries before two-stage reconstruction and also analysed the cultured pathogens. Mean follow duration after 2nd stage revision THA was 1.80 ± 1.76 years and average age at the time of 1st stage surgery (Debridement and PROSTALAC insertion) was 62.8 ± 14.3 years.Purpose:
Patients and Methods: