Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

INCREASED SERUM ION LEVELS AFTER CERAMIC-ON-METAL BEARING TOTAL HIP ARTHROPLASTY: EFFECTS OF AN ASIAN LIFESTYLE

The International Society for Technology in Arthroplasty (ISTA), 30th Annual Congress, Seoul, South Korea, September 2017. Part 2 of 2.



Abstract

Background

Recent clinical studies have suggested that systemic metal ion levels are significantly elevated at midterm follow-up after ceramic-on-metal (COM) bearing. However, it is not clear whether there is a correlation between patient- and surgical-related factors including the lifestyle and elevated levels of serum metal ions following COM total hip arthroplsty (THA).

Material and Methods

Two hundred and one patients (234 hips) including 121 COM patients (140 hips) and 80 non-COM patients (94 hips) were enrolled in accordance with the inclusion criteria. The patients were divided into three groups based on the type of surgical bearings used. The Harris Hip Score (HHS), University of California, Los Angeles (UCLA) activity scale score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score were measured, and radiographs were obtained for the analysis. Serum metal ion levels of cobalt and chromium were measured using a high-resolution inductively coupled plasma mass spectrometry. Patient- and surgical-related factors were analyzed to determine which group of patients is at a high risk of metal ion-related problems.

Results

Significantly higher serum levels of Co and Cr were detected in the serum of the COM THA group (Co: 1.86±4.0 µg/L, range: 0.30 to 34.20 µg/L; Cr: 1.81±2.87 µg/L, range: 0.10 to 27.80 µg/L) than in the serum of the non-COM THA group (Co: 0.27±0.14 µg/L, range: 0.15 to 0.90 µg/L; Cr: 0.19±0.25 µg/L, range; 0.10 to 2.30 µg/L) (p<0.001).

The HHS in the COM group was significantly better than that in the non-COM group (p=0.013). The total ROM of the THAs was significantly greater in the 36-mm COM THA group (272.7°, range: 200°–345°) than in the non-COM group (248.5°, range: 135°–300°) (p<0.001). No radiolucency, osteolysis, or loosening was found during the follow-up radiographic examination.

The serum Co levels of patients who achieved the squatting position were significantly higher than those of patients who could not squat (Co: p=0.033; Cr: p=0.074). The serum Co and Cr levels of patients who achieved the kneeling position were significantly higher than those of patients who could not kneel (Co: p=0.049; Cr: p=0.031). There was no significant difference between the two groups in the cross-legged sitting position.

The metal ion levels of the COM THA group correlated with the total ROM (Co: p=0.0293; Cr: p=0.0399), and those of the patients who were capable of squatting and kneeling were significantly higher than those of the patients who were unable (p<0.05). However, age, BMI, acetabular cup position and patient activity did not show significant correlations with the serum metal ion levels.

Conclusions

Patients who underwent a 36-mm COM THA had good clinical outcomes with an excellent hip function at the short and midterm follow-up intervals. However, high levels of metal ions were detected in the serum of COM THA patients. We found that COM THA patients who were capable of greater ROMs, squatting, and kneeling are at risk of metal ion-related problems.


Email: