Introduction:

The risk for late periprosthetic fractures is higher in patients treated for a neck of femur fracture compared to those treated for osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated if a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite sawbone model.

Method:

A biomechanical composite sawbone model was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented stem were implanted by an experienced surgeon, in 7 sawbones each and loaded at 40 deg/s internal rotation until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874). Data are non-parametric and tested with Mann-Whitney U-test.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 436 - 436
1 Dec 2013
Morishima T Ginsel B Choy G Wilson L Whitehouse S Crawford R
Full Access

Introduction:

In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem.

Method:

A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 324 - 324
1 Dec 2013
Ginsel B Crawford R Whitehouse S Taher A
Full Access

Aim:

This prospective cohort study investigated whether the use of preoperative anticoagulants is an independent risk factor for the outcomes of surgical treatment of patients with a neck of femur fracture.

Methods:

Data was obtained from a prospectively collected database. All patients admitted for a neck of femur fracture between Nov 2010 and Oct 2011 were included. This resulted in three hundred twenty-eight patients with 330 neck of femur fractures. Four groups were defined; patients preoperatively (i) on aspirin (n = 105); (ii) on clopidogrel (n = 28); (iii) on warfarin (n = 30); and (iv) without any anticoagulation history (n = 167, the control group). The non-warfarin group included the aspirin group, clopidogrel group and the control group. Primary outcome was the in-hospital mortality. Secondary outcomes were the postoperative complications, return to theatre and length of stay.