Thirty-nine cementless hip replacements using metal-on-metal articulation were consecutively implanted in thirty patients less than fifty years of age and compared with a matched control group of cementless replacements using ceramic-on-polyethylene articulation. The Harris hip score at follow-up (minimum five years) for the metal-on-metal was 94.9 (range, 74–100). After the same follow-up, the results of the ceramic-on-polyethylene were significantly worse: nine osteolyses and seven surgical revisions related to wear. Five-year survival rates were 97% +/− 2% for the ceramic-on-polyethylene and 100% for the metal-on-metal. The metal-on-metal may be recommended to prevent wear problems in younger and more active patients. The aim of the current study was to assess the results of metal-on-metal articulating components inserted as a primary hip replacement in patients under the age of fifty, comparated with a matched control group using ceramic-on-polyethylene. Patients and methods The inclusion of patients was: under fifty years of age and a diagnosis of arthrosis or necrosis of the femoral head. Femoral stem and cup migration was detected. A variation over five millimeters between the follow-up radiographs was considered as migration. At the follow-up in 2003, the cobalt concentrations in the whole blood were assessed in the metal-on-metal cohort. The detection limit of cobalt in the whole blood was 0.06 μg/L. None of the components had migration. At a mean follow-up of sixty-nine months, the median concentration of cobalt in the whole blood was 0.62μg/L. Only eight patients had cobalt levels greater than 1 μg/L. Considering a reoperation with the exchange of one of the components as end point, the five year survival rates were 100% for the metal-on-metal group and 97% + 2 for the ceramic-on-polyethylene group. Our study suggests that the metal-on-metal articulation gives a significant improvement in terms of resistance to wear when compared with these conventional bearing components. Our results suggest the metal-on-metal articulation with cementless components can be recommended in the young and active patient to prevent the occurrence of wear and osteolysis. A careful assessment of patients with high levels of whole-blood cobalt should be performed. Funding: Aucun
We reviewed radiographs and CT scans of 38 total hip arthroplasties which had dislocated (36 posteriorly; 2 anteriorly) and compared the alignment of the prosthetic components with those of 14 uncomplicated arthroplasties. No difference was found between the alignment of the prosthetic components in the two groups. In the seven patients who had reoperations, the cause of dislocation diagnosed by CT was confirmed in only two cases (one retroversion of the cup and one protruding osteophyte). Muscular imbalance rather than malposition of the components was the major factor determining dislocation. CT allows accurate measurement of cup and neck anteversion but contributes little to preoperative planning.