Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 52 - 52
1 Sep 2012
Mahmood A Malal JG Majeed SA
Full Access

Aim. The purpose of the study was to evaluate the results of Expert tibial nailing for distal tibial fractures. Methods. All patients who had a distal third or distal end fracture of the tibia treated with the Expert tibial nail over a three year period at our institution were included in the study. A total of 44 distal tibial fractures in the same number of patients were treated with the nailing system. One patient died in the immediate post operative period from complications not directly related to the procedure and 3 were lost to follow up leaving a cohort of 40 patients for evaluation. 31 of the fractures were closed while the remaining 9 were open. The average age group of the cohort was 46.8 years with 26 males and 14 females. Results. All 40 patients were followed up to full radiological union of their tibia fractures. The average time to radiological union was 12.5 weeks for the closed fracture group and 15.1 weeks for the open fractures. The difference in time to union between the two groups was not statistically significant. There was infection around a distal locking screw in a closed fracture which settled with screw removal. Three patients in the closed fracture group required dynamisation to hasten union while none required dynamisation in the open fracture group. No bone grafting was performed on any of the patients. One patient had non union of a distal fibula fracture which required plating of as an additional procedure. On follow-up none of the patients reported knee pain or had limitation of ankle movements. Conclusion. The Expert tibial nail is an effective implant for the treatment of both open and closed distal tibial fractures with a low complication rate


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 206 - 206
1 May 2012
Schmutz B Rathnayaka K Wullschleger M Meek J Schuetz M
Full Access

Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of the tibia in adults. Anecdotal clinical evidence indicates that current nail designs do not fit optimally for Asian patients. This study aimed to develop a method to quantitatively assess the fitting of two nail designs for Asian tibiae. We used 3D models of two different tibial nail designs (ETN (Expert Tibia Nail) and ETN-Proximal-Bend, Synthes), and 20 CT-based 3D cortex models of Japanese cadaver tibiae. The nail models were positioned inside the medullary cavity of the intact bone models. The anatomical fitting between nail and bone was assessed by the extent of the nail protrusion from the medullary cavity into the cortical bone, which in a real bone would lead to axial malalignments of the main fragments. The fitting was quantified in terms of the total surface area, and the maximal distance of nail protrusion. In all 20 bone models, the total area of the nail protruding from the medullary cavity was smaller for the ETN-Proximal-Bend (average 540 mm2) compared to the ETN (average 1044 mm2). Also, the maximal distance of the nail protruding from the medullary cavity was smaller for the ETN-Proximal-Bend (average 1.2 mm) compared to the ETN (average 2.7 mm). The differences were statistically significant (p < 0.05) for both the total surface area and the maximal distance measurements. For all bone models, the nail protrusion occurred on the posterior side in the middle third of the tibia. For 12 bones the protrusion was slightly lateral to the centre of the shaft, for seven bones it was centred, and for one bone it was medial to the shaft. The ETN-Proximal-Bend shows a statistical significantly better intramedullary fit with less cortical protrusion than the original ETN. The expected clinical implications of an improved anatomical nail fit are fewer complications with malreduction and malalignments, a lower likelihood for fracture extension and/or new fracture creation during the nail insertion as well as an easier handling for the nail insertion. By utilising computer graphical methods we were able to conduct a quantitative fit assessment between implanted nail and bone geometry in 3D. In addition to the application in implant design, the developed method could potentially be suitable for pre-operative planning enabling the surgeon to choose the most appropriate nail design


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2022
Singhal A Jayaraju U Kaur K Clewer G
Full Access

Abstract. Background. With the increasingly accepted method of suprapatellar tibial nailing for tibial shaft fractures, we aimed to compare intraoperative and postoperative outcomes of infrapatellar (IP) vs suprapatellar (SP) tibial nails. Methods. A retrospective cohort analysis of 58 patients. 34 SP tibial nails over 3 years versus 24 IP tibial nails over a similar time frame. We compared; radiation exposure, patient positioning time (PPT), non-union rate and follow-up time. Knee pain in the SP group was evaluated, utilising the Hospital for Special Surgery (HSS) Knee injury and Osteoarthritis outcome score (KOOS). Results. 58 patients with a mean age of 43 years were included. Mean intraoperative radiation dose for SP nails was 61.78cGy (range 11.60 to 156.01cGy) vs 121.09cGy (range 58.01 to 18.03cGy) for IP nails (p < 0.05). Mean PPT for SP nails was 10 minutes vs 18 minutes for IP nails (p < 0.05). All fractures united in the SP group vs one non-union in the IP group. Mean follow-up was 5.5 months vs 11 months in the SP and IP group respectively. Mean KOOS was 7 (range 0 to 22) at 6 months for the SP group. Conclusion. The semi extended position (SP group) leads to reduced radiation exposure because of ease of imaging. All Patients in the SP group showed improved outcomes, with shorter follow-up and fracture union. The KOOS revealed SP nail patients had minimal pain and good knee function. This study establishes a management and PROMs baseline for ongoing evaluation of SP nails


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 15 - 15
23 Jul 2024
Hossain T Kimberley C Starks I Barlow T Barlow D
Full Access

Malalignment is a common complication following tibial surgery, occurring in 10% of fractures. This is associated with prolonged healing time and non-union. It occurs due to inability to maintain a satisfactory reduction. A reduction device, such as the Staffordshire Orthopaedic Reduction Machine (STORM), permits the surgeon to manipulate the fracture and hold it reduced. A retrospective parallel case series was undertaken of all patients undergoing tibial nails over a six-year period from 2014 to 2021. Patient demographics were obtained from medical records. Operative times obtained from the theatre IT system and included the time patient entered theatre and surgical start and finish times for each case. Anteroposterior and lateral long leg post-operative radiographs were reviewed. Angulation was measured in both coronal and sagittal planes, by two separate orthopaedic surgeons. A reduction was classified to be ‘mal-aligned’ if the angle measured was greater than 5 degrees. One tailed unpaired t-test was used to compare alignment in each plane. Bony union was assessed on subsequent radiographs and was determined according to the Radiographic Union Score for Tibial Fractures. 31 patients underwent tibial nail during the time period. 8 patients were lost to follow up and were excluded. Of the remaining 23 patients, the STORM device was utilised in 11. The overall mean alignment was acceptable across all groups at 2.17° in the coronal plane and 2.56° in the saggital plane. Analysing each group individually demonstrated an improved alignment when STORM was utilised: 1.7° (1°–3°) vs 2.54° (0°–5°) for the coronal plane and 1.6° (0°–3°) vs 3.31° (0°–9°) in the saggital plane. This difference was significant in saggital alignment (p=0.03) and showed a positive trend in coronal alignment, although was not significant (p=0.08). The time in theatre was shorter in the control group with a mean of 113 minutes (65 to 219) in comparison to STORM with a mean of 140 minutes (105 to 180), an increased theatre time of 27 minutes (p=0.04). This study demonstrates that STORM can be used in the surgical treatment of tibial fractures resulting in improved fracture alignment with a modest increase in theatre time


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 25 - 25
1 Jun 2023
Pincher B Kirk C Ollivere B
Full Access

Introduction. Bone transport and distraction osteogenesis have been shown to be an effective treatment for significant bone loss in the tibia. However, traditional methods of transport are often associated with high patient morbidity due to the pain and scarring caused by the external frame components transporting the bone segment. Prolonged time in frame is also common as large sections of regenerate need significant time to consolidate before the external fixator can be removed. Cable transport has had a resurgence with the description of the balanced cable transport system. However, this introduced increasingly complex surgery along with the risk of cable weave fracture. This method also requires frame removal and intramedullary nailing, with a modified nail, to be performed in a single sitting, which raised concern regarding potential deep infection. An alternative to this method is our modified cable transport system with early intramedullary nail fixation. Internal cables reduce pain and scarring of the skin during transport and allow for well controlled transport segment alignment. The cable system is facilitated through an endosteal plate that reduces complications and removes the need for a single-stage frame removal and nailing procedure. Instead, the patients can undergo a pin-site holiday before nailing is performed using a standard tibial nail. Early intramedullary nailing once transport is complete reduces overall time in frame and allows full weight bearing as the regenerate consolidates. We present our case series of patients treated with this modified cable transport technique. Methodolgy. Patients were identified through our limb reconstruction database and clinic notes, operative records and radiographs were reviewed. Since 2019, 8 patients (5 male : 3 female) have undergone bone transport via our modified balanced cable transport technique. Average age at time of transport was 39.6 years (range 21–58 years) with all surgeries performed by the senior author. Patients were followed up until radiological union. We recorded the length of bone transport achieved as well as any problems, obstacles or complications encountered during treatment. We evaluated outcomes of full weight bearing and return to function as well as radiological union. Results. 4/8 bone defects were due to severely comminuted open fractures requiring extensive debridement. All other cases had previously undergone fixation of tibial fractures which had failed due to infection, soft tissue defects or mal-reduction. The mean tibial defect treated with bone transport was 41mm (range 37–78mm). From the start of cable transport to removal of external fixator our patients spent an average of 201 days in frame. 7/8 patients underwent a 2-week pin-site holiday and subsequent insertion of intramedullary nail 2 weeks later. One patient had sufficient bony union to not require further internal fixation after frame removal. 10 problems were identified during treatment. These included 4 superficial infections treated with antibiotics alone and 5 issues with hardware, which could be resolved in the outpatient clinic. 1 patient had their rate of transport slowed due to poor skin quality over the site of the regenerate. 4 obstacles resulted in a return to theatre for additional procedures. 1 patient had a re-do corticotomy and 3 had revision of their internal cable transport constructs due to decoupling or screw pull out. 1 patient had residual ankle joint equinus following treatment which required an Achilles tendon lengthening procedure. Another patient underwent treatment for DVT. There were no deep infections identified and no significant limb length discrepancies or deformities. Conclusions. Overall, we have found that our modified balanced cable transport technique has allowed for successful bone transport for significant defects of the tibia. We have learned from the obstacles encountered during this case series to avoid unnecessary return trips to theatre for our future transport patients. The internal cable system allowed all patients to complete their planned transport without excessive pin tract scarring or pain. Early conversion to intramedullary nail allowed for a shorter time in frame with continued full weight bearing as the regenerate consolidated. No metalwork failure or deformity has occurred in relation to docking site union. All patients have made a good return to pre-operative function during their follow-up period with no evidence of late complications such as deep infection


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVII | Pages 26 - 26
1 May 2012
Judd S Shaju A Keogh P Kenny P O'Flanagan S
Full Access

Introduction. A comprehensive met-analysis of anterior knee pain post intramedullary nailing of the tibia was performed by Katsoulis et al in 2006. The principle findings were that 47.4% of patients had anterior knee pain at 2 years post tibial nailing. Worse results were found following a patella tendon splitting approach when compared with a medial para-patellar tendon approach. These conclusions were drawn from 20 studies including 1460 patients. Currently both approaches to the proximal tibia for nailing are used at JCMH Blanchardstown. A retrospective study was performed to compare the results of tendon splitting and tendon sparing approaches to tibial nails and to compare the results of JCMH with those stated in literature. Method. Patients who underwent tibial nailing in 2007 and 2008 were identified using the hospital coding system. Those patients who were treated under the care of Mr Kenny had a medial para-tendinous approach and those treated the care of Mr O'Flanagan and Mr Keogh had a tendon splitting approach. Apart from the approach the nailing technique using the Trigen Knee Nail and the post operative physiotherapy protocol were identical. Follow up included questions regarding knee pain and return to previous function. Specifically: Knee pain that affects daily life, Knee pain on kneeling, Knee pain on ascending or descending stairs, Return to work and Return to sports or active hobbies. Results. 61 patients were treated with intra-medullary nailing between 2007 and 2008 43 were available for follow for the purposes of this study (70 %). 25 had nails inserted via a tendon splitting approach and 18 via a tendon sparing approach. Only 5% of patients had knee pain that affected daily life, 16 % had pain on kneeling, 90% of patients who were previously at work returned to work and 75% of patients who were previously engaged in sports were able to return to these activities. Discussion. These results are significantly better than the figures stated in literature in terms of knee pain, return to work and sports. There was no significant difference between the 2 approaches to the tibia again in contradiction of available literature


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 37 - 37
1 Dec 2019
Sluga B Gril I Fischinger A
Full Access

Aim. Post traumatic distal tibia osteomyelitis (DTOM) with an upper ankle joint involvement is a serious complication after primary osteosynthesis and can be a nightmare for the patient and the surgeon as well. Our aim was to identify mayor complications during treatment and to find the way to prevent or treat them. Method. It is a retrospective analysis of eight patients with DTOM and an upper ankle joint involvement treated in our institution from 2012 to 2018. The average size of a bone defect after a debridement was 9 centimeters (4–15). Patients were treated in two stages. First stage was segmental bone resection, external fixation and soft tissue envelope reconstruction if necessary. At second stage a distraction frame was applied and proximal corticotomy performed. In all but one case a circular frame was used. Results. We have had one major intra-operative complication, an injury of arteria tibialis posterior during the corticotomy procedure. Except in one patient we did not observe major problems with pin-track infections. Despite bone-grafting in all patients, we observed three nonunions of docking site. We treated them by external fixator in two and retrograde intramedullar nail in one case. In two patient the distraction callus was weak. We had to bone graft and secure the callus with a plate in one and use a retrograde reamed intramedullar nail in second patient. We have observed two callus fracture after removal of the frame. A surgery was needed for both because of the deformation. The first patient was treated by new external frame, the second by retrograde reamed intramedullar nail. Conclusions. Callus distraction is a valuable option to treat a bone defect. The procedure has many possible problems and complications, especially during treatment of defects larger than six centimeters. It is very difficult for patients to tolerate a frame more than one year. We have found the use of an intramedullar tibial nail inserted in a retrograde way as a helpful option not just to shorten the time of external frame, but in combination with reaming also to accelerate the healing of the distraction callus and the upper ankle joint arthrodesis as well


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims

Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences.

Methods

A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 359 - 366
1 May 2022
Sadekar V Watts AT Moulder E Souroullas P Hadland Y Barron E Muir R Sharma HK

Aims

The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors.

Methods

We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims

The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices.

Methods

We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 72 - 72
1 Dec 2015
Benevenia J Patterson F Beebe K Rivero S
Full Access

In patients requiring two-stage procedures, stabilization of large skeletal defects after radical debridement must be attained in order to successfully treat the infection. With the use of standard rod plus antibiotic impregnated PMMA spacers limb salvage may be attempted with satisfactory results. Between 1992 and 2014, 23 patients were treated for hip, knee, or shoulder musculoskeletal infections resulting in an average skeletal defect of 22 cm. There were 13 males and 10 females. Twelve patients had infected tumor prostheses, seven patients had an infected total joint arthroplasty, and four patients had a primary infection involving a large skeletal defect. The mean time from the index procedure until infection was 22 months. Following debridement, the defect was stabilized with Tobramycin and Vancomycin impregnated PMMA and intramedullary nails. Patients were treated with IV and oral antibiotics for six weeks each. In 18 patients who had resection about the knee stabilization was achieved with a single femoral or tibial nail in nine patients and with two nails joined by a screw or cerclage wire in the other nine. In four patients a cephalomedullary femoral nail was used for stabilization after resection of the proximal or total femur. One patient had a custom total humeral prostalac using threaded Steinmann pins and 16-gauge wire. The organisms cultured were gram positive in 19 cases, mixed gram positive and fungal in one, mixed gram negative and mycobacterium in one, and two patients had no growth on cultures but histologic evidence of acute infection. Of the 23 patients, 16 were successfully reimplanted following the initial procedure (70%) and seven had recurrent infections. Three patients with recurrent infections were successfully reimplanted after an additional one-stage procedure and four patients were not reimplanted. Two of these four had amputations and the other two had a second two-stage procedure and have retained their spacers. There were seven complications including a broken spacer, three periprosthetic fractures, two contractures, and one case of aseptic loosening. Successful limb salvage with infection control was 19/23 (83%). One patient required an amputation for local recurrence of their tumor. The overall limb salvage rate was 18/23 (78%). Stable temporary antibiotic laden cement spacers, made in conjunction with standard intramedullary nails, can provide the necessary limb stability to treat musculoskeletal infections and allow for reimplanation of tumor prostheses for limb salvage


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 78 - 78
1 Oct 2012
Schroeder J Fliri L Liebergall M Richards G Windolf M
Full Access

The common practice for insertion of distal locking screws of intramedullary (IM) nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure to patient and surgical personnel. A new technique is introduced which guides the surgeon by landmarks on the X-ray projection. 18 fresh frozen human below-knee specimens (incl. soft tissue) were used. Each specimen was instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland) and was mounted on an OR-table. Two distal interlocking techniques were performed in random order using a Siemens ARCADIS C-arm system (Siemens AG, Munich, Germany). The newly developed guided technique, guides the surgeon by visible landmarks projected onto the fluoroscopy image. A computer program plans the drilling trajectory by 2D-3D conversion and provides said guiding landmarks for drilling in real-time. No additional tracking or navigation equipment is needed. All four distal screws (2 mediolateral, 2 anteroposterior) were placed in each procedure. Operating time, number of taken X-rays and radiation time were recorded per procedure and for each single screw. 8 procedures were performed with the freehand technique and 10 with the guided technique. A 58% reduction in number of fluoroscopy shots per screw was found for the guided technique (7.4±3.4 vs. 17.6±10.3; p < 0.001). Total radiation time was 55% lower for the guided technique (17.1 ± 3.7s vs. 37.9 ± 9.1s) (p = 0.001). Operating time was shorter by 22% in the guided technique (3.2±1.2 min vs. 4.1±2.1 min p = 0.018). In an experimental setting, the newly developed guided freehand technique has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method enhances established clinical workflows and does not require cost intensive add-on devices or extensive training. A newly developed simple navigated technique has proven to markedly reduce radiation exposure and time for distal locking of intramedullary nails


Bone & Joint Open
Vol. 1, Issue 6 | Pages 229 - 235
9 Jun 2020
Lazizi M Marusza CJ Sexton SA Middleton RG

Aims

Elective surgery has been severely curtailed as a result of the COVID-19 pandemic. There is little evidence to guide surgeons in assessing what processes should be put in place to restart elective surgery safely in a time of endemic COVID-19 in the community.

Methods

We used data from a stand-alone hospital admitting and operating on 91 trauma patients. All patients were screened on admission and 100% of patients have been followed-up after discharge to assess outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 938 - 942
1 Jul 2006
Singh S Lahiri A Iqbal M

Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest.

The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 146 - 152
1 Jan 2010
Bilen FE Kocaoglu M Eralp L Balci HI

We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed.

The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60).

One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation.

We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.