Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 71 - 71
11 Apr 2023
Pelegrinelli A Kowalski E Ryan N Dervin G Moura F Lamontagne M
Full Access

The study compared thigh-shank and shank-foot coordination during gait before and after total knee arthroplasty (TKA) with controls (CTRL). Twenty-seven patients (male=15/female=12; age=63.2±6.9 years) were evaluated one month prior to and twelve months after surgery, and compared to 27 controls (male=14/female=13; age=62.2±4.3). The participants were outfitted with a full-body marker set. Gait speed (normalized by leg length) was calculated. The time series of the thigh, shank, and foot orientation in relation to the laboratory coordinate system were extracted. The coordination between the thigh-shank and shank-foot in the sagittal plane were calculated using a vector coding technique. The coupling angles were categorized into four coordination patterns. The stance phase was divided into thirds: early, mid, and late stance. The frequency of each pattern and gait speed were compared using a one-way ANOVA with a post-hoc Bonferroni correction. Walking speed and shank-foot coordination showed no differences between the groups. The thigh-shank showed differences. The pre-TKA group showed a more in-phase pattern compared to the CTRL group during early-stance. During mid-stance, the pre- and post-TKA presented a more in-phase pattern compared to the CTRL group. Regarding shank-foot coordination, the groups presented an in-phase and shank pattern, with more shank phase during mid-stance and more in-phase during late-stance. The pre-TKA group showed greater differences than the post-TKA compared to the controls. The more in-phase pattern in the pre- and post-TKA groups could relate to a reduced capacity for the thigh that leads the movement. During mid-stance in normal gait, the knee is extending, where the thigh and shank movements are in opposite directions. The in-phase results in the TKA groups indicate knee stiffness during the stance phase, which may relate to a muscular deficit or a gait strategy to reduce joint stress


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 54 - 54
2 Jan 2024
İlicepinar Ö Imir M Cengiz B Gürses S Menderes Y Turhan E Dönmez G Korkusuz F
Full Access

Hop tests are used to determine return to sports after ACL reconstruction. They mostly measure distance and symmetry but do not assess kinematics and kinetics. Recently, biomechanical evaluations have been incorporated into these functional jump tests for the better assessment of return to sport. We assessed the sagittal plane range of motion (ROM) of the knee, the deviation axis of rotation (DAOR), and the vertical ground reaction force (vGRF) normalized to body weight in nine healthy participants during the single leg (SLH) and crossover hop tests (COHT). Participants' leg lengths were measured. Jumping distances were marked in the test area as being 4/5 of the leg length. Four sensors were placed on the thighs, the legs and the feet. These body parts were handled as a single rigid body. Eight 480 Hz cameras were used to capture the movements of these rigid bodies. vGRF at landing were measured using a force plate (Bertec, Inc, USA). The ROM of the knee joint and the DAOR were obtained from kinematic data. Participants' joint kinematics metrics were similar in within-subjects statistical tests for SLH and COHT. We therefore asked whether the repeated vGRF normalized to body weight will be similar in both legs during these jumps. Joint kinematics metrics however were different in between subjects indicating the existence of a personalized jumping strategy. These hop tests can be recorded at the beginning of the training season for each individual, which can establish a comparative evaluation database for prospective lower extremity injury recovery and return to sport after ACL injury


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 42 - 42
1 Dec 2020
Özkan Ö Karaçoban L Dönmez G Korkusuz F
Full Access

Adductor strain is a common injury among football players. The adductor muscle group contains the three adductor muscles. (adductor longus, magnus and brevis) Adductor longus muscle is a triangular-shaped long muscle. This muscle originates from the superior ramus of the pubic bone and inserted into the middle part of the linea aspera. Adductor longus muscle is the most commonly injured muscle of adductors. Sudden acceleration, jumping, stretching, and kicking the ball are common causes of an adductor injury. Adductor muscle strains can result in missed playing time for football players. We present a 26-year-old man soccer player with pain in the left groin and proximal thigh. The symptoms had started during training and after kicking the ball with left foot (dominant side), he felt an acute pain in the groin region and proximal thigh. Despite the injury, he managed to finish the training. The team physician examined the patient immediately after training. The range of motion of both hip joints was in normal ranges and mild pain with adduction. There was a palpable mass at the inner proximal thigh during contraction of adductor muscles. There was no history of groin pain or adductor problems before this injury. Conventional radiographs showed no osseous abnormalities. 36 hours after the injury, MRI revealed acute grade IIB strain in the left adductor longus muscle, including both superior and inferior parts of the muscle. A hematoma was observed in the superior part of the left adductor muscle, with a craniocaudal length of 42 millimeters. There was an adductor muscle strain with hyperintensity extending for a craniocaudal length of approximately 12 centimeters involving more than 50% crosses sectional diameter of the muscle belly. Conservative treatment started immediately, consisting of cold therapy and soft tissue massage. Compression of the injured tissue using a 15-cm elastic bandage roll is done to limit bleeding and provide support. Iced water machine (Game Ready) was used. The team physician examined the player every day and prescribed physiotherapy protocol daily. Additionally, short interval follow-up MRI is used to evaluate the injury. (After 7 and 14 days of the injury) No injection was performed. The player is able to return to play immediately, despite MRI's strain images. The player started straight running 5 days later and joined to team training 8 days later and played 90 minutes-league-match 12 days after injury without any pain. No injection was performed. The player is able to return to play immediately, despite MRI's strain images. The player started straight running 5 days later and joined to team training 8 days later and played 90 minutes-league-match 12 days after injury without any pain. MRI is a useful technique in diagnosing trauma in football players presenting with groin pain. In this case, to estimate time-to-return-to-play, MRI alone is not strong evidence. MRI is a good option for follow up, but anamnesis and clinical examination is not inferior to diagnostic imaging


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 82 - 82
2 Jan 2024
Özer Y Karaduman D Karanfil Y Çiftçi E Balci C Doğu B Halil M Cankurtaran M Korkusuz F
Full Access

Osteoarthritis (OA) of the knee joint is a complex peripheral joint disorder with multiple risk factors. We aimed to examine the relationship between the grade of knee OA and anterior thigh length (ATL). A total of 64 geriatric patients who had no total hip or knee replacement with a BMI of ≥30 were evaluated. Patients' OA severity was determined by two independent experts from bilateral standing knee radiographs according to the Kellgren-Lawrence (KL) grade. Joint cartilage structure was assessed using ultrasonography (US). The ATL, the gastrocnemius medialis (GC), the rectus femoris (RF) and the rectus abdominis (RA) skeletal muscle thicknesses as well as the RF cross-sectional area (CSA) were measured with US. Sarcopenia was diagnosed using the handgrip strength (HGS), 5× sit-to-stand test (5xSST) and bioelectrical impedance analysis. The median (IQR) age of participants was 72 (65–88) years. Seventy-one per cent of the patients (n=46) were female. They were divided into the sarcopenic obese (31.3 %) and the non-sarcopenic obese (68.8%) groups. KL grade of all patients correlated negatively with the ATL (mm) and the thickness of GC (mm) (r= -0,517, p<0.001 and r= -0.456, p<0.001, respectively). In the sarcopenic obese and the non-sarcopenic obese groups, KL grade of the all patients was negatively correlated with ATL (mm) and thickness of GC (mm) (r= -0,986, p<0.001; r= -0.456, p=0.05 and r= -0,812, p=0.002; r= −0,427, p=0.006). KL grade negatively correlated with the RF thickness in the sarcopenic obese group (r= -0,928, p=0.008). In conclusion, OA risk may decrease as the lower extremity skeletal muscle mass increases. Acknowledgments: Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 134 - 134
4 Apr 2023
Arrowsmith C Alfakir A Burns D Razmjou H Hardisty M Whyne C
Full Access

Physiotherapy is a critical element in successful conservative management of low back pain (LBP). The aim of this study was to develop and evaluate a system with wearable inertial sensors to objectively detect sitting postures and performance of unsupervised exercises containing movement in multiple planes (flexion, extension, rotation). A set of 8 inertial sensors were placed on 19 healthy adult subjects. Data was acquired as they performed 7 McKenzie low-back exercises and 3 sitting posture positions. This data was used to train two models (Random Forest (RF) and XGBoost (XGB)) using engineered time series features. In addition, a convolutional neural network (CNN) was trained directly on the time series data. A feature importance analysis was performed to identify sensor locations and channels that contributed most to the models. Finally, a subset of sensor locations and channels was included in a hyperparameter grid search to identify the optimal sensor configuration and the best performing algorithm(s) for exercise classification. Models were evaluated using F1-score in a 10-fold cross validation approach. The optimal hardware configuration was identified as a 3-sensor setup using lower back, left thigh, and right ankle sensors with acceleration, gyroscope, and magnetometer channels. The XBG model achieved the highest exercise (F1=0.94±0.03) and posture (F1=0.90±0.11) classification scores. The CNN achieved similar results with the same sensor locations, using only the accelerometer and gyroscope channels for exercise classification (F1=0.94±0.02) and the accelerometer channel alone for posture classification (F1=0.91±0.03). This study demonstrates the potential of a 3-sensor lower body wearable solution (e.g. smart pants) that can identify proper sitting postures and exercises in multiple planes, suitable for low back pain. This technology has the potential to improve the effectiveness of LBP rehabilitation by facilitating quantitative feedback, early problem diagnosis, and possible remote monitoring


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 89 - 89
17 Apr 2023
Alzahrani S Aljuaid M Bazaid Z Shurbaji S
Full Access

A Morel-Lavallee lesion (MLL) is a benign cystic lesion that occurs due to injury to the soft-tissue envelope's perforating vascular and lymphatic systems, resulting in a distinctive hemolymphatic fluid accumulation between the tissue layers. The MLL has the potential to make a significant impact on the treatment of orthopaedic injuries. A 79-year-old male patient community ambulatory with assisting aid (cane) known case of Diabetes mellitus, hypertension, bronchial asthma and ischemic heart disease. He was brought to the Emergency, complaining of right hip discomfort and burning sensation for the last 5 days with no history of recent trauma at all. Patient had history of right trochanteric femur fracture 3 years ago, treated with DHS in a privet service. Clinical and Radiological assessment showed that the patient mostly has acute MLL due to lag screw cut out. We offered the patient the surgical intervention, but he refused despite explaining the risks of complications if not treated and preferred to receive the conservative treatment. Compression therapy management explained to him including biker's shorts (instructed to be worn full-time a day) and regular follow up in clinic. Symptom's improvement was reported by the patient in the subsequent visits. In the polytrauma patient, a delayed diagnosis of these lesions is conceivable due to the presence of more visible injuries. It's located over the greater trochanter more commonly, but sometimes in other areas such as the lower lumbar region, the thigh, or the calf. Incorrect or delayed diagnosis and care can have unfavorable outcomes such as infection, pseudocyst development, and cosmetologically deformity. Magnetic resonance imaging (MRI) and ultrasound will aid in MLL diagnosis. However, the effectiveness of MLL therapy remains debatable. We strongly believe that the MLL caused due to tangential shear forces applied to the soft tissue leads to accumulation of the blood and/or lymph between the subcutaneous and overlying fascia and it often misdiagnosed due to other distracting injuries. Nontheless, in our case we reported MLL occur due to internal pressure on the fascia caused by cut out of DHS lag screw


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 84 - 84
4 Apr 2023
Gehweiler D Pastor T Beeres F Kastner P Migliorini F Nebelung S Scaglioni M Souleiman F Link B Babst R Gueorguiev B Knobe M
Full Access

Helical plates potentially bypass the medial neurovascular structures of the thigh. Recently, two plate designs (90°- and 180°-helix) proved similar biomechanically behaviour compared to straight plates. Aims of this study were: (1) Feasibility of MIPO-technique with 90°- and 180°-helical plates on the femur, (2) Assessment of distances to adjacent anatomical structures at risk, (3) Comparison of these distances to using medial straight plates instead, (4) Correlation of measurements performed in anatomic dissection with CT-angiography. MIPO was performed in ten cadaveric femoral pairs using either a 90°-helical 14-hole-LCP (Group1) or a 180°-helical 15-hole-LCP-DF (Group2). CT angiography was used to evaluate the distances between the plates and the femoral arteries as well as the distances between the plates and the perforators. Subsequently, the specimens were dissected, and the distances were determined again manually. Finally, all helical plates were removed, and all measurements were repeated after application of straight medial plates (Group3). Closest overall distances between plates and femoral arteries were 15 mm (11 − 19 mm) in Group1, 22 mm (15 − 24 mm) in Group2 and 6 mm (1 − 8 mm) in Group3 with a significant difference between Group1 and Group3 (p < 0.001). Distances to the nearest perforators were 24 mm (15 − 32 mm) in Group1 and 2 mm (1 − 4 mm) in Group2. Measurement techniques (visual after surgery and CT-angiography) demonstrated a strong correlation of r. 2. = 0.972 (p < 0.01). MIPO with 90°- and 180°-helical plates is feasible and safe. Attention must be paid to the medial neurovascular structures with 90°-helical implants and to the proximal perforators with 180°-helical implants. Helical implants can avoid medial neurovascular structures compared to straight plates although care must be taken during their distal insertion. Measurements during anatomical dissection correlate with CT-angiography


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 16 - 16
17 Apr 2023
Hornestam J Miller B Carsen S Benoit D
Full Access

To investigate differences in the drop vertical jump height in female adolescents with an ACL injury and healthy controls and the contribution of each limb in this task. Forty female adolescents with an ACL injury (ACLi, 15.2 ± 1.4 yrs, 164.6 ± 6.0 cm, 63.1 ± 10.0 kg) and thirty-nine uninjured (CON, 13.2 ± 1.7 yrs, 161.7 ± 8.0 cm, 50.6 ± 11.0 kg) were included in this study. A 10-camera infrared motion analysis system (Vicon, Nexus, Oxford, UK) tracked pelvis, thigh, shank, and foot kinematics at 200Hz, while the participants performed 3 trials of double-legged drop vertical jumps (DVJ) on two force plates (Bertec Corp., Columbus, USA) sampled at 2000Hz.The maximum jump height normalised by dominant leg length was compared between groups using independent samples t-test. The maximum vertical ground reaction force (GRFz) and sagittal ankle, knee and hip velocities before take-off were compared between limbs in both groups, using paired samples t-test. The normalised jump height was 11% lower in the ACLi than in the CON (MD=0.04 cm, p=0.020). In the ACLi, the maximum GRFz (MD=46.17N) and the maximum velocities of ankle plantar flexion (MD=79.83°/s), knee extension (MD=85.80°/s), and hip extension (MD=36.08°/s) were greater in the non-injured limb, compared to the injured limb. No differences between limbs were found in the CON. ACL injured female adolescents jump lower than the healthy controls and have greater contribution of their non-injured limb, compared to their injured limb, in the DVJ task. Clinicians should investigate differences in the contribution between limbs during double-legged drop vertical jump when assessing patients with an ACL injury, as this could help identify asymmetries, and potentially improve treatment, criteria used to clear athletes to sport, and re-injury prevention


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 53 - 53
2 Jan 2024
Ghaffari A Clasen P Boel R Kappel A Jakobsen T Kold S Rahbek O
Full Access

Wearable inertial sensors can detect abnormal gait associated with knee or hip osteoarthritis (OA). However, few studies have compared sensor-derived gait parameters between patients with hip and knee OA or evaluated the efficacy of sensors suitable for remote monitoring in distinguishing between the two. Hence, our study seeks to examine the differences in accelerations captured by low-frequency wearable sensors in patients with knee and hip OA and classify their gait patterns. We included patients with unilateral hip and knee OA. Gait analysis was conducted using an accelerometer ipsilateral with the affected joint on the lateral distal thighs. Statistical parametric mapping (SPM) was used to compare acceleration signals. The k-Nearest Neighbor (k-NN) algorithm was trained on 80% of the signals' Fourier coefficients and validated on the remaining 20% using 10-fold cross-validation to classify the gait patterns into hip and knee OA. We included 42 hip OA patients (19 females, age 70 [63–78], BMI of 28.3 [24.8–30.9]) and 59 knee OA patients (31 females, age 68 [62–74], BMI of 29.7 [26.3–32.6]). The SPM results indicated that one cluster (12–20%) along the vertical axis had accelerations exceeding the critical threshold of 2.956 (p=0.024). For the anteroposterior axis, three clusters were observed exceeding the threshold of 3.031 at 5–19% (p = 0.0001), 39–54% (p=0.00005), and 88–96% (p = 0.01). Regarding the mediolateral axis, four clusters were identified exceeding the threshold of 2.875 at 0–9% (p = 0.02), 14–20% (p=0.04), 28–68% (p < 0.00001), and 84–100% (p = 0.004). The k-NN model achieved an AUC of 0.79, an accuracy of 80%, and a precision of 85%. In conclusion, the Fourier coefficients of the signals recorded by wearable sensors can effectively discriminate the gait patterns of knee and hip OA. In addition, the most remarkable differences in the time domain were observed along the mediolateral axis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 61 - 61
17 Apr 2023
Lodewijks L Blokhuis T Poeze M
Full Access

The need for an artificial scaffold in very large bone defects is clear, not only to limit the risk of graft harvesting, but also to improve clinical success. The use of custom osteoconductive scaffolds made from biodegradable polyester and ceramics can be a valuable patient friendly option, especially in case of a concomitant infection. Multiple types of scaffolds for the Masquelet procedure (MP) are available, however these frequently demonstrate central graft involution when defects exceed a certain size and the complication rates remains high. This paper describes three infected tibial defect nonunions with a segmental defect over ten centimeters long treated with a customized 3D printed polycaprolactone-tricalcium phosphate (PCL-TCP) cage in combination with biological adjuncts. Three male patients, between the age of 37 and 47, were treated for an infected tibial defect nonunion after sustaining Gustilo grade 3 open fractures. All had a segmental midshaft bone defect of more than ten centimeters (range 11–15cm). First stage MPs consisted of extensive debridement, external fixation and placement of anterior lateral thigh flaps (ALT). Positive cultures were obtained from all patients during this first stage, that were treated with specific systemic antibiotics during 12 weeks. The second stage MP was carried out at least two months after the first stage. CT scans were obtained after the first stage to manufacture defect-specific cages. In the final procedure a custom 3D printed PCL-TCP cage (Osteopore, Singapore) was placed in the defect in combination with biological adjuncts (BMAC, RIA derived autograft, iFactor and BioActive Glass). Bridging of the defect, assessed at six months by CT, was achieved in all cases. SPECT-scans 6 months post-operatively demonstrated active bone regeneration, also involving the central part of the scaffold. All three patients regained function and reported less pain with full weight-bearing. This case report shows that 3D printed PCL-TCP cages in combination with biological adjuncts is a novel addition to the surgical treatment of very large bone defects in (infected) posttraumatic nonunion of the tibia. This combination could overcome some of the current drawbacks in this challenging indication


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 46 - 46
1 Oct 2016
Nair A Dolan J Tanner KE Pollock PJ Kerr C Oliver FB Watson MJ Jones B Kellett CF
Full Access

Adductor canal blocks offer an alternative to femoral nerve block for postoperative pain relief in knee arthroplasty. They may reduce the risk of quadriceps weakness, allowing earlier mobilisation of patients postoperatively. However, little is known about the effect of a tourniquet on the distribution of local anaesthetic in the limb. Ultrasound-guided adductor canal blocks were performed on both thighs of five human cadavers. Left and right thighs of each cadaver were randomised to tourniquet or no tourniquet for one hour. Iohexol radio-opaque contrast (Omnipaque 350) was substituted for the local anaesthetic for X-Ray imaging. All limbs underwent periodic flexion and extension during this hour to simulate positioning during surgery. The cadavers were refrozen. Fiducial markers were inserted into the frozen tissue. X-rays were obtained in 4 planes (AP, lateral 45° oblique/medial oblique, lateral). University Research Ethics Approval was obtained and cadavers were all pre-consented for research, imaging and photography according to the Anatomy Act (1984). Analysis of radiographs showed contrast distribution in all thighs to be predominantly on the medial aspect of the thighs. The contrast margins were entire and well circumscribed, strongly suggesting it was largely contained within the aponeurosis of the adductor canal. Tourniquets appeared to push the contrast into a narrower and more distal spread along the length of the thigh compared to a more diffuse spread for those without. Proximal spread towards the femoral triangle was reduced in limbs without tourniquets. The results suggest that contrast material may remain within the adductor canal structures during adductor canal blocks. Tourniquets may cause greater distribution of contrast proximally and distally in the thigh, but this does not appear to be clinically significant. Further studies might include radio-stereo photometric analysis using the fiducial markers in the limbs and in vivo studies to show the effect of haemodynamics on distribution


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 24 - 24
1 Nov 2018
Kepple T Bradley K Loan P Tashman S Anderst W De Asha A
Full Access

Conventional marker based optical motion capture (mocap) methods for estimating the position and orientation (pose) of anatomical segments use assumptions that anatomical segments are rigid bodies and the position of tracking markers is invariant relative to bones. Soft tissue artefact (STA) is the error in pose estimation due to markers secured to soft tissue that moves relative to bones. STA is a major source of pose estimation error and is most prevalent when markers are placed over joints. Mocap and bi-plane videoradiography data were recorded synchronously while three individuals walked on a treadmill. For all three, pose of the thigh and shank, and movement of markers relative to the bones, were determined from the videoradiography data (DSX, C-Motion). Independently, pose of thighs and shanks was estimated using mocap data (Visual3D, C-Motion). Our measures of error in the mocap pose estimation were the relative thigh and shank translations. X-ray data from two subjects were used to generate a regression model for the antero/posterior movement of the lateral knee marker against internal/external hip rotation. The mocap translation errors of the third subject, attributed to STA of the knee marker, were 15.6mm and 32.0mm respectively. The pose of the third subject was then estimated using a probabilistic algorithm incorporating our regression model. Mocap translation errors were reduced to 10.6mm (thigh) and 4.4mm (shank). The results from these data suggest that errors in pose estimation due to STA may possibly be reduced via the application of algorithms based on probabilistic inference to mocap data


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 21 - 21
1 Nov 2021
Kaya CS Yucesoy CA
Full Access

Introduction and Objective. Clinically, it is considered that spastic muscles of patients with cerebral palsy (CP) are shortened, and produce higher force in shorter muscle lengths. Yet, direct quantification of spastic muscles’ forces is rare. Remarkably, previous intraoperative tests in which muscle forces are measured directly as a function of joint angle showed for spastic gracilis (GRA) that its passive forces are low, and only a small percentage of its maximum active force is measured in flexed knee positions. However, the relationship of force characteristics of spastic GRA with its muscle-tendon unit length (l. MTU. ) is unknown. Combining intraoperative experiments with participants’ musculoskeletal models developed based on their gait analyses, we aimed to test if spastic GRA muscle (1) operates at short l. MTU. compared to that of typically developing (TD) children, and exerts higher (2) passive and (3) active forces at shorter lengths, within gait-relevant l. MTU. range. Materials and Methods. Ten limbs of seven children with CP (GMFCS-II) were tested. Pre-surgery, gait analyses were conducted. Intraoperatively, isometric spastic GRA distal forces were measured in ten hip-knee joint angle combinations, in two conditions: (i) passive state and (ii) maximal activation of the GRA exclusively. In OpenSim, gait_2392 model was used for each limb to calculate l. MTU. 's per each hip and knee angle combination and the gait-relevant l. MTU. range, and to analyze gait relevant spastic muscle force - l. MTU. data. l. MTU. values were normalized for the participants’ thigh lengths. Two-way ANOVA was used to compare the patients’ l. MTU. to those of the seven age-matched TD children to test the first hypothesis. In order to test the second and the third hypotheses, Spearman's rank correlation coefficient (ρ) was calculated to seek a correlation between the muscle's operational length (represented by mean l. MTU. within gait cycle) and muscular force characteristics (the percent force at shortest l. MTU. of peak force, either in passive or in active conditions) within gait-relevant l. MTU. range. Results. ANOVA showed that l. MTU. 's of spastic GRA are shorter (on average by 15.4%) compared to those of TD. At the shortest gait-relevant l. MTU. , the GRA passive force was 84.6 (13.7)% of the peak passive force; and the active force was 55.8 (33.9)% of the peak active force. Passive state forces show an increase at longer lengths, whereas active state force characteristics vary in a patient-specific way. Spearman's rank correlation indicated weak correlations between muscle's operational length and muscular force characteristics (ρ= −0.30 P= 0.40, and ρ= −0.27 P= 0.45, for passive and active states, respectively). Therefore, only the first hypothesis was confirmed. Conclusions. Novel muscle force - l. MTU. data for spastic GRA were obtained using intraoperative data and modelling combined. The modelling showed in concert with the clinical considerations that spastic GRA may be a shortened muscle. However, because the model does not distinguish the muscle-belly and tendon lengths, it cannot isolate shorter muscle belly length and how this compares to the data of TD children remains unknown. Moreover, the absence of a strong correlation between shorter operational muscle length and higher force production either in passive or in active conditions highlights the influence of other factors (e.g., muscle structural proteins, and muscle mechanical characteristics including intermuscular interactions etc.) on the pathology rather than ascribing it solely to the length of a spastic muscle itself


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 2 - 2
1 Mar 2021
McAleese T Clesham K Moloney D Hughes A Faheem N Merghani K
Full Access

Abstract. Background. Schwannomas are slow-growing, benign tumours normally originating from the Schwann cells of the nerve sheath. Intraosseous schwannoma accounts for 0.175% of primary bone tumours and extremely rare especially outside the axial skeleton. Monoclonal gammopathy has been associated with soft tissue schwannomas but never with the intraosseous variety. Presenting problem. A 55-year-old woman with a background of monoclonal gammopathy of undetermined significance (MGUS) presented with a 2-year history of right thigh pain. CT scan showed a well defined, lytic lesion with a thin peripheral rim of sclerosis in the midshaft of the femur. MRI displayed a hyperintense, well marginated and homogenous lesion. Definitive diagnosis was made based on the classical histopathological appearance of schwannoma. Clinical management. We managed our patient with local curettage and prophylactic cephalomedullary nailing on the basis of a high mirel score. Discussion. Intraosseous schwannomas are poorly understood but most commonly reported in middle-aged women. Radiologically, their differential diagnosis includes malignant bone tumours, solitary bone cysts, aneurysmal bone cysts and giant cell tumours. As a result, they are usually diagnosed incidentally on histology. Although malignant transformation is possible in soft tissue schwannomas, all intraosseous schwannomas reported to date have been benign. This case demonstrates the importance of suspecting intraosseous schwannoma as a differential diagnosis for lytic bone lesions to avoid the overtreatment of patients. We also highlight monoclonal gammopathy of undetermined significance as a potential risk factor for a poorly understood disease and make recommendations about the appropriate management of these lesions. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 92 - 92
1 Dec 2020
Hanberg P Bue M Kabel J J⊘rgensen AR Jessen C S⊘balle K Stilling M
Full Access

Tourniquet is widely used in orthopedic surgery to reduce intraoperative bleeding and improve visualization. We evaluated the effect of tourniquet application on both peri- and postoperative cefuroxime concentrations in subcutaneous tissue, skeletal muscle, calcaneal cancellous bone, and plasma. The primary endpoint was the time for which the free drug concentration of cefuroxime was maintained above the clinical breakpoint minimal inhibitory concentration (T>MIC) forStaphylococcus aureus (4 µg/mL). Ten patients scheduled for hallux valgus or hallux rigidus surgery were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in subcutaneous tissue, skeletal muscle, and calcaneal cancellous bone. A tourniquet was applied on the thigh of the leg scheduled for surgery. Cefuroxime (1.5 g) was administered intravenously as a bolus 15 minutes prior to tourniquet inflation, followed by a second dose 6 hours later. The mean tourniquet duration (range) was 65 (58; 77) minutes. Dialysates and venous blood samples were collected for 12 hours. For cefuroxime the T>MIC (4 μg/mL) ranged between 4.8–5.4 hours across compartments, with similar results for the tourniquet and non-tourniquet leg. Comparable T>MIC and penetration ratios were found for the first and second dosing intervals. We concluded that administration of cefuroxime (1.5 g) 15 minutes prior to tourniquet inflation is safe in order to achieve tissue concentrations above 4 µg/mL throughout surgery. A tourniquet application time of approximately 1 hour did not affect the cefuroxime tissue penetration in the following dosing interval


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 6 - 6
1 Jan 2017
Li L St Mart J Tweedie B Kurek N Somasundaram K Huber C Babu V
Full Access

There has been evidence of association between femoral shaft fractures and prolonged bisphosphonate therapy. We present a case series of bisphosphonate-associated fractures and invaluable lessons we have learnt. Over the last three years at our unit we have collected a case series of eight patients who have had atypical femoral fractures whilst on bisphosphonate therapy. We present illustrative cases, a summary of key findings, and invaluable lessons we have learnt. There was a long period of prodromal pain for two years before incomplete fractures developed. We speculate this is a warning sign of impending fracture. This may have been prevented with screening. Between incomplete fracture and complete fracture there was a short window of one month. Five patients presented with complete fracture, and three with thigh pain +/- evidence of incomplete fracture. Of the latter group all but one went on to develop complete fractures. The one patient who did not progress died six years after diagnosis. Of those five patients who presented with initial complete fracture, three patients recall thigh pain before fracture on further questioning. Despite being diaphyseal femoral fractures, there is a higher risk of neck of femur fractures in this patient cohort (both patients with initial interlocked nails subsequently developed neck of femur fractures soon after and were revised to cephalomedullary nails). Excluding one death from unrelated cause, only one patient has signs of complete fracture healing. All other patients are still receiving follow-up (mean 490 days). Three patients reported bilateral symptoms (pain). Two had had bilateral symptoms for one year. Both had visible incomplete fractures on further radiographic scrutiny; one underwent prophylactic cephalomedullary nailing, one was managed with active surveillance. We suggest that improved pain and radiographic changes of cortical healing may be misleading and should not be relied upon. Cephalomedullary nailing is the treatment of choice in these fractures due to higher risk of neck of femur fractures in this cohort. We suggest prompt prophylactic cephalomedullary nailing when radiographic incomplete fractures are identified due to a short window before progression to complete fracture, and the need to consider contralateral prophylactic nailing in patients describing bilateral symptoms. We speculate that thigh pain is a warning sign of impending fracture and fracture-progression can be prevented with appropriate screening


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 5 - 5
1 Dec 2020
Ulucakoy C Atalay İB Yapar AE Ekşioğlu MF Kaptan AY Doğan M
Full Access

Purpose. Extraskeletal chondrosarcoma is a rare tumor with an indolent course and high propensity for local recurrence and metastasis. This tumor most commonly presents in the proximal extremities of middle-aged males, and is commonly asymptomatic. Although slow growing, these tumors have a significant risk of eventual relapse and metastases, especially to the lung. There are no clinical trials that investigated the best treatment options for this tumor given its very low incidence. The aim of this study is to present the surgical and clinical results of extraskeletal chondrosarcoma, which is a rare tumor. Methods. In our clinic, the information of 13 patients who were diagnosed with extra-skeletal chondrosarcoma between 2006 and 2018 were retrospectively reviewed. Demographic information, tumor size, surgical treatments, chemotherapy and radiotherapy status, follow-up times, recurrence and metastases of the patients were recorded. Results. This study included 13 patients with an average age of 53.6 ± 15 (range, 28 to 73) years diagnosed with extraskelatal chondrosarcoma. In 8 of the patients, the tumor was located in the lower limbs and it was observed that the thigh was located mostly (46.2%). The mean follow-up period of the patients was 52.8 ± 19.9 (range, 24 to 96) months. All patients underwent extensive resection and only one patient had a positive surgical margin. In the follow-up, 5 (38.5%) of the patients developed recurrence, while 6 patients had lung metastasis (46.2%) and 53.8% (7 patients) of the patients exitus. The mean tumor size was 10.4 ± 3.2 (range, 5 to 17) cm. The median survival time of the patients in the study was 61 (50.5–71.4) months. The 5-year survival rate is 51.8%. There was no significant difference between survival times according to age, gender, side, limb location, postoperative RT, recurrence and presence of lung metastasis (log rank tests p > 0.05). The cut off value for exitus obtained by ROC analysis of tumor size was determined as 11 cm (fig 1). Accordingly, the survival time of patients with 11 cm and above tumor size was observed to be statistically significantly shorter. Conclusion. Consequently, ECM is a rare soft tissue sarcoma with high local recurrence and metastasis capacity. Therefore, close follow-up is recommended. The first option should be extensive resection. Studies with large patient series on the prognostic factors of the future ECM are needed. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 8 - 8
1 Dec 2020
Kaya C Yucesoy C
Full Access

Background. Spastic muscles of patients with cerebral palsy (CP) are considered structurally as shortened muscles, that produce high force in short muscle lengths. Yet, previous intraoperative studies in which muscles’ forces are measured directly as a function of joint angle showed consistently that spastic knee flexor muscles produce a low percentage of their maximum force in flexed knee positions. They also showed effects of epimuscular myofascial force transmission (EMFT): simultaneous activation of different muscles elevated target muscle's force. However, quantification of spastic muscle's force - muscle-tendon unit length (l. MTU. ) data during gait is lacking. Aim. Combining intraoperative experiments with participants’ musculoskeletal models developed based on their gait analyses, we aimed to test the following hypotheses: activated spastic semitendinosus (ST) muscle (1) operates at short l. MTU. 's during gait, forces are (2) low at short l. MTU. 's and (3) increase by co-activating other muscles. Methods. Ten limbs of seven children with CP (GMFCS-II) were tested. Pre-surgery, gait analyses were conducted. Intraoperatively, isometric spastic ST distal forces were measured in ten hip-knee joint angle combinations, in two conditions: (i) activation of the ST individually and (ii) simultaneously with the gracilis, biceps femoris, and rectus femoris muscles endorsing EMFT. In OpenSim, gait_2392 model was used for each limb to (a) calculate l. MTU. per each hip and knee angle combination and the gait relevant l. MTU. range, and (b) analyze gait relevant spastic muscle force - l. MTU. data. Two-way ANOVA was used to compare the patients’ l. MTU. to those of the seven age-matched typically developing (TD) children. l. MTU. values were normalized for the participants’ thigh length. (a) was used to test hypothesis (1) and (b) to test hypotheses (2) and (3): in condition (i), the percent of peak force exerted at the shortest l. MTU. calculated per limb was used as a metric for (2). In condition (ii), mean percent change in muscle force calculated within gait-relevant l. MTU. range was used as a metric for (3). Results. Modeling showed that l. MTU. of spastic ST during gait is shorter on average by 14.1% compared to TD. The ST active force at the shortest gait-relevant l. MTU. was 68.6 (20.6)% (39.9–99.2%) of the peak force. Simultaneous activation of other muscles caused substantial increases in force (minimally by 11.1%, up to several folds, with an exception for one limb). Therefore, only the first and third hypotheses were confirmed. Conclusion. The modeling showed in concert with the clinical considerations that spastic ST may be a shortened muscle that produces high force in short muscle lengths. However, this contrasts intraoperative data, which shows only low forces in flexed knee positions. Note that, the model does not distinguish the muscle-belly and tendon lengths. Therefore, it cannot isolate shorter muscle length and how this compares to the data of TD children remains unknown. Yet, the effects of co-activation of other muscles shown intraoperatively to cause an increase of the spastic ST's force are observed also in muscle force - l. MTU. data characterizing gait. Therefore, if indeed spastic ST produces high forces in short muscle-belly lengths alone, elevated forces due to co-activation of other muscles may be considered as a contributor to the patients’ pathological gait. Otherwise, such EMFT effect may be the main determinant of the pathological condition


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 78 - 78
1 May 2012
Morris RG Lawson SEM
Full Access

Osteoarthritis is a joint condition affecting an estimated eight million people in the UK. The kinematics of walking and the impact experienced are thought to play an important role in the initiation and progression of the disease. Previous studies have looked the effect of osteoarthritis on the kinematics of walking in a laboratory environment. This work is part of the Newcastle Thousand Families Study which has followed a cohort of 1142 members since birth in 1947. Optoelectronic gait analysis methods are unsuitable for this environment, so inertial measurement units are being used. This study focuses on the validation of a protocol using inertial sensors to assess gait in the clinical environment. The sensors measure orientation in three dimensions. Our hypothesis was that an attachment position that minimises the movement of the sensor relative to the segment during gait was more important than the proximity of the sensor to anatomical landmarks. The effect of sampling rate, fatty tissue movement and material type were also tested Seven sensors (Xsens, Netherlands) were attached to participants on top of the foot, on the tibial plateau, on the lateral surface of the femur 10cm proximal to the lateral epicondyle, and over the sacrum. Attachment is by Velcro straps over the top of clothing for the waist, thigh and shank sensors, and with double-sided hypoallergenic tape on the foot. Four calibration movements are performed followed by a walking trial of ten paces down a corridor at a self-selected speed. Data is recorded wirelessly at a sampling rate of 50Hz. The calibration movements and trials are repeated twice and the time taken is 20 minutes. Measurement of the joint angles in the sagittal plane was used to assess the effect of changing the sensor position, simulating fatty tissue movement, and variation of material type underneath the sensor. The foot and thigh sensors were displaced in the distal direction by up to 10cm, the shank and waist sensors were displaced in the proximal direction by 5cm. Material types of different elasticity were tested. Fatty tissue movement beneath the straps was simulated using hydration gel packs. Each attachment scenario was repeated five times on a single subject. A “normal” attachment scenario was used to establish a baseline for repeatability of hip, knee and ankle angle measurement (mean±standard deviation of 49±1.28°, 61.5±1.28° and 33.5±0.69° respectively). Repeatability is comparable to that reported for an opto-electronic system (45±1.8°, 63±1.9° and 36±1.5°). Displacement of the foot, shank and waist sensors had no effect on the repeatability. Displacement of the thigh sensor decreased the repeatability for the knee and hip joint angles (52±3.22° and 62.5±2.91°). As the thigh sensor moved closer to the knee the movement artefact experienced increased. Altering sampling rate and simulated fatty tissue did not decrease repeatability. Of the materials tested, denim had the greatest affect, decreasing hip and knee angle repeatability (50.0±2.04° and 61.0±1.75°). A sensor attachment position that minimises sensor movement relative to the segment has been shown to produce the greatest repeatability, irrespective of their proximity to bony landmarks. This is particularly true for the femur sensor


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 72 - 72
1 Nov 2018
Lipperts M Gotink F van der Weegen W Theunissen K Meijer K Grimm B
Full Access

3D measurement of joint angles so far has only been possible using marker-based movement analysis, and therefore has not been applied in (larger scale) clinical practice (performance test) and even less so in the free field (activity monitoring). 3D joint angles could provide useful additional information in assessing the risk of anterior cruciate ligament injury using a vertical drop jump or in assessing knee range of motion after total knee arthroplasty. We developed a tool to measure dynamic 3D joint angles using 6 inertial sensors, attached to left and right shank, thigh and pelvis. The same sensors have been used for activity identification in a previous study. To validate the setup in a pilot study, we measured 3D knee and hip angles using the sensors and a Vicon movement lab simultaneously in 3 subjects. Subjects performed drop jumps, squats and ran on the spot. The mean error between Vicon and sensor measurement for the maximum joint angles was 3, 7 and 8 degrees for knee flexion, ad/abduction and rotation respectively, and 9, 7 and 10 degrees for hip flexion, ad/abduction and rotation respectively. No calibration movements were required. A major part of the inaccuracy was caused by soft tissue effects and can partly be resolved by improved sensor attachment. These pilot results show that it is feasible to measure 3D joint angles continuously using unobtrusive light-weight sensors. No movement lab is necessary and therefore the measurements can be done in a free field setting, e.g. at home or during training at a sport club. A more extensive validation study will be performed in the near future