TREATMENT OF VERY LARGE TRAUMATIC BONE DEFECTS WITH A BIODEGRADABLE POLYCAPROLACTONE-TRICALCIUM PHOSPHATE 3D-PRINTED SCAFFOLD: A REVIEW OF THREE CLINICAL CASES

The International Combined Orthopaedic Research Societies (ICORS), World Congress of Orthopaedic Research, Edinburgh, Scotland, 7–9 September 2022. Part 3 of 3.



Abstract

The need for an artificial scaffold in very large bone defects is clear, not only to limit the risk of graft harvesting, but also to improve clinical success. The use of custom osteoconductive scaffolds made from biodegradable polyester and ceramics can be a valuable patient friendly option, especially in case of a concomitant infection.

Multiple types of scaffolds for the Masquelet procedure (MP) are available, however these frequently demonstrate central graft involution when defects exceed a certain size and the complication rates remains high. This paper describes three infected tibial defect nonunions with a segmental defect over ten centimeters long treated with a customized 3D printed polycaprolactone-tricalcium phosphate (PCL-TCP) cage in combination with biological adjuncts.

Three male patients, between the age of 37 and 47, were treated for an infected tibial defect nonunion after sustaining Gustilo grade 3 open fractures. All had a segmental midshaft bone defect of more than ten centimeters (range 11–15cm). First stage MPs consisted of extensive debridement, external fixation and placement of anterior lateral thigh flaps (ALT). Positive cultures were obtained from all patients during this first stage, that were treated with specific systemic antibiotics during 12 weeks. The second stage MP was carried out at least two months after the first stage. CT scans were obtained after the first stage to manufacture defect-specific cages. In the final procedure a custom 3D printed PCL-TCP cage (Osteopore, Singapore) was placed in the defect in combination with biological adjuncts (BMAC, RIA derived autograft, iFactor and BioActive Glass). Bridging of the defect, assessed at six months by CT, was achieved in all cases. SPECT-scans 6 months post-operatively demonstrated active bone regeneration, also involving the central part of the scaffold. All three patients regained function and reported less pain with full weight-bearing.

This case report shows that 3D printed PCL-TCP cages in combination with biological adjuncts is a novel addition to the surgical treatment of very large bone defects in (infected) posttraumatic nonunion of the tibia. This combination could overcome some of the current drawbacks in this challenging indication.