Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 23 - 23
4 Apr 2023
Stoffel K Zderic I Pastor T Woodburn W Castle R Penman J Saura-Sanchez E Gueorguiev B Sommer C
Full Access

Treatment of simple and complex patella fractures represents a challenging clinical problem. Controversy exists regarding the most appropriate fixation method. Tension band wiring, aiming to convert the pulling forces on the anterior aspect of the patella into compression forces across the fracture site, is the standard of care, however, it is associated with high complication rates. Recently, anterior variable-angle locking plates have been developed for treatment of simple and comminuted patella fractures. The aim of this study was to investigate the biomechanical performance of the novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Sixteen pairs of human cadaveric knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or an anterior variable-angle locking core plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or an anterior variable-angle locking three-hole plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range from 90° flexion to full knee extension. Interfragmentary movements were captured by motion tracking. For both fracture types, the articular displacements, measured between the proximal and distal fragments at the central aspect of the patella between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the anterior variable-angle locked plating compared with the tension band wiring, p < 0.01. From a biomechanical perspective, anterior locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 56 - 56
2 Jan 2024
Zderic I Warner S Stoffel K Woodburn W Castle R Penman J Saura-Sanchez E Helfet D Gueorguiev B Sommer C
Full Access

Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34C1 or five-part complex AO/OTA 34C3 patella fractures by means of osteotomies, with each fracture model created in six pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full knee extension. Interfragmentary movements were captured via motion tracking. For both fracture types, the longitudinal and shear articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p<0.01. Lateral rim locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading


Introduction:

Mayo 2A Olecranon fractures are traditionally managed with a tension band wire device (TBW) but locking plates may also be used to treat these injuries.

Objectives:

To compare clinical outcomes and treatment cost between TBW and locking plate fixation in Mayo 2A fractures.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 29 - 29
17 Nov 2023
Morris T Dixon J Baldock T Eardley W
Full Access

Abstract. Objectives. The outcomes from patella fracture have remained dissatisfactory despite advances in treatment, especially from operative fixation1. Frequently, reoperation is required following open reduction and internal fixation (ORIF) of the patella due to prominent hardware since the standard technique for patella ORIF is tension band wiring (TBW) which inevitably leaves a bulky knot and irritates soft tissue given the patella's superficial position2. We performed a systematic review to determine the optimal treatment of patella fractures in the poor host. Methods. Three databases (EMBASE/Medline, ProQuest and PubMed) and one register (Cochrane CENTRAL) were searched. 476 records were identified and duplicates removed. 88 records progressed to abstract screening and 73 were excluded. Following review of complete references, 8 studies were deemed eligible. Results. Complication rates were shown to be high in our systematic review. Over one-fifth of patients require re-operation, predominantly for removal of symptomatic for failed hardware. Average infection rate was 11.95% which is higher than rates reported in the literature for better hosts. Nevertheless, reported mortality was low at 0.8% and thromboembolic events only occurred in 2% of patients. Average range of movement achieved following operative fixation was approximately 124 degrees. Upon further literature review, novel non-operative treatment options have shown acceptable results in low-demand patients, including abandoning weight-bearing restrictions altogether and non-operatively treating patients with fracture gaps greater than 1cm. Regarding operative management, suture/cable TBW has been investigated as a viable option with good results in recent years since the materials used show comparable biomechanics to stainless steel. Additionally, ORIF with locking plates have shown favourable results and have enabled aggressive post-operative rehabilitation protocols. TBW with metallic implants has shown higher complication rates, especially for anterior knee pain, reoperation and poor functional outcomes. Conclusion. There is sparse literature regarding patella fracture in the poor host. Nevertheless, it is clear that ORIF produces better outcomes than conservative treatment but the optimal technique for patella ORIF remains unclear. TBW with metallic implants should not remain the standard technique for ORIF; low-profile plates of suture TBW are more attractive solutions. Non-operative treatment may be considered for low-demand individuals however any form of patellectomy should be avoided if possible. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 40 - 40
1 Aug 2013
Spence S Shaw C Badhesha J Clark A Ayana G
Full Access

Olecranon fractures account for 20% of elbow fractures. Displaced fractures can be treated by several methods – Tension Band Wiring (TBW), Open Reduction and Internal Fixation with a plate (ORIF) or conservative measures. Studies from UK specialist centres have demonstrated infection rates of up to 15% and metal ware removal rates of up to 80%. In addition studies have shown that conservative treatment provides a good function and pain relief in the elderly and infirm. We aimed to look at all displaced olecranon fractures within our unit over a 4 year period and analyse their case notes for patient features, age stratification, treatment methods, complications and outcomes. We also aimed to compare our results to outcomes in studies published by specialist centres. All olecranon fractures admitted to our unit in calendar years 2007–2010 were identified from our trauma database. Case sheets were analysed for patient's age, co-morbidities, treatment, complications and outcome. X-rays were analysed to classify the fractures and assess outcome of treatment. 71 patients were identified, Male: Female = 33:38. Age range was 7–93, mean was 62.8 years. Treatment used – TBW 42 (59.1%), ORIF 9 (12.7%), and Conservative 20 (28.2%). In the surgical group of 51 patients there were 4 infections (7.8%). There were no incidences of nerve palsy. Metalware was removed in 15 patients (29.4%) – for TBW this was 11/42 (26.25%) and ORIF 4/9 (44.4%) – however the difference was not significant (p=0.06). The conservative group had no complications. In our study group we have demonstrated a lower infection rate and a far lower rate of metal ware removal than published studies. We have a high rate of patients treated conservatively who do well. Further work is being performed into the functional outcome of the whole group


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 6 - 6
1 Aug 2013
Shaw C Badhesha J Clark A Spence S Ayana G
Full Access

Olecranon fractures account for 20% of elbow fractures. Displaced fractures can be treated by several methods – Tension Band Wiring (TBW), Open Reduction and Internal Fixation with a plate (ORIF) or conservative measures. Studies from UK specialist centres have demonstrated infection rates of up to 15% and metalware removal rates of up to 80%. In addition studies have shown that conservative treatment provides good function and pain relief in the elderly and infirm. To look at all displaced olecranon fractures within our unit (the busiest district general hospital in Scotland) over a 4 year period and analyse for patient features, age stratification, identify treatment methods, complications and outcomes. To compare this to outcomes in studies published by specialist centres. All olecranon fractures admitted to our unit in calendar years 2007–2010 were identified from our trauma database. Case sheets were analysed for patient's age, co-morbidities, treatment, complications & outcome. Xrays were analysed to classify the fractures and assess outcome of treatment. 71 patients were identified, Male: Female = 33:38. Age range was 7–93. Mean 62.8. Treatment used – TBW 42 (59.1%), ORIF 9 (12.7%), Conservative 20 (28.2%). In the surgical group of 51 patients there were 4 infections (7.8%). There were no incidences of nerve palsy. Metalware was removed in 15 patients (29.4%) – for TBW this was 11/42 (26.25) and ORIF 4/9 (44.4%) – however the difference was not significant (p=0.06). The conservative group had no complications. In our study group we have demonstrated a lower infection rate and a far lower rate of metalware removal than published studies.?We have a high rate of patients treated conservatively who do well. Further work is being performed into the functional outcome of the whole group