The purpose of this study is to assess the long term results of combined ACL reconstruction and unicompartmental knee replacements (UKR). These patients have been selected for this combined operation due to their combination of instability symptoms from an absent ACL and unicompartmental arthritis. Retrospective review of 44 combined UKR and ACL reconstruction by a single surgeon. Surgeries included both medial and lateral UKR combined with either revision ACL reconstruction or primary ACL reconstruction. Patient reported outcomes were obtained preoperatively, at one year, 5 years and 10 years. Revision rate was followed up over 13 years for a mean of 7.4 years post-surgery. The average Oxford score at one year was 43 with an average increase from pre-operation to 1 year post operation of 15. For the 7 patients with 10 year follow up average oxford score was 42 at 1 year, 43 at 5 years and 45 at 10 years. There were 5 reoperations. 2 for revision to total knee arthroplasty and 1 for an exchange of bearing due to wear. The other 2 were the addition of another UKR. For those requiring reoperation the average time was 8 years. Younger more active patients presenting with ACL deficiency causing instability and unicompartmental arthritis are a difficult group to manage. Combining UKR and ACL reconstruction has scant evidence in regard to long term follow up but is a viable option for this select group. This paper has one of the largest cohorts with a reasonable follow up averaging 7.4 years and a revision rate of 11 percent. Combined unilateral knee replacements and ACL reconstruction can be a successful operation for patients with ACL rupture causing instability and unicompartmental arthritis.
Glenoid exposure is the name of the game in total shoulder arthroplasty. I can honestly say that it took me more than 5 years but less than 10 to feel confident exposing any glenoid, regardless of the degree of bone deformity and the severity of soft-tissue contracture. This lecture represents the synthesis of my experience exposing some of the most difficult glenoids. The basic principles are performing extensive soft-tissue release, minimizing the anteroposterior dimension of the humerus by osteophyte excision, making an accurate humeral neck cut, having a plethora of glenoid retractors, and knowing where to place them. The
Adequate fixation of implant components is an important goal for all arthroplasty procedures. Aseptic loosening is one of the leading causes of revision surgery in total knee arthroplasty. Radiostereometric analysis (RSA) is an imaging technique to measure implant migration, with established migration thresholds for well-fixed, at risk, and unacceptably migrating components. The purpose of the present study was to examine the long-term fixation of a cemented titanium fixed bearing polished tibial baseplate. Patients enrolled in a previous two-year prospective trial were recalled at
Introduction. Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of
Aim. There is a constant increase of joint arthroplasties to improve the quality of life of an aging population. Prosthetic-joint infections are rare, with an incidence of 1–2%, but they represent serious complications in terms of morbidity and mortality. The mortality was known to be approaching 8% in the elderly. The aim of this retrospective study is to reassess the two-year mortality rate over the last
Glenoid exposure is the name of the game in total shoulder arthroplasty. I can honestly say that it took me more than 5 years but less than 10 to feel confident exposing any glenoid, regardless of the degree of bone deformity and the severity of soft-tissue contracture. This lecture represents the synthesis of my experience exposing some of the most difficult glenoids. The basic principles are performing extensive soft-tissue release, minimizing the anteroposterior dimension of the humerus by osteophyte excision, making an accurate humeral neck cut, having a plethora of glenoid retractors, and knowing where to place them. The
In Two-Stage Revision, utilizing temporary antibiotic spacers is widely accepted. These spacers are available prefabricated or can be individually moulded intraoperatively. In this study, we analysed the efficacy of prefabricated and individual spacers in infection eradication of periprosthetic joint infection in knee and hip arthroplasties. All spacers implanted at a tertiary academic center during two-stage exchanges between June 2010 and December 2019 were retrospectively analysed. Among 249 patients, 167 cases (minimum follow-up ≥ 12 months) were included. Commercial spacers contained vancomycin and gentamycin, while individual spacers contained vancomycin alone. Subgroup analysis by manufacturers was conducted using non-parametric methods including Mann-Whitney U and Kruskal-Wallis tests. Survival analysis utilized Kaplan-Meier curves, and categorical data were analyzed using the Chi² test. Statistical significance was defined as p < 0.05.Aim
Method
Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability. This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; SERF, DÉCINES-CHARPIEU, FRANCE) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation. With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients. The use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years. That's why we also recommend DM cup for all high risk of dislocation situations.
Total knee replacement (TKA) surgery is an excellent and well-proven procedure for the treatment of end stage arthritis of the knee. Many refinements have taken place over time in an attempt to improve the components, wear qualities of the polyethylene, and the surgical technique to improve accuracy of component positioning, reduce patient pain, improve postoperative range of motion, ultimately improve results and to prolong the time until revision surgery may occur. This study examines the results of a gap balancing surgical technique in which components were implanted that had a posterior cruciate substituting design. This technique is performed with exacting alignment and balancing of the flexion and extension gaps prior to implantation of the knee components. The follow up is at a minimum of
Aim. There is a constant increase of total joint arthroplasties to improve the quality of life of an aging population. Prosthetic-joint infections are rare, with an incidence of 1–2%, but they represent serious complications in terms of morbidity and mortality. Different therapeutic options exist, but their management is still poorly standardized because of the lack of data from randomized trials. The aim of this retrospective study is to assess the infection eradication success rate, over the last
Anterior cruciate ligament (ACL) reconstruction is a commonly performed operation. A variety of graft options are used with the most popular being bone-patellar-tendon-bone and hamstring autograft. There has been an increase in the popularity of hamstring autograft over the past decade. The aim of the study was to assess the
Introduction. Despite being from different manufacturers, Exeter stem and Ogee cup are commonly used together as cemented ‘cross breed’ combination in United Kingdom. The purpose of this study was to evaluate the long-term outcome of this combination. Materials and methods. The
The robotic-assisted system (ROBODOC) is the first active robot that was designed to reduce potential human errors in performing cementless total hip arthroplasty (THA). We have reported minimum five years follow-up clinical results. However, to our knowledge, there have been no longer follow-up reports. The purpose of this study was to prospectively compare the minimum
BACKGROUND. Despite many years of clinical experience the optimal bearing choice in total hip arthroplasty (THA) remains controversial. This study aims to directly compare the three widely used bearing surfaces: metal-on-highly crosslinked polyethylene (MoHXLPE), ceramic-on-ceramic (CoC) and metal-on-metal (MoM), regarding clinical and radiologic outcome parameters. METHODS. From November 1999 to November 2001, 300 primary THAs were performed using the uncemented Alloclassic Variall cup and stem (Zimmer Inc., Warsaw, Indiana). The patients were divided into three groups according to the bearing couple implanted, with 100 persons in each group (MoHXLPE, CoC, MoM). Radiographic and clinical data was collected preoperative and at the last follow-up. RESULTS. There were 71 patients (74hips) in the MoHXLPE group, 63 patients (67hips) in the CoC group and 67 patients (69hips) in the MoM group available at the time of the last follow-up. Average follow-up was 10.4 years (MoHXLPE: 10.4, CoC: 10.5, MoM: 10.3). In the MoHXLPE and the CoC group 3 hips each had to undergo revision surgery. In the MoM group 4 hips were revised. Overall survival with revision for any reason as the end point was 95.9% for MoHXLPE, 95.5% for CoC and 94.2% for MoM. The mean Harris Hip Score (HHS) for patients who were not revised was 92.5 points, 92.3 points and 94.3 points at the last follow-up, for the MoHXLPE, CoC and MoM group respectively. Radiolucent lines around the stem in Gruen zones one and/or seven occurred in 17% to 27% of THAs in the three groups without clinical relevance. CONCLUSIONS. This study shows excellent results of all three bearing couples after
Introduction. Acetabular fractures are a challenging problem. It has been published that outcome is dependent upon the type of fracture, the reduction of the fracture and concomitant injuries. The end-points of poor outcome include avascular necrosis of the femoral head, osteoarthritis. However, we lack definitive statistics and so counselling patients on prognosis could be improved. In order to achieve this, more outcome studies from tertiary referral centres are required. We present the first long term follow up from a large tertiary referral Centre in Ireland. Methods. We identified all patients who were
Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate. The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute. We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1998 and 2008. Eighty-nine were revised due to recurrent dislocations, 11 for pseudotumor with dysfunctional abductors, and 13 for periprosthetic infection with loss of soft tissue stabilizers. All patients had revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 had more than 3 revisions. We extracted demographics, implant data, rate of dislocations and incidence of other complications. Kaplan Meier curves were used to assess dislocation and failure for any reason. WOMAC was used to assess quality of life. At 10 years, the survival free of dislocation was 95.6% (95%CI 90- 98), and at 20 years to 90.6% (95% CI 81- 95.5). Eight patients (7.1%) had dislocations of their constrained liners: 1 patient had simultaneous periprosthetic infection identified at the time of open reduction, and 1 patient sustained stem fracture 3 months prior to the liner dislocation. At 10 years, the survival to any further surgery was 89.4% (95% CI 82–93.8), and at 20 years, this was 82.5 (95% CI 71.9–89.3). Five patients (4.4%) had deep infection: 4 of these had excision arthroplasty due to failure to control infection, while 1 patient was treated successfully with debridement, exchange of mobile components and intravenous antibiotics. Two patients (1.8%) had dissociated rings that required change of liner, ring and head. Two patients (1.8%) had periprosthetic femoral fractures that were treated by revision stems and exchange of constrained liners. The mean WOMAC functional and pain scores were 66.2 and 75.9 of 100, respectively. Constrained tripolar liners in our institute provided favourable results in the long term for recurrent dislocation hip arthroplasty with dysfunctional hip stabilizers. Infection in these patients can prove to be difficult to treat due to their poor soft tissue conditions from repeated surgeries. Comparing long terms results from other types of constrained liners is essential to evaluate these salvage liners.
Long term results of Total Hip Arthroplasty (THA) are affected by wear of articulation. Ceramic on ceramic articulation have been used especially for young patients because of its low wear and bio-inert property. However, because of its hardness, it is concerned that ceramic fracture, chipping, or squeaking might happen with ceramic on ceramic articulation. The purpose of this study was to investigate over 10-years clinical and radiographic results of ceramic bearing cementless THA.Introduction
Objective
Introduction. The correction of paediatric scoliosis is a surgical procedure in which substantial bleeding occurs, and which historically has been associated with high levels of blood transfusion. Transfusions are associated with risks of infection, allergic reactions, volume overload and immunosuppression. The purpose of our study was to evaluate the efficacy of a care pathway implemented at St Thomas' hospital over
INTRODUCTION. Despite a large percentage of total knee arthroplasty failures occurs for disorders at the patello-femoral joint (PFJ), current navigation systems report tibio-femoral (TFJ) kinematics only, and do not track the patella. Despite this tracking is made difficult by the small bone and by its full eversion during surgery, a new such technique has been developed, which includes a new tracker, new corresponding surgical instrumentation also for patellar resurfacing, and all relevant software. The aim of this study is to report an early experience in patients of these measurements, i.e. TFJ and PFJ kinematics. METHODS. These measurements were taken in the first
Background. Autologous chondrocyte implantation (ACI) and mosaicplasty (MP) are two methods of repair of symptomatic articular cartilage defects in the adult knee. This study represents the only long-term comparative clinical trial of the two methods. Methods. A prospective, randomised comparison of the two modalities involving 100 patients with symptomatic articular cartilage lesions was undertaken. Patients were followed for