Abstract
Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability.
This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; SERF, DÉCINES-CHARPIEU, FRANCE) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation.
With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients.
The use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years. That's why we also recommend DM cup for all high risk of dislocation situations.