Ulnar
Introduction. Ulnar
Background. Total hip arthroplasty for Crowe type IV developmental dysplasia of the hip is a technically demanding procedure. Restoration of the anatomical hip center frequently requires limb lengthening in excess of 4 cm and increases the risk of neurologic traction injury. However, it can be difficult to predict potential leg length change, especially in total hip arthroplasty for Crowe type IV developmental hip dysplasia. The purpose of the present study was to better define features that might aid in the preoperative prediction of leg length change in THAs with subtrochanteric femoral
Aim. To assess the survivorship of a tapered fluted Titanium monoblock stem in conjunction with subtrochanteric shortening for patients with High Dislocation performed at 2 centres. Methods. This was a retrospective study of 84 hips in 52 patients between two centres. All patients had a high dislocation. Thirty five patients had bilateral dysplasia. All patients had total hip arthroplasty with a subtrochanteric
Background. There are many difficulties during performing total hip replacement in high riding DDH. These difficulties include:. In Acetabular part: bony defect in antero lateral acetabular wall/finding true centre of rotation/shallowness of true acetabulum/hypertrophied and thick capsular obstacle between true and false acetabulum. In Femoral part: small diameter femoral shaft/excessive ante version/posterior placement of greater trochanter. anatomic changes in soft tissue & neurovascular around the hip including: adductor muscle contracture/shortening of abductor muscles/risk of sciatic nerve injury following lengthening of the limb after reduction in true acetabulum/vascular injury. The purpose of this lecture is how to manage above problems with using reinforcement ring (ARR) for reconstruction of true acetabulum and step cut L fashion proximal femoral neck
Introduction. The anatomic abnormalities associated with the dysplastic hip increase the complexity of hip arthroplasty, in addition previous femural osteotomy can deformate proximal femur. Despite the fact that uncemented cup and stems are specifically designed for dysplasia to recover the true acetabular region in Crowe IV and sometimes Crowe III additional surgical procedure are required. Purpose of the study is to verify surgical procedures and explore reconstruction options on severe hip dysplasia. Materials and methods. In last 25 years, 2308 arthroplasties were performed in dysplastic hips (565 cases had a previous femoral osteotomy). In 128 cases was required a correction of femoral side deformity: in 64 cases was performed a greater trochanter osteotomy (in 12 of these a proximal femoral shortening was associated), 55 cases were treated by a
Restoration of an anatomical hip centre frequently requires limb lengthening, which increases the risk of nerve injury in the treatment of Crowe 4 DDH. The objective was to perform a prospective evaluation of SDTSO with Cemented Exeter Femoral Component. 15 female patients (18 hips – 3 bilateral) with a mean age at time of operation of 51 years were followed-up for a mean of 77 months (11 to 133). 16 cemented and 2 uncemented acetabular components were implanted. Exeter cemented DDH stems were used in all cases. No patient was lost to follow-up. Charnley-d'Aubigné-Postel scores for pain, function and range of movement were improved from a mean of 2, 2, 3 to 5, 4, 5 respectively. One osteotomy failed to unite at 14 months and was revised successfully. Clinical healing was achieved at a mean of 6 months and radiological at a mean of 9 months. The mean length of the excised segment was 3cm and the mean true limb lengthening was 2cm. A 3.5mm DCP plate with unicortical screws was used to reduce the osteotomy, and intramedullary autografting was performed in all cases. Mean subsidence was 1mm and no stem was found loose at the latest follow-up. No sciatic nerve palsy was observed and no dislocation. Cemented Exeter femoral components perform well in the treatment of Crowe IV DDH with SDTSO. Transverse osteotomy is necessary to achieve derotation and reduction can be maintained with a DCP plate. Intramedullary autografting prevents cement interposition at the osteotomy site.
Introduction. In DDH cases often have high anteversion. They also often have high hip center. THA for those cases sometimes requires subtrochanteric derotational/
Introduction. The anatomic abnormalities are observed in developmental dysplasia of the hip (DDH) and it is challenging to perform the total hip arthroplasty (THA) for some DDH patients. If acetabular cup was placed at the original acetabular position in patients with high hip dislocation, it may be difficult to perform reduction of hip prosthesis because of soft tissue contracture. The procedures resolving this problem were to use femoral
Introduction. Femoral-shortening osteotomy for the treatment of leg length discrepancy is demanding technique. Many surgical technique and orthopaedic devises have been suggested to perform this procedure. Herein, we describe modified femoral
Essex-Lopresti injuries are often unrecognized acutely with resulting debilitating adverse effects. Persistent axial forearm instability may affect load transmission at both the elbow and wrist, resulting in significant pain. In the setting of both acute and chronic injuries metallic radial head arthroplasty has been advocated, however there is little information regarding their outcome. The purpose of this study was to assess the efficacy of a radial head arthroplasty to address both acute and chronic Essex-Lopresti type injuries. A retrospective review from 2006 to 2016 identified 11 Essex-Lopresti type injuries at a mean follow-up of 18 months. Five were diagnosed and treated acutely at a mean of 11 days (range, 8 to 19 days) from injury, while 6 were treated in a delayed fashion at a mean of 1.9 years (range, 2.7 months to 6.2 years) from injury with a mean 1.5 (range, 0 to 4) prior procedures. The cohort included 10 males with a mean age was 44.5 years (range, 28 to 71 years). A smooth stem, modular radial head arthroplasty was used in all cases. Outcomes included range of motion and radiographic findings such as ulnar variance, capitellar erosion, implant positioning and implant lucency using a modification of the method described by Gruen. Reoperations, including the need for ulnar
Introduction. The project of a modular, double-conicity stem is born from the need to obtain primary stability and correct osseointegration in patients with developmental hip dysplasia, or proximal femoral dysmorphisms requiring a femoral
Ulnocarpal impaction (UCI) is a common cause of ulnar-sided wrist pain. UCI typically occurs in wrists with positive ulnar variance, which causes altered loading mechanics between the ulnar head, lunate and triquetrum. However, many individuals with positive ulnar variance never develop UCI, and some with neutral or negative ulnar variance do experience UCI. This suggests that other variables contribute to the development of UCI. Suspected culprits include lunate morphology, and dynamic changes with loaded (grip) pronation. If these anatomic variations are contributing to UCI, we expect them to influence functional impairment scores. Therefore, the objective of this study was to evaluate the relationship between radiographic parameters and pre-surgical upper extremity patient-rated outcomes scores (PROS) in patients with a diagnosis of UCI. Retrospective cohort study of patients undergoing ulnar
Introduction. Corrective femoral osteotomy in adults, as a closed procedure with the use of an intramedullary saw, is an elegant, minimally invasive technique for the correction of lower limb length inequalities or problems of torsion. Stabilisation following the osteotomy was achieved with a cephalo-medullary nail. We report the indications, results and complications following use of this technique. Aim. The aim of the study was to review consecutive patients who underwent closed femoral rotational or
Intro. Sciatic nerve injury (SNI) is a rare and potentially devastating complication after total hip arthroplasty (THA). Neural monitoring has been found in several studies to be useful in preventing SNI, but can be difficult to practically implement during surgery. In this study, we examine the results of using a handheld nerve stimulator for intraoperative sciatic nerve monitoring during complex THA requiring limb lengthening and/or significant manipulation of the sciatic nerve. Methods. We retrospectively reviewed a consecutive series of 11 cases (9 patients, 11 hips) with either severe developmental dysplasia of the hip (Crowe 3–4) or other underlying conditions requiring complex hip reconstruction involving significant leg lengthening and/or nerve manipulation. Sciatic nerve function was monitored intra-operatively with a handheld nerve stimulator by obtaining pre- and post-reduction conduction thresholds during component trialling. The results of nerve stimulation were then used to influence intraoperative decision- making (downsizing components, shortening osteotomy). Results. No permanent postoperative sciatic nerve complication occurred, with an average increase of 28.5mm in limb length, ranging from 6 to 51mm. In 2 out of 11 cases, a change in nerve response was identified after trial reduction, which resulted in an alternate surgical plan (femoral
A study by Harris reported a 40% incidence of femoral and acetabular dysplasia in routine idiopathic osteoarthritic patients. Due to pediatric screening in the United States, today most cases are minimally dysplastic requiring little modification from standard total hip surgical techniques. As the degree of dysplasia increases numerous anatomic distortions are present. These include high hip centers, relative acetabular retroversion, soft bone in the true acetabular area, increased femoral neck anteversion and relative posteriorly positioned greater trochanters, metaphyseal/diaphyseal size mismatch, and small femoral canals. Total hip replacements for these patients have known higher risks for earlier loosening, dislocation, and neurovascular injuries. Use of medialised small uncemented acetabular components placed in the anatomic acetabulum, modular uncemented femoral components, and diaphyseal rotational and
Cementless femoral components have an excellent track record that includes efficient implantation and long-term survival, thus are the predominant stem utilised in North America. Femoral component stability and resistance to subsidence are critical for osseointegration and clinical success. Implant design, surgical technique, anatomic fit, and patient characteristics, such as bone quality, can all effect initial implant stability and resistance to subsidence. Variability in stem shape and in the anatomy of the proximal femoral metaphysis has been implicated in the failure of some stem designs. Biologic fixation obtained with osseointegration of cementless implants may improve implant longevity in young, active, and obese patients. Lack of intimate fit can lead to clinical complications such as subsidence, aseptic loosening, and peri-prosthetic fracture. Currently, there are several stem designs, all of which aim to achieve maximal femoral stability and minimal subsidence and include: Fit and Fill / Double Taper Proximally Porous Coated Stems; Parallel Sided Taper Wedge or “Blade” Stems; Wagner Style Conical Shape Splined Titanium Stems; Tapered Rectangular Cross-Section Zweymuller Stem; Fully-Porous Coated Stems; Modular Proximal Sleeve Fluted Stem; Anatomic Proximally Porous Coated Stems. The majority of patients with relatively straightforward anatomy can be treated with any of the aforementioned femoral implant types. However, more complicated femoral anatomy frequently requires a particular implant type to maximise stability and promote osseointegration. Stems with femoral deformity in the meta-diaphyseal region may require a shorter stem in order to avoid an osteotomy. Distorted femoral anatomy typically seen in childhood diseases, such as dysplasia, may require a modular proximal sleeve tapered fluted stem or Wagner style cone stem to impart optimal stem anteversion separate from the native femoral neck version. The most severe forms of dysplasia may require a
Purpose. We analyzed a consecutive series of 36 total hip arthroplasties using cementless conical stem with a
Introduction. Bulk bone grafting of the cup is commonly used in total hip arthroplasty (THA) for developmental dysplasia. However, it carries a risk of the graft collapse in the mid-term or long-term results. The purpose of this study is to describe our new bulk bone grafting technique and review the radiographic and clinical results. Patients and Methods. We retrospectively reviewed 85 hips in 74 patients who had undergone bulk bone grafting in total hip arthroplasty for developmental dysplasia between 2008 and 2013. We excluded patients who had any previous surgeries or performed THA with the femoral
In order to achieve a true AP and lateral radiograph of the wrist, there must be no movement at the radio-ulnar joint. Projections taken with only pronation and supination at the wrist provide two views of the radius but a single view of the ulna. True radiographs are achieved by rotating the humerus through 90 degrees and extending at the elbow between the two views. Our aim was to look at whether true lateral and AP radiographs are taken by our radiology department. Between April 2009 to November 2010, we identified all patients with ulna