Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 107 - 107
2 Jan 2024
Park H
Full Access

The rotator cuff tendinopathy is one of the most common shoulder problems leading to full-thickness rotator cuff tendon tear and, eventually, to degenerative arthritis. Recent research on rotator cuff tendon degeneration has focused on its relationship to cell death. The types of cell death known to be associated with rotator cuff tendon degeneration are apoptosis, necrosis, and autophagic cell death. The increased incidence of cell death in degenerative tendon tissue may affect the rates of collagen synthesis and repair, possibly weakening tendon tissue and increasing the risk of tendon rupture. The biomolecular mechanisms of the degenerative changes leading to apoptotic cell death in rotator cuff tenofibroblasts have been identified as oxidative-stress-related cascade mechanisms. Furthermore, apoptosis, necrosis, and autophagic cell death are all known to be mediated by oxidative stress, a condition in which ROS (reactive oxygen species) are overproduced. Lower levels of oxidative stress trigger apoptosis; higher levels mediate necrosis. Although the signaltransduction pathway leading to autophagy has not yet been fully established, ROS are known to be essential to autophagy. A neuronal theory regarding rotator cuff degeneration has been developed from the findings that glutamate, a neural transmitter, is present in increased concentrations in tendon tissues with tendinopathy and that it induces rat supraspinatus tendon cell death. Recent studies have reported that hypoxia involved in rotator cuff tendon degeneration. Because antioxidants are known to scavenge for intracellular ROS, some studies have been conducted to determine whether antioxidants can reduce cell death in rotator cuff tendon-origin fibroblasts. The first study reported that an antioxidant has the ability to reduce apoptosis in oxidative-stressed rotator cuff tenofibroblasts. The second study reported that antioxidants have both antiapoptotic effects and antinecrotic effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The third study reported that an antioxidant has antiautophagic-cell-death effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The fourth study reported that glutamate markedly increases cell death in rotator cuff tendonorigin fibroblasts. The glutamate-induced cytotoxic effects were reduced by an antioxidant, demonstrating its cytoprotective effects against glutamate-induced tenofibroblast cell death. The fifth study reported that hypoxia significantly increases intracellular ROS and apoptosis. The hypoxia-induced cytotoxic effects were markedly attenuated by antioxidants, demonstrating their cytoprotective effects against hypoxia-induced tenofibroblast cell death. In conclusion, antioxidants have cytoprotective effects on tenofibroblasts exposed in vitro to an oxidative stressor, a neurotransmitter, or hypoxia. These cytoprotective effects result from antiapoptotic, antinecrotic, and antiautophagic actions involving the inhibition of ROS formation. These findings suggest that antioxidants may have therapeutic potential for rotator cuff tendinopathy. Further studies must be conducted in order to apply these in vitro findings to clinical situations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 30 - 30
2 Jan 2024
Park H Kim R
Full Access

Glutamate regulates the expression of apoptosis-related genes and triggers the apoptosis of fibroblasts in rotator cuff tendons. Subacromial bursitis is always accompanied by symptomatic rotator cuff tear (RCT). However, no study has been reported on the presence of glutamate in subacromial bursa and on its involvement of shoulder pain in patients who had RCT. The purposes of this study were to determine whether the glutamate expression in subacromial bursa is associated with the presence of RCT and with the severity of shoulder pain accompanying RCT. Subacromial bursal tissues were harvested from patients who underwent arthroscopic rotator cuff tendon repair or glenoid labral repair with intact rotator cuff tendon. Glutamate tissue concentrations were measured, using a glutamate assay kit. Expressions of glutamate and its receptors in subacromial bursae were histologically determined. The sizes of RCT were determined by arthroscopic findings, using the DeOrio and Cofield classification. The severity of shoulder pain was determined, using visual analog scale (VAS). Any associations between glutamate concentrations and the size of RCT were evaluated, using logistic regression analysis. The correlation between glutamate concentrations and the severity of pain was determined, using the Pearson correlation coefficient. Differences with a probability <0.05 were considered statistically significant. Glutamate concentrations showed significant differences between the torn tendon group and the intact tendon group (P = 0.009). Concentrations of glutamate significantly increased according to increases in tear size (P < 0.001). In histological studies, the expressions of glutamate and of its ionotropic and metabotropic receptors have been confirmed in subacromial bursa. Glutamate concentrations were significantly correlated with pain on VAS (Rho=0.56 and P =0.01). The expression of glutamate in subacromial bursa is significantly associated with the presence of RCT and significantly correlated with its accompanying shoulder pain. Acknowledgements: This research was supported by the Basic Science Research Program, through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2015R1D1A3A01018955 and 2017R1D1A1B03035232)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 42 - 42
1 May 2012
Chaudhury S Holland C Porter D Vollrath F Carr AJ
Full Access

Background. High re-rupture rates following repairs of rotator cuff tears (RCTs) have resulted in the increased use of repair grafts to act as temporary scaffolds to support tendon healing. It has been estimated that thousands of extracellular matrix repair grafts are used annually to augment surgical repair of rotator cuff tears. The only mechanical assessment of the suitability of these grafts for rotator cuff repair has been made using tensile testing only, and compared grafts to canine infraspinatus. As the shoulder and rotator cuff tendons are exposed to shearing as well as uniaxial loading, we compared the response of repair grafts and human rotator cuff tendons to shearing mechanical stress. We used a novel technique to study material deformation, dynamic shear analysis (DSA). Methods. The shear properties of four RCT repair grafts were measured (Restore, GraftJacket, Zimmer Collagen Repair and SportsMesh). 3mm-sized biopsy samples were taken and subjected to DSA using oscillatory deformation under compression to calculate the storage modulus (G') as an indicator of mechanical integrity. To assess how well the repair grafts were matched to normal rotator cuff tendons, the storage modulus was calculated for 18 human rotator cuff specimens which were obtained from patients aged between 22 and 89 years (mean age 58.8 years, with 9 males and 9 females). Control human rotator cuff tendons were obtained from the edge of tendons during hemiarthoplasties and stabilisations. A 1-way ANOVA of all of the groups was performed to compare shear properties between the different commercially available repair grafts and human rotator cuff tendons to see if they were different. Specific comparison between the different repair grafts and normal rotator cuff tendons was done using a Dunn's multiple comparison test. Results. We report a significant difference in the shear moduli of all four rotator cuff repair grafts (P<0.0001, 1 way ANOVA, Kruskall-Wallis test). 2 of the grafts, Zimmer Collagen Repair and SportMesh, were not significantly different when compared to rotator cuff tendons and were found to have comparable shear mechanical properties (P > 0.05, Dunn's multiple comparison test). The other repair grafts, GraftJacket and Restore, had a significantly lower storage modulus when compared to human rotator cuff tendons. Conclusions. With increasing numbers of repairs of rotator cuff tears, and augmentation of these repairs, there is a need to understand the mechanical and biological properties of the both repair grafts and the tendons they are designed to augment. At present there is no clear definition of the ideal mechanobiological properties of rotator cuff repair patches. Current rotator cuff repair grafts display a wide variation in their shear mechanical properties, and how closely they are matched to the mechanical properties of human rotator cuff tendons. It is hoped that this study may help to guide surgeons in deciding on the most appropriate rotator cuff tendon repair graft


Bone & Joint Research
Vol. 3, Issue 8 | Pages 252 - 261
1 Aug 2014
Tilley JMR Murphy RJ Chaudhury S Czernuszka JT Carr AJ

Objectives . The effects of disease progression and common tendinopathy treatments on the tissue characteristics of human rotator cuff tendons have not previously been evaluated in detail owing to a lack of suitable sampling techniques. This study evaluated the structural characteristics of torn human supraspinatus tendons across the full disease spectrum, and the short-term effects of subacromial corticosteroid injections (SCIs) and subacromial decompression (SAD) surgery on these structural characteristics. . Methods . Samples were collected inter-operatively from supraspinatus tendons containing small, medium, large and massive full thickness tears (n = 33). Using a novel minimally invasive biopsy technique, paired samples were also collected from supraspinatus tendons containing partial thickness tears either before and seven weeks after subacromial SCI (n = 11), or before and seven weeks after SAD surgery (n = 14). Macroscopically normal subscapularis tendons of older patients (n = 5, mean age = 74.6 years) and supraspinatus tendons of younger patients (n = 16, mean age = 23.3) served as controls. Ultra- and micro-structural characteristics were assessed using atomic force microscopy and polarised light microscopy respectively. . Results. Significant structural differences existed between torn and control groups. Differences were identifiable early in the disease spectrum, and increased with increasing tear size. Neither SCI nor SAD surgery altered the structural properties of partially torn tendons seven weeks after treatment. . Conclusions . These findings may suggest the need for early clinical intervention strategies for torn rotator cuff tendons in order to prevent further degeneration of the tissue as tear size increases. Further work is required to establish the long-term abilities of SCI and SAD to prevent, and even reverse, such degeneration. Cite this article: Bone Joint Res 2014;3:252–61


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 32 - 32
2 Jan 2024
Traweger A
Full Access

Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing. Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator cuff tendon repair by modulating local inflammation and reduce fibrotic scarring. In another approach, we investigated if the local delivery of the tendon ECM protein SPARC, which we previously demonstrated to be essential for tendon maturation and tissue homeostasis, has the potential to enhance tendon healing. Finally, I will present results demonstrating the utility of nanoparticle-delivered, chemically modified mRNAs (cmRNA) to improve tendon repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 39 - 39
4 Apr 2023
Lim W Lie D Chou S Lie H Yew A
Full Access

This study aims to investigate the mechanical properties of a rotator cuff tear repaired with a polypropylene interposition graft in an ovine infraspinatus ex-vivo model. Twenty fresh shoulders from skeletally mature sheep were used in this study. A tear size of 20 mm from the tendon joint was created in the infraspinatus tendon to simulate a large tear in fifteen specimens. This was repaired with a polypropylene mesh used as an interposition graft between the ends of the tendon. Eight specimens were secured with mattress stitches while seven were secured to the remnant tendon on the greater tuberosity side by continuous stitching. Remaining five specimens with an intact tendon served as a control group. All specimens underwent cyclic loading with a universal testing machine to determine the ultimate failure load and gap distance. Gap distance increased with progressive cyclic loading through 3000 cycles for all repaired specimens. Mean gap distance after 3000 cycles for both continuous and mattress groups are 1.7 mm and 4.2 mm respectively (P = .001). Significantly higher mean ultimate failure load was also observed with 549.2 N in the continuous group, 426.6 N in the mattress group and 370 N in the intact group. The use of a polypropylene mesh as an interposition graft for large irreparable rotator cuff tears is biomechanically suitable and results in a robust repair that is comparable to an intact rotator cuff tendon. When paired with a continuous suturing technique, it demonstrates significantly resultant superior biomechanical properties that may potentially reduce re-tear rates after repairing large or massive rotator cuff tears


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 252 - 252
1 Jul 2014
Mouthuy P Hakimi O Baboldashti NZ Morrey M Lostis E Carr A
Full Access

Summary Statement. This study describes the design and preliminary in vitro testing of a novel patch for the repair of rotator cuff tendon tears. The laminated design incorporates woven and electrospun components. The woven element provides the patch with excellent mechanical strength and the electrospun layer improves cell attachment and promotes cell orientation and diferentiation. Introduction. Aligned nanofibrous electrospun scaffolds have been previously proposed as ideal scaffolds for tendon repair, replicating the anisotropy of tendon and providing a biomimetic design to encourage tissue regeneration (Hakimi et al., 2012). However, such scaffolds are still limited in terms of mechanical properties. This paper presents the design of a novel patch for rotator cuff repair in which the electrospun scaffold is supported by a woven component. Patients & Methods. Aligned polydioxanone (PDO) electrospun scaffolds were produced using a single nozzle electrospinning set-up with a rotating collector. The woven component was created by weaving PDO monofilaments with a manual loom. The woven and non-woven constituents were bound by a non-destructive method which preserves the surface morphology of the electrospun material. For each type of scaffold, a minimum of 3 specimens were tested to failure in tension using Zwick machine at rate of 0.3 mm/min until failure. For in vitro work, human-derived tendon cells were extracted from rotator cuff tendon tissue obtained during surgical repair, with appropriate ethical approval. Cells were cultured on the scaffolds for at least 14 days. Results. The contribution of the woven component to the tensile strength of the assembled patch is about 20 times more when compared to the electrospun scaffold. In vitro work shows that human tenocytes grown on the nanofibrous non-woven electrospun component align in the direction of the fibre orientation. The appearance of the woven component is shown. Discussion/Conclusion. While the woven component provides most of the mechanical strength, the aligned electrospun fibres enable cell orientation along the axis of the patch. These cells display a similar morphology to tenocytes in native tendons. With the combination of biomimetic features and good mechanical properties, this novel PDO patch is an excellent candidate material to support tendon repair


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 6 - 6
1 Dec 2022
Roversi G Nusiner F De Filippo F Rizzo A Colosio A Saccomanno M Milano G
Full Access

Recent studies on animal models focused on the effect of preserving tendon remnant of rotator cuff on tendon healing. A positive effect by combining tendon remnant preservation and small bone vents on the greater tuberosity in comparison with standard tendon-to-bone repair has been shown. The purpose of the present clinical study was to evaluate the efficacy of biologic augmentation of arthroscopic rotator cuff repair by maintaining tendon remnant on rotator cuff footprint combined with small bone vents of the greater tuberosity. A retrospective study was conducted. All patients who underwent arthroscopic rotator cuff repair associated with small bone vents (nanofractures) and tendon footprint preservation were considered eligible for the study. Inclusion criteria were: diagnosis of full-thickness rotator cuff tear as diagnosed at preoperative magnetic resonance imaging (MRI) and confirmed at the time of surgery; minimum 24-month of follow-up and availability of post-operative MRI performed not earlier than 6 months after surgery. Exclusion criteria were: partial thickness tears, irreparable tears, capsulo-labral pathologies, calcific tendonitis, gleno-humeral osteoarthritis and/or previous surgery. Primary outcome was the ASES score. Secondary outcomes were: Quick-DASH and WORC scores, and structural integrity of repaired tendons by magnetic resonance imaging (MRI) performed six months after surgery. A paired t-test was used to compare pre- and postoperative clinical outcomes. Subgroup analysis was performed according to tear size. Significance was set at p < 0.05. The study included 29 patients (M:F = 15:14). Mean age (+ SD) of patients was 61.7 + 8.9 years. Mean follow-up was 27.4 ± 2.3 months. Comparison between pre- and postoperative functional scores showed significant clinical improvement (p < 0.001). Subgroup analysis for tear size showed significant differences in the QuickDASH score (0.04). Particularly, a significant difference in the QuickDASH score could be detected between medium and large tears (p=0.008) as well as medium and massive lesions (p=0.04). No differences could be detected between large and massive tears (p= 0.35). Postoperative imaging showed healed tendons in 21 out of 29 (72%) cases. Preservation of tendon remnant combined with small bone vents in the repair of medium-to-massive full-thickness rotator cuff tears provided significant improvement in clinical outcome compared to baseline conditions with complete structural integrity in 72% of the cases


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2017
Chevalier Y Pietschmann M Thorwaechter C Chechik O Adar E Dekel A Mueller P
Full Access

Treatment of massive rotator cuff tears can be challenging. Previous studies with irreparable rotator cuff tears showed good clinical results of tendon healing with the arthroscopic insertion of a protective biodegradable spacer balloon filled with saline solution between the repaired tendon and the acromion [1,2], but so far no scientific evidence has showed how the device alters pressures over the repaired tendon. This biomechanical study investigated the effects of a spacer inserted in the subacromial space on pressures over the repaired rotator cuff tendon in passive motion cycles typical for post-operative rehabilitation routines. Six human cadaveric shoulders were prepared with the humerus cut 15cm below the joint and embedded in a pot, while the scapula fixed at three points on a plate. A rotator cuff tear was simulated and repaired using a suture anchor and a Mason-Allen suture. The specimens were then mounted on a custom-made pneumatic testing rig to induce passive motion cycles of adduction-abduction (90–0°) and flexion-extension (0–40°) with constant glenohumeral and superior loads and tension is exerted on the supraspinatus tendon with weights. A pressure sensor was placed between the supraspinatus tendon and the acromion. After pressure measurements for 15 cycles of each motion type, the InSpace balloon (OrthoSpace, Inc, Israel) was inserted and the specimens tested and pressure measured again for 15 cycles. Statistically significant changes in peak pressures were then measured before and after balloon. Peak pressures were measured near 90 degrees abduction. No statistical differences were observed for internal-external rotation before and after balloon-shaped subacromial spacer was inserted. Mean pressures in abduction-adduction were significantly reduced from 121.7 ± 9.5 MPa to 51.5 ± 1.2 MPa. Peak pressures after repair were 1171.3 ± 99.5 MPa and 1749.6 ± 80.7 MPa in flexion-extension and abduction-adduction motion, respectively, and significantly decreased to 468.7 ± 16.0 MPa and 535.1 ± 27.6 MPa after spacer insertion (p<0.0001). The use of the spacer above the repaired tendon reduced peak pressures and distributed them more widely over the sensor during both abduction-adduction and flexion-extension motions and therefore can reduce the stress on the rotator cuff repair. The InSpace system may reduce the pressure on the repaired tendon, thus potentially protecting the repair. Further studies to investigate this phenomenon are warranted, in particular relating these changes to shoulder kinematics following tear repair and spacer insertion


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2017
Wu J Zhou Z Zhao X Xue W Xu J Kirk T
Full Access

The health of a synovial joint is relied on normal function and coordination of a group of tissues such as articular cartilage (AC), ligaments, tendons and muscles. Osteoarthritis (OA), which is the most common joint disease, is clinically characterised by lesion of AC. Despite this, injury of a ligament or tendon or muscle generates a joint instability, which accelerates deterioration of AC and progression of OA. Traditional histology is often used to study the pathology of biological tissues. It requires tissue biopsy, which traumatises the donor tissues. Therefore, it is not an idea method for assessing AC, ligaments and tendons as the tissues have a poor healing capability. There is a worldwide demand of an imaging technique that diagnoses the microstructural changes of chondral and connective tissues without biopsy. Confocal arthroscopy (Optiscan Pty Ltd, Australia) possesses a Ø 6.3 mm probe and offers a 0.7 µm lateral imaging resolution and 7 µm axial resolution. It has been successfully used for examining the internal microstructural disorders in rotator cuff tendons of human cadavers without tissue biopsy (WU et al., 2015). This study investigates the capability of confocal arthroscopy as optical histology for assessing the internal microstructure of AC, ligaments, tendons and muscles in a knee joint. Four sheep keen joints were freshly donated by other research unrelated to this study. After 5 ml clinical grade fluorescein solution at 0.05 g/L was injected into the joint cavity of a knee joint, the joint was passively exercising for about 10 minutes. The joint was then open collaterally and washed thoroughly using PBS for acquiring the microstructure of AC, ligaments, tendons and muscles using the confocal arthroscopy. Results: without biopsy, confocal arthroscopy offers an imaging resolution for onsite distinguishing the subtle microstructural difference of AC in the weight-bearing and non-weight bearing region. It also permitted visualising the hierarchical collagen structure in ligaments and tendons at a fibre level, and characterising the muscle nuclei, motor-neurons, moto-neuron synapse and striates of myofibres. Confocal arthroscopy showed the early promise to act as optical histology for studying the microstructure of chondral and a range of connective tissues, which allows understand better the health status of a knee joint. Since a sheep knee joint is very small for operating a normal procedure of an arthroscopic examination, an open knee joint surgery was performed in this study to allow imaging the microstructure of AC and a range of connective tissues. This is accounted as a limitation in the study. Nevertheless, this study demonstrated the development of confocal arthroscopy may lead to optical histology of the internal microstructure of AC and a group of connective tissues, which offers understanding more comprehensively the healthy status of a knee joint


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 10 - 10
1 Apr 2012
Marsh A Fazzi U
Full Access

Massive, irreparable rotator cuff tears occur in about 15% of patients with ruptures of the rotator cuff tendons. There is no consistently agreed management for irreparable rotator cuff tears, however, latissimus dorsi tendon transfer is a recognised technique. We aimed to review the functional outcome of patients undergoing this operation at a single tertiary referral centre. Fourteen latissimus dorsi transfer procedures in thirteen patients from May 2007 to May 2008 were retrospectively reviewed. The mean age of patients undergoing the procedure was fifty nine years. All patients were confirmed to have massive, irreparable (>5cm) rotator cuff tears as determined by MRI or ultrasound. Modified Constant scores (assessing shoulder pain, functional activity and movement) determined pre-operatively and post latissmus dorsi transfer were compared. The mean duration of follow up was 12 months. The mean Modified Constant Score (maximum = 75) improved from 23 points pre-operaively to 52 points post latissimus dorsi transfer (p < 0.05). All patients had improvement in shoulder pain following the operation. There was a trend for younger patients to have greater improvement in functional activity and shoulder movement. From our series, latissimus dorsi transfer is effective at improving functional outcomes in patients with massive, irreparable rotator cuff tears, especially in younger age groups


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 10 - 10
1 May 2012
Chaudhury S Holland C Porter D Vollrath F Carr AJ
Full Access

Improved understanding of the biomechanics and biology of rotator cuff tendons (RCT) may help reduce high re-rupture rates following repairs, particularly amongst larger tears. This study aims to use novel methods for quantitatively determining differences in the mechanical and thermal properties of intact healthy RCTs compared to torn ‘diseased’ tendons. A common problem in the mechanical testing of small tendon samples is that stress risers at the clamp-tendon interface can obscure measurements. As the shoulder is subject to shear, tension and compression, we developed a novel solution using Dynamic Shear Analysis (DSA), a form of rheology which studies material deformation. As collagen is the main component of RCT, the structure and mechanical properties may be affected by collagen conformational changes. Both dermis and rat tail tendon with increased collagen cross-linking exhibit stronger mechanical properties. Thermal changes detected by differential scanning calorimetry (DSC) can help to quantify collagen structural differences in torn RCT, and has been previously used to study muscle, cartilage and vertebral discs. There were 79 tears (mean age 65.2 years), which were classified according to the size of the tear as small, medium, large and massive. Two separate 3mm-sized biopsy samples were taken and subjected to DSA using oscillatory deformation under compression. The storage modulus (G') was calculated and used as an indicator of mechanical integrity. 18 control tendon specimens were obtained from patients aged between 22-89 years (mean age 58.8 years) during shoulder hemiarthroplasties and stabilisations. Additionally 7 normal, 7 small and 7 massive frozen specimens were thermally characterized. 3 samples per patient were heated between 20-80oC in hermetically sealed vessels. Useful thermal parameters were measured such as the melting temperature (TM) which apparently represents breaking of the amide-amide bonds and protein chains mobility, the denaturation temperature (TD) which supposedly corresponds to proteins falling out of solution and the denaturation enthalpy (ΔH) which reflects the relative amount of triple helical structure. Healthy tendons had a significantly higher modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.032). Normal tendons had significantly higher mean shear modulus than tendons with small and massive tears (p<0.01). Overall there was a negative correlation between moduli and severity of tendon tear (r = −0.698, p=0.189). The moduli did not significantly correlate with age, sex, hand dominance, or length of preservation in formalin. Massive RCT tears had significantly higher TM and TD when compared to normal RCT (p < 0.05), unlike small RCT tears. No significant difference was detected between the denaturation enthalpy of the different RCT groups. This case control study has demonstrated that normal RCTs have a significantly higher modulus than torn tendons, indicating that torn tendons have less mechanical integrity. Our study further demonstrated a trend between increasing tear size and decreasing mechanical integrity. This study has also demonstrated differences in some of the thermal properties of normal and torn RCTs. These are likely due to collagen structural changes. A decrease in the denaturation temperature of torn tendons, suggests that the material is intrinsically less stable. Torn tendons with reduced storage modulus and collagen integrity may be less able to withstand mechanical loads following repair. This pilot study provides some preliminary insight into the mechanisms that may contribute to, or represent adaptations to high rates of failure of RCT repairs


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 448 - 453
1 Mar 2010
Benson RT McDonnell SM Knowles HJ Rees JL Carr AJ Hulley PA

The aim of this study was to investigate the occurrence of tissue hypoxia and apoptosis at different stages of tendinopathy and tears of the rotator cuff.

We studied tissue from 24 patients with eight graded stages of either impingement (mild, moderate and severe) or tears of the rotator cuff (partial, small, medium, large and massive) and three controls. Biopsies were analysed using three immunohistochemical techniques, namely antibodies against HIF-1α (a transcription factor produced in a hypoxic environment), BNip3 (a HIF-1α regulated pro-apoptotic protein) and TUNEL (detecting DNA fragmentation in apoptosis).

The HIF-1α expression was greatest in mild impingement and in partial, small, medium and large tears. BNip3 expression increased significantly in partial, small, medium and large tears but was reduced in massive tears. Apoptosis was increased in small, medium, large and massive tears but not in partial tears.

These findings reveal evidence of hypoxic damage throughout the spectrum of pathology of the rotator cuff which may contribute to loss of cells by apoptosis. This provides a novel insight into the causes of degeneration of the rotator cuff and highlights possible options for treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1386 - 1391
1 Oct 2008
Ozbaydar M Elhassan B Esenyel C Atalar A Bozdag E Sunbuloglu E Kopuz N Demirhan M

We compared time-dependent changes in the biomechanical properties of single-and double-row repair of a simulated acute tear of the rotator cuff in rabbits to determine the effect of the fixation techniques on the healing process.

A tear of the supraspinatus tendon was created in 80 rabbits which were separated into two equal groups. A single-row repair with two suture anchors was conducted in group 1 and a double-row repair with four suture anchors in group 2. A total of ten intact contralateral shoulder joints was used as a control group. Biomechanical testing was performed immediately post-operatively and at four and eight weeks, and histological analysis at four and eight weeks.

The mean load to failure in group 2 animals was greater than in group 1, but both groups remained lower than the control group at all intervals. Histological analysis showed similar healing properties at four and eight weeks in both groups, but a significantly larger number of healed tendon-bone interfaces were identified in group 2 than in group 1 at eight weeks (p < 0.012).

The ultimate load to failure increased with the number of suture anchors used immediately post-operatively, and at four and eight weeks. The increased load to failure at eight weeks seemed to be related to the increase in the surface area of healed tendon-to-bone in the double-row repair group.


Bone & Joint Research
Vol. 3, Issue 5 | Pages 155 - 160
1 May 2014
Carr AJ Rees JL Ramsay CR Fitzpatrick R Gray A Moser J Dawson J Bruhn H Cooper CD Beard DJ Campbell MK

This protocol describes a pragmatic multicentre randomised controlled trial (RCT) to assess the clinical and cost effectiveness of arthroscopic and open surgery in the management of rotator cuff tears. This trial began in 2007 and was modified in 2010, with the removal of a non-operative arm due to high rates of early crossover to surgery.

Cite this article: Bone Joint Res 2014;3:155–60.


Bone & Joint Research
Vol. 3, Issue 9 | Pages 262 - 272
1 Sep 2014
Gumucio J Flood M Harning J Phan A Roche S Lynch E Bedi A Mendias C

Objectives

Rotator cuff tears are among the most common and debilitating upper extremity injuries. Chronic cuff tears result in atrophy and an infiltration of fat into the muscle, a condition commonly referred to as ‘fatty degeneration’. While stem cell therapies hold promise for the treatment of cuff tears, a suitable immunodeficient animal model that could be used to study human or other xenograft-based therapies for the treatment of rotator cuff injuries had not previously been identified.

Methods

A full-thickness, massive supraspinatus and infraspinatus tear was induced in adult T-cell deficient rats. We hypothesised that, compared with controls, 28 days after inducing a tear we would observe a decrease in muscle force production, an accumulation of type IIB fibres, and an upregulation in the expression of genes involved with muscle atrophy, fibrosis and inflammation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 680 - 684
1 May 2008
Simon DWN Clarkin CE Das-Gupta V Rawlinson SCF Emery RJ Pitsillides AA

We examined cultured osteoblasts derived from paired samples from the greater tuberosity and acromion from eight patients with large chronic tears of the rotator cuff.

We found that osteoblasts from the tuberosity had no apparent response to mechanical stimulation, whereas those derived from the acromion showed an increase in alkaline phosphatase activity and nitric oxide release which is normally a response of bone cells to mechanical strain. By contrast, we found that cells from both regions were able to respond to dexamethasone, a well-established promoter of osteoblastic differentiation, with the expected increase in alkaline phosphatase activity.

Our findings indicate that the failure of repair of the rotator cuff may be due, at least in part, to a compromised capacity for mechanoadaptation within the greater tuberosity. It remains to be seen whether this apparent decrease in the sensitivity of bone cells to mechanical stimulation is the specific consequence of the reduced load-bearing history of the greater tuberosity in these patients.