Bone-patellar tendon-bone autografts, hamstring autografts or allografts are widely used grafts for ACL revision surgeries. Also use of quadriceps autograft for both primary and revision ACL surgeries is in an increasing popularity due to its biomechanical superior properties and less donor site morbidity. However, although several fixation techniques and devices for quadriceps tendon graft fixation on femoral side have been reported, literature lacks about biomechanical studies comparing properties of these different fixation techniques and devices. We aimed to investigate whether there is a difference between the fixation techniques of quadriceps tendon graft by using different fixation techniques and devices on the femoral side in terms of stiffness and amount of slippage in the tunnel. Full-thickness central parts of quadriceps tendons from paired knees of twenty five calf knees were fixed through a 10mm x 25mm tunnel in twenty five paired sheep femurs. Quadriceps tendon patellar side with soft tissue ending fixed with four different fixation devices (adjustable suspensory system (group 1), absorbable interference screw (group 2), titanium interference screw (group 3) and adjustable suspensory system + absorbable interference screw (group 4)) and quadriceps tendon with a patellar bone plug fixed with a titanium interference screw (group 5) were tested in a servohydraulic materials testing machine. 10 samples were included in each group. After applying a preload of 10 N, a cyclic force was applied for 20 cycles from 10N to 110N at a 1 hertz frequency. Amount of slippage in the tunnel was calculated as the difference measured in millimeters between length at 10 N after 20 cycles and starting length at 10 N (Graph 1). To determine the stiffness, a single load-to-failure cycle was performed at a strain rate of 20 mm/min as the last step (Figure 1). Rupture of the graft was not seen in any of the samples. Median values of amount of slippage in the tunnel were 6,41mm, 5,99mm, 3,01mm, 4,83mm, and 3,94mm respectively. Median values of maximum load at failure were 464N, 160N, 350N, 350N and 389N respectively. Amount of slippage in the tunnel was highest in the group 1 and was lowest in the group 3 (p<0.001). Group 1 was found to be most resistant group against load-to-failure test and group 2 was the weakest (p<0.001). However inter-group analyses between group 3 and 5 revealed that, although group 3 had the least slippage in the tunnel, group 5 was better in terms of stiffness, but there was no statistically significant difference (p=0,124 and 0,119 respectively). There was a significant difference between group 2 and 3 in both amount of slippage in the tunnel and stiffness (p=0,001 and 0.028 respectively)(Table 1). Our study revealed that, although quadriceps graft with a bone plug fixed with metal interference screws is widely presumed to be a stable fixation technique, there was no significant difference in terms of stiffness when compared with quadriceps graft with soft tissue ending fixed with a metal interference screw. Although adjustable suspensory device group was the best in the terms of resistance against load-to-failure, it was the worst in terms of amount of slippage from the tunnel. Thus, if a suspensory device is to be used, it must be kept in mind that a strong 20 cycles of intra-operative tension force must be applied to prevent further slippage of the graft in the tunnel which can result in failure of
Introduction. The recent introduction of Chatbots has provided an interactive medium to answer patient questions. The accuracy of responses with these programs in limb lengthening and
Abstract. Objectives. Three-dimensional visualisation of sonographic callus has the potential to improve the accuracy and accessibility of ultrasound evaluation of fracture healing. The aim of this study was to establish a reliable method for producing three-dimensional
Introduction and Objective. Scapholunate instability is the most common cause of carpal instability. When this instability is left untreated, the mechanical relationship between the carpal bones is permanently disrupted, resulting in progressive degenerative changes in the radiocarpal and midcarpal joints. Different tenodesis methods are used in the treatment of acute or early chronic reducible scapholunate instability, where arthritis has not developed yet and the scapholunate ligament cannot be repaired. Although it has been reported that pain is reduced in the early follow up in clinical studies with these methods, radiological results differ between studies. The deterioration of these radiological parameters is associated with wrist osteoarthritis as previously stated. Therefore, more studies are needed to determine the tenodesis method that will improve the wrist biomechanics better and will last longer. In our study, two new tenodesis methods, spiral antipronation tenodesis, and anatomic front and back
Limited information is published regarding the activity level after gracilis autograft
Introduction. Treatment strategies for irreparable Massive Rotator Cuff Tears (MRCTs) are debatable, especially for younger, active patients. Superior Capsular
The anterolateral ligament (ALL) has been recently recognized as a distinct stabilizer for internal rotation in the ACL-deficient knee and it has been hypothesized that ALL
Introduction. Supraspinatus and infraspinatus tears (Massive Rotator Cuff Tear- MRCT) cause compensatory activation of the teres minor (TM) and subscapularis (SubS) to maintain humeral head alignment. This study measures force changes in TM and SubS using a dynamic shoulder testing setup. We hypothesize that combining superior capsule
Insufficiency of the lateral collateral ligamentous complex causes posterolateral rotatory instability (PLRI). During
Background. In certain clinical situations, complex local anatomy and limitations of surgical exposure can make adequate and bone tumor ablation, resection and
Successful
Background. Return to sports after anterior cruciate ligament reconstruction (ACLR) is multifactorial and rotational stability is one of the main concerns. Anterolateral ligament
Introduction. The standard treatment of proximal humerus fractures includes pre-contoured metal plates and up to nine cortical and trabecular screws. Frequent failures are reported, especially in case of poor bone quality. The scope of this study was to assess the strength of an innovative
To design slow resorption patient-specific bone graft whose properties of bone regeneration are increased by its geometry and composition and to assess it in in-vitro and in-vivo models. A graft composed by hydroxyapatite (HA) and β-TCP was designed as a cylinder with 3D gyroid porosities and 7 mm medullary space based on swine's anatomy. It was produced using a stereolithography 3D-printing machine (V6000, Prodways). Sterile bone grafts impregnated with or without a 10µg/mL porcine BMP-2 (pBMP-2) solution were implanted into porcine femurs in a bone loss model. Bone defect was bi-weekly evaluated by X-ray during 3 months. After sacrifice, microscanner and non-decalcified histology analysis were conducted on biopsies. Finally, osteoblasts were cultured inside the bone graft or in monolayer underneath the bone graft. Cell viability, proliferation, and gene expression were assessed after 7 and 14 days of cell culture (n=3 patients). 3D scaffolds were successfully manufactured with a composition of 80% HA and 20% β-TCP ±5% with indentation compressive strength of 4.14 MPa and bending strength of 11.8MPa.
BMP2-impregnated bone graft is a promising patient-personalized 3D-printed solution for bone defect regeneration, by promoting neighboring host cells recruitment and solid new bone formation. For any figures and tables, please contact the authors directly.
Introduction. The medial patellofemoral ligament (MPFL) is the main stabilizer of the patella and therefore mostly reconstructed in the surgical correction of patellofemoral dislocation. Various biomechanical and clinical studies have been conducted on MPFL reconstruction, while the patellofemoral contact pressure (PFCP) which is indicated as one of the predictors of retropatellar osteoarthritis was neglected. Therefore, the aim of this study was to investigate how different MPFL reconstruction approaches affect PFCP. Material & Methods. After radiographic examination and preparation six human cadaveric knee joints (52.1 ± 8.4yrs) were placed in a 6-DOF knee simulator. Three flexion-extension cycles (0–90°) were applied, while the extensor muscles (175N) and an axial joint load (200N) were simulated. PFCP was measured in knee flexion of 0°, 30° and 90° using a calibrated pressure measurement system (K-Scan, Tekscan Inc., USA). The following MPFL conditions were examined: native (P. nat. ), anatomical
We evaluated two
The retear of the rotator cuff (RC) repair is a significant problem. Usually it is the effect of poor quality of the tendon. The aim was to evaluate histologically two types of RC
Summary. This work proposes a novel, automatic method to obtain an anatomical
Various arthroscopic techniques using differing graft materials have been described and present a potential alternative to arthroplasty for rotator cuff arthropathy. We describe the short-term outcomes of allograft
Injuries of the posterolateral corner (PLC) of the knee are uncommon, but can lead to chronic disability from persistent instability and resultant articular cartilage degeneration if not appropriately treated. Although numerous reconstructive techniques have been described in the literature, there is no consensus on a single surgical approach due to a lack of consistent, long-term clinical outcomes. Nonanatomic