header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Research

EFFECT OF CAPSULE REPAIR ON ROTATIONAL AND VARUS STABILITY IN PLRI RECONSTRUCTION

European Orthopaedic Research Society (EORS) 2016, 24th Annual Meeting, 14–16 September 2016. Part 1.



Abstract

Insufficiency of the lateral collateral ligamentous complex causes posterolateral rotatory instability (PLRI). During reconstruction surgery the joint capsule is repaired, but its biomechanical influence on elbow stability has not been described. We hypothesized that capsular repair reduces ROM and varus angle after reconstruction of the lateral collateral complex.

Six fresh frozen cadaveric elbow specimens were used. Varus laxity in supination, pronation and neutral forearm rotation with 1 Nm load and forearm rotaitonal range of motion (ROM) with 0.3 Nm torque were measured using a Microscribe 3DLX digitizing system (Revware Inc, Raleigh, NC). Each specimen was tested under four different conditions: Intact, Complete Tear with LUCL, RCL and capsule tear, LUCL/RCL reconstruction + capsule repair and LUCL/RCL reconstruction only. Reconstruction was performed according to the docking technique (Jones, JSES, 2013) and the capsule was repaired with mattress sutures. Each condition was tested in 30°, 60° and 90° elbow flexion. A two-way ANOVA with Tukey's post-hoc test was used to detect statistical differences between the conditions.

Total ROM of the forearm significantly increased in all flexion angles from intact to Complete tear (p<0.001). ROM was restored to normal in 30° and 60° elbow flexion in both reconstruction conditions (p>0.05). LUCL/RCL Reconstruction + capsule repair in 90° elbow flexion was associated with a significantly lower ROM compared to intact (p=0.0003) and reconstruction without capsule repair (p=0.015). Varus angle increased significantly from intact to complete tear (p<0.0001) and restored to normal in both reconstruction conditions (p>0.05) in 30° and 60° elbow flexion. In contrast varus angle was significantly lower in 90° elbow flexion in both reconstruction conditions compared to intact (both p<0.0001).

Reconstruction of the lateral collateral complex restores elbow stability, ROM and varus laxity independent of capsular repair. Over tightening of the elbow joint occurred in 90° elbow flexion, which was aggravated by capsular repair. Over all capsular repair can be performed without negatively affecting elbow joint mobility.