Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 532 - 538
1 Apr 2015
Scott CEH Davidson E MacDonald DJ White TO Keating JF

Radiological evidence of post-traumatic osteoarthritis (PTOA) after fracture of the tibial plateau is common but end-stage arthritis which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and outcomes of, total knee arthroplasty after fracture of the tibial plateau and to compare this with an age and gender-matched cohort of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight men) with a mean age of 65 years (40 to 89) underwent TKA at a mean of 24 months (2 to 124) after a fracture of the tibial plateau. Of these, 24 had undergone ORIF and seven had been treated non-operatively. Patients were assessed pre-operatively and at 6, 12 and > 60 months using the Short Form-12, Oxford Knee Score and a patient satisfaction score. Patients with instability or nonunion needed total knee arthroplasty earlier (14 and 13.3 months post-injury) than those with intra-articular malunion (50 months, p < 0.001). Primary cruciate-retaining implants were used in 27 (87%) patients. Complication rates were higher in the PTOA cohort and included wound complications (13% vs 1% p = 0.014) and persistent stiffness (10% vs 0%, p = 0.014). Two (6%) PTOA patients required revision total knee arthroplasty at 57 and 114 months. The mean Oxford knee score was worse pre-operatively in the cohort with primary osteoarthritis (18 vs 30, p < 0.001) but there were no significant differences in post-operative Oxford knee score or patient satisfaction (primary osteoarthritis 86%, PTOA 78%, p = 0.437). Total knee arthroplasty undertaken after fracture of the tibial plateau has a higher rate of complications than that undertaken for primary osteoarthritis, but patient-reported outcomes and satisfaction are comparable. Cite this article: Bone Joint J 2015;97-B:532–8


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 3 - 3
1 Feb 2020
Jenkinson M Arnall F Meek R
Full Access

National guidelines encourage the use of total hip arthroplasty (THA) to treat intracapsular neck of femur fractures. There have been no population based studies appraising the surgical outcomes for this indication across an entire population. This study aims to calculate the complication rates for THA when performed for a fractured neck of femur and compare them to THA performed for primary osteoarthritis in the same population. The Scottish Arthroplasty Project identified all THAs performed in Scotland for neck of femur fracture and osteoarthritis between 1st of January 2009 and 31st December 2014. Dislocation, periprosthetic infection and revision rates at 1 year were calculated. The rate of dislocation, periprosthetic infection and revision at 1 year were all significantly increased among the fracture neck of femur cohort. In total 44046 THAs were performed, 38316 for OA and 2715 for a neck of femur fracture. 2.1% of patients (n=57) who underwent a THA for a neck of femur fracture suffered a dislocation in the 1st year postoperatively, compared to 0.9% (n=337) when the THA was performed for osteoarthritis. Relative Risk of dislocation: 2.4 (95% C.I. 1.8077–3.1252, p value <0.0001). Relative Risk of infection: 1.5 (95% C.I. 1.0496–2.0200, p value 0.0245) Relative Risk of revision: 1.5 (95% C.I. 1.0308–2.1268, p value 0.0336). This is the first time a dislocation rate for THA performed for a neck of femur fracture has been calculated for an entire population. As the number of THAs for neck of femur fracture increases this dislocation rate will have clinical implications


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 16 - 16
1 Feb 2013
Clement N Burnett R
Full Access

There is conflicting data from small retrospective studies as to whether pre-operative mental health influences the outcome of total knee replacement (TKR). We assessed the effect of mental disability upon the outcome of TKR and whether mental health improves post-operatively. During a three year period patients undergoing TKR for primary osteoarthritis at the study centre had prospectively outcome data recorded (n=962). Pre-operative and one year short-form (SF) 12 scores and Oxford knee scores (OKS) were obtained. The mental component of the SF-12 was stratified into four groups according to level of mental disability (none ≥50, mild 40to49, moderate 30to39, severe <30). Ethical approval was obtained (11/AL/0079). Patients with any degree of mental disability had a significantly greater subjective physical disability according to the SF-12 (p=0.06) and OKS (p<0.001). Although the improvement in the disease specific score (OKS) was not affected by a patients mental health (p=0.33). In contrast the improvement of the global physical health (SF-12) for patients with a mental disability did not improve to the same magnitude (p<0.001). However, patients with mental disability, of any degree, had a significant improvement in their mental health post-operatively (p<0.0001). Despite the similar improvement in the disease specific scores and improvement in their mental health, patients with mental disability were significantly more likely to be dissatisfied with their TKR at one year (p=0.001). TKR for patients with poor mental health benefit from improvement in their mental health and in their knee function, but do have a higher rate of dissatisfaction


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 1 - 1
1 Feb 2013
Baird E Macdonald D Gilmour A Kumar C
Full Access

We reviewed the outcome of Agility total ankle replacements carried out in our institution between 2002 and 2006. Follow-up consisted of clinical and radiological review pre-operatively, at 6 weeks, 6 and 12 months, and annually until 10 years post-op. Clinical review included the American Orthopaedic Foot and Ankle Score, satisfaction and pain scores. 30 arthroplasties were performed in 30 consecutive patients. Pre-operative diagnosis was rheumatoid arthritis (16), primary osteoarthritis (12) and post-traumatic osteoarthritis (2). After a mean follow up of 6.2 years (1.4–10.1), 4 patients had died, and 20 out of the remaining 24 were available for follow-up. Complications included lateral malleoli fracture (3), superficial peroneal nerve injury (2), one early death, unrelated to the surgical procedure, delayed syndesmotic union (1), non-union (6) and deep infection (2), of which one underwent removal of the implant; the other receives long-term oral antibiotics. AOFAS scores improved from mean 40.4 pre-op to 83.5 post-op (p<0.001). Radiological assessment revealed 25 (93%) patients had lucency in at least one zone in the AP radiograph. We found a relatively high level of re-surgery and complications following Agility total ankle replacement. A 7% revision rate is much higher than would be tolerated in knee or hip arthroplasty, but compares favourably to other studies of TAR. Despite radiological loosening, and the high rate of re-surgery and complications; patients are generally satisfied with the procedure, reporting lower levels of pain and improved function. Overall, we feel that the Agility ankle is an acceptable alternative to arthrodesis, however patients should be warned of the risk of re-surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 39 - 39
1 Sep 2012
Lee MC Lee SM Seong SC Lee S Jang J Lee JK Shim SH
Full Access

Summary. UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. Introduction. Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA. Methods. Ninety patients with primary osteoarthritis of the knee were randomized to undergo computer assisted TKA with PS(n = 45) or UC(n = 45) prostheses and were followed up for a minimum 2 years. The passive kinematic evaluation was performed before and after implantation with a navigation system. Three parameters of tibiofemoral relationship (anterior/posterior translation, varus/valgus alignment and rotation) were recorded from 0° to 120° of flexion. The patients were clinically and radiographically evaluated at final follow-up. Results. Paradoxical anterior translation of the femur was observed from 0° to 70° of flexion in PS(8.7mm) and 0° to 85° in UC knees(10.4mm, p = 0.064). The distance of femoral roll-back was 6.7mm and 5.5mm, but never reached the starting point. Paradoxical internal rotation of the femur was found from 0° to 62° of flexion in PS(9.9°) and 0° to 47° in UC knees(5.6°, p = 0.002). UC knees showed more external rotation of the femur during flexion from 0° to 120°(5.7:11.0, p = 0.048). There was no significant difference in the maximal flexion(123.3°:125.5°, p = 0.366), AKS knee scores(95.9:92.0, p = 0.101), AKS function scores(86.2:82.9, p = 0.435) and WOMAC index scores(13.4:15.9, p = 0.268). There was no progressive radiolucent line or loosening in all knees. Discussion and Conclusion. UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. There was no difference in clinical outcome between two designs. UC TKA showed comparable kinematic and clinical results to PS TKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 423 - 423
1 Sep 2012
Widemschek M Pfanner G Germann R Benesch T Waibel R Strempel A Martin A
Full Access

Background. In the literature are different data about the allogenic blood transfusion rate after total knee replacement. The common intention in orthopedic surgery is to reduce the requirement for allogenic blood transfusions by optimizing the blood management. The aim of this study is to determine the efficacy of the mechanical autotransfusion system OrthoPAT® to reduce the postoperative allogenic blood transfusion (ABT) rate. Method. According to the preliminary performed power analysis we did a prospective controlled study including 151 patients which were randomized in a group A (OrthoPAT® for intra- and postoperative blood salvage and retransfusion, n=76 patients) and a control group B (no retransfusion system was used, n=75 patients). All patients had a primary osteoarthritis of the knee and were operated on without use of a tourniquet. We implanted in all patients a cemented posterior stabilized total knee prosthesis design. In group A the autotransfusion system was used for 6 hours (intra- and postoperatively) and the collected blood was retransfused. The retransfused blood was anticoagulated, filtered and centrifuged to separate waste products. Red cells were washed with saline and reconcentrated to a high hematocrit. The preoperative data for cardiopathy, angiopathy, preoperative anemia or anticoagulant treatment showed no significant differences for group A and B. Because of missing data we finally were able to use the results of 140 patients: 70 group A and 70 in group B. The indications for a blood transfusion were influenced by the clinical symptoms of anemia, the hemoglobin value (hemoglobin < 8.0 g/dl) and the anamnesis of cardiovascular diseases. Evaluation was done with the medical history and the pre-/postoperative hemoglobin values and postoperative need of allogenic blood transfusion. Results. The two groups showed no significant differences relating to the demographic data or the medical history. 23 patients (33 %) of the retransfusion group who in mean received 281 ml of salvaged blood needed allogenic blood transfusion compared with 23 patients (33 %) of the control group B (p=0,999). The hemoglobin values of group A versus the control group showed after the donation of the salvaged blood a tendency to a higher hemoglobin value (p=0,062) but no longer at the third and fifth day postoperative. Conclusions. In this clinical observation the use of the autotransfusion system does not reduce the postoperative allogenic blood transfusion rate. At the third and fifth day postoperatively no significant differences of the hemoglobin values could be stated comparing group A with group B


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 421 - 421
1 Sep 2012
Young L Kent M Rehmatullah N Chojnowski A
Full Access

Purpose. To analyse the early results of unconstrained pyrocarbon joint replacements in patients with osteo-arthritis of the metacarpo-phalangeal joints. Background. Silicone arthroplasty, as introduced by Swanson in 1962 has remained the most popular procedure to treat arthritis of the metacarpo-phalangeal (MCP) joints. However, despite providing good pain relief, they have shown to demonstrate breakage rates up to 82% at 5 years. This is of great concern in the osteoarthritis (OA) patient group, who tend to be younger and have higher functional demands compared to their rheumatoid counterparts. The newer unconstrained pyrolytic carbon MCP joint prostheses may therefore be more suitable in OA patients whose soft tissue constraints are intact and whose hand function is strong. This study is the first to analyse the results of this implant in a cohort of OA patients only, with prospective data. Methods. 19 primary pyrocarbon metacarpo-phalangeal joint replacements, in 11 patients (5 men and 6 women) were reviewed, with prospective data collection. The diagnosis was primary osteoarthritis in all patients. The mean age at operation was 66.4 years (range 55–82 years). 2 patients underwent concomitant trapiezectomy and one underwent DIPJ fusion. All patients were right hand dominant −75% underwent surgery in their dominant hand. Eleven of the nineteen joints were performed in the index finger, with the remainder in the middle finger. Mean follow up is 22.1 months (range 11–37). Results. At the 3 month post-operative hand therapy assessment, the arc of motion had improved from a mean of 32 degrees to 45 degrees and flexion had improved from a mean of 51 degrees to 66 degrees. Grip strength improved from a mean 20 to 27Kg. DASH scores significantly improved from a mean of 40 to 10 (p=0.01). All patients were satisfied with their outcomes and would have the surgery again. Pre-operative radiographs demonstrated joint narrowing in all patients but no evidence of heterotopic ossification, cystic change or erosions. Post-operatively, there has been no radiographic evidence of joint dislocation, resorption stress-shielding, loosening, migration or heterotopic ossification. There were three intra-operative complications of phalangeal fractures that were immediately treated with a cerclage wire. In one patient there has been a fracture of the proximal phalangeal implant at 14 months which was asymptomatic. One patient has required revision for mal-rotation of the implant leading to loss of index finger supination. Conclusion. Our results demonstrate excellent early results of pyrocarbon MCP joint arthroplasty in OA patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 363 - 363
1 Sep 2012
Lübbeke A Garavaglia G Roussos C Barea C Peter R Hoffmeyer P
Full Access

Introduction. A recent review of the literature on metal-on-metal total hip arthroplasties (THA) revealed the lack of comparative clinical studies with a sufficient sample size and the inclusion of patient-reported outcomes as well as patient activity levels. Methods. We conducted a prospective cohort study including all metal-on-metal and conventional polyethylene (PE)-ceramic THAs with an uncemented cup (Morscher press-fit cup), a 28mm head and operated upon via a lateral approach at our University hospital between 1/1999 and 12/2008. Only THAs for primary osteoarthritis were included. The study population is part of the Geneva Hip Arthroplasty Registry, a prospective cohort followed since 1996. The following outcomes were compared between the two groups (metal-on-metal=group 1 vs. PE-ceramic bearing=group 2): (1) Complication rates with respect to infection, dislocation and revision, (2) Radiographic outcomes (presence of linear or focal femoral osteolysis, loosening), and (3) Clinical outcomes (Harris Hip score increase, SF-12, activity and patient satisfaction evaluation, presence of groin pain). Patients operated between 1/1999 and 12/2004 were evaluated five years postoperatively by an independent assessor. Cox regression analysis was used to compare incidence rates while adjusting for differences in baseline characteristics. Results. 1988 THAs were included, 544 with a metal-on-metal and 1444 with a PE-ceramic bearing. The two groups differed significantly with respect to gender distribution (men 56% vs. 41%), mean age (66 vs. 73 years), co-morbidities and type of stem (uncemented 16% vs. 2%). Crude incidence rates for complications were: 0.16 vs. 0.11 cases/100 person-years for infection; 0.37 vs. 0.35 cases/100 person-years for dislocation; and 0.29 vs. 0.16 cases/100 person-years for all-cause revision (incidence rate ratio 1.8, 95% CI 0.7; 4.6). After adjusting for baseline differences the slightly higher risks for infection and revision in group 1 were attenuated. Osteolytic lesions were found in 3.7% of metal-on-metal vs. 4.7% of PE-ceramic THAs. After adjustment for age, gender and activity the OR was 0.6 (95% CI 0.2;2.1). Five years postoperative, 176 THAs of group 1 and 695 THAs of group 2 were seen at follow-up. Clinical outcomes were similar among the two groups with a mean Harris Hip score increase of 39.2 vs. 40.9 points. SF-12 mental and physical health, patient satisfaction (9.3 vs. 8.9 on visual analogue scale) as well as the incidence of groin pain (1.7% vs. 1.2%) was also similar among the two groups. The activity level was significantly higher in group 1 (6.4 vs. 5.4, p<0.001). Conclusion. Mid-term results with respect to complications, revision rates, presence of osteolysis and clinical outcomes were similar among patients with metal-on-metal and PE-ceramic total hip arthroplasties


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 529 - 529
1 Sep 2012
Schoenahl J Gaskill T Millett P
Full Access

Introduction. Osteoarthritis of the glenohumeral joint leads to global degeneration of the shoulder and often results in humeral or glenoid osteophytes. It is established that the axillary neurovascular bundle is in close proximity to the glenohumeral capsule. Similar to other compressive neuropathies, osteophytic impingement of the axillary nerve could result in axillary nerve symptoms. The purpose of this study was to compare the proximity of the axillary neurovascular bundle to the inferior humerus in shoulders to determine distance of the neurovascular bundle as the osteophyte (goat's beard) of glenohumeral osteoarthritis develops. Methods. In this IRB approved study, preoperative MRI's of 98 shoulders (89 patients) with primary osteoarthritis (OA group) were compared to 91 shoulders (86 patients) with anterior instability (Control group). For MRI measurements (mm) two coronal-oblique T1 or proton density weighted images were selected for each patient located at 5 and 6 o'clock position of the glenoid in the parasagittal plane. Humeral head diameter to standardize the glenohumeral measurements, size of the spurs, and 6 measurements between osseus structures and axillary neurovascular bundle were obtained on each image using a calibrated measurement system (Stryker Office PACS Power Viewer). Level of significance was set at p>.05. Results. Since results were both significant at 5 and 6 o'clock, for clarity we will only give the results at 6 o'clock. Humeral head osteophytes were present in 52% (51/86) of arthritic patients with an average size of 9.90 mm (range 0–24.31). Distance between humeral head or inferior osteophyte and neurovascular bundle was significantly decreased (p<0.05) in the OA group, 19.74 mm (range 2.80–35.12) compared to the control group 23.8 mm (14.25–31.89). If we compare the same distance between the Control group, OA group with a spur and OA group without a spur, the difference is only significant between the Control group and OA with spur. (p<0.05) In non-arthritic patients, the neurovascular bundle was closest to the inferior glenoid rim in all patients (91/91). By contrast, the neurovascular bundle was closest to the humeral head in 26.5% (26/98) of arthritic patients. Among these 26 patients, a large humeral head osteophyte was present in 96% (25/26). The neurovascular bundle distance and humeral head osteophyte size were inversely correlated (r=−0.45 at 5 o'clock, r=−0.546 at 6 o'clock) in the arthritic group (p<0.05). Discussion. The axillary neurovascular bundle was significantly closer to the osseous structures (humerus) in arthritic patients compared to non-arthritic patients (p<0.05). The neurovascular bundle was significantly closer to the bone when there was a humeral osteophyte, and the distance was inversely proportional to humeral osteophyte size (p<0.05). This study indicates humeral osteophytes are capable of encroaching on the axillary nerve. Axillary nerve entrapment may be a contributing and treatable factor of pain in patients with glenohumeral osteoarthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 579 - 579
1 Sep 2012
Grammatopoulos G Pandit H Backer K Gundle R Mclardy-Smith P Desmet K Murray D Gill H
Full Access

INTRODUCTION. Femoral neck narrowing (NN) following Metal-on-Metal Hip Resurfacing Arthroplasty (MoMHRA) is a well-recognised clinical phenomenon. The incidence of resurfaced hips with NN > 10% is reported to be up to 27%. Its pathogenesis is thought to be multi-factorial secondary to stress shielding, impingement, osteolysis secondary to wear/ion particles and as a result of reduced vascularity and pressure effect on cancellous bone secondary to the presence of a soft-tissue mass around the resurfaced hip. Recognised risk factors for its development include: female gender and the presence of a pseudotumour. Serum Chromium (Cr) and Cobalt (Co) are recognised surrogate markers of in-vivo wear of MoMHRA. The aims of this study were to establish whether NN is associated with increased wear. METHODS. A cohort of 214 patients with unilateral MoMHRA (139M: 75F) was included in this study. Primary osteoarthritis was the diagnosis leading to surgery for the majority of patients (208). The average age at surgery was 54.1 years old (13–73). Six different implants were used; BHR (116), Conserve plus (92), Recap (2), ASR (2), Adept (1) and Cormet (1). The average femoral component size was 49.2mm (range: 38–59). The average follow up was 4.3 years (range: 2–10). Patients were subdivided into 3 groups as per implant size. Small size component group had implants <45mm, average size group had components 45–51mm and large component size group had components >51mm. All patients had Prosthesis-Junction-Ratio (PJR) measured from postoperative (PJRpost) and at latest follow up (PJRfollow) radiographs. Measurements were made using the method described by Lilikakis1. Metal ion levels (Cr/Co) were measured at last follow-up for all patients. Cr level >5.1g/ml and Co levels >4.4 g/ml were considered high2 and patients with such levels formed the high ion group. RESULTS. For the whole cohort, mean NN was 3.2% (range: 0–32%, SD:4.3). Females (4.7%, range: 0–32%, SD: 5.8) had significantly greater NN than males (2.4%, range: 0–23%, SD: 2.9) (p=0.001). Patients in the large component group had less NN (2.1%, SD: 2.3) in comparison to the average (3.2%, SD: 3.7%) (p=0.046) and the small (5.9%, SD: 7.9) (p=0.007) component size groups. There was no difference in NN between small and average sized components (p=0.1). Patients in the high ion group (25 patients) had significantly greater NN than patients with low ions (10.1%, range: 1%–32%, SD: 8.3 Vs 2.3%, range: 0–11, SD 2.3) (p<0.0001). NN >10% was seen in 16 hips (7.5%). The odds ratio of having high ions if NN >10% was 125 (p<0.001). DISCUSSION. The findings of this study showed that greater NN occurs in females and patients with small components and in patients with high ions. Furthermore, hips with NN >10% should be investigated further as they are more likely to have increased wear


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 177 - 177
1 Sep 2012
Christofilopoulos P Lübbeke A Berton C Lädermann A Berli M Roussos C Peter R Hoffmeyer P
Full Access

Introduction. Large diameter metal on metal cups have been used in total hip arthroplasty advocating superior results with respect to dislocation rates, range of motion and long term survival. The Durom cup used as part of the Durom hip resurfacing system has been incriminated with poor short term results sometimes correlated to incorrect positioning of either the femoral or acetabular component. Our objective was to evaluate short term results of the Durom cup used in conjunction with standard stems. Methods. We prospectively followed all patients with a large diameter metal-on-metal articulation (Durom) and a standard stem operated upon between 9/2004 and 9/2008. Patients were seen at follow-up for a clinical (Harris hip score=HHS, UCLA scale and patient satisfaction), radiographic and questionnaire assessment. Results. 89 primary THAs in 80 patients (74% men) with a mean age of 52 (±12) years were included. Main diagnoses were primary osteoarthritis in 47% and aseptic necrosis in 35%. An uncemented stem was used in 79%. Overall, 80 THAs were controlled at a mean follow-up of 39 months (range 16–67 months), 4 patients were lost to follow-up and 5 patients refused or were unable to attend the visit. However, none of the 5 underwent revision. Overall, 8 THAs (8/85, 9.4%) were revised in mean 28 months (range 8–60) after the operation. One additional patient was awaiting revision for aseptic loosening of both cup and stem. The reasons for revision were aseptic loosening in three cases, presence of a granuloma (histological diagnosis of ALVAL) in three, deep infection in one and impingement in one case. Radiographic analysis revealed linear (n=2) and focal (n=3) osteolysis as well as early cup migration (n=2). In 5 revised patients no radiographic changes were found. 56 (70%) of the 80 patients with follow-up had a HHS between 80 and 100. Among those who were not revised, the mean HHS improved from 55.2 to 88.4 (mean increase 33.2, 95% CI 27.7; 38.7). The mean activity level (UCLA scale) at follow-up was 6.4 (±1.8). Overall, mild to severe pain was reported in 14 cases and occasional pain in 22. Groin pain was present in 18 patients (22.5%), 7 of them belonged to the revised group. 61 (76.3%) of the 80 patients with follow-up were satisfied. Mean patient satisfaction on the VAS scale among those who were not revised was 9.0 (±1.3). Conclusion. This study confirms the increased short-term revision rate of the large diameter metal-on-metal couple (Durom) reported by others. In all revision cases the retrieved cups showed no osteo-integration and were removed easily. The operative indication for revision was based upon groin pain and patient dissatisfaction. Radiographic signs of implant loosening were not always present even though in all revised cases except for one the cup was found loose