Advertisement for orthosearch.org.uk
Results 1 - 20 of 1923
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 483 - 489
1 Apr 2016
Tigchelaar S Rooy JD Hannink G Koëter S van Kampen A Bongers E

Aim. Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral dysfunction as a key symptom. We present the first in-depth radiological evaluation of the knee in a large series of NPS patients and describe the typical malformations. Patients and Methods. Conventional radiological examination of 95 skeletally mature patients with NPS was performed. Patellar morphology was classified according to the Wiberg classification as modified by Baumgartl and Ficat criteria, and trochlear shape was classified according to the Dejour classification. Results. Patellar aplasia was present in 4/90 (4%), and patellar hypoplasia in 77/90 (86%) of patients. The prevailing patellar shapes were type III, type IV and Hunter’s cap. No patellar shape genotype-phenotype association could be found. The malformations of the distal femur comprised shortening of the lateral femoral condyle in 46 out of 84 patients (55%), with a prominent anterior surface of the lateral femoral condyle in 47 out of 84 patients (56%) and a flat anterior surface of the medial femoral condyle in 78 out of 85 patients (92%). The trochlea was type A1 according to the Dejour classification in 79 out of 85 patients (93%). . Conclusion. An easily recognisable characteristic quartet of malformations consisting of patellar aplasiaor hypoplasia and the malformations of the distal femur was found in 22 out of 81 patients (27%), with the majority displaying at least three malformations. Take home message: The distinct malformations of the knee in nail patella syndrome are easily recognisable on conventional radiographs and lead to the correct interpretation of the aberrant morphology which is essential in the treatment of these patellofemoral disorders. Cite this article: Bone Joint J 2016;98-B:483–9


Introduction. The degree of cartilage degeneration assessed intraoperatively may not be sufficient as a criterion for patellar resurfacing in total knee arthroplasty (TKA). However, single-photon emission tomography/computed tomography (SPECT/CT) is useful for detecting osteoarthritic involvement deeper in the subchondral bone. The purpose of the study was to determine whether SPECT/CT reflected the cartilage lesion underneath the patella in patients with end-stage osteoarthritis (OA) and whether clinical outcomes after TKA without patellar resurfacing differed according to the severity of patellofemoral (PF) OA determined by visual assessment and SPECT/CT findings. Methods. This study included 206 knees which underwent TKA. The degree of cartilage degeneration was graded intraoperatively according to the International Cartilage Repair Society grading system. Subjects were classified into four groups according to the degree of bone tracer uptake (BTU) on SPECT/CT in the PF joint. The Feller's patella score and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed preoperatively and postoperative 1 and 2 years. Results. The increased BTU in the PF joint was associated with more severe degenerative cartilage changes underneath the patella (P < 0.001). The risk for the presence of denudated cartilage was greater in the high uptake group (odds ratio = 5.89). There was no association between clinical outcomes and visual grading of patellar cartilage degeneration or the degree of BTU on SPECT/CT. Discussion and Conclusions. The visual assessment of the degree of cartilage degeneration underneath the patella and preoperative SPECT/CT evaluation of the PF joint were not predictive of clinical outcome after TKA with unresurfaced patella


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 118 - 118
1 Apr 2019
Wakelin E Twiggs J Roe J Bare J Shimmin A Suzuki L Miles B
Full Access

Introduction & aims. Resurfacing of the patella is an important part of most TKA operations, usually using an onlay technique. One common practice is to medialise the patellar button and aim to recreate the patellar offset, but most systems do not well control alignment of the patella button. This study aimed to investigate for relationships between placement and outcomes and report on the accuracy of patella placement achieved with the aid of a patella Patient Specific Guide (PSG). Method. A databse of TKR patients operated on by five surgeons from 1-Jan-2014 who had a pre-operative and post-operative CT scan and 6-month postoperative Knee Osteoarthritis and Outcome (KOOS) scores were assessed. Knees were excluded if the patella was unresurfaced or an inlay technique was used. All knee operations were performed with the Omni Apex implant range and used dome patella buttons. A sample of 40 TKRs had a patella PSG produced consisting of a replication of an inlay barrel shaped to fit flush to the patient's patella bone. The centre of the quadriceps tendon on the superior pole of the patella bone and the patella tendon on the inferior were landmarked. 3D implant and bone models from the preoperative CT scans were registered to the post-operative CT scan. The flat plane of the implanted patella button was determined and the position of the button relative to the tendon attachments calculated. Coverage of the bone by the button and patellar offset reconstruction were also calculated. The sample of 40 TKRs for whom a patella PSG was produced had their variation in placement assessed relative to the wider population sample. All surgeries were conducted with Omni Apex implants using a domed patella. Results. A total of 322 patients were identified in the database, and 82 were subsequently excluded as inlay rather than onlay patella. 59% (142) were female and the average age was 68.9 years (+/− 7.2). Coverage percentage of the cut patella surface by the button was 67% (± 7%), with 83% (200) knees having greater than 60%, and 40% (96) greater than 70%. Component position was on average centralised in terms of mediolateral position (0.09mm ± 1.93 lateral). When comparing the alignment of the patients whose knees used PSG guides with those who did not, it was found there was a statistically significant reduction in the variation that both external rotation error and flexional error had (p-values 0.048 and 0.022 respectively.). Excess medialisation of the patella button was found to weakly correlate with reduced postoperative KOOS symptoms scores (coefficient=0.14, p-value = 0.035). When subdivided into patients who reported knee clicking sometimes or more often and those who did not, patients with highly medialised buttons had a 1.5× likelihood of reporting clicking of their knee joint (p-value = 0.036). Conclusions. The patella-femoral joint remains a crucial component in the TKA knee, but the process of resurfacing the bone is not well controlled and can negatively influence patient outcomes. PSG's are one potential mechanism of controlling patella component alignment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 4 - 4
1 Feb 2013
Sullivan N Robinson P Ansari A Hassaballa M Porteous A Robinson J Eldridge J Murray J
Full Access

Patello-femoral arthritis can result in a considerable thinning of the patella. The restoration of an adequate patella thickness is key to the successful outcome of knee arthroplasty. The objectives were (1) to establish a reproducible patella width:thickness index including chondral surface and (2) to investigate whether there is a difference between bone alone and bone/chondral construct thickness as shown by MRI. Forty three MRI scans of young adults, mean age 27 (range 17–38), 34 male and 9 female, were studied. Exclusion criteria included degenerative joint disease, patello-femoral pathology or age under 16/over 40 (102 patients). The bony and chondral thickness of the patella and its width were measured. Inter/intra observer variability was calculated and correlation analysis performed. We found a strong correlation between patella plus cartilage thickness and width (Pearson 0.75, P < 0.001). The mean width:thickness ratio was 1.8 (SD 0.10, 95% CI 1.77–1.83). Without cartilage the ratio was 2.16 (SD 0.15, 95% CI 2.11–2.21), correlation was moderate (Pearson 0.68, P < 0.001). The average patella cartilage thickness was 4.1mm (SD 1.1, 95% CI 3.8–4.5). The narrow confidence intervals for the ratio of patella width:thickness suggest that patella width can be used as a guide to accurate restoration of patella thickness during total knee or patella-femoral replacement. We would recommend a ratio of 1.8:1


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 29 - 29
1 May 2016
Harris S Iranpour F Riyat H Cobb J
Full Access

Introduction. The trochlea of a typical patellofemoral replacement or anterior flange of a total knee replacement usually extends past the natural trochlea and continues onto the femoral anterior cortex. One reason for this is that it allows a simple patella button to be permanently engaged in the trochlea groove in an attempt to ensure stability. On the natural patella, the apex helps to guide it into the trochlea groove as the knee moves from full extension into flexion. The aim is to study whether a generalised patella can be created that is close in form to a healthy patella. Method. MRI scans were taken of 30 patellae. Characteristics of these patellae (height, width, thickness, apex angle) were measured. The apex angle was found to be similar between patellae (mean=126 degrees, sd = 8.8), as were the ratios between height and width (mean width/height = 1.05, sd = 0.07) and between thickness and width (mean width/thickness = 1.8, sd = 0.19). These patellae were then segmented to create a surface including cartilage, resulting in 30 STL (stereolithography) files in which the surfaces are represented by triangle meshes. To design the average patella the individual patellae were aligned to a standard frame of reference by placing a set of landmarks on the proximal/distal, medial/lateral and anterior/posterior extents of each (fig.1). The vertical axis was defined as passing parallel to the proximal/distal points and the horizontal as passing parallel to the medial/lateral points when looking along the computed vertical axis. The origin centre of the frame of reference was chosen to be mid-way between these points. The mean width was then computed and each patella scaled linearly around the origin to give them all equal width. All the aligned patellae were then averaged together to provide a composite cartilaginous patella. The averaging process was achieved by taking one patella as a seed. The patella chosen for seed was that whose parameters were closest to the average width, height and thickness. An approximately normal vector was passed a point ‘P’ on the seeds, and the points at which these intersected the other models were then determined. The closest intersection point to ‘P’ on each model was chosen and these averaged together. ‘P’ is then replaced in the model with this average point. The averaging process then continues with all the remaining points on the seed model in the same manner to build the average models. Results and Discussion. The mean patella was compared with individual patellae. This comparison was performed by taking each point on the mean patella and finding the closest point on individual patellae - a colour coded map of differences was obtained (fig.2) along with a mean of the absolute difference for each patella. The absolute mean difference ranged from 0.56mm to 1.33mm, averaging at 0.85mm. This shows a reasonable fit between the average patella and each individual example, raising the possibility of using the average shape in future research to develop anatomical patellofemoral replacements and for planning patella resurfacing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 249 - 249
1 Mar 2013
Maiti R Fisher J Jin Z Rowley L Jennings L
Full Access

Introduction. Patella femoral joint bearings in total knee replacements have shown low wear (3.1 mm. 3. /MC) under standard gait simulator conditions. 1. However, the wear in retrieval studies have shown large variations between 1.3 to 45.2 mm. 3. /year. 2. Previous in vitro studies on the tibial femoral joint have shown wear is dependent on design, materials and kinematics. 3. . The aim of this study was to investigate the influence of the design (geometry) and shape on the wear rate of patella femoral joints in total knee replacements. Materials and Methods. The Leeds/Prosim knee simulator was used to investigate the wear of two types of commercially available patellae. The PFC Sigma cobalt chrome femoral component was coupled with 2 types of patellae buttons: round and oval dome. The UHMWPE was the same for the both types – GUR1020 GVF (gamma irradiated in vacuum and foiled packed). 25% bovine serum was used as the lubricant. The test were carried out at three conditions – high medial lateral (ML) rotations (<4°) and uncontrolled ML displacement (<4 mm), low ML rotation (<1°) and uncontrolled ML displacement (<4 mm); the physiological gait cycle; and low ML rotation and controlled ML displacement (<1.5 mm). In this abstract the two designs were tested in physiological gait condition (Figure 1). Patella ML displacement and tilt were passively controlled and measured after every 300,000 cycles. A ligament resisting force equivalent to 10 N4 was applied on the lateral side of the patella to avoid patella slip. Five samples of each design were tested for 3 million cycles at a cycle rate of 1 Hz. The wear volume was obtained gravimetrically every million cycles and presented with 95% confidence limits. Statistical significance was taken at p<0.05. Results and Discussions. The wear rate of PFC sigma round dome patella was higher (8.63 ± 3.44 mm. 3. /million cycles) compared to the PFC sigma oval dome patella (6.28 ± 3.89 mm. 3. /million cycles) (Figure 2). However, no significant difference in the wear rates was found between the two shapes (P=0.2). The low area of contact of oval dome patella (31.2% of total surface area) as compared to round dome patella (39.9%) led to low wear. 5. . The wear volume and the patellar tilt were positively correlated for oval dome and round dome patella, R. 2. > 0.9 (Figure 3). Increase in the patellar tilt resulted increase in sliding distance in perpendicular direction of polymer orientation. This led to higher wear volume. Conclusions. Wear rate decreased with change of patella shape from round dome to oval dome although not significantly. Increase in the patellar tilt resulted in increase in the wear volume. Acknowledgement. This research was supported in part by the DePuy and EPSRC. In addition, it was partially funded through WELMEC, a Centre of Excellence in Medical Engineering funded by the Wellcome Trust, under grant number WT 088908/Z/09/Z and additionally supported by the NIHR (National Institute for Health Research) as part of collaboration with the LMBRU (Leeds Musculoskeletal Biomedical Research Unit)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 128 - 128
1 Mar 2012
Loveday D Donell S
Full Access

Patella instability is a common problem with many surgical options. We prospectively evaluated the results of medial patella femoral ligament (MPFL) reconstruction with an autogenous gracilis or semitendinous graft. With a minimum follow up of one year patients were reviewed using the Kujala scoring system. Twenty MPFL reconstructions were performed on seventeen patients over a two year period, from January 2004 to December 2005. There were 13 females and 4 males. Three patients had bilateral involvement. Thirteen patients had a lateral release with their MPFL reconstruction and three had a distal realignment procedure as well to correct their patella instability. The mean follow up was 17 months (range 12 to 26 months). The average age was 25 years old at operation (range 13 to 47) and the average age of their first dislocation was 16 (range 0-35). Nine patients had previous surgical treatment for patella instability. The average hypermobility score in the patients was 5/9 and six patients scored 9/9. At follow up 18 out of 20 patients (90%) had stable tracking with no further subluxations/dislocations. Of the two with unstable tracking, one had a stable patella before falling several times onto her knee. An MRI confirmed the ligament was intact but a type 2 trochlear dysplasia was present and a Bereiter trochleoplasty was subsequently performed. The other patient described no frank dislocation but instead subluxations. Eighteen of the twenty reconstructions (90%) achieved a stable patella. Overall Kujala scores increased by a third


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 46 - 46
1 Mar 2013
Porteous A Sullivan N Murray J Eldridge J
Full Access

Aim. To assess if there is a reproducible relationship between the width and thickness of the normal patella. Method. 43 MRI scans of young adults, average age 27 (range 17–38) were studied. Exclusion criteria included a diagnosis of degenerative joint disease, patella-femoral pathology or age under 16/over 40 (102 patients). The bony thickness of the patella, the chondral thickness and patella width were measured, as was the location of maximal patella thickness. Inter/intra observer variability was calculated and correlation analysis performed. Results. There was a strong correlation between overall patella thickness (bone plus cartilage) and width (Pearson 0.75, P < 0.001). The width: thickness ratio is 1.8:1 (standard deviation 0.102, 95% confidence interval 1.6–2.0). The average patella cartilage thickness is 4.1mm (SD 1.3). The thickest region of the patella lies 54% (SD 2.32) from the lateral border and 54% (SD 7.9) from the superior pole. Conclusion. We propose that the normal “Index of Patella Width: Thickness” = 1.8:1. It can be used as a guide for restoring patella thickness during TKR or patella-femoral replacement to that of a knee free from age related wear and osteoarthritis. This maximal thickness should be slightly medial and distal in the patella. MULTIPLE DISCLOSURES


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 302 - 302
1 Mar 2004
Schmidt K Willburger R Wiese M Awakowicz A Heukamp M Weskamp S
Full Access

Aims: The purpose of this study was to determine whether patella replacement or RAP of the patella is advantageous in TKA. Methods: 100 patients were recruited to enter a randomised, prospective, double blind clinical trial to determine the efþcacy of patellar resurfacing during total knee arthroplasty. All patients receive the same posterior cruciatesparing prosthesis, and all operations were performed by, or under the direct supervision of the þrst author. Evaluation consisted of the determination of the HSS-Score, the knee society scores, speciþc questions relating to patellafemoral symptoms, radiographs, measurement of torques and stability of one leg standing. All knees were followed at 3 month and 18 month postoperatively. Results: There was no signiþcant difference between the two groups with regard to the HSS-Score, and the KS-scores. Excentric and concentric torques were higher in the group with RAP of the patella. One leg standing was more stable in the group with RAP of the patella. In both groups one patient complained of severe anterior knee pain. The patient with RAP of the patellar was treated successfully with secondary patella resurfacing. Conclusions: The clinical outcome and the prevalence of anterior knee pain after TKA with the PFC-∑ knee was not inßuenced by whether or not the patella had been resurfaced. Force and balance are slightly better after TKA with RAP of the patella


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 29 - 29
17 Nov 2023
Morris T Dixon J Baldock T Eardley W
Full Access

Abstract. Objectives. The outcomes from patella fracture have remained dissatisfactory despite advances in treatment, especially from operative fixation1. Frequently, reoperation is required following open reduction and internal fixation (ORIF) of the patella due to prominent hardware since the standard technique for patella ORIF is tension band wiring (TBW) which inevitably leaves a bulky knot and irritates soft tissue given the patella's superficial position2. We performed a systematic review to determine the optimal treatment of patella fractures in the poor host. Methods. Three databases (EMBASE/Medline, ProQuest and PubMed) and one register (Cochrane CENTRAL) were searched. 476 records were identified and duplicates removed. 88 records progressed to abstract screening and 73 were excluded. Following review of complete references, 8 studies were deemed eligible. Results. Complication rates were shown to be high in our systematic review. Over one-fifth of patients require re-operation, predominantly for removal of symptomatic for failed hardware. Average infection rate was 11.95% which is higher than rates reported in the literature for better hosts. Nevertheless, reported mortality was low at 0.8% and thromboembolic events only occurred in 2% of patients. Average range of movement achieved following operative fixation was approximately 124 degrees. Upon further literature review, novel non-operative treatment options have shown acceptable results in low-demand patients, including abandoning weight-bearing restrictions altogether and non-operatively treating patients with fracture gaps greater than 1cm. Regarding operative management, suture/cable TBW has been investigated as a viable option with good results in recent years since the materials used show comparable biomechanics to stainless steel. Additionally, ORIF with locking plates have shown favourable results and have enabled aggressive post-operative rehabilitation protocols. TBW with metallic implants has shown higher complication rates, especially for anterior knee pain, reoperation and poor functional outcomes. Conclusion. There is sparse literature regarding patella fracture in the poor host. Nevertheless, it is clear that ORIF produces better outcomes than conservative treatment but the optimal technique for patella ORIF remains unclear. TBW with metallic implants should not remain the standard technique for ORIF; low-profile plates of suture TBW are more attractive solutions. Non-operative treatment may be considered for low-demand individuals however any form of patellectomy should be avoided if possible. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 31 - 31
17 Nov 2023
Warren J Cowie R Jennings L Wilcox R Fermor H
Full Access

Abstract. Objectives. The aim of this study was to develop an in vitro GAG-depleted patella model and assess the biomechanical effects following treatment with a SAP:CS self-assembling hydrogel. Methods. Porcine patellae (4–6 month old) were harvested and subject to 0.1% (w/v) sodium dodecyl sulfate (SDS) washes to remove GAGs from the cartilage. Patellae were GAG depleted and then treated by injection with SAP (∼ 6 mM) and CS (10 mg) in Ringer's solution through a 30G needle. Native, GAG depleted and SAP:CS treated patellae were tested through static indentation testing, using 15g load, 5mm indenter over 1hr period. The degree of deformation of each group was assessed and compared (Mann-Whitney, p<0.05). Native, GAG depleted, sham (saline only) and SAP:CS treated paired patellae and femurs were additionally characterized tribologically through sequential wear testing when undergoing a walking gait profile (n=6 per group). The cartilage surfaces were assessed and compared (Mann-Whitney, p<0.05) using the ICRS scoring system, surface damage was illustrated through the application of Indian ink. Results. Static indentation tests indicated significant increase in indentation deformation of GAG depleted group compared to native group (n=6, p<0.01) and significant reduction in deformation of SAP:CS treated group compared to GAG depleted group (n=6, p<0.05). Sequential wear tests indicated a significant increase in the cartilage damage on the both surfaces of the patellofemoral joint in the GAG depleted group, compared to the native group (n=6, p<0.001), Following SAP:CS treatment, significant protection from damage was observed on femoral surface (n=6, p<0.005), with some non-significant reduction in damage on the patella surface. Sham injections showed no significant increase in damage compared to the native and treated samples. Conclusions. The ∼50% reduction of GAGs represented a moderate osteoarthritic patella cartilage model. This same loss transferred to the dynamic wear tests with significant changes in the damage on the femoral counter face associated with the GAG loss. SAP:CS treatment showed promise in restoring cartilage stiffness to treat Chondromalacia patella in static indentation tests. Sequential wear tests showed that the SAP:CS treatment protects the cartilage layer of both surfaces in the patellofemoral joint from damage in an extreme degeneration model. The sham injections showed that injecting cartilage with a 30G and saline does not cause any significant damage to the cartilage layer. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes. Cite this article: Bone Jt Open 2021;2(12):1075–1081


Bone & Joint Open
Vol. 3, Issue 3 | Pages 268 - 274
21 Mar 2022
Krishnan H Eldridge JD Clark D Metcalfe AJ Stevens JM Mandalia V

Recognized anatomic variations that lead to patella instability include patella alta and trochlea dysplasia. Lateralization of the extensor mechanism relative to the trochlea is often considered to be a contributing factor; however, controversy remains as to the degree this contributes to instability and how this should be measured. As the tibial tuberosity-trochlear groove (TT-TG) is one of most common imaging measurements to assess lateralization of the extensor mechanism, it is important to understand its strengths and weaknesses. Care needs to be taken while interpreting the TT-TG value as it is affected by many factors. Medializing tibial tubercle osteotomy is sometimes used to correct the TT-TG, but may not truly address the underlying anatomical problem. This review set out to determine whether the TT-TG distance sufficiently summarizes the pathoanatomy, and if this assists with planning of surgery in patellar instability. Cite this article: Bone Jt Open 2022;3(3):268–274


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 323 - 323
1 Jul 2008
Khan W Jones R Nokes L Johnson D
Full Access

Introduction: In this study the optimal angle of fixation or splintage for partially weight bearing fractures of the patella was determined by a gait analysis measurement system. Subjects and Methods: A knee brace was applied to eight subjects and locked at 0, 10, 20 and 30 degrees. Measurements were also taken for an unlocked brace and in the absence of a brace. The subjects were instructed on partial weight bearing mobilisation. Three dimensional motion analyses were performed using an infrared 8-camera system. The ground reaction force was recorded by two 3-dimensional force plates embedded in the walkway. Kinematic and kinetic data was collected and the data was transferred to a computer programme for further analysis and the forces acting on the patella were calculated. Results: The results showed that the forces acting on the patella were directly proportional to the knee flexion angle. The results also showed that the knee flexion angle does not always correspond with the angle set at the knee brace; however they did exhibit a direct relationship. Conclusion: Our findings show that, for partially weight bearing patella fractures, the optimum form of splintage corresponds with a low knee flexion angle


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 358 - 358
1 May 2009
Thorpe B Phyo N Lee A
Full Access

Background: Patella tendonitis is a condition often found in athletes but is also found in less active patients. It usually responds to conservative management (rest, physiotherapy and anti-inflammatory drugs) but some progress to surgery. A retrospective study was done to look at the results of this surgery in our hospital. Patients and Methods: From 2001 to 2007, nineteen knees in sixteen patients had open patella tendon decompression. Eleven patients were still involved in sporting activity. All surgery was performed by the same surgeon. The patients were brought back to a clinic for review, examination and VISA score. Results: All but one patient had an improvement in their pain score. Of the 11 patients that played sport, eight were able to return to sport. Five of these returned to competition. Five patients would not have the surgery again. Only two of these had still played sport. Three of these had other knee pathology found at arthroscopy. Conclusions: The results of the surgery were satisfactory, although they were more favourable in the patients that were still involved in sporting activities. The rehabilitation time was much longer than had been expected by most patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 29 - 29
7 Aug 2023
Mayne A Rajgor H Munasinghe C Agrawal Y Pagkalos I Davis E Sharma A
Full Access

Abstract. Introduction. There is growing interest in the use of robotic Total Knee Arthroplasty (TKA) to improve accuracy of component positioning. This is the first study to investigate the radiological accuracy of implant component position using the ROSA® knee system with specific reference to Joint Line Height, Tibial Slope, Patella Height and Posterior Condylar Offset. As secondary aims we compared accuracy between image-based and imageless navigation, and between implant designs (Persona versus Vanguard TKA). Methodology. This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive TKAs performed by a high volume surgeon using the ROSA® knee system. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to Joint Line Height, Tibial Slope, Patella Height (using the Insall-Salvati ratio) and Posterior Condylar Offset. Results. Mean age of patients undergoing ROSA TKA was 70 years (range, 55 to 95 years). Mean difference in joint line height between pre and post-operative radiographs was 0.2mm (range −1.5 to +1.8mm, p<0.05), posterior condylar offset mean change 0.16mm (range −1.4 to +1.3mm, p<0.05), tibial slope mean change 0.1 degrees (p<0.05) and patella height mean change 0.02 (range −0.1 to +0.1 p<0.05). No significant differences were found between imageless and image-based groups, or between implant designs (Persona versus Vanguard). Conclusion. This study validates the use of the ROSA® knee system in accurately restoring Joint Line Height, Patella Height and Posterior Condylar Offset


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims. The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources. Methods. Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction. Results. Since 2016, 301/7350 TKAs (4.1%) in 290 patients at our institution were discharged on the day of surgery. Mean follow-up was 31.4 months (6.2 to 70.0). In all, 28 patients (9.3%) attended the emergency department or other acute care settings within 90 days of surgery, most often with wound concerns or leg swelling; six patients (2.0%) were readmitted. No patients underwent a subsequent revision procedure, and there were no periprosthetic infections. Two patients (0.7%) underwent secondary patella resurfacing, and one patient underwent arthroscopic arthrolysis after previous manipulation under anaesthetic (MUA). Three patients (1.0%) underwent MUA alone. Primary care consultation records, available for 206 patients, showed 16 patients (7.8%) contacted their general practitioner within two weeks postoperatively; two (1.0%) were referred to secondary care. Overall, 115/121 patients (95%) telephoned stated they would have day-case TKA again. Conclusion. Day-case TKA can be safely delivered in the NHS with no additional resources. We found low incidence of contact with primary and secondary care in the postoperative period, and high patient satisfaction. Cite this article: Bone Jt Open 2023;4(8):621–627


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 127 - 127
1 Jun 2018
Vince K
Full Access

“The shortest distance between two points is a straight line.” This explains many cases of patellar maltracking, when the patellar track is visualised in three dimensions. The three-dimensional view means that rotation of the tibia and femur during flexion and extension, as well as rotational positioning of the tibial and femoral components are extremely important. As the extensor is loaded, the patella tends to “center” itself between the patellar tendon and the quadriceps muscle. The patella is most likely to track in the trochlear groove IF THE GROOVE is situated where the patella is driven by the extensor mechanism: along the shortest track from origin to insertion. Attempts to constrain the patella in the trochlear groove, if it lies outside that track, are usually unsuccessful. Physiologic mechanisms for tibial-femoral rotation that benefit patellar tracking (“screw home” and “asymmetric femoral roll-back”) are not generally reproduced. Practical Point. A patellofemoral radiograph that shows the tibial tubercle, illustrates how the tubercle, and with it the patellar tendon and patella itself, are all in line with the femoral trochlea. To accomplish this with a TKA, the femoral component is best rotated to the transepicondylar axis (TEA) and the tibial component to the tubercle. In this way, when the femoral component sits in its designated location on the tibial polyethylene, the trochlear groove will be ideally situated to “receive” the patella. Knee Mechanics. Six “degrees of freedom” refers to translation and rotation on three axes (x,y,z). This also describes how arthroplasty components can be positioned at surgery. The significant positions of tibial, femoral and patellar components are: 1. Internal-external rotation (around y-axis) and 2. Varus-valgus rotation (around z axis). 3. Medial-lateral translation (on x-axis). The other positional variables are less important for patella tracking. Biomechanical analyses of knee function are often broken down into: i. Extensor power analysis (y-z or sagittal plane) and ii. Tracking (x-y or frontal plane). These must be integrated to include the effects of rotation and to better understand patellar tracking. Effect of Valgus. Frontal plane alignment is important but less likely to reach pathological significance for patellar tracking than rotational malposition clinically. For example if a typical tibia is cut in 5 degrees of unintended mechanical valgus, this will displace the foot about 5 cm laterally but the tibial tubercle only 8 mm laterally. An excessively valgus tibial cut will not displace the tubercle and the patella as far as mal-rotation of the tibial component. Effect of Internal Rotation of Tibial Component. By contrast, internal rotation of the tibial component by 22 degrees, which is only 4 degrees in excess of what has been described as tolerable by Berger and Rubash, displaces the tubercle 14 mm, a distance that would place the center of most patella over the center of the lateral femoral condyle, risking dislocation. Dynamically, as the knee flexes, if the tibia is able to rotate externally this forces the tubercle into an even more lateral position, guaranteeing that the patella will align lateral to the tip of the lateral femoral condyle, and dislocate. The design of femoral components, in particular the varus-valgus angle of the trochlear groove, has an effect on patellar tracking. This effect will be accentuated by the surgical alignment technique of the femoral and tibial components. Component positions that mimic the orientation of the normal anatomy usually include more valgus alignment of the femoral component. This rotates the proximal “entrance” of the femoral trochlear groove more medially, making it more difficult for the patella to descend in the trochlear groove


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 69 - 69
7 Aug 2023
Kumar A Stevens S Jonas S White S Agarwal S
Full Access

Abstract. Introduction. Isolated patellofemoral joint(PFJ) osteoarthritis affects approximately 10% of patients aged over 40 years and treatment remains controversial. Our aim was to evaluate long term functional and radiological outcomes following PFJ arthorplasty with the Femoro Patella Vialli (FPV) prosthesis as this evidence is lacking in literature. Methodology. A retrospective review of prospectively collected PROMS in patients undergoing Patellofemoral arthroplasty. Single centre trial. Between 2004 and 2008, 101 FPV patellofemoral arthroplasties were performed in 80 patients with isolated patellofemoral joint osteoarthritis. Data was collected as a part of routine follow-up for up to 6 years and additional long term data was collected at 16 years. Results. At 6 year follow up the mean OKS was 29 and by 16 year follow up it was 26 which was not a statistically significant drop. 22 patients (29 knees) had died, 32 (32%) had been revised, 25 to total knee replacement using primary arthroplasty components. Mean OKS in the revised group was 27 which was not a statistically significant difference when compared to the unrevised group. Mean time to revision was 4 years. The cumulative survival analysis of the FPV implant was 76% at 5 years, 64% at 10 years. Conclusion. Our findings suggest the FPV patellofemoral prosthesis provides good pain relief and clinical outcomes however, the survivorship for this particular implant maybe lower as compared to the available literature. Patient reported outcomes are maintained over the implant life and are no worse once revised implying a staged approach to arthroplasty is reasonable