Advertisement for orthosearch.org.uk
Results 1 - 20 of 79
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 341 - 351
1 Mar 2022
Fowler TJ Aquilina AL Reed MR Blom AW Sayers A Whitehouse MR

Aims. Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA. Methods. We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were operating surgeon grade (consultant or trainee) and whether or not trainees were directly supervised by a scrubbed consultant. Outcomes were all-cause revision and the indication for revision up to ten years. We used methods of survival analysis, adjusted for patient, operation, and healthcare setting factors. Results. We included 603,474 THAs, of which 58,137 (9.6%) procedures were performed by a trainee. There was no association between surgeon grade and all-cause revision up to ten years (crude hazard ratio (HR) 1.00 (95% confidence interval (CI) 0.94 to 1.07); p = 0.966), a finding which persisted with adjusted analysis. Fully adjusted analysis demonstrated an association between trainees operating without scrubbed consultant supervision and an increased risk of all-cause revision (HR 1.10 (95% CI 1.00 to 1.21); p = 0.045). There was an association between trainee-performed THA and revision for instability (HR 1.14 (95% CI 1.01 to 1.30); p = 0.039). However, this was not observed in adjusted models, or when trainees were supervised by a scrubbed consultant. Conclusion. Within the current training system in England and Wales, appropriately supervised trainees achieve comparable THA survival to consultants. Trainees who are supervised by a scrubbed consultant achieve superior outcomes compared to trainees who are not supervised by a scrubbed consultant, particularly in terms of revision for instability. Cite this article: Bone Joint J 2022;104-B(3):341–351


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1669 - 1677
1 Nov 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims. To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. Methods. The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. Results. The distribution of acetabular component geometries was: LPW 81.2%; hooded 18.7%; and offset reorientating 0.1%. There were 3,313 (1.5%) revision THAs performed, of which 815 (0.4%) were for instability and 838 (0.4%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.31 (p < 0.001) and 4.12 (p = 0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.65 (p < 0.001) in the hooded group and 13.61 (p < 0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first three months. Conclusion. This registry-based study confirms a significantly higher risk of revision after cemented THA for instability and for loosening when a hooded or offset reorientating acetabular component is used, compared to a LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice. Cite this article: Bone Joint J 2021;103-B(11):1669–1677


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 35 - 35
7 Jun 2023
Warder H Sanders T Wright N Hall-Thompson B Alford S Johnson D
Full Access

Climbers and mountaineers will present to arthroplasty surgeons in need of hip replacement surgeries. There is a lack of guidance for both parties with a paucity in the literature. Climbing is often considered a high-risk activity to perform with a total hip replacement, due to the positions the hip is weighted in, and the potential austere environment in which an injury may occur. The aim was to assess levels of climbing and mountaineering possible following hip arthroplasty, and any factors affecting these levels. Ethical approval was obtained from the University of Central Lancashire. An anonymous online questionnaire was disseminated via email, social media and word-of-mouth to include all climbers, hill-walkers or mountaineers across the UK. This was used to collect climbing and mountaineering ability at various timepoints, along with scores such as the Oxford Hip Score and UCLA Score. The Kappa statistic was used to assess for correlations. Of the responders, 28 had undergone right hip arthroplasty surgery, with 11 having left hips and 22 receiving bilateral hips. A total of 67 of the replaced hips were total hip replacements, with 16 having undergone hip resurfacing. There is a fair agreement in level of climbing ability 3 months pre- and 3 months post-operatively (kappa=0.287, p<0.001), and a substantial agreement between 1 year post-operatively and currently for both climbing (kappa=0.730, p<0.001) and mountaineering (kappa=0.684, p<0.001). Impressively, 17 participants are climbing at more than E1 trad or 6c sport at one or more time points post operatively, which is regarded as an advanced level within the climbing community. Out of those 17 participants, 8 were climbing at this level within 3 months post-operatively. The level of climbing possible following hip arthroplasty surgery is above what is expected and perhaps desired by the operating surgeon. It is essential to take the individual patient into account when planning an operative intervention such as arthroplasty. The one year post-operative time point is highly predictive of longer term outcomes for both climbing and mountaineering


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 61 - 61
2 May 2024
Shah JZ Bubak S Sami WA Quraishi S
Full Access

Alcohol hand rubs, endorsed by WHO and NICE guidelines, are integral to modern surgical practices. Our objective was to assess how different scrubbing methods impact overall water usage by the surgical team, shedding light on variations among team members and their environmental implications. Over three consecutive arthroplasty lists spanning a week, water usage during scrubbing was observed for the operating team. Blinding all team members, including the anesthetist, consultant surgeon, orthopaedic registrar, orthopaedic SHO, and scrub nurse, during water usage calculations was implemented. Automated taps, using motion sensors, posed a challenge due to variable water quantity, necessitating water flow calculations per sensor movement. The senior surgeon, with over 20 years of experience, follows a traditional approach, starting with a morning prescrub and using an alcohol tub for each case, except when hands are soiled. We observed a total of 14 cases of lower limb primary arthroplasty. The cumulative water usage for scrubbing by the entire team was 193 liters, yielding a mean of 13.8 liters (±1.85) per case. The anaesthetist demonstrated the most conservative water usage, utilizing a total of 11.85 liters with a mean of 0.84 liters per case. Notably, alcohol rub was employed for half of the observed time, contributing to this efficient use. The senior operating surgeon used a total of 15.6 liters, averaging 1.1 liters per case. In contrast, the SHO and the registrar exhibited the highest water consumption, totaling 121.6 liters and yielding a mean of 5.7 liters per case. The nurses’ collective water usage for scrubbing amounted to 44.8 liters. Adopting alcohol rub, as endorsed by WHO, results in a remarkable 10-fold reduction in water usage, aligning with global health guidelines. This highlights significant potential for resource conservation in surgical procedures, presenting a practical and environmentally conscious approach to surgical scrubbing practices


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 32 - 32
7 Jun 2023
Howgate D Roberts PG Palmer A Price A Taylor A Rees J Kendrick B
Full Access

Primary total hip replacement (THR) is a successful and common operation which orthopaedic trainees must demonstrate competence in prior to completion of training. This study aimed to determine the impact of operating surgeon grade and level of supervision on the incidence of 1-year patient mortality and all-cause revision following elective primary THR in a large UK training centre. National Joint Registry (NJR) data for all elective primary THR performed in a single University Teaching Hospital from 2005–2020 were used, with analysis performed on the 15-year dataset divided into 5-year temporal periods (B1 2005–2010, B2 2010–2015, B3 2015–2020). Outcome measures were mortality and revision surgery at one year, in relation to lead surgeon grade, and level of supervision for trainee-led operations. 9999 eligible primary THR were undertaken, of which 5526 (55.3%) were consultant led (CL), and 4473 (44.7%) trainees led (TL). Of TL, 2404 (53.7%) were non-consultant supervised (TU), and 2069 (46.3%) consultant supervised (TS). The incidence of 1-year patient mortality was 2.05% (n=205), and all-cause revision was 1.11% (n=111). There was no difference in 1-year mortality between TL (n=82, 1.8%) and CL (n=123, 2.2%) operations (p=0.20, OR 0.78, CI 0.55–1.10). The incidence of 1-year revision was not different for TL (n=56, 1.3%) and CL (n=55, 1.0%) operations (p=0.15, OR 1.37, CI 0.89–2.09). Overall, there was no temporal change for either outcome measure between TL or CL operations. A significant increase in revision within 1-year was observed in B3 between TU (n=17, 2.7%) compared to CL (n=17, 1.0%) operations (p=0.005, OR 2.81, CI 1.35–5.87). We found no difference in 1-year mortality or 1-year all-cause revision rate between trainee-led primary THR and consultant-led operations over the entire fifteen-year period. However, unsupervised trainee led THR in the most recent 5-year block (2015–2020) has a significantly increased risk of early revision, mainly due to instability and prosthetic joint infection. This suggests that modern surgical training is having a detrimental effect on THR patient outcomes. More research is needed to understand the reasons if this trend is to be reversed


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 20 - 20
1 Jul 2020
Fowler T Aquilina A Blom A Sayers A Whitehouse M
Full Access

Aims. The aim of this study was to conduct evidence synthesis on the available published literature of the impact of the training status of the operating surgeon (trainee vs. consultant) on the survival and revision rate of primary hip and knee replacements. Patients and Methods. We conducted a systematic review according to Cochrane guidelines. Separate searches were performed for hip and knee replacements, with meta-analysis and presentation of results in parallel. We searched MEDLINE and Embase databases from inception to 17 September 2019 and included controlled trials and cohort studies reporting implant survival estimates, or revision rates of hip and knee replacements according to the grade of the operating surgeon. This study was registered with PROSPERO (CRD42019150494). Results. 8 studies (5 hip papers and 3 knee papers) met the inclusion criteria. There was no significant difference in the survival estimates for total hip replacements (THRs) performed by trainees compared to consultants at 5-years follow-up (97.9% vs 98.1%, p = 0.74). Furthermore, there was no significant difference in the revision rate of THRs performed by trainees and consultants at both 5 and 10-year intervals of follow-up (relative risk [RR]: 5yrs = 0.88 (95% CI: 0.46, 1.70; P = 0.71); 10yrs = 0.68 (95% CI: 0.37, 1.26; P = 0.22)). There was no significant difference in the survival estimates at 10-years for total knee replacements (TKRs) performed by trainees compared to consultants (96.2% vs 95.1%, p=0.49). Conclusion. There is no evidence in the existing literature that trainee surgeons have worse outcomes than their consultant colleagues, in terms of the survival, or rate of revision of hip and knee replacements at 5–10 years follow-up. This may mean that there is genuinely no difference or that, in the context of contemporary training programmes, appropriate case-mix selection and supervision of trainees is currently employed


Cemented acetabular components commonly have a long posterior wall (LPW). Alternative components have a hooded or offset reorientating geometry, theoretically to reduce the risk of THR instability. We aimed to determine if cemented acetabular component geometry influences the risk of revision surgery for instability or loosening. The National Joint Registry for England, Wales and Northern Ireland (NJR) dataset was analysed for primary THAs performed between 2003 – 2017. A cohort of 224,874 cemented acetabular components were identified. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using binomial regression adjusting for age, gender, ASA grade, diagnosis, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking and head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. Among the cohort of subjects included, the distribution of acetabular component geometries was: LPW – 81.2%, hooded – 18.7% and offset reorientating – 0.1%. There were 3,313 (1.47%) revision THAs performed, of which 815 (0.36%) were for instability and 838 (0.37%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.29 (p<0.001) and 4.12 (p=0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.43 (p<0.001) in the hooded group and 11.47 (p<0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first 6 months. This Registry based study confirms a significantly higher risk of revision THA for instability and for loosening when a cemented hooded or offset reorientating acetabular component is used, compared to an LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 20 - 20
1 Aug 2021
Palmer J Fraig H Wilson C Garrett S
Full Access

Noise induced hearing loss (NIHL) is a common cause of preventable deafness in adults and exposure to loud noise at work is a significant risk factor for its development. In order to protect the hearing of workers in the U.K., the Health and Safety Executive (HSE), on behalf of the Department for Work and Pensions, established the Control of Noise at Work Regulations (2005). The objectives of this study were to define the levels of noise exposure for the surgeon, assistant, scrub nurse and anaesthetist during total hip and knee arthroplasty surgery. In addition, we sought to determine whether the noise exposure during these procedures reaches or exceeds the action values set out by the U.K. Noise at Work Regulations (2005). To our knowledge no real-time assessment of personal noise exposure has been performed simultaneously on multiple members of the theatre team during arthroplasty surgery. Individual noise exposure during arthroplasty hip and knee surgery was recorded using a personal noise dosemeter system model 22 (DM22) (Pulsar instruments, Filey, U.K.). Recordings were taken real-time during five separate theatre sessions. Each theatre session included two arthroplasty procedures and lasted approximately 4hrs. Personal noise exposure was expressed in terms of peak sound pressure and an average noise exposure over an 8-hour time-period to reflect the noise experienced by the ear over a working day. In all three sessions involving total hip replacement surgery the peak sound pressure, for the operating surgeon, exceeded the exposure action values set out by the U.K. Noise at Work Regulations. Theatre sessions involving total knee replacement surgery did not exceed any exposure action values. The peak sound pressures experienced during total hip replacement surgery are too high and mandate that the surgeon should be provided with appropriate hearing protection. In addition, if the upper exposure action value is routinely exceeded then the theatre should be designated a hearing protection zone


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 3 - 3
1 Jul 2020
Chan G Aladwan R Hook S Rogers B Ricketts D Stott P
Full Access

Introduction. Dislocated hip hemiarthroplasties (HA) are associated with a 45% revision rate and 40% mortality rate. Implant selection for HA operations vary with no universally accepted implant choice. The WHiTE3 trial suggested older designs such as the Thompson has equitable outcomes to more modern and expensive implants such as the Exeter V40+Unitrax. Our multi-centre consecutive series of NOFs patients treated with HA assesses the impact of surgical and patient factors on dislocation risk. Methods. Medical and radiographic records for patients treated between 1. st. January 2009 and 30. th. September 2017 with a HA at three acute hospitals were reviewed. Implant and dislocation data were recorded. Patient demographics, comorbidities and operation details were extracted from the medical records and NHFD. Patients were excluded if there were no postoperative radiographs or when HA had been performed as a revision procedure. Results. We identified 4305 consecutive patients with 189 excluded. There was no difference in patient characteristics between the hospitals or implant types (p>0.05). Four HA implants were used during the study period; Thompson, Austin-Moore, Furlong and Exeter V40+Unitrax. 63 dislocations were identified (1.5%), median time to dislocation was 24 days. Dislocation rates for Thompson HAs were significantly higher (p=0.004) at 3.7%. No association was demonstrated with cemented versus uncemented, bipolar versus monopolar, fixed versus variable offsets, operating surgeon grade and dislocation rates (p>0.05). Patient factors (preoperative AMTS, postoperative AMTS, preoperative mobility and ASA grade) had no effect on dislocation (p>0.05). Discussion. Our study which is reflective current implant choices, demonstrates that Thompson implants for HA after NOFs have a significantly higher dislocation rates than other common prostheses, and their continued use should be reconsidered. This effect has not been demonstrated in previous studies. Patient, implant construct and surgeon factors had little bearing on the subsequent dislocation rate


Bone & Joint Open
Vol. 4, Issue 6 | Pages 416 - 423
2 Jun 2023
Tung WS Donnelley C Eslam Pour A Tommasini S Wiznia D

Aims

Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model.

Methods

A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 79 - 86
10 Feb 2023
McLaughlin JR Johnson MA Lee KR

Aims

The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA).

Methods

The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims

United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures.

Methods

A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 370 - 377
19 May 2023
Comeau-Gauthier M Bzovsky S Axelrod D Poolman RW Frihagen F Bhandari M Schemitsch E Sprague S

Aims

Using data from the Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemiarthroplasty (HEALTH) trial, we sought to determine if a difference in functional outcomes exists between monopolar and bipolar hemiarthroplasty (HA).

Methods

This study is a secondary analysis of patients aged 50 years or older with a displaced femoral neck fracture who were enrolled in the HEALTH trial and underwent monopolar and bipolar HA. Scores from the Western Ontario and McMaster University Arthritis Index (WOMAC) and 12-Item Short Form Health Survey (SF-12) Physical Component Summary (PCS) and (MCS) were compared between the two HA groups using a propensity score-weighted analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 124 - 134
1 Feb 2023
Jain S Farook MZ Aslam-Pervez N Amer M Martin DH Unnithan A Middleton R Dunlop DG Scott CEH West R Pandit H

Aims

The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA).

Methods

Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 867 - 876
10 Nov 2022
Winther SS Petersen M Yilmaz M Kaltoft NS Stürup J Winther NS

Aims

Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS).

Methods

Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 26 - 26
1 Jun 2016
Abbas G Mullins M Dodd M Woodnutt D
Full Access

Press-fit fixation of uncemented acetabular components is increasingly being used for total hip replacement (THR) surgery. This study was aimed to analyse the survival of an established, un-cemented flexible metal backed cup with non-highly cross-linked polyethylene in primary and simple revision THR. We assessed the outcome of 1703 consecutive cementless elastic acetabular cups (Atlas, FH France) with non-highly cross-linked polyethylene (GUR1030) in total hip replacement surgery. There were 1582 patients (513 males and 1079 females) with mean age of 74 years (36–97 years). Seventeen senior operating surgeons accounted for 88.5% of cases from a single arthroplasty unit. Survival analysis was calculated using the Kaplan Meier Estimator. At 184 months post surgery the survivorship was 92.4% (95% CI 88.3–94.7) with cup revision for any cause as an endpoint. Three patients died within first month of surgery and 268 patients (17.13%) died due to unrelated causes. Overall, 59 patients had revisions (3.5%), Thirty eight patients (2.3%) were due to acetabular causes such as: aseptic loosening in 6 patients (0.35%); hip instability in 13 patients (0.76%); and deep infection in 11 patients (0.64%). We believe the cementless elastic acetabular cup on in total hip replacement is tolerant of technique and patient variation and continues to give excellent long-term results and its continued widespread use can be recommended


Bone & Joint Open
Vol. 3, Issue 3 | Pages 182 - 188
1 Mar 2022
Boktor J Badurudeen A Rijab Agha M Lewis PM Roberts G Hills R Johansen A White S

Aims

In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures.

Methods

This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1774 - 1782
1 Dec 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims

The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening.

Methods

A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 708 - 714
1 Jun 2008
McBryde CW Shears E O’Hara JN Pynsent PB

Metal-on-metal hip resurfacing was performed for developmental dysplasia in 96 hips in 85 patients, 78 in women and 18 in men, with a mean age at the time of surgery of 43 years (14 to 65). These cases were matched for age, gender, operating surgeon and date of operation with a group of patients with primary osteoarthritis who had been treated by resurfacing, to provide a control group of 96 hips (93 patients). A clinical and radiological follow-up study was performed. The dysplasia group were followed for a mean of 4.4 years (2.0 to 8.5) and the osteoarthritis group for a mean of 4.5 years (2.2 to 9.4). Of the dysplasia cases, 17 (18%) were classified as Crowe grade III or IV. There were five (5.2%) revisions in the dysplasia group and none in the osteoarthritic patients. Four of the failures were due to acetabular loosening and the other sustained a fracture of the neck of femur. There was a significant difference in survival between the two groups (p = 0.02). The five-year survival was 96.7% (95% confidence interval 90.0 to 100) for the dysplasia group and 100% (95% confidence interval 100 to 100) for the osteoarthritic group. There was no significant difference in the median Oxford hip score between the two groups at any time during the study. The medium-term results of metal-on-metal hip resurfacing in all grades of developmental dysplasia are encouraging, although they are significantly worse than in a group of matched patients with osteoarthritis treated in the same manner