Aims. Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA. Methods. We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were
Aims. To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. Methods. The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type,
Climbers and mountaineers will present to arthroplasty surgeons in need of hip replacement surgeries. There is a lack of guidance for both parties with a paucity in the literature. Climbing is often considered a high-risk activity to perform with a total hip replacement, due to the positions the hip is weighted in, and the potential austere environment in which an injury may occur. The aim was to assess levels of climbing and mountaineering possible following hip arthroplasty, and any factors affecting these levels. Ethical approval was obtained from the University of Central Lancashire. An anonymous online questionnaire was disseminated via email, social media and word-of-mouth to include all climbers, hill-walkers or mountaineers across the UK. This was used to collect climbing and mountaineering ability at various timepoints, along with scores such as the Oxford Hip Score and UCLA Score. The Kappa statistic was used to assess for correlations. Of the responders, 28 had undergone right hip arthroplasty surgery, with 11 having left hips and 22 receiving bilateral hips. A total of 67 of the replaced hips were total hip replacements, with 16 having undergone hip resurfacing. There is a fair agreement in level of climbing ability 3 months pre- and 3 months post-operatively (kappa=0.287, p<0.001), and a substantial agreement between 1 year post-operatively and currently for both climbing (kappa=0.730, p<0.001) and mountaineering (kappa=0.684, p<0.001). Impressively, 17 participants are climbing at more than E1 trad or 6c sport at one or more time points post operatively, which is regarded as an advanced level within the climbing community. Out of those 17 participants, 8 were climbing at this level within 3 months post-operatively. The level of climbing possible following hip arthroplasty surgery is above what is expected and perhaps desired by the
Alcohol hand rubs, endorsed by WHO and NICE guidelines, are integral to modern surgical practices. Our objective was to assess how different scrubbing methods impact overall water usage by the surgical team, shedding light on variations among team members and their environmental implications. Over three consecutive arthroplasty lists spanning a week, water usage during scrubbing was observed for the operating team. Blinding all team members, including the anesthetist, consultant surgeon, orthopaedic registrar, orthopaedic SHO, and scrub nurse, during water usage calculations was implemented. Automated taps, using motion sensors, posed a challenge due to variable water quantity, necessitating water flow calculations per sensor movement. The senior surgeon, with over 20 years of experience, follows a traditional approach, starting with a morning prescrub and using an alcohol tub for each case, except when hands are soiled. We observed a total of 14 cases of lower limb primary arthroplasty. The cumulative water usage for scrubbing by the entire team was 193 liters, yielding a mean of 13.8 liters (±1.85) per case. The anaesthetist demonstrated the most conservative water usage, utilizing a total of 11.85 liters with a mean of 0.84 liters per case. Notably, alcohol rub was employed for half of the observed time, contributing to this efficient use. The senior
Primary total hip replacement (THR) is a successful and common operation which orthopaedic trainees must demonstrate competence in prior to completion of training. This study aimed to determine the impact of
Aims. The aim of this study was to conduct evidence synthesis on the available published literature of the impact of the training status of the
Cemented acetabular components commonly have a long posterior wall (LPW). Alternative components have a hooded or offset reorientating geometry, theoretically to reduce the risk of THR instability. We aimed to determine if cemented acetabular component geometry influences the risk of revision surgery for instability or loosening. The National Joint Registry for England, Wales and Northern Ireland (NJR) dataset was analysed for primary THAs performed between 2003 – 2017. A cohort of 224,874 cemented acetabular components were identified. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using binomial regression adjusting for age, gender, ASA grade, diagnosis, side, institution type,
Noise induced hearing loss (NIHL) is a common cause of preventable deafness in adults and exposure to loud noise at work is a significant risk factor for its development. In order to protect the hearing of workers in the U.K., the Health and Safety Executive (HSE), on behalf of the Department for Work and Pensions, established the Control of Noise at Work Regulations (2005). The objectives of this study were to define the levels of noise exposure for the surgeon, assistant, scrub nurse and anaesthetist during total hip and knee arthroplasty surgery. In addition, we sought to determine whether the noise exposure during these procedures reaches or exceeds the action values set out by the U.K. Noise at Work Regulations (2005). To our knowledge no real-time assessment of personal noise exposure has been performed simultaneously on multiple members of the theatre team during arthroplasty surgery. Individual noise exposure during arthroplasty hip and knee surgery was recorded using a personal noise dosemeter system model 22 (DM22) (Pulsar instruments, Filey, U.K.). Recordings were taken real-time during five separate theatre sessions. Each theatre session included two arthroplasty procedures and lasted approximately 4hrs. Personal noise exposure was expressed in terms of peak sound pressure and an average noise exposure over an 8-hour time-period to reflect the noise experienced by the ear over a working day. In all three sessions involving total hip replacement surgery the peak sound pressure, for the
Introduction. Dislocated hip hemiarthroplasties (HA) are associated with a 45% revision rate and 40% mortality rate. Implant selection for HA operations vary with no universally accepted implant choice. The WHiTE3 trial suggested older designs such as the Thompson has equitable outcomes to more modern and expensive implants such as the Exeter V40+Unitrax. Our multi-centre consecutive series of NOFs patients treated with HA assesses the impact of surgical and patient factors on dislocation risk. Methods. Medical and radiographic records for patients treated between 1. st. January 2009 and 30. th. September 2017 with a HA at three acute hospitals were reviewed. Implant and dislocation data were recorded. Patient demographics, comorbidities and operation details were extracted from the medical records and NHFD. Patients were excluded if there were no postoperative radiographs or when HA had been performed as a revision procedure. Results. We identified 4305 consecutive patients with 189 excluded. There was no difference in patient characteristics between the hospitals or implant types (p>0.05). Four HA implants were used during the study period; Thompson, Austin-Moore, Furlong and Exeter V40+Unitrax. 63 dislocations were identified (1.5%), median time to dislocation was 24 days. Dislocation rates for Thompson HAs were significantly higher (p=0.004) at 3.7%. No association was demonstrated with cemented versus uncemented, bipolar versus monopolar, fixed versus variable offsets,
Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model. A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed.Aims
Methods
The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four.Aims
Methods
United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.Aims
Methods
Using data from the Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemiarthroplasty (HEALTH) trial, we sought to determine if a difference in functional outcomes exists between monopolar and bipolar hemiarthroplasty (HA). This study is a secondary analysis of patients aged 50 years or older with a displaced femoral neck fracture who were enrolled in the HEALTH trial and underwent monopolar and bipolar HA. Scores from the Western Ontario and McMaster University Arthritis Index (WOMAC) and 12-Item Short Form Health Survey (SF-12) Physical Component Summary (PCS) and (MCS) were compared between the two HA groups using a propensity score-weighted analysis.Aims
Methods
The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.Aims
Methods
Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.Aims
Methods
Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS). Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).Aims
Methods
Press-fit fixation of uncemented acetabular components is increasingly being used for total hip replacement (THR) surgery. This study was aimed to analyse the survival of an established, un-cemented flexible metal backed cup with non-highly cross-linked polyethylene in primary and simple revision THR. We assessed the outcome of 1703 consecutive cementless elastic acetabular cups (Atlas, FH France) with non-highly cross-linked polyethylene (GUR1030) in total hip replacement surgery. There were 1582 patients (513 males and 1079 females) with mean age of 74 years (36–97 years). Seventeen senior
In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.Aims
Methods
The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries.Aims
Methods
Metal-on-metal hip resurfacing was performed for developmental dysplasia in 96 hips in 85 patients, 78 in women and 18 in men, with a mean age at the time of surgery of 43 years (14 to 65). These cases were matched for age, gender,