At the end of 2018, the NZ
Electronic Health Records (EHRs) have benefits for hospitals and uptake in the UK is increasing. The National
There is paucity of reliable data examining the treatment pathway for hip replacements over the life of the patient in terms of risk of revision and re-revisions. We did a retrospective observational registry-based study of the National
Hip bearing surfaces materials are typically broadly reported in national registry (metal-on-polyethylene, ceramic-on-ceramic etc). We investigated the revision rates of primary total hip replacement (THR) reported in the National
We investigated the revision rates of primary total hip replacement (THR) reported in the National
Ceramic on ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National
A recent French report suggested that cobalt metal ions released from total hip replacements (THRs) were associated with an increased risk of dilated cardiomyopathy and heart failure. If the association is causal the consequences would be significant given the millions of Orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome containing THRs were associated with an increased risk of all-cause mortality, heart failure, cancer, and neurodegenerative disorders. Data from the National
Background. Method of fixation in THA is a contentious issue, with proponents of either technique citing improved implant survival and outcomes. Current comparisons rely on insufficiently powered studies with short-term follow up or larger poorly controlled registry studies. Patient factors are considered a key variable contributing to the risk of implant failure. One way to overcome this confounder is to compare the survival of cementless and cemented THAs patients who have undergone bilateral THAs with cemented hip on one side and cementless hip on the other. We compared stem survival of patients who have bilateral THA with one cemented stem in one hip and a cementless stem in the contralateral hip in the National
Patients need to know the benefits, risks and alternatives to any proposed treatment. Surgeons discussing the risk of a revision procedure becoming necessary, after a hip replacement can draw upon the orthopaedic literature and arthroplasty registries for long-term implant survival. However, early revision is required in a minority of cases. We have investigated the probability for revision hip replacement patients in terms of time-point and indication for revision. Of the 9,411 Primary Total Hip Replacements (THR), undertaken by 22 surgeons, over an eleven-year period, between January 2004 and March 2015, 1.70% (160) were subsequently reported to the National
Current advice regarding implant choice is based on estimates of cost-benefit derived from implant survival to an endpoint of revision. Current estimates do not account for many implant failures which are treated with non-revision surgery and may not be accurate. The aim of this study was to estimate survival of major stem implant design groups to an endpoint of reoperation. Primary total hip replacement and linked revision form the National
Introduction. The National
Total hip arthroplasty has been constantly evolving with technological improvements to achieve the best survival rates. Although the new implants are under closer surveillance through processes such as Beyond Compliance, orthopaedic surgeons generally tend to look out for the latest implants with good short-term results and hope for better long-term results for these. We questioned whether such an assumption or bias is valid. We analysed the data of Kaplan-Meier estimates of cumulative revisions of primary hip replacement by fixation, stem/cup brand and bearing combinations from the NJR 19th Annual Report published in September 2022. We performed a univariate linear regression analysis to predict the 10- and 15-year revision rates for these different hip implant combinations from the 3- and 5-year revision rates. Thirty-seven implant combinations had their 15-year revision rates reported and 67 had the 10-year revision rates. The correlation co-efficients were 0.43 and 0.58 for the 3-year and 5-year revision rates against 15-year revision rates. Only 17% of the variance in 15-year revision rates could be predicted by a linear regression model from the 3-year revision rate and 32% from the 5-year revision rate. Corresponding values for the 10-year revision rates were 46% and 67%. 95% prediction intervals for the 15-year revision rate were +/− 3.1% from the 3-year revision rate and +/− 2.8% from the 5-year revision rate. Corresponding values for the 10-year revision rates were +/− 1.3% and +/− 1%. 19 of 37 implant combinations showed 15-year revision rate of more than 4%. Average 3-year and 5-year revision rates for this cohort was 1.0% and 1.42% compared to 1.4% and 1.9% for the rest and the difference was statistically significant. Although average early revision rates showed small but significant difference between the groups with lower and higher 15-year revision rates, the prediction intervals for 15-year revision rates for individual hips based on their 3-year and 5-year revision rates are very wide. Three- and 5-year revision rates for primary total hip replacements are poor predictors of 15-year revision rates.
Computer aided Total Hip Arthroplasty (THA) surgery is known to improve implantation precision, but clinical trials have failed to demonstrate an improvement in survivorship or patient reported outcome measures (PROMs). Our aim was to compare the risk of revision, PROMs and satisfaction rates between computer guided and THA implanted without computer guidance. We used the National
The aim of this study was to compare the relative performance of total hip replacement constructs and discern if there is substantial variability in performance in currently commonly used prostheses. All patients who underwent a primary total hip replacement (THR) registered in the NZJR between 1st January 1999 to June 2020 were identified. Using a noninferiority analysis, the performance of hip prostheses were compared with the best performing contemporary construct. Construct failure was estimated using the 1-Kaplan Meier survival function method to estimate net failure. The difference in failure between the contemporary benchmark and other constructs was examined. In total 135 432 THR were recorded comprising 1 035 different THR constructs. Notably 328 constructs were used just once. 48 constructs (62 251 THR) had >500 procedures at risk at 3 years post-primary of which 28 were inferior by at least 20% relative risk of which, 10 were inferior by at least 100% relative risk. 16 constructs were identified with >500 procedures at risk at 10 years with 9 inferior by at least 20%, of which one was inferior by >100% relative risk. There were fewer constructs noninferior to the best practice benchmark when we performed analysis by gender. In females at 10 years, from 5 constructs with >500 constructs at risk, 2 were inferior at the 20% margin. In males at 10 years, there were only 2 eligible constructs of which one was inferior at the 20% margin. We discerned that there is substantial variability in construct performance and at most time points, just over half of constructs are inferior to the best performing construct by at least 20%. These results can facilitate informed decision-making when considering THR surgery.
Whilst total hip replacement (THR) is generally safe and effective, pre-existing medical conditions, particularly those requiring inpatient admission, may increase the risk of post-operative mortality. Delaying elective surgery may reduce the risk, but it is unclear how long a delay is sufficient. We analysed 958,145 primary THRs performed for solely osteoarthritis April 2003-December 2018, in the NJR linked to Hospital Episodes Statistics to identify inpatient admissions prior to elective THR for 17 conditions making up the Charlson index including myocardial infarction, congestive heart failure, cerebrovascular disease and diabetes. Crude analyses used Kaplan-Meier and adjusted analyses used Cox modelling. Patients were categorised for each co-morbidity into one of four groups: not recorded in previous five-years, recorded between five-years and six-months before THR, recorded six-months to three-months before THR, and recorded between three-months and day before surgery. 90-day mortality was 0.34% (95%CI: 0.33–0.35). In the 432 patients who had an acute MI in the three months before THR, this figure increased to 18.1% (95%CI 14.8, 22.0). Cox models observed 63 times increased hazard of death within 90-days if patients had an acute MI in the 3-months before their THR, compared to patients who had not had an MI in the five years before their THR (HR 63.6 (95%CI 50.8, 79.7)) This association reduced as the time between acute MI and THR increased. For congestive cardiac failure, the hazard in the same scenario was 18-times higher with a similar protective effect of delaying surgery. Linked NJR and HES data demonstrate an association between inpatient admission for acute medical co-morbidities and death within 90-days of THR. This association is greatest in MI, congestive cardiac failure and cerebrovascular disease with smaller associations observed in several other conditions including diabetes. The hazard reduces when longer delays are seen between the admission for acute medical conditions and THR in all diagnoses. This information will help patients with previous medical admissions and surgeons to determine optimal timing for surgery.
The Exeter V40 femoral stem is the most implanted stem in the NJR for primary THA. In 2004, the 44/00/125 stem was released for use in “cement-in-cement” revision cases. It has however been used ‘off-label’ as a primary stem when, for example, patient anatomy requires a smaller stem with a 44mm offset. We aimed to investigate survival of this stem in comparison to others in the range when used in primary THAs recorded in the NJR. Analyses were performed using a dataset based on that used for the 2020 NJR annual report. Our exposure was the stem; the outcome was all-cause construct revision. Crude analyses were performed using Kaplan-Meier and adjusted using Cox models. The 44/00/125 stem was directly compared to other stems in the Exeter range. We analysed 330,732 primary THAs using the Exeter V40 stem comprising 34.5% of the 958,869 THAs with complete information from the start of the NJR to 31 December 2018. The 44/00/125 stem was implanted in 2,158 primary THAs with 67.5% in female patients and a mean age of 67.8. The 10-year revision estimate for the 44/00/125 stem was 4.9% (95%CI 3.6, 6.8) and in constructs using an Exeter V40 stem was 2.8% (95%CI 2.7, 2.8). Controlling for age, sex and ASA demonstrated an increased overall hazard of revision for constructs using the 44/00/125 stem compared to constructs using other Exeter V40 femoral stems (HR 1.8 (95%CI 1.4, 2.3)). Although the revision estimate is within the NICE 10-year benchmark, survivorship of constructs using the 44/00/125 stem appears to be lower than the rest of the Exeter V40 range. Attempts to control for age, sex and ASA will not take into account confounding by indication i.e. patients with more complex anatomy who may have a higher risk of revision. Surgeons and patients should be reassured by this but should be aware of the observed increased revision estimate and use the stem according to its indications.
Prosthetic joint infections (PJI) are a devastating consequence in total hip arthroplasties (THA) with both significant morbidity and sometimes mortality, posing a significant health economic burden. Studies, both clinical and in-vitro have suggested possible reduction in PJI with the use of ceramic bearings. We have investigated the relationship of ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP) or metal-on-polyethylene (MoP) bearing surface in affecting outcome of revision surgery after primary THA using data collected from National Joint Registry for England and Wales, Northern Ireland and the Isle of Man between 2002 and 2016. We used a competing risk regression model to investigate predictors of each revision outcome, such as infection, dislocation, aseptic revision and all cause revisions. The results were adjusted for age, gender, ASA grade, BMI, indication for surgery, intraoperative complications and implant data. We identified 456,457 THA (228,786 MoP, 128,403 CoC and 99,268 CoP). In a multivariable model, the adjusted risk of revision for PJI was lower with CoC (OR-0.748, p<0.001) and CoP (OR-0.775, p<0.001) when compared to MoP bearing. Additionally there was also a significant reduction in the risk of all cause revision for CoC (OR-0.918, p=0.002) and CoP (0.806, p<0.001), bearings as compared with MoP. The protective effect of ceramic bearing was predominantly seen after two years of implantation with a significant (p<0.0001) reduction of revision for PJI in both CoC (by 42.8%) and CoP (by 41.3%) group. Similarly significant effect was seen for aseptic revision beyond two years and overall all cause revision rate beyond two years reduced by 21.6% for CoC and 27.1% for CoP (p<0.001). Within the limits of registry analysis, this study has demonstrated an association between the use of ceramic bearing and lower rates of revision for all cause revisions especially infection and aseptic loosening. This finding supports the use of ceramic bearings in THA.
The National Joint Registry for England, Wales and Northern Ireland
(NJR) has extended its scope to report on hospital, surgeon and
implant performance. Data linkage of the NJR to the London Implant
Retrieval Centre (LIRC) has previously evaluated data quality for
hip primary procedures, but did not assess revision records. We analysed metal-on-metal hip revision procedures performed
between 2003 and 2013. A total of 69 929 revision procedures from
the NJR and 929 revised pairs of components from the LIRC were included.Aims
Methods
Total hip replacements (THRs) are performed by surgeons at various stages in their training, with varying levels of senior supervision. There is a balance between protecting training opportunities for the next generation of surgeons, while limiting the exposure of patients to unnecessary risk during the training process. The aim of this study was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THR. We included 603 474 primary THRs recorded in the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man (NJR) between 2003 and 2016 for an indication of osteoarthritis. Exposures were the grade of the surgeon (consultant or trainee), and whether trainees were supervised by a scrubbed consultant or not. Outcomes were all-cause revision, the indication for revision, and the temporal variation in risk of revision (all up to 10 years). Net failure was calculated using Kaplan-Meier analysis and adjusted analyses used Cox regression and flexible parametric survival analysis (adjusted for patient, operative, and unit level factors). There was no association between surgeon grade and all-cause revision up to 10 years (crude hazard ratio (HR) 0·999, 95% confidence interval (CI) 0.936–1.065; p=0.966); a finding which persisted with adjusted analysis. Adjusted analysis demonstrated an association between trainees operating without supervision by a scrubbed consultant and an increase in all-cause revision (HR 1.100, 95% CI 1.002–1.207; p=0.045). There was an association between the trainee-performed THRs and revision due to instability (crude HR 1.143, 95% CI, 1.007–1.298; p=0.039). However, this was not observed in fully adjusted models, or when trainees were supervised by a scrubbed consultant. Within the current training system in the United Kingdom, trainees achieve comparable outcomes to consultant surgeons when supervised by a scrubbed consultant. Revision rates are higher when trainees are not supervised by a scrubbed consultant but remain within internationally recognised acceptable limits.
THR is one of the most frequently performed operations nationally. A large number of prostheses are available, and the procedure is therefore associated with variation in practice and outcomes. NICE guidelines aim to standardise best practice, and are informed by separate, independent bodies, such as the NJR and ODEP, which monitor data about the implants used and their performance. This study aims to determine whether clinical practice and component use has changed since the publication of NJR data. NJR reports from 2006–2014 were analysed, with record made of the different prostheses used in THR, noting ODEP ratings of components used. Analysis was also performed by component type (i.e. cemented and cementless stems and cups), and combinations of components, according to their frequency of use in a given year. The Kruksal-Wallis test was used for statistical analysis.Introduction
Methods