Advertisement for orthosearch.org.uk
Results 1 - 20 of 42
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 688 - 695
1 Jun 2023
Johnston GHF Mastel M Sims LA Cheng Y

Aims. The aims of this study were to identify means to quantify coronal plane displacement associated with distal radius fractures (DRFs), and to understand their relationship to radial inclination (RI). Methods. From posteroanterior digital radiographs of healed DRFs in 398 female patients aged 70 years or older, and 32 unfractured control wrists, the relationships of RI, quantifiably, to four linear measurements made perpendicular to reference distal radial shaft (DRS) and ulnar shaft (DUS) axes were analyzed: 1) DRS to radial aspect of ulnar head (DRS-U); 2) DUS to volar-ulnar corner of distal radius (DUS-R); 3) DRS to proximal capitate (DRS-PC); and 4) DRS to DUS (interaxis distance, IAD); and, qualitatively, to the distal ulnar fracture, and its intersection with the DUS axis. Results. In the study (fracture) and control groups, respectively, the mean values were: RI, 17.2° (SD 7.2°; -7° to 35°) and 25.6° (SD 2.6°; 21° to 30°); DRS-U, 13.5 mm (SD 1.7; 4.9 to 20.8) and 15.3 mm (SD 0.72; 13.8 to 16.3); DUS-R, 13.4 mm (SD 2.1; 4.8 to 18.5) and 12.0 mm (SD 0.99; 9.7 to 13.9); DRS-PC (positive value radial to DRS, negative value ulnar), 0.14 mm (SD 5.4; -10.9 to 22.7) and -6.1 mm (SD 1.6; -10.6 to -2.3); and IAD, 25.3 mm (SD 2.5; 17.6 to 31.1) and 27.1 mm (SD 1.5; 24.5 to 31.0). All means were significantly different between the study and control groups. RI correlated strongly with DRS-PC. Ulnar styloid fracture intersection with the DUS axis, reflective of ulnar translation of both radial and ulnar shafts, was associated with significantly lower RI. Conclusion. After DRF, the relationship of the proximal capitate to the DRS axis in the coronal plane correlates with the final radial inclination. Additionally, ulnar styloid intersection with the DUS axis is associated with even lower radial inclination. DRF reduction should seek to restore the normal coronal relationship of both radial and ulnar shafts to their distal counterparts. Cite this article: Bone Joint J 2023;105-B(6):688–695


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 572 - 572
1 Sep 2012
Khan A Ebreo D El Meligy M Armstrong C Peter V
Full Access

Introduction. The advantages of metal on metal (MOM) hip replacement are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri prosthetic osteolysis generated as a result of a biological response to particulate wear debris. Our aim in this study was to determine whether a steeply inclined acetabular component would give rise to a higher concentration of metal ions. Patients and methods. Between April 2003 and June 2006, 22 patients had MOM hip replacement for osteoarthritis by a single Surgeon. There were 12 male and 10 female patients. The average age at the time of surgery was 56 years (Range: 44–69 years). We divided the 22 patients into 2 groups, one group (A) of 11 patients with the acetabular inclination angle more than 50 degrees and the other group (B) of 11 patients with the angle less than 50 degrees. The inclination of the acetabular cup was measured using a standard AP radiograph of the pelvis. The patients had metal ion levels (blood chromium and serum cobalt) measured at an average follow up of 3.2 years (Range 2.4 to 5 years). Results. Mean blood chromium level in the group A (146 nM/L) was significantly higher (p=0.005) than in Group B (92 nM/L). Mean serum cobalt level in the group A (245 nM/L) was significantly higher (p=0.002) than in Group B (110 nM/L). Discussion. The early to mid term published results of MOM hip replacements have been encouraging. There are, however, a number of concerns about the MOM bearing. Although its wear rate is low, it still releases metal ions into the body particularly cobalt and chromium since most metal on metal bearings are made of a cobalt chromium alloy. The long-term consequences of increased levels of these ions in the body are not known. High concentrations of Co and Cr are toxic and are known to interfere with a number of biological functions. There also have been recent reports of soft tissue reactions with MOM hip replacement. In the light of these concerns, it is important to examine factors which may influence the release of metal ions after MOM hip replacement. It has been reported in the recent literature that the position of the acetabular component will influence the bearing wear inturn leading to the release of metal ions after MOM hip replacement. Our findings indicate that steeply inclined acetabular components with an inclination angle greater than 50 degrees gives rise to higher concentration of metal ions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 557 - 557
1 Sep 2012
Roberts D Garlick N
Full Access

Introduction. Dislocation following total hip arthroplasty THA is a major short term complication not infrequently resulting in revision arthroplasty. Malposition of the acetabular component in THA results in a higher rate of dislocation as well as increased wear and osteolysis. The aim of this study was to assess the effect of mode of fixation on positioning of the acetabular component. Patients, materials and methods. For all THAs performed at our hospital in 2008, angle of acetabular inclination was measured using PACS by two independent observers. Interobserver and intraobserver reliability were assessed (Pearson's correlation coefficient, r). We determined whether the number of acetabular components outside the target angle range (eg:45±5°) was significantly different between cemented and cementless THA (chi squared test). An enquiry was made to the National Joint Registry (NJR) in respect to incidence of revision for dislocation of THA using cemented and cementless acetabular components, 2004–2009. Results. During 2008 126 THA were performed, 80 cemented and 46 cementless. There was good reliability of angle measurement (interobserver: r=0.89; intraobserver: r=0.87 and 0.97). More cemented acetabular components were within target angle range compared to cementless (cemented 32/80, cementless 29/46; chi squared=6.39, p<0.05). Using data from NJR comparing the number of primary hip replacement operations with number of revisions due to dislocation found a higher rate for cementless THA, 0.381% (266/69,822) than for cemented, 0.282% (262/92,928) (Odds ratio: 1.35 (95% CI 1.14–1.60; P<0.05). Conclusion. Positioning of the acetabular component is more difficult when using cementless systems as implant position is determined by orientation of reaming whereas with cement there is potential for fine implant position adjustment on insertion. The choice of a cementless acetabular component significantly increases the incidence of dislocation post THA. Acetabular component malposition is likely to be a factor in this increased incidence


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 705 - 710
1 May 2015
Ozmeric A Yucens M Gultaç E Açar HI Aydogan NH Gül D Alemdaroglu KB

We hypothesised that the anterior and posterior walls of the body of the first sacral vertebra could be visualised with two different angles of inlet view, owing to the conical shape of the sacrum. Six dry male cadavers with complete pelvic rings and eight dry sacrums with K-wires were used to study the effect of canting (angling the C-arm) the fluoroscope towards the head in 5° increments from 10° to 55°. Fluoroscopic images were taken in each position. Anterior and posterior angles of inclination were measured between the upper sacrum and the vertical line on the lateral view. Three authors separately selected the clearest image for overlapping anterior cortices and the upper sacral canal in the cadaveric models. The dry bone and K-wire models were scored by the authors, being sure to check whether the K-wire was in or out. In the dry bone models the mean score of the relevant inlet position of the anterior or posterior inclination was 8.875 (standard deviation (. sd. ) 0.35), compared with the inlet position of the opposite inclination of –5.75 (. sd. 4.59). We found that two different inlet views should be used separately to evaluate the borders of the body of the sacrum using anterior and posterior inclination angles of the sacrum, during placement of iliosacral screws. Cite this article: Bone Joint J 2015;97-B:705–10


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 243 - 243
1 Sep 2012
Bragdon C Malchau H Greene M Doerner M Emerson R Gebuhr P Huddleston J Cimbrelo E
Full Access

Introduction. Proper cup positioning is a critical component in the success of total hip arthroplasty surgery. A multicenter study has been initiated to study a new type of highly cross-linked polyethylene. This study provides a unique opportunity to a review the acetabular cup placement of over 500 patients implanted in the past 2 years from 13 medical centers from the U.S., Mexico, and Europe. Methods. 482 patients have received primary total hip arthroplasty using components from a single manufacturer in 5 centers in the US and Mexico and 7 centers in Europe. The acetabular anteversion and inclination were measured in post-operative radiographs. An acceptable window of cup position is defined at 5–25° of anteversion and 30–45° of inclination. Results. The measured cup anteversion and inclination averaged 15.89° ± 8.91° (0.00–42.25°) and 43.27° ± 7.17° (23.46–67.79°), respectively. Of the patient radiographs read, 71% were within the acceptable range of anteversion, 55% were in the acceptable range of inclination, and 41% satisfied both criteria. The best performing center had 86% of patients within the acceptable range of anteversion, 63% in the acceptable range of inclination, and 57% satisfied both criteria. The worst performing center had 54% within the acceptable range of anteversion, 29% in the acceptable range of inclination, and 17% satisfied both criteria. Conclusion. A significant variation in acetabular cup anteversion and inclination exists in this study both within and between the participating high volume centers. Correlation to mid- and long-term clinical outcome will show the clinical relevance of the finding, but liner designs with unsupported polyethylene should be used with caution


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 568 - 568
1 Sep 2012
Hussain A Kamali A Li C Ashton R
Full Access

INTRODUCTION. Whilst there is a great deal of research on hip implants, few studies have looked at implant orientation and the subsequent effect upon the wear performance of a hip resurfacing. This study aimed to measure implantation angles through radiographic analysis and linear wear for retrieved acetabular cups in order to investigate possible causal links between wear and implant orientation. MATERIALS & METHODS. Seventy Birmingham Hip Resurfacing (Smith & Nephew, UK) cups with known time in vivo were analysed. Linear wear of retrieved cups were assessed using a Talyrond 290 roundness machine. Deviations from the characteristic manufactured profile, was identified as a region of wear. Polar measurements across the wear region were taken to determine wear. The linear wear rate (LWR) of a component was defined as the linear wear (μm) divided by the duration of the implant life in vivo (years). Cups which showed the wear crossing over the edge of the cup were classified as edge loaded (EL). For all non-edge loaded (NEL) cups, the wear area was within the bearing surface. Cup orientation angles were conducted for 31 cups. This was determined by superimposing BHR models of appropriate size, generated by CAD ProEngineer Wildfire 4, onto anterior-posterior x-rays. Anatomical landmarks and specific features of the BHR were used as points of reference to determine cup version and inclination angles. RESULTS. Forty two cups were classed as EL, showing regions of wear extending beyond the edge of the cup. Twenty eight were classed as NEL. The EL group had an average LWR of 25.4(±8.05 95% CL) μm/yr, whilst the NEL group generated an average LWR of 1.45 (±0.34 95% CL) μm/yr, a statistically significant difference (p<0.05).a Following radiographic analysis, 23 cups were classed as EL, showing regions of wear extending beyond the edge of the cup. Eight were classed as NEL. Cups in the EL group showed average inclination and version angles of 54.35° (±5.37° 95% CL) and 22.43° (±5.23° 95% CL). Average inclination and version angles of cups in the NEL group were 45° (±7.20° 95% CL), and 14.88° (±3.38° 95% CL) respectively. Inclination and version angles between the two groups were statistically significant (p<0.05). DISCUSSION. Through linear wear and radiographic analysis, the current study has shown that mal-positioned resurfacing devices classed as EL had higher linear wear than the NEL cups. Edge loaded cups examined in this study showed significantly higher inclination and anteversion (p<0.05) than the non-edge loaded devices. This indicates that component wear is closely associated with in vivo orientation. The success of any implant is dependent upon implant orientation both in version and inclination angles. The correct implant orientation will help to ensure that wear occurs within the bearing surfaces, maintaining an optimal lubrication regime and low wear


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 94 - 94
1 Sep 2012
Penny J Varmarken J Ovesen O Nielsen C Overgaard S
Full Access

Introduction. Metal on metal articulations produce chromium (Cr) and cobalt (Co) debris, particularly when the articulations are worn in. High levels in the peripheral blood are indicative of excess wear and may cause adverse effects. The present RCT investigates metal ion levels and the relationship of Co, Cr ions and lymphocyte counts during the running-in period. Materials and Methods. Following randomization to RHA (ASRTM, DePuy) or THA we obtained whole blood (wb), and serum (s) samples at baseline, 8 w, 6 m and 1 y. We measured the Co and Cr concentrations, the total lymphocyte count as well as the CD3+, CD4+, CD8+, CD19+ and CD16+/CD56+ sub populations. Cup inclination and anteversion angles came from conventional radiographs. Activity was measured as steps by pedometer and UCLA activity. Data are presented as median (range). Results. We had 19 patients in each group. Age 57 (46–64) y (RHA) and 55 (44–64) y (THA). RHA only: head size: 51 (47 to 57)mm, cup inclination: 45.0 (40- 56)° and anteversion: 23 (7–38)°. The ion concentrations stayed below 0.2 ppb for THAs. For RHAs the Co and Cr concentrations generally rose markedly in the initial 8 weeks, followed by a slower ascent up to 1 year to wb Co: 1.0 (0.6–5.2), s Co: 1.3 (0.7–6.5), wb Cr: 1.3 (0.4–8.0) and s Cr: 1.7 (0.6–15) ppb. A high ion level was correlated to a small head size (p<0.03) and a cup inclination around 45° (p<0.04). We could not correlate the ion concentrations to the anteversion or the activity levels. The absolute lymphocyte counts were not always identical in the groups (eg. lower CD8+ for RHA) but there was no group difference when we analysed the change from baseline. We did not demonstrate any correlation between metal ion levels and lymphocyte subpopulations. Discussion. The findings of this study does not support the theory that metal ions suppress the lymphocytes or the CD8+ in particular (Hart et al., 2009). Our conclusions are limited by low numbers, but we suspect the theory could be biased by missing baseline values. Our study did not demonstrate the same 6–9 months ion peak found in other running-in studies (Back et al., 2005, Heisel et al., 2008), but rather a slow continuous rise with lower median ion concentrations. It could indicate lower wear or perhaps a longer running in period in our slightly older population. Contrary to our expectations we found that cups placed in optimal inclination displayed a higher ion level. Most of the smallest cups were found in this group, and the majority of the steep cups had very large heads. For this implant head size may be more important than cup position


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 539 - 539
1 Sep 2012
Bragdon C Doerner M Callanan M Zurakowski D Kwon Y Rubash H Malchau H
Full Access

Introduction. Acetabular cup positioning has been linked to dislocation and increased bearing surface wear. A previous study found correlations between patient and surgical factors and acetabular component position. The purpose of this study was to determine if acetabular cup positioning improves when surgeons receive feedback on their performance. Methods. Post-op anteroposterior (AP) pelvis and cross-table lateral radiographs were previously obtained for 2061 patients who received a total hip arthroplasty (THA) or hip resurfacing from 2004–2008. The surgeries were performed by 7 surgeons. AP radiographs were measured using Hip Analysis Suite to calculate the cup inclination and version angles. Acceptable ranges were defined for abduction (30–45 °) and version (5–25 °). The same surgeons performed a THA or hip resurfacing on 385 patients from January 2009 through June 2010. Cup inclination and version angles for this set of surgeries were compared to surgeries from 2004–2008 to determine if cup inclination and version angles improved in response to previous acetabular cup positioning studies. Improvement in accuracy was assessed by the chi-square test. Results. Time 1, from 2004 through 2008, had 1952 qualifying hips with 1845 having both version and abduction, and Time 2, from 2009 through June 2010, had 385 qualifying hips, all of which had both version and abduction angles. For Time 1, 1192 (62%) acetabular cups were within the abduction range, 1422 (79%) were within the version range, and 908 (49%) were within the range for both. For Time 2, 276 (72%) acetabular cups were within the abduction range, 250 (65%) were within the version range, and 217 (56%) were within the ranges for both. Accuracy of abduction angle improved (p<0.01) while accuracy of version angle decreased (p<0.01). Accuracy of acetabular cup positioning being within range for both abduction angle and version angle improved significantly (p=0.01), by 7%. Conclusions. Increased awareness and feedback on the resulting abduction and version measurements from THA surgery over time improves the positioning of the acetabular component. A system where objective measurements are presented to the surgeon can significantly improve cup placement which could improve the clinical outcome of THR patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 109 - 109
1 Sep 2012
Corten K Walscharts S Sloten JV Bartels W Simon J
Full Access

Introduction. It was the purpose to evaluate the biomechanical changes that occur after optimal and non-optimal component placement of a hip resurfacing (SRA) by using a subject specific musculoskeletal model based on CT-scan data. Materials and Methods. Nineteen hips from 11 cadavers were resurfaced with a BHR using a femoral navigation system. CT images were acquired before and after surgery. Grey-value segmentation in Mimics produced contours representing the bone geometry and identifying the outlines of the 3 parts of the gluteus medius. The anatomical changes induced by the procedure were characterised by the translation of the hip joint center (HJCR) with respect to the pelvic and femoral bone. The contact forces during normal gait with ‘optimal’ component placement were calculated for a cement mantle of 3 mm, a socket inclination of 45° and anteversion of 15°. The biomechanical effect of ‘non-optimal placement’ was simulated by varying the positioning of the components. Results. There was a significant (p<0.01) shortening of the muscle length with the ‘optimal’ component placement for all parts of the gluteus medius with the largest shortening of the posterior part by 6mm. This was caused by a significant shortening of the femoral offset by 2.3mm (p<0.01). Because of a significant (p<0.01) medialisation of the HJCR by 4 mm, there was no significant increase in contact force. The hip joint contact forces increased by 0.5% per mm HJCR displacement. Each millimeter of cranial and lateral displacement of the femoral HJCR increased the contact force by 0.5% and 1%, respectively. The contact stresses changed significantly by 0.8% and 0.2% per degree of socket inclination and anteversion. The contact force increased 1% per mm lateral displacement of the acetabular HJCR. Discussion. Optimal placement of the SRA components did not completely restore the biomechanics of the native hip joint. The contact forces were not increased due to the compensatory effect of the medialisation of the acetabular HJCR. This suggests that reaming to the acetabular floor should be conducted in SRA. Femoral component displacement in the cranial and lateral direction significantly increased the hip joint loading. Errors of socket placement in the coronal and sagital plane significantly increased the contact stresses. Accumulative errors of both component displacements could lead to increased contact stresses of 18% to 23% with socket inclinations of 50° and 55°. Surgeons should reconsider continuing the SRA procedure if a neck length loss and lateralisation of the HCJR by >5 mm is anticipated as this would increase the contact stresses by >12%


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 107 - 107
1 Sep 2012
Hadley M Hadfield F Hardaker C Isaac G Fisher J Wye J Barnett J
Full Access

Introduction. Hip wear simulation is a widely used technique for the pre-clinical evaluation of new bearing designs. However, wear rates seen in vitro can often be significantly different to those seen clinically. This can be attributed to the difference between the optimal conditions in a simulator and wide ranging conditions in real patients. This study aimed to develop more clinically relevant simulator tests, looking specifically at the effects of cup inclination angle (in vivo) and stop-dwell-start (SDS) protocols on a clinically available product. Method. Five tests using a Paul type walking cycle (ISO 14242) were carried out on two ProSim hip simulators: . 28mm MoM, standard walking, cup inclination 45°, (n = 5). 36mm MoM, standard walking, cup 45°, (n = 4). 36mm MOM, SDS: 10 walking cycles and pause of 5s with stance load of 1250N cup 45°, (n = 5). 36mm MOM, SDS: 10 walking cycles and pause of 30s with stance load of 1250N, (n = 5) cup 45°. 36mm MOM, standard walking, cup 55°(n = 5), and 65°(n = 5). All samples had matched clearances, measured using a CMM (Prismo Navigator, Zeiss, Germany). Wear was measured gravimetrically (Sartorius ME235S: 0.01mg). Results and Discussion. Metal-on-metal hip bearings are known to exhibit a bi-phasic wear pattern in-vitro (1), with the majority of wear occurring over the first 1–1.5mc, followed by lower steady state wear as the components conform to each other. Therefore bedding in wear over the first 1 million cycles was compared for each of the sample groups in this study. Bedding in wear for 36mm bearings under standard angle (45 inclination) and walking conditions was 0.16±0.15mm3/mc, while for 28mm bearings, wear was 2.67±2.06mm3/mc. Positioning the acetabular cup at an increased angle led to increased wear. At 55bedding in wear was .25±0.29mm3/mc, while at 65wear was 0.65±0.32mm3/mc. When SDS conditions were applied, no significant increase in wear was observed under either the 5s or 30s pause conditions, with bedding in wear of 0.19±0.31mm3/mc and 0.14±0.13mm3/mc respectively. Conclusion. This study illustrates the robust performance of the 36mm MoM bearing under extreme test conditions when compared with 28mm MoM. No effect was observed with the application of stop-dwell-start conditions, and only a small increase in wear was observed when the cup was inclined to a greater angle. Despite the application of extreme test conditions, the 36mm MoM still demonstrates lower wear than 28mm under all conditions. In all but the 65 inclination conditions, this difference is statistically significant. This study replicates some of the more frequently observed extreme conditions measured in real patients with THRs (2,3). Even under these more aggressive scenarios, wear of the 36mm bearing is still relatively low when compared with a commercially available 28mm THR


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 247 - 255
1 Feb 2021
Hassellund SS Williksen JH Laane MM Pripp A Rosales CP Karlsen Ø Madsen JE Frihagen F

Aims

To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years.

Methods

A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced AO/OTA A and C fractures were eligible if one of the following were found after initial closed reduction: 1) dorsal angulation > 10°; 2) ulnar variance > 3 mm; or 3) intra-articular step-off > 2 mm. Primary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) after 12 months. Secondary outcome measures were the Patient-Rated Wrist and Hand Evaluation (PRWHE), EuroQol-5 dimensions 5-level questionnaire (EQ-5D-5L), range of motion (ROM), grip strength, “satisfaction with wrist function” (score 0 to 10), and complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 837 - 840
1 Jun 2005
Azzopardi T Ehrendorfer S Coulton T Abela M

We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular fractures of the distal radius to compare the outcome of immobilisation in a cast alone with that using supplementary, percutaneous pinning. Patients treated by percutaneous wires had a statistically significant improvement in dorsal angulation (mean 7°), radial length (mean 3 mm) and radial inclination (mean 3 mm) at one year. However, there was no significant difference in functional outcome in terms of pain, range of movement, grip strength, activities of daily living and the SF-36 score except for an improved range of movement in ulnar deviation in the percutaneous wire group. One patient developed a pin-track infection which required removal of the wires at two weeks. We conclude that percutaneous pinning of unstable, extra-articular fractures of the distal radius provides only a marginal improvement in the radiological parameters compared with immobilisation in a cast alone. This does not correlate with an improved functional outcome in a low-demand, elderly population


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction. Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF. Objectives. To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA). Material and Methods. We performed a comparative retrospective study between two series of patients treated by fixed volar angle locking plate (40 patients) or volar buttress plate (36 patients). Distal radius fractures were classified by the AO/ASIF Müller classification after X-ray study in two views (Anteroposterios and lateral views), surgical treatment was indicated by the type of fracture (unstable fractures) and open fractures. Demographic information was gathered, injury mechanism and postoperatory complications. The minimal follow-up was 10 months. We performed clinical and radiographic evaluations before surgery, postoperatory, to 3 months and at the end of the follow-up (Palmar tilt, radial inclination, radial height and the radioulnar index were measured). Lidström's and Quick Dash scale, by means of telephonic survey, were used for the functional evaluation. Results. The time from fracture to surgery was on average 3.74 days in the group of DVR ® plates and 1.69 days for the group treated with T buttress plates. Henry's approach was realized in every case and the average time spent in surgery was 74 minutes for patients treated with T buttress plate and 80 minutes for patients treated with plate DVR®. In some cases K wires had to be used in 9 cases in the DVR® group and 7 in the other group. DVR® group obtained better results in radiological evaluation except in the radial inclination. In the Quick Dash scale, conducted a telephone survey, the average for the DVR® group was 26.40 (CI: 13.6 to 81.8) and 33.37 (CI: 10.2–90) for the group of T buttress plate (p=0.055). Conclusion. The potential advantages of ORIF in the distal radius fractures are low complication rate, stable subchondral fixation and early active movement of the wrist in the postoperative period. The disadvantages are a high cost, greater complexity and surgical exposure. Locking plates were designed to prevent postoperative collapse of the fracture also allows a better fix system in osteoporotic bone. Both types of plates obtained good results radiological and functional at the end of follow-up but we have obtained better results in the patients treated with locking plates


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 584 - 584
1 Sep 2012
Grammatopoulos G Thomas G Pandit H Glyn-Jones S Gill H Beard D Murray D
Full Access

INTRODUCTION. The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome. METHODS. In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version. The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome. RESULTS. There were 21 dislocations (3.1%) and 8 (1.2%) patients required revision at a mean follow up of 7 years. Experienced surgeons (2=0.047) and those operating with the patient in the lateral decubitus position (p=0.04) were more likely to achieve a cup orientation within any of the tested zones. Surgical approach (2=0.14) and patient's BMI (2=0.93) had no influence on whether a cup was within or outside any zone. There was no difference in dislocation rate between the posterior and anterio-lateral approaches (2=0.88). None of the zones tested had a significantly reduced dislocation risk (2=0.13), nor revision risk (2=0.55). OHS was not different for patients with cups within or outside any of the zones tested (p=0.523). DISCUSSION. There was a wide variation in cup orientation. Despite the wide scatter in cup orientation, no safe zone could be identified that would reduce dislocation and revision rate, nor improve patient reported outcome (OHS). Hence, these data suggest that acetabular component orientation should not be considered predictive of patients' early/mid-term complication/revision rate and outcome following THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 87 - 87
1 Apr 2013
Yamazaki H Kitahara J Kodaira H Seino S Akaoka Y
Full Access

Background. The usefulness of arthroscopic reduction for the intra-articular fracture of the distal radius has been reported, although it is technically difficult. Hypothesis. Our hypothesis is that the reduction using the external fixator is useful as equivalent to the arthroscopic reduction for the intra-articular fracture of the distal radius fracture in the fixation with the volar locking plate. Materials & Methods. The surgery was performed in both methods randomly for 40 patients; average age 64(24 to 92) years, 11 male, 29 female. Image evaluations were performed at 24 weeks after surgery. Ulnar variance, Radial inclination, Volar tilt in the X-ray image, and gap and step in the computed tomogram were evaluated. Clinical evaluation was performed at 6, 12, 24 weeks after surgery. Objective evaluations were ranges of motion and grip strength. Subjective evaluations were disabilities of the arm, shoulder, and hand (DASH). Results. The results of image and objective evaluation had no significant difference between the two groups. DASH in arthroscopic group was significantly inferior at 24 weeks because of minor complications. Discussion & Conclusion. The external fixator and the arthroscopy are equally valuable in reduction of articular surface


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 155 - 161
1 Feb 2020
McMahon SE Diamond OJ Cusick LA

Aims

Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort.

Methods

We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 236 - 236
1 Sep 2012
Queiroz M Barros F Daniachi D Polesello G Guimarães R Ricioli W Ono N Honda E
Full Access

Introduction. One of the most common complications of ceramic on ceramic hip replacement is squeaking. The association of Accolade stem and Trident acetabular system has been reported to have squeaking incidence of up to 35,6%. There is doubt if this phenomenon occurs due to: the stem titanium alloy, the V40 femoral neck, the recessed liner of the trident cup or even the mal-seating of the trident insert on the cup. Objectives. Primary: The purpose of the present study was to determine the incidence of squeaking in association with the use of Exeter stem and Trident ceramic acetabular system. Secondary: Analysis of the correlation of the cup abduction angle and squeaking. Methods. During the period from March 2004 to December 2008, two surgeons performed 87 total hip arthroplasties in 77 patients with use of a ceramic-on-ceramic bearing (Exeter stem, alumina head, Trident ceramic acetabular system). Seventy six patients (86 THA) were available for review after at least 18 months follow-up. The incidence of squeaking and other noises was analyzed. Cup abduction angle was measured. The Pearson correlation coefficient was used to determine if a correlation existed between the cup abduction angle and squeaking. Results. The incidence of squeaking was 2,63% (2 patients). Both patients reported a “click” noise in hyperextension of the hip. The mean abduction angle was 44 degress (35–60), and 48 degrees (46 and 50) on the squeaking group. There was no statistically significant difference in the in the mean cup inclination between squeaky and quiet hips. Conclusion. The incidence of squeaking in association with the use of Exeter stem and Trident ceramic acetabular system was 2,63%. There was no correlation of the cup abduction angle and squeaking


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 77 - 77
1 Sep 2012
Kappe T Fraitzl C Reichel H
Full Access

Background. Femoroacetabular impingement due to a reduced femoral head-neck-offset or excessive acetabular coverage will lead to early cartilage lesions of the hip joint. The purpose of the present study was to analyze the relationship between the extent of bony deformity and the presence and extent of cartilage lesions in femoroacetabular impingement. Methods. On the radiographs of 92 hip joints in 86 patients with a mean age of 36.5 ± 9.2 years who were operated on for with femoroacetabular impingement by surgical hip dislocation, the acetabular index of the weight-bearing zone, the center-edge-angle, the inclination of the acetabulum, the lateral-head-extrusion-index, retroversion signs of the acetabulum, the neck-shaft-angle, asphericity, superior and anterior alpha angles, and superior and anterior offset and offset ratios were assessed and correlated to the presence and extent of chondromalazia. Results. Acetabular chondromalazia was found in 60 hip joints. Full-thickness delamination of the acetabular cartilage was present in 42 of these hips with an average size of 1.1 ± 0.5 cm2. Femoral-sided chondromalazia was found in 9 hip joints. Hip joints with chondromalazia had a lower center-edge-angle (p = 0.014) and anterior offset ratio (p = 0.028) and a higher lateral-head-extrusion-index (p = 0.029). Hip joints with acetabular cartilage delamination had a significantly lower center-edge-angle (p = 0.012) and anterior offset (p = 0.03) and a significantly higher lateral-head-extrusion-index (p = 0.001) and superior (p = 0.006) and anterior alpha angles (p = 0.003). Conclusions. Marked cam-type femoral deformity and lesser coverage of the femoral head are associated with the acetabular cartilage lesions, arousing suspicion to the assumption that a large lateral aperture of the acetabulum abets proximal femora with cam-type deformity to inflict cartilage damage in femoroacetabular impingement


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 411 - 411
1 Sep 2012
Arumugam G Wraighte P Howard P Nanjayan S
Full Access

Introduction. Acetabular bone deficiency presents one of the most challenging problems during revision hip arthroplasty. A variety of surgical options and techniques are available including impaction bone grafting. We present our medium to long-term experience of 68 consecutive hips in 64 patients who had acetabular revision using impacted cancellous bone grafting with bone cement with a mean follow up of 10.5 ±3.75) years (range 5.1 to 17.7 years). Methods. Patients' undergoing acetabular bone grafting during revision hip arthroplasty prior to insertion of a cemented cup between 1993 and 2000 were evaluated. Pre-operative, immediate post-operative, 1 year post-op and final follow-up radiographs were evaluated. The pre-operative bone loss was graded according to the AAOS and Paprosky classifications. The presence of radiolucencies, alignment and incorporation of bone graft were evaluated. The Harris Hip Score (HHS) was used to assess clinical outcome. 13 patients who were unable to attend the department were contacted for a telephone interview. Analysis of the Data was carried out using SPSS17 [SPSS Inc. Chicago, Illinois]. Results. 64 consecutive patients (68 hips) were evaluated with an average age of 69.9 (± 10.24) years. At the mean follow up of 10.5 years [5.1–17.7 years] Kaplan-Meier survivorship analysis predicted a rate of survival of the acetabular component of 95.5% (95% confidence interval (CI) 92 to 99) at 10 years, with revision for any reason as the endpoint. The median Harris hip score at final follow up was 79.5 [IQR 67.9–80.45]. Neither the extent of initial defect or acetabular inclination were related to clinical outcome or predicted further revision. Progression of the radiololucent zones between the cement bone interface was a predictor of loosening and further revision. Discussion. Our findings have shown that acetabular revision using impacted cancellous bone graft and a cemented acetabular component remains a reliable and successful technique for patients with poor femoral bone stock