Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 86 - 86
1 Mar 2021
Hope N Arif T Stagl A Fawzy E
Full Access

Distal radius fractures (DRF) are very common injuries. National recommendations (British Orthopaedic Association, National Institute for Health and Care Excellence (NICE)) exist in the UK to guide the management of these injuries. These guidelines provide recommendations about several aspects of care including which type of injuries to treat non-operatively and surgically, timing of surgery and routine follow-up. In particular, current recommendations include considering immobilizing patients for 4 weeks in plaster for those managed conservatively, and operating on fractures within 72 hours for intra-articular injuries and 7 days for extra-articular fractures. With increased demands for services and an ageing population, prompt surgery for those presenting with distal radius fractures is not always possible. A key factor is the need for prompt surgery for hip fracture patients. This study is an audit of the current standard of care at a busy level 2 trauma unit against national guidelines for the management of DRFs. This retrospective audit includes all patients presenting to our emergency department from June to September 2018. Patients over 18 years of age with a diagnosis of a closed distal radius fracture and follow-up in our department were included in the study. Those with open fractures were excluded. Data was retrieved from clinical coding, electronic patient records, and IMPAX Client (Picture archiving and communication system). The following data was collected on patients treated conservatively and those managed surgically:- (1)Time to surgery for surgical management; (2)Period of immobilization for both conservative and operative groups. 45 patients (13 male, 32 female) with 49 distal radius fractures (2 patients had bilateral injuries) were included. Patients had mean age 63 years (range 19 to 92 years) 30 wrists were treated non-operatively and 19 wrists treated surgically (8 K-wires, 10 ORIF, 1 MUA). Mean time to surgery in the operative group was 8 days (range 1 – 21 days, median 7 days). Mean time to surgery for intra-articular fractures was 7 days (range 1 – 21) and 12 days for extra-articular fractures (range 4 – 20). Mean immobilization period in those treated in plaster is 6 weeks (range 4 – 13 weeks, median 5.6 weeks). At busy level 2 trauma units with limited theatre capacity and a high volume of hip fracture admissions, time to surgery for less urgent injuries such as wrist fractures is often delayed. National guidelines are useful in helping to guide management however their standards are often difficult to achieve in the context of increasing populations in urban areas and an ageing population


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 12 - 12
1 Nov 2018
Grassi M Grimm B Nuritdinow T Lederer C Daumer M Hellsten Y
Full Access

Lower limb fractures are commonly treated with cast immobilization, and as a main consequence of strict immobilization this typically leads to loss in muscle mass, decrease of bone density and decline in functional abilities. Body-worn sensors are increasingly used to assess outcome in clinical trials by providing objective mobility parameters in a real-world environment. The aim of this study is to investigate the usability aspects and potential changes in mobility parameters in partial-immobilization patients in real-world conditions. Six healthy young males (age 22.2 ± 1.2 years; weight 76.5 ± 6.7 kg, height 185.8 ± 6.1 cm. Mean ± standard deviation) wore a leg cylinder cast with walker boot to immobilize their dominant leg for two consecutive weeks. Subjects were asked to continuously wear a tri-axial accelerometer on the waist (actibelt) during waking hours for 6 weeks including 2 weeks before, during and after cast immobilisation. The total amount of days of continuous recording was 339 days with a total wearing time of 120 days. Software packages which allow to detect steps and to estimate real-world walking speed were used to analyse the accelerometry data. It was suspected that knee immobilization would affect strongly the wave form of the signal with an impact on the accuracy of the speed algorithm, whereas the step detection should be more robust. This effect was confirmed in a preliminary study performed to quantify the accuracy under immobilization conditions. On the other hand, step numbers are known to be sensitive to fluctuations in wearing time which was not uniform throughout the entire study. We concluded that in this setting step frequency is the most reliable parameter. Step frequency showed a systematic decrease in the values during the immobilization period which recovered to pre-immobilisation values after cast removal. This confirms the usability of accelerometry and sensitivity of its mobility parameters for clinical outcome assessment


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 50 - 50
4 Apr 2023
Wang Z van den Beucken J van den Geest I Leeuwenburgh S
Full Access

Residual tumor cells left in the bone defect after malignant bone tumor resection can result in local tumor recurrence and high mortality. Therefore, ideal bone filling materials should not only aid bone reconstruction or regeneration, but also exert local chemotherapeutic efficacy. However, common bone substitutes used in clinics are barely studied in research for local delivery of chemotherapeutic drugs. Here, we aimed to use facile manufacturing methods to render polymethylmethacrylate (PMMA) cement and ceramic granules suitable for local delivery of cisplatin to limit bone tumor recurrence. Porosity was introduced into PMMA cement by adding 1-4% carboxymethylcellulose (CMC) containing cisplatin, and chemotherapeutic activity was rendered to two types of granules via adsorption. Then, mechanical properties, porosity, morphology, drug release kinetics, ex vivo reconstructive properties of porous PMMA and in vitro anti-cancer efficacy against osteosarcoma cells were assessed. Morphologies, molecular structures, drug release profiles and in vitro cytostatic effects of two different drug-loaded granules on the proliferation of metastatic bone tumor cells were investigated. The mechanical strengths of PMMA-based cements were sufficient for tibia reconstruction at CMC contents lower than 4% (≤3%). The concentrations of released cisplatin (12.1% and 16.6% from PMMA with 3% and 4% CMC, respectively) were sufficient for killing of osteosarcoma cells, and the fraction of dead cells increased to 91.3% within 7 days. Functionalized xenogeneic granules released 29.5% of cisplatin, but synthetic CaP granules only released 1.4% of cisplatin over 28 days. The immobilized and released cisplatin retained its anti-cancer efficacy and showed dose-dependent cytostatic effects on the viability of metastatic bone tumor cells. Bone substitutes can be rendered therapeutically active for anticancer efficacy by functionalization with cisplatin. As such, our data suggest that multi-functional PMMA-based cements and cisplatin-loaded granules represent viable treatment options for filling bone defects after bone tumor resection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 44 - 44
4 Apr 2023
Knopp B Harris M
Full Access

Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement. Patients treated with closed reduction were reduced from a mean displacement of 29.26±36.18% at an angulation of 22.67±16.57 degrees to 7.88±9.07% displacement and 3.89±6.68 degrees angulation post-reduction. Patients developing complications including a loss of reduction or refracture were found to have post-operative radiographs with a lower percent displacement (0.50±1.12) than those not developing complications (8.65±9.21)(p=0.0580). Post-reduction angulation (p=1.000), average reduction in angulation (p=1.000) and average reduction in displacement percent(p=0.2102) were not significantly associated with development of complications. Percent displacement of radial shafts was seen to be the most important metric to monitor in post-operative radiographs for patients undergoing closed reduction of a forearm fracture. We theorize a slight displacement provides greater surface area for osteoblastic expansion and callus formation leading to a decreased risk of refracture or loss of reduction. While our sample size precludes our ability to measure the ideal amount of post-reduction displacement for optimal healing, our results demonstrate that some degree of shaft displacement is required for optimal healing conditions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 45 - 45
2 Jan 2024
Riool M Li R Hofwegen L de Boer L Loontjens J Zaat S
Full Access

Infection of implanted medical devices (biomaterials), like titanium orthopaedic implants, can have disastrous consequences, including removal of the device. These so-called biomaterial-associated infections (BAI) are mainly caused by Staphylococcus aureus and Staphylococcus epidermidis. To prevent biofilm formation using a non-antibiotic based strategy, we aimed to develop a novel permanently fixed antimicrobial coating for titanium devices based on stable immobilized quaternary ammonium compounds (QACs). Medical grade titanium implants were dip-coated in subsequent solutions of hyperbranched polymer, polyethyleneimine and 10 mM sodium iodide, and ethanol. The QAC-coating was characterized using water contact angle measurements, scanning electron microscopy, FTIR, AFM and XPS. The antimicrobial activity of the coating was evaluated against S. aureus strain JAR060131 and S. epidermidis strain ATCC 12228 using the JIS Z 2801:2000 surface microbicidal assay. Lastly, we assessed the in vivo antimicrobial activity in a mouse subcutaneous implant infection model with S. aureus administered locally on the QAC-coated implants prior to implantation to mimic contamination during surgery. Detailed material characterization of the titanium samples showed the presence of a homogenous and stable coating layer at the titanium surface. Moreover, the coating successfully killed S. aureus and S. epidermidis in vitro. The QAC-coating strongly reduced S. aureus colonization of the implant surface as well as of the surrounding tissue, with no apparent macroscopic signs of toxicity or inflammation in the peri-implant tissue at 1 and 4 days after implantation. An antimicrobial coating with stable quaternary ammonium compounds on titanium has been developed which holds promise to prevent BAI. Non-antibiotic-based antimicrobial coatings have great significance in guiding the design of novel antimicrobial coatings in the present, post-antibiotic era. Acknowledgements: This research was financially supported by the Health∼Holland/LSH-TKI call 2021–2022, project 25687, NACQAC: ‘Novel antimicrobial coatings with stable non-antibiotic Quaternary Ammonium Compounds and photosensitizer technology'


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 61 - 61
11 Apr 2023
Wendlandt R Herchenröder M Hinz N Freitag M Schulz A
Full Access

Vacuum orthoses are being applied in the care of patients with foot and lower leg conditions, as ankle fractures or sprains. The lower leg is protected and immobilized, which increases mobility. Due to the design, the orthoses lead to a difference in leg length, i.e. the side with the orthosis becomes longer, which changes the gait kinematics. To prevent or mitigate the unfavourable effects of altered gait kinematics, leg length-evening devices (shoe lifts) are offered that are worn under the shoe on the healthy side. Our aim was to evaluate the effect of such a device on the normality of gait kinematics. Gait analysis was conducted with 63 adult, healthy volunteers having signed an informed consent form that were asked to walk on a treadmill at a speed of 4.5km/h in three different conditions:. barefoot - as reference for establishing the normality score baseline. with a vacuum orthosis (VACOPed, OPED GmbH, Germany) and a sport shoe. with a vacuum orthosis and a shoe lift (EVENup, OPED GmbH, Germany). Data was sampled using the gait analysis system MCU 200 (LaiTronic GmbH, Austria). The positions of the joint markers were exported from the software and evaluated for the joint angles during the gait cycle using custom software (implemented in DIAdem 2017, National Instruments). A normality score using a modification of the Gait Profile Score (GPS) was calculated in every 1%-interval of the gait cycle and evaluated with a Wilcoxon signed rank test. The GPS value was reduced by 0.33° (0.66°) (median and IQR) while wearing the shoe lift. The effect was statistically significant, and very large (W = 1535.00, p < .001; r (rank biserial) = 0.52, 95% CI [0.29, 0.70]). The significant reduction of the GPS value indicates a more normal gait kinematics while using the leg length-evening device on the contralateral shoe. This rather simple and inexpensive device thus might improve patient comfort and balance while using the vacuum orthoses


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 65 - 65
4 Apr 2023
Mazetyte-Godiene A Vailionyte A Valiokas R Usas A
Full Access

Herein we address, hyaline cartilage regeneration issue by engineering a synthetic biocompatible hydrogel scaffold capable to promote chondrogenic differentiation. In this study, the chemically crosslinked hydrogels consisting of synthetic peptides that have the collagen-like sequence Cys-Gly-(Pro-Lys-Gly)4 (Pro-Hyp-Gly)4 (Asp-Hyp-Gly)4- conjugated with RGD sequence (CLP-RGD) and crosslinked hydrogels of type I collagen (CA) were used. For cartilage formation, we used human skeletal muscle-derived stem/progenitor cells (hMDSPCs) set for differentiation towards a chondrogenic lineage by BMP-7 and TGF-ß3 growth factors. Initially 150, 100 and 75 ng of BMP-7and TGF-ß3 growth factors were inserted in each scaffold and amount of growth factors diffusing out of the scaffolds was observed by ELISA assays. In vitro experiments were performed by seeding hMDSPCs onto hydrogels loaded with growth factors (75ng/scaffold) and cultured for 28 days. Cartilage formation was monitored by ELISA and RT-PCR assays. All experiments were performed in triplicates or quadruplicates. Growth factors incorporation strategy allowed a sustained release of TGF-ß3 growth factor, 6.00.3% of the initially loaded amount diffused out after 4 h and 2.70.5% already at the second time point (24h) from CA and CLP-RGD substrates. For the BMP-7 growth factor, 13.12.3% and 15.751.6% of the initially loaded amount diffused out after 4 h, 1.70.2% and 2.450.3% at the second time point (24 h) from CA and CLP-RGD respectively. In vitro experiments shown that scaffolds with immobilized growth factors resulted in higher collagen type II accumulation when compared to the scaffolds alone. The gene expression on CLP-RGD hydrogels with growth factors has shown lower collagen type I expression and higher aggrecan expression compared to day 0. However, we also report increased collagen X gene expression on CA hydrogels (with growth factors). Our results support the potential of the strategy of combining hydrogels functionalized with differentiation factors toward improving cartilage repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 125 - 125
4 Apr 2023
Heylen J Macdonald N Larsson E Moon K Vaughan A Owens R
Full Access

In current practice in the UK there are three main approaches to investigating suspected scaphoid fractures not seen on initial plain film x-rays. Early MRI of all cases. Review all cases in clinic at two weeks with repeat x-rays. Hybrid model. Virtual Fracture Clinic (VFC) triage to reduce those who are seen in clinic at two weeks by:. ∘. Organising early MRI for those with high-risk presentation. ∘. Discharging those with an alternative more likely diagnosis. Our unit uses the VFC model. We aimed to evaluate its efficiency, safety, clinical outcomes and economic viability. All patients attending the emergency department with either a confirmed or suspected scaphoid fracture between March and December 2020 were included (n=305). Of these 297 were referred to the VFC: 33 had a confirmed fracture on x-ray and 264 had a suspected fracture. Of the suspected fractures reviewed in VFC 14% had an MRI organised directly owing to a high-risk presentation, 79% were brought for fracture clinic review and 17% discharged with an alternative diagnosis such as osteoarthritis. Of those subsequently reviewed in fracture clinic at two weeks: 9% were treated as scaphoid fractures (based on clinical suspicion and repeat x-rays), 17% had MRI or CT imaging organised, 5% did not attend and 69% were discharged. Overall, 17% of cases initially triaged, had further imaging – 41 MRIs and 5 CTs. MRI detected: 5% scaphoid fracture, 17% other fracture, 24% bone contusion, complete ligament tear 10%, partial ligament tear 39% and normal study 10%. The results of MRI minimally affected management. 3 patients were taken out of plaster early, 1 patient was immobilized who was not previously and no patients underwent operative management. In the following 12-month period one patient re-presented with a hand or wrist issue. This approach avoided 218 MRIs, equating to £24000 and 109 hours of scanner time. VFC triage and selective use of MRI scanning is a safe, efficient and cost-effective method for the management suspected scaphoid fractures. This can be implemented in units without the resource to MRI all suspected scaphoid fractures from the emergency department


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 111 - 111
1 Nov 2018
Mogensen SL Rasmussen MK Le D Nielsen A Foldager CB
Full Access

Osteoarthritis (OA) is an inflammatory degenerative disease that affects every fourth person with irreversible damage to the articular. Mesenchymal stem cells (MSCs) have been shown to affect host cells by paracrine stimulation in regenerative environments. Here we apply hyaluronic acid (HA), an essential part of the extracellular matrix in cartilage, for MSC immobilization. The aim was to investigate long-term MSC survival and paracrine effect on chondrocytes in an inflammatory co-culture environment. We hypothesized that MSCs immobilized in a HA hydrogel could provide a long-term immunomodulatory effect on chondrocytes in vitro. Human MSCs were seeded in a HA hydrogel and co-cultured with non-osteoarthritic human chondrocytes in biphasic wells inhibiting cellular contact. An inflammatory environment was induced by IL1-beta and compared with standard culture medium. Relative gene expressions of collagen types I, II and X, aggrecan, SOX9, MMP-13 and ADAMTS-5) were examined at day 3,7,14 and 28. Significant up-regulation of SOX9 at day 7, 14 and 28 and a significant down-regulation of ADAMTS-5 (day 14 and 28) was observed with co-culture of HA-immobilized MSCs and MSCs compared with controls with or without HA (without MSCs)No changes in expression was observed for aggrecan and collagen type 1. We showed that MSC affect the expression of SOX9 and ADAMTS-5 in a paracrine manner when co-cultured with chondrocytes in an inflammatory environment. MSCs immobilized in HA hydrogels survived and were contained in the hydrogel for up to 28 days. This suggests that HA-immobilized MSCs could potentially be used as adjuvant treatment of OA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 276 - 276
1 Jul 2014
Nasto L Colangelo D Sernia C Di Meco E Fabbriciani C Fantoni M Pola E
Full Access

Summary. Pyogenic spondylodiscitis is an uncommon but severe spinal infection. In majority of cases treatment is based on intravenous antibiotics and rigid brace immobilization. Posterior percutaneous spinal instrumentation is a safe alternative procedure in relieving pain, preventing deformity and neurological compromise. Introduction. Pyogenic spondylodiscitis (PS) is an uncommon but severe spinal infection. Patients affected by a non-complicated PS and treatment is based on intravenous antibiotics and rigid brace immobilization with a thoracolumbosacral orthosis (TLSO) suffices in most cases in relieving pain, preventing deformity and neurological compromise. Since January 2010 we started offering patients percutaneous posterior screw-rod instrumentation as alternative approach to TLSO immobilization. The aim of this study was to evaluate safety and effectiveness of posterior percutaneous spinal instrumentation for single level lower thoracic (T9-T12) or lumbar pyogenic spondylodiscitis. Materials and Methods. Retrospective cohort analysis on 27 patients diagnosed with PS who were offered to choose between 24/7 TLSO rigid bracing for 3 to 4 months and posterior percutaneous screw-rod instrumentation bridging the infection level followed by soft bracing for 4 weeks after surgery. All patients underwent antibiotic therapy. Fifteen patients chose conservative treatment, 12 patients chose surgical treatment. Patients were seen at 1, 3, 6, 9 months after diagnosis. Erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) and complete blood count were measured at each follow-up visit. Segmental kyphosis was measured at diagnosis and at 9 months. VAS, SF-12, and EQ-5D questionnaires were recorded at each follow-up visit. Baseline groups’ demographic characteristics were assessed using independent sample t-tests for continuous variables and χ2 tests for frequency variables. Results. Complete healing was achieved in all patients, no difference was observed in healing time between the two groups (77.3±7.2 days vs 80.2±4.4). Instrumentation failure and screw loosening was not observed in any patient. In both group CRP and ESR decreased accordingly with response to antibiotic therapy. Surgically treated patients had significantly lower VAS scores at 1 month (3.05±0.57 in surgery group vs 5.20±1.21 in TLSO group) and 3 months (2.31±0.54 in surgery group vs 2.85±0.55 in TLSO group) post-diagnosis. Both groups had similar trends toward fast recovery in both mental (MCS) and physical components (PCS) of SF-12 questionnaire, surgically treated patients showed steeper and statistically significative improvement at 1 month (37.83±4.57 MCS in surgery group vs 24.52±3.03 MCS in TLSO group and 35.46±4.43 PCS in surgery group vs 27.07±4.45 PCS in TLSO group, p<0.001), 3 months (52.94±3.82 MCS in surgery group vs 39.45±4.92 MCS in TLSO group and 44.93±3.73 PCS in surgery group vs 35.33±6.44 PCS in TLSO group, p<0.001), and 6 months (54.93±3.56 MCS in surgery group vs 49.99±5.82 MCS in TLSO group) post-diagnosis, no statistically significant differences were detected at the other time points (9 months post-diagnosis). EQ-5D index was significantly higher in surgery patients at 1 month (0.764±0.043 in surgery group vs 0.458±0.197 in TLSO group) and 3 months (0.890±0.116 in surgery group vs 0.688±0.142 in TLSO group); no statistically significant changes were observed in segmental kyphosis between the two groups. Conclusion. Posterior percutaneous spinal instrumentation is a safe, feasible, and effective procedure in relieving pain, preventing deformity and neurological compromise. Surgical stabilization was associated with faster recovery, lower pain scores, and improved quality of life compared with TLSO conservative treatment at 1 and 3 months after diagnosis


Bone & Joint 360
Vol. 11, Issue 5 | Pages 46 - 47
1 Oct 2022
Das A


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 5 - 5
1 Nov 2018
Huegel J Boorman-Padgett J Nuss C Minnig M Tucker J Cirone J Morris T Choi D Kuntz A Waldorff E Zhang N Ryaby J Soslowsky L
Full Access

PEMF is currently approved by the FDA for adjunctive treatment of lumbar/cervical spine fusion and for treatment of long-bone non-unions. Soft tissues are a potential new therapeutic application for PEMF due to pre-clinical studies showing a reduction of inflammatory markers following PEMF exposure. The aim was therefore to investigate the structural/functional effects of PEMFs on tendon-to-bone and tendon-to-tendon healing in a rotator-cuff (RC) and Achilles tendon (AT) repair model, respectively. RC study: Adult male rats (n=280), underwent bi-lateral supraspinatus tendon transections with immediate repair followed by cage activity until sacrifice (4, 8, and 16 weeks). Non-controls received PEMF for 1, 3, or 6 hours daily. AT study: Male rats underwent acute, complete transection and repair of the Achilles tendon (FULL, n=144) or full thickness, partial width injury (PART, n=160) followed by immobilization for 1 week. Sacrifice was at 1, 3, and 6 weeks. Outcome measures included passive joint mechanics, gait analysis, biomechanical assessments, histological analysis of the repair site and mCT (humerus) assessment (FULL only). RC study: Significant increases in modulus, stiffness, bone mineral content and improved collagen organization was observed for the PEMF groups. No differences in joint mechanics and ambulation were observed. AT study: A decrease in stiffness and limb-loading rate was observed for the PEMF groups for the FULL groups, whereas an increase in stiffness with no change in range-of-motion was seen for the PART groups. The combined studies show that PEMF can be effective for soft tissue repair but is dependent on the location of application


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 1 - 1
1 Mar 2013
Nowlan NC Sharp J
Full Access

Developmental dysplasia of the hip (DDH) is the most common post-natal skeletal abnormality. It is widely acknowledged that conditions which cause or result in reduced movement in utero are contributing factors to the incidence of DDH. However, the hypothesis that prenatal movement plays a role in normal development of the hip joint has not been tested using embryonic model systems. This research investigates the effects of immobilization in chick embryos on hip joint morphogenesis. Embryonic chicks were treated in ovo using a neuromuscular blocking agent from embryonic days 5 to 9. Limbs were stained for cartilage using alcian blue, and were scanned in 3-D. Standardized virtual sections of the femur were taken and a number of virtual sections from age-matched limbs were overlaid in order to compare between control and immobilized limbs. The results show that not all immobilised limbs were equally affected, with some immobilised embryos having almost normal joint shapes, and other immobilised embryos displaying decreased protuberance of the femoral head and decreased indentation at the femoral neck. Our results demonstrate that the mechanobiological response to immobilisation can vary between individuals, but also that preventing movement during embryonic development can lead to abnormal morphogenesis of the developing proximal femur in some individuals, providing evidence that reduced movement during development can lead to features of DDH


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 316 - 316
1 Jul 2014
Hasegawa S Mizutani J Otsuka S Suzuki N Fukuoka M Otsuka T Banks S
Full Access

Summary. Bi-plane Image matching method is very useful technique to evaluate the loaded 3D motion of each cervical level. Introduction. Cervical orthoses are commonly used to regulate the motion of cervical spines for conservative treatment of injuries and for post-operative immobilization. Previous studies have reported the efficacy of orthoses for 2D flex-extension or 3D motions of the entire cervical spine. However, the ability of cervical orthoses to reduce motion might be different at each intervertebral level and for different types of motion (flexion-extension, rotation, lateral bending). The effectiveness of immobilizing orthoses at each cervical intervertebral level for 3D motions has not been reported. The purpose of this study is to evaluate the effectiveness of the Philadelphia collar to each level of cervical spines with 3D motion analysis under loading condition. Patients & Methods. Patient Sample: Four asymptomatic volunteer subjects were recruited and provided informed consent. Approval of the experimental design by the institutional review board was obtained. These 4 individuals were without any history of cervical diseases or procedures. The presence of any symptoms, spinal disorders and anatomical abnormalities in fluoroscopic images or CT was a criterion of exclusion from this study. Outcome Measures: To evaluate the efficacy of the Philadelphia collar, ANOVA was used to compare the range of motion with and without collar at the C3/4, C4/5, C5/6 and C6/7 intervertebral levels for each motion. The level of statistical significance was set at p<0.05. When a statistical difference was detected, post hoc Tukey tests were performed. Methods. Three-dimensional models of the C3-C7 vertebrae were developed from CT scans of each subject using commercial software. Two fluoroscopy systems were positioned to acquire orthogonal images of the cervical spine. The subject was seated within the view of the dual fluoroscopic imaging system. Pairs of images were taken in each of 7 positions: neutral posture, maximum flexion and extension, maximum left and right lateral bending, and maximum left and right rotation. The images and 3D vertebral models were imported into biplane 2D-3D registration software, where the vertebral models were projected onto the pair of digitised images and the 3D bone pose was adjusted to match its radiographic projection in each image. Relative motions between each vertebral body were calculated from body-fixed coordinate systems using a flexion-lateral bending-axial rotation Cardan angle sequence. Results. Flexion range was significantly reduced with the collar at each cervical level. Extension range was significantly reduced at the C3/4 level. Rotation and lateral bending were reduced for C3/4, C4/5, C5/6 levels with the collar. Discussion/Conclusion. The Philadelphia Collar significantly reduces cervical motion at C3/4, C4/5 and C5/6 levels in almost all motions (except for extension). At the C6/7 level, this type of collar has limited effectiveness reducing cervical motion. We used 3D radiographic measurements to quantify the effectiveness of the Philadelphia collar for reducing cervical motion. Bi-plane 2D-3D registration method is useful technique to evaluate 3D motion of cervical spines


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 15 - 15
1 Apr 2018
Neuerburg C Pfeufer D Lisitano LA Schray D Mehaffey S Böcker W Kammerlander C
Full Access

Abstract. In aged trauma patients the basic prerequisite is early mobilization and full weight-bearing, as immobilization can trigger various complications such as pressure ulcers, pneumonia, urinary tract infections and others. Mortality of elderly patients increases significantly in fracture patients with partial weight-bearing compared to populations with total weight-bearing. Besides the limited physical strength in these patients, partial-weight bearing is however frequently used for the aftercare of hip fracture patients. Therefore, the present study aims to evaluate mobility of aged hip fracture patients with regards to weight-bearing and postoperative mobility. Methods. An insole mobile force sensor was used to measure the post-operative weight-bearing by assessing the compressive forces between foot and shoe. Only patients (n=15) that suffered a trochanteric fracture >75 years of age were included and compared to a study group of patients (n=18) with fractures of the lower limb <40 years of age. Patients with cognitive disorders such as delirium and other diseases limiting the realization of partial weight-bearing were excluded. Both groups were instructed to maintain partial weight bearing of the affected limb following surgery. Following five days of training by our department of physiotherapy, the patients were requested to perform a gait analysis with the insole mobile force sensor. During gait analysis the maximum load was measured (kg) and the time over which the partial load could be maintained was determined. Results. None of the aged patients in the test group could meet the partial load at all times. 73.33% of patients (11 out of 15) exceeded the specified load by more than twice (> 40 kg). In the control group, 55.56% (10 of 18) of the patients were able to meet the partial load. A further 22.22% of the young patients (4 out of 18) were able to exceed only slightly (<120%, <24 kg). It was also shown that only 11.11% (2 of 18) put more than double of the allowed weight (> 40 kg) on the affected leg in the younger group. Only one of the aged patients was able to exceed the pre-determined weight-bearing restrictions for less than 10% of the measured time. In comparison, significantly more patients in the control group (88,89%; 16 of 18; p<0,05) were able to maintain the partial load for more than 90.0% of the time of gait analysis. Conclusion. Elderly patients seem to be unable to follow partial weight-bearing restrictions as proven in the present trial. As early mobilization of geriatric trauma patients is an important element for a successful rehabilitation, the relict of postoperative partial weight-bearing in these patients should be abandoned. Thus, the surgical therapy should allow immediate full weight bearing following surgery of aged hip fracture patients


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 230 - 230
1 Jul 2014
Nicolescu R Ouellette E Clifford P Kam C Sawardeker P Latta L
Full Access

Summary. Practitioners should maintain a high suspicion of concurrent carpal fractures in patients who present with a distal radius fracture after a fall onto an outstretched hand, particularly if forearm rotation is involved. Introduction. Simultaneous scaphoid and distal radius fractures, and the importance of their identification, have been previously described in multiple reports. However, few studies have investigated the incidence of carpal fractures, in general, occurring concurrently with distal radius fractures after a common mechanism of wrist injury. The purpose of this study is to investigate the incidence and characteristics of carpal fractures occurring simultaneously with distal radius fractures after a fall onto an outstretched hand. We hope to determine whether different fall parameters, such as hand position and forearm rotation, influence the frequency of this injury. Methods. Baseline MRI scans and fluoroscopic images of the wrist were obtained for two sets of 24 fresh frozen cadaveric arms. All of the arms were transected 18 cm proximal to Lister's tubercle and then mounted at 80° of wrist extension and full pronation. In the first set of 24 arms, eight were mounted perpendicular to the MTS table top, eight were radially deviated 10–15°, and eight were ulnarly deviated 10–15°. In the second set of 24 arms, twelve underwent 5 N-m of external forearm rotation, with six of the arms perpendicular to the MTS table top and the other six ulnarly deviated 10–15°. The last twelve arms underwent 5 N-m of internal forearm rotation, with six of the arms perpendicular to the MTS table top and the other six radially deviated 10–15°. The arms were then loaded on an MTS machine and axially displaced 2.5 cm at a compression rate of 5 cm/sec. Post injury fluoroscopic images and MRI scans of the wrist were obtained and analyzed. The MRI scans were scrutinised by one of us (EAO) – a board certified orthopaedic surgeon. Results. All of the arms sustained a distal radius fracture. Post-stress MRI revealed that 17 (35%) of the wrists also sustained at least one carpal bone fracture. The most common carpal bone injured was the scaphoid, which was fractured in 15 of the 17 arms with concurrent carpal fractures, or 31% of the arms overall. Moreover, lunate fractures were present in 6 of the wrists, triquetral fractures in 4 of the wrists, capitate fractures in 3 of the wrists, and one hamate fracture was present. Of the 17 arms with concurrent fractures, 15 had been subjected to a rotational force during MTS testing. Discussion. The incidence of carpal fractures occurring simultaneously with distal radius fractures after a fall onto an outstretched hand comprised a substantial proportion of the arms examined. While the type of carpal fracture does not appear to correlate with a specific hand position, it is evident that forearm rotation is more likely to result in concomitant injury. Early wrist motion—now the standard of care—after immobilization of a patient with a distal radius fracture may result in non-union if a missed carpal fracture is also present


Bone & Joint 360
Vol. 9, Issue 3 | Pages 44 - 45
1 Jun 2020
Das MA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 224 - 224
1 Jul 2014
Emohare O Christensen D Morgan R
Full Access

Summary Statement. Pedicle screws provide robust fixation and rigid immobilization. There has been no attempt to correlate the anatomic dimensions of thoracic and lumbar pedicles with the accuracy of navigated insertion. This study demonstrates that comparable accuracy using this technique. Introduction. Pedicle screws provide robust mechanical fixation, which makes their use attractive; their use enables fixation of the three spinal columns. There remains concern about the potential both for misplacement; various investigators have studied the accuracy of pedicle screw insertions, comparing different techniques. What is not clear, however, is whether there is any relation between the variables of pedicles’ anatomic dimensions, screw dimensions and accuracy. This study aims to elucidate the relationship between these variables. Patients & Methods. We conducted a retrospective review of consecutive pedicle screws that were inserted in the thoracic and lumbar spine at our institution. Screws were inserted using the navigated method (Stealth Station® TREON™, Medtronic, Louisville, CO). The accuracy of the screw insertion was measured using the classification system developed by Gertzbein and Robbins; pedicle dimensions were measured from post-operative computed tomography scans. The corresponding pre-operative scans were then used to measure the pedicle dimensions at the other levels. The magnitude of a cortical breach in the pedicle was represented by a letter: A (no breach), B (<2mm), C (>2mm, <4mm), D (>4mm, <6mm) and E (>6mm). In addition, measurements were made of the anatomic dimensions of the pedicles. The combination of these two measures allowed for direct correlation to be made between the accuracy of screw insertion, screw dimensions and pedicle anatomy. We then computed the proportion of each pedicle (width) occupied by a screw. Results. A total of 765 screws were reviewed, 493 were in the thoracic spine and 272 in the lumbar spine. Of the screws in the thoracic spine, 472 (96%) were either fully in the pedicle or less than 2mm beyond the cortex (within the A+B classification); when considered separately, 323 (66%) were completely within the pedicle (A) and 149 (30%) were less than 2mm beyond the cortex. A total of 21 (4%) screws were beyond 2mm but within 6mm (C+D). In the lumbar spine, 270 (99%) were either completely within the cortex or less than 2mm exposed (classified as A or B). The nadir of pedicle width was at T4. From L1 to L5, measured pedicle width also rose. This pattern was followed, although it was less profound, when screw diameter was measured in the lumbar spine (and even less so in the thoracic vertebrae). The height of pedicles was noted to progressively increase, peaking at the thoraco-lumbar junction. The mid thoracic region was associated with screws occupying the greatest proportion of pedicle diameter. Discussion/Conclusion. The use of pedicle screws in the thoracic and lumbar spine remains relatively safe. The accuracy of navigated insertion was found to compare well to previous series’. Although there is some association between the anatomical dimensions of pedicles and the dimensions of screws, this doesn't seem to be a strong association. Based on the findings in this series, future studies that relate the long term outcome (e.g. failure or screw loosening) with proportion of pedicle diameter taken up by a screw may be warranted


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 19 - 19
1 May 2012
Mohanram Y Kirkham J Yang X
Full Access

Introduction. P-15 (GTPGPQGIAGQRGVV), a fifteen residue synthetic peptide, is a structural analogue of the cell binding domain of Type 1 collagen and creates a biomimetic environment for bone repair when immobilized on anorganic bovine mineral (ABM) scaffolds. ABM-P-15 scaffolds have been shown to enhance bone marrow stromal cell growth and differentiation. This study aimed at evaluating the osteogenic potential of human dental pulp stromal cells (HDPSCs) compared to human bone marrow stromal cells (HBMSCs) in monolayer and on 3D ABM-P-15 scaffolds in vitro and in vivo. Materials and Methods. HDPSCs and HBMSCs were cultured as monolayers in basal or osteogenic media for 3 weeks. Osteogenic differentiation was confirmed using alkaline phosphatase (ALP) staining and ALP specific activity (ALPSA). In addition, the presence and distribution of osteogenic markers including Type 1 collagen, bone sialoprotein (BSP), osteopontin (OPN) and osteocalcin (OCN) was determined by immunohistochemisty. Gene expression for COL1, RUNX2 and OCN was determined using RT-PCR after 1, 3 and 5 weeks in basal culture. For 3D culture, HDPSCs were seeded on ABM scaffolds ± P-15 (CeraPedics LLC) and cultured in basal media for 6 weeks. Cell viability and growth were visualized by confocal and scanning electron microscopy. Osteogenic differentiation was confirmed by ALP staining and ALPSA. For in vivo studies, HDPSCs were injected and sealed in diffusion chambers containing ABM-P-15 or ABM alone which were then implanted intraperitoneally in nude mice for 8 weeks. The retrieved samples were then processed for histology. Results. In monolayers, HDPSCs showed stronger ALP staining compared to HBMSCs in both culture conditions. Type I collagen, BSP and OPN were detected by immunohistochemistry for both HBMSCs and HDPSCs; however, OCN was not detected. RT-PCR indicated an up regulation of all osteogenic markers in both cell types at weeks 1 and 3. At week 5, there was a marked down regulation of COL1 and RUNX2 in HDPSCS compared to HBMSCs. Confocal microscopy and SEM showed ABM-P-15 promoted HDPSCs bridge formation between the scaffold particles. Histological staining and biochemical analysis confirmed that P-15 enhanced HDPSC ALP activity in vitro and fibrillar collagen formation in vivo compared to ABM alone. Discussion and Conclusion. HDPSCs have higher osteogenic capacity compared to HBMSCs. ABM-P-15 enhanced HDPSC ALPSA and collagen formation, suggesting that a combination of ABM-P15 with HDPSCs could be used as an autologous cell based therapy for bone tissue engineering. Acknowledgement: Supported by a University of Leeds studentships and Cerapedics Inc


Bone & Joint Research
Vol. 7, Issue 2 | Pages 173 - 178
1 Feb 2018
Peng X Wu X Zhang J Zhang G Li G Pan X

Osteoporosis is a systemic skeletal disorder characterized by reduced bone mass and deterioration of bone microarchitecture, which results in increased bone fragility and fracture risk. Casein kinase 2-interacting protein-1 (CKIP-1) is a protein that plays an important role in regulation of bone formation. The effect of CKIP-1 on bone formation is mainly mediated through negative regulation of the bone morphogenetic protein pathway. In addition, CKIP-1 has an important role in the progression of osteoporosis. This review provides a summary of the recent studies on the role of CKIP-1 in osteoporosis development and treatment.

Cite this article: X. Peng, X. Wu, J. Zhang, G. Zhang, G. Li, X. Pan. The role of CKIP-1 in osteoporosis development and treatment. Bone Joint Res 2018;7:173–178. DOI: 10.1302/2046-3758.72.BJR-2017-0172.R1.