Advertisement for orthosearch.org.uk
Results 1 - 20 of 270
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 40 - 48
1 Jan 2016
Matharu GS Mansour R Dada O Ostlere S Pandit HG Murray DW

Aims. The aims of this study were to compare the diagnostic test characteristics of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI) alone, and ultrasound combined with MARS-MRI for identifying intra-operative pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients undergoing revision surgery. . Methods. This retrospective diagnostic accuracy study involved 39 patients (40 MoMHRs). The time between imaging modalities was a mean of 14.6 days (0 to 90), with imaging performed at a mean of 5.3 months (0.06 to 12) before revision. The prevalence of intra-operative pseudotumours was 82.5% (n = 33). Results. Agreement with the intra-operative findings was 82.5% (n = 33) for ultrasound alone, 87.5% (n = 35) for MARS-MRI alone, and 92.5% (n = 37) for ultrasound and MARS-MRI combined. The diagnostic characteristics for ultrasound alone and MARS-MRI alone reached similar sensitivities (90.9% vs 93.9%) and positive predictive values (PPVs; 88.2% vs 91.2%), but higher specificities (57.1% vs 42.9%) and negative predictive values (NPVs; 66.7% vs 50.0%) were achieved with MARS-MRI. Ultrasound and MARS-MRI combined produced 100% sensitivity and 100% NPV, whilst maintaining both specificity (57.1%) and PPV (91.7%). For the identification of a pseudotumour, which was confirmed at revision surgery, agreement was substantial for ultrasound and MARS-MRI combined (κ = 0.69), moderate for MARS-MRI alone (κ = 0.54), and fair for ultrasound alone (κ = 0.36). Discussion. These findings suggest that ultrasound and/or MARS-MRI have a role when assessing patients with a MoMHR, with the choice dependent on local financial constraints and the availability of ultrasound expertise. However in patients with a MoMHR who require revision, combined imaging was most effective. Take home message: Combined imaging with ultrasound and MARS-MRI always identified intra-operative pseudotumours if present. Furthermore, if neither imaging modality showed a pseudotumour, one was not found intra-operatively. Cite this article: Bone Joint J 2016;98-B:40–8


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 1 - 1
1 Jan 2013
Ul Haq M Soames R Pillai A
Full Access

Introduction

Peroneal tendon subluxation & dislocation is a rare phenomenon. It is a commonly misdiagnosed cause of lateral ankle pain and instability.

Aim(s)

Our aim was to establish the morphometric (quantification of components) features of retromalleolar fibular groove in cadavers using 3D technique.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1196 - 1201
1 Nov 2022
Anderson CG Brilliant ZR Jang SJ Sokrab R Mayman DJ Vigdorchik JM Sculco PK Jerabek SA

Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods. Methods. In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance. Results. Comparison of the mean postoperative femoral stem version measurements between CT and 3D hipEOS showed no significant difference (p = 0.862). In addition, the two version measurements were strongly correlated (r = 0.95; p < 0.001), and the mean paired difference in postoperative femoral version for CT scan and 3D biplanar radiography was -0.09° (95% confidence interval -1.09 to 0.91). Only three stem measurements (6.7%) were considered outliers with a > 5° difference. Conclusion. Our study supports the use of low-dose biplanar radiography for the postoperative assessment of femoral stem version after THA, demonstrating high correlation with CT. We found no significant difference for postoperative femoral version when comparing CT to 3D EOS. We believe 3D EOS is a reliable option to measure postoperative femoral version given its advantages of lower radiation dosage and shorter examination time. Cite this article: Bone Joint J 2022;104-B(11):1196–1201


Bone & Joint Research
Vol. 10, Issue 12 | Pages 759 - 766
1 Dec 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. Methods. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC). Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus of ≥ one cortex on the 3D reconstruction and when present all achieved union. Compared to six-week radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8% sensitive and 100% specific to predict union). At 12 weeks, nine patients had bridging callus at ≥ one cortex on 3D reconstruction (100%-sensitive and 100%-specific to predict union). Presence of sonographic bridging callus on 3D reconstruction demonstrated excellent reviewer agreement on ICC at 0.87 (95% confidence interval 0.74 to 0.96). Conclusion. 3D fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to enhance the usability and accuracy of identification of early fracture healing. Cite this article: Bone Joint Res 2021;10(12):759–766


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 45 - 45
17 Nov 2023
Rix L Tushingham S Wright K Snow M
Full Access

Abstract. Objective. A common orthopaedic pain found in a wide spectrum of individuals, from young and active to the elderly is anterior knee pain (AKP). It is a multifactorial disorder which is thought to occur through muscular imbalance, overuse, trauma, and structural malalignment. Over time, this can result in cartilage damage and subsequent chondral lesions. Whilst the current gold standard for chondral lesion detection is MRI, it is not a highly sensitive tool, with around 20% of lesions thought to be mis-diagnosed by MRI. Single-photon emission computerised tomography with conventional computer tomography (SPECT/CT) is an emerging technology, which may hold clinical value for the detection of chondral lesions. SPECT/CT may provide valuable diagnostic information for AKP patients who demonstrate absence of structural change on other imaging modalities. This review systematically assessed the value of SPECT/CT as an imaging modality for knee pain, and its ability to diagnose chondral lesions for patients who present with knee pain. Methods. Using PRISMA guidelines, a systematic search was carried out in PubMed, Science Direct, and Web of Knowledge, CINAHL, AMED, Ovid Emcare and Embase. Inclusion criteria consisted of any English language article focusing on the diagnostic value of SPECT/CT for knee chondral lesions and knee pain. Furthermore, animal or cadaver studies, comparator technique other than SPECT/CT or patients with a pathology other than knee chondral lesions were excluded from the study. Relevant articles underwent QUADAS-2 bias assessment. Results. 11,982 manuscripts were identified, and the titles were screened for relevance. Seven studies were selected as being appropriate and were subjected to QUADAS-2 assessment. All 7 articles scored low for bias. Two papers deemed that the ICRS score of chondral lesions at intraoperative assessment correlated with SPECT/CT tracer uptake. Two studies concluded that MRI significantly correlated with SPECT/CT tracer uptake, with some instances whereby SPECT/CT identified more chondral lesions than MRI. Two papers compared bone scintigraphy (BS) to SPECT/CT and concluded that SPECT/CT was not only able to identify more chondral lesions than BS, but also localise and characterise the lesions. Conclusion. Evidence implies that SPECT/CT may be a useful imaging modality for the detection and localisation of cartilage lesions, particularly in discrepant cases whereby there is an absence of lesions on other imaging modalities, or a lack of correspondence with patients’ symptoms. More studies would be of value to confirm the conclusions of this review. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 12 - 18
1 Jan 2022
Weil S Arnander M Pearse Y Tennent D

Aims. The amount of glenoid bone loss is an important factor in deciding between soft-tissue and bony reconstruction when managing anterior shoulder instability. Accurate and reproducible measurement of glenoid bone loss is therefore vital in evaluation of shoulder instability and recommending specific treatment. The aim of this systematic review is to identify the range methods and measurement techniques employed in clinical studies treating glenoid bone loss. Methods. A systematic review of the PubMed, MEDLINE, and Embase databases was undertaken to cover a ten-year period from February 2011 to February 2021. We identified clinical studies that incorporated bone loss assessment in the methodology as part of the decision-making in the management of patients with anterior shoulder instability. The Preferred Reporting Items for Systematic Reviews (PRISMA) were used. Results. A total of 5,430 articles were identified from the initial search, of which 82 studies met the final inclusion criteria. A variety of imaging methods were used: three studies did not specify which modality was used, and a further 13 used CT or MRI interchangeably. There was considerable heterogeneity among the studies that specified the technique used to quantify glenoid bone loss. A large proportion of the studies did not specify the technique used. Conclusion. This systematic review has identified significant heterogeneity in both the imaging modality and method used to measure glenoid bone loss. The recommendation is that as a minimum for publication, authors should be required to reference the specific measurement technique used. Without this simple standardization, it is impossible to determine whether any published paper should influence clinical practice or should be dismissed. Cite this article: Bone Joint J 2022;104-B(1):12–18


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 44 - 44
23 Feb 2023
Kruger P Lynskey S Sutherland A
Full Access

The attitudes of orthopaedic surgeons regarding radiology reporting is not well-described in the literature. We surveyed Orthopaedic Surgeons in Australia and New Zealand to assess if they routinely review formal radiology reports. An anonymized, 14 question online survey was distributed to consultant surgeons of the Australian and New Zealand Orthopaedic Associations (AOA, NZOA). Two hundred respondents completed the survey (Total number of Fellows: 283 NZOA, 1185 AOA). 18.5% of respondents always reviewed the formal Radiology report, 44.5% most of the time, 35% sometimes and 2% never. By imaging modality, MRI reports were the most frequently reviewed (92%), followed by ultrasound (74%) and nuclear medicine (63%). Only 10% of surgeons consulted formal reports for plain radiography. 55% of surgeons were still likely to disagree with the MRI report, followed by 46% for plain radiography. In cases of disagreement, only 21% of surgeons would always contact the reporting radiologist. The majority of Surgeons (85.5%) think there should be more collaboration between the disciplines, although only 50.5% had regular attendance of a Radiologist at their departmental audit. This survey reveals that the majority of orthopaedic surgeons are not routinely reading radiology reports. This points towards a need for further interdisciplinary collaboration. To our knowledge, this is the first survey directly assessing attitudes of orthopaedic surgeons towards radiology reports


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 26 - 26
23 Apr 2024
Aithie J Herman J Holt K Gaston M Messner J
Full Access

Introduction. Limb deformity is usually assessed clinically assisted by long leg alignment radiographs and further imaging modalities (MRI and CT). Often decisions are made based on static imaging and simple gait interpretation in clinic. We have assessed the value of gait lab analysis in surgical decision making comparing surgical planning pre and post gait lab assessment. Materials & Methods. Patients were identified from the local limb reconstruction database. Patients were reviewed in the outpatient clinic and long leg alignment radiographs and a CT rotational limb profile were performed. A surgical plan was formulated and documented. All patients then underwent a formal gait lab analysis. The gait lab recommendations were then compared to the initial plan. Results. Twelve patients (8 female) with mean age of 14 (range 12–16) were identified. Nine were developmental torsional malalignments, one arthrogryposis, one hemiparesis secondary to spinal tumour resection and one syndromic limb deficiency. The gait lab recommended conservative management in four patients and agreed with eight surgical plans with one osteotomy level changing. Five patients are post-operative: two bilateral distal tibial osteotomies, two de-rotational femoral osteotomy with de-rotational tibial osteotomies and one bilateral femoral de-rotational osteotomies. Conclusions. Limb deformity correction is major surgery with long rehabilitation and recovery period. Gait lab analysis can identify who would benefit from conservative management rather than surgery with our study showing changes to surgical planning in one third of patients. The gait lab analysis helps to identify patients with functional and neuromuscular imbalances where correcting the bony anatomy may not actually benefit the patient


Long femoral nails for neck of femur fractures and prophylactic fixation have a risk of anterior cortex perforation. Previous studies have demonstrated the radius of curvature (ROC) of a femoral nail influencing the finishing point of a nail and the risk of anterior cortex perforation. This study aims to calculate a patients femoral ROC using preoperative XR and CT and therefore nail finishing position. We conducted a retrospective study review of patients with long femoral cephalomedullary nailing for proximal femur fractures (OTA/AO 31(A) and OTA/AO 32) or impending pathological fractures at a level 1 trauma centre between January 1, 2015 and December 31, 2020 with both full length lateral X-ray and CT imaging. Femoral ROC was calculated on both imaging modalities. Outcomes measured including nail finishing position, anterior cortex encroachment and impingement. The mean femoral ROC was 1026mm on CT and 1244mm on XR. CT femoral ROC strongly correlated with nail finishing point with a spearmans coefficient of 0.77. Additionally, femurs with a ROC <1000mm were associated with a higher risk of anterior encroachment (OR 6.12) and femurs with a ROC <900mm were associated with a higher risk of anterior cortex impingement (OR 6.47). To our knowledge this is the first study to compare a measured femoral ROC to nail finishing position. The use of CT to measure femoral ROC and to a lesser extent XR was able to predict both nail finishing position and risk of anterior cortex encroachment. Preoperative XRs and CTs were able to identify patients with a small femoral ROC. This predicted patients at risk of anterior cortex impingement, anterior cortex encroachment and nail finishing position. We may be able to select femoral nails that resemble the native femoral ROC and mitigate the risk of anterior cortex perforation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 66 - 66
1 Oct 2022
Hulsen D Arts C Geurts J Loeffen D Mitea C
Full Access

Aim. Magnetic resonance imaging (MRI) and 2-[. 18. F]-fluoro-2-deoxy-D-glucose (. 18. F-FDG) Positron Emission Tomography, paired with Computed Tomography (PET/CT) are two indicated advanced imaging modalities in the complicated diagnostic work-up of osteomyelitis. PET/MRI is a relatively novel hybrid modality with suggested applications in musculoskeletal infection imaging. The goal of this study was to assess the value of hybrid . 18. F-FDG PET/MRI for chronic osteomyelitis diagnosis and surgical planning. Method. Five suspected chronic osteomyelitis patients underwent a prospective . 18. F-FDG single-injection/dual-imaging protocol with hybrid PET/CT and hybrid PET/MR. Diagnosis and relevant clinical features for the surgeon planning treatment were compared. Subsequently, 36 patients with . 18. F-FDG PET/MRI scans for suspected osteomyelitis were analysed retrospectively. Sensitivity, specificity, and accuracy were determined with the clinical assessment as the ground truth. Standardized uptake values (SUV) were measured and analysed by means of receiver operating characteristics (ROC). Results. The consensus diagnosis was identical for PET/CT and PET/MRI in the prospective cases, with PET/CT missing one clinical feature. The retrospective analysis yielded a sensitivity, specificity, and accuracy of 78%, 100%, and 86% respectively. Area under the ROC curve was .736, .755, and.769 for the SUVmax, target to background ratio, and SUVmax_ratio respectively. These results are in the same range and not statistically different compared to diagnostic value for . 18. F-FDG PET/CT imaging of osteomyelitis in literature. Conclusions. Based on our qualitative comparison, reduced radiation dose, and the diagnostic value that was found, the authors propose . 18. F-FDG PET/MRI as an alternative to . 18. F-FDG PET/CT in osteomyelitis diagnosis, if available


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 120 - 120
4 Apr 2023
Joumah A Cowling P
Full Access

Though retear rates following rotator cuff repair are well established, we set out to review current literature to determine when early retears occurred (defined as <12m following surgery), and examine which pre- and post-operative variables might affect outcome. Pubmed, Medline, and CINAHL were searched for literature published from 2011 to 2021 using specific search terms. The inclusion criteria were studies reporting retear rates within 12 months of initial surgical repair. Exclusionary criteria were studies that included partial thickness tears, and studies that did not use imaging modalities within 12 months to assess for retears. PRISMA guidelines were followed, identifying a total of 10 papers. A combined total of 3372 shoulders included (Mean age 56 −67 years). The most common modality used to identify early retears were ultrasound scan and MRI. 6 of the 10 studies completed imaging at 0-3 months, 6 studies imaged at 3-6 months and 6 studies imaged at 6-12 months. Across all studies, there was a 17% early retear rate (574 patients). Of these, 13% occurred by 3 months, whilst the peak for retears occurred at 3-6 months (82%) and 5% occurred at 6-12 months. The risk of retear was higher in larger tears and extensive tendon degeneration. All studies apart from one documented a return to work/sport at 6 months post-operatively. Postoperative rehabilitation does not appear to alter retear rate, although data is limited with only 1 of 10 studies allowing active range of movement before 6 weeks. Retorn tendons had poorer functional outcomes compared to intact tendons at 12m following initial repair. The majority of early retears occur at 3-6 months and this time period should be prioritised both in rehabilitation protocols and future research. Age, tear size, and tendon degeneration were found to influence likelihood of early retears


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims. The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty. Methods. Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output. Results. The results revealed that the US bone models were accurate compared with the CT models (root mean squared error (RM)S: femur, 1.07 mm (SD 0.15); tibia, 1.02 mm (SD 0.13). Additionally, femoral landmarking proved to be accurate (transepicondylar axis: 1.07° (SD 0.65°); posterior condylar axis: 0.73° (SD 0.41°); distal condylar axis: 0.96° (SD 0.89°); medial anteroposterior (AP): 1.22 mm (SD 0.69); lateral AP: 1.21 mm (SD 1.02)). Tibial landmarking errors were slightly higher (posterior slope axis: 1.92° (SD 1.31°); and tubercle axis: 1.91° (SD 1.24°)). For implant sizing, 90% of the femora and 60% of the tibiae were sized correctly, while the remainder were only one size different from the required implant size. No difference was observed between moderate and skilled users. Conclusion. The 3D US bone models were proven to be closely matched compared with CT and suitable for preoperative planning. The 3D US is radiation-free and offers numerous clinical opportunities for bone visualization rapidly during clinic visits, to enable preoperative planning with implant sizing. There is potential to extend its application to 3D dynamic ligament balancing, and intraoperative registration for use with robots and navigation systems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):81–86


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1189 - 1196
1 Jul 2021
Murray IR Makaram NS Rodeo SA Safran MR Sherman SL McAdams TR Murray AD Haddad FS Abrams GD

Aims. The aim of this study was to prepare a scoping review to investigate the use of biologic therapies in the treatment of musculoskeletal injuries in professional and Olympic athletes. Methods. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews and Arksey and O’Malley frameworks were followed. A three-step search strategy identified relevant published primary and secondary studies, as well as grey literature. The identified studies were screened with criteria for inclusion comprising clinical studies evaluating the use of biologic therapies in professional and Olympic athletes, systematic reviews, consensus statements, and conference proceedings. Data were extracted using a standardized tool to form a descriptive analysis and a thematic summary. Results. A total of 202 studies were initially identified, and 35 met criteria for the scoping review; 33 (94.3%) were published within the last eight years, and 18 (51.4%) originated from the USA. Platelet rich plasma was the most studied biologic therapy, being evaluated in 33 (94.3%) studies. Ulnar collateral ligament and hamstring injuries were the conditions most studied (nine (25.7%) studies and seven (20.0%) studies, respectively). Athletes most frequently participated in baseball, soccer, and American football. Only two (5.7%) studies were level 1 evidence, with interpretation and comparison between studies limited by the variations in the injury profile, biologic preparations, and rehabilitation protocols. Conclusion. There is diverse use of biologic therapies in the management of musculoskeletal injuries in professional and Olympic athletes. There is currently insufficient high-level evidence to support the widespread use of biologic therapies in athletes. Further research priorities include the development of condition/pathology-specific preparations of biologic therapies, and of outcome measures and imaging modalities sufficiently sensitive to detect differences in outcomes, should they exist. Cite this article: Bone Joint J 2021;103-B(7):1189–1196


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 1 - 1
1 Mar 2022
Lacey A Chiphang A
Full Access

16 to 34% of the population suffer from shoulder pain, the most common cause being rotator cuff tears. NICE guidance recommends using ultrasound scan (USS) or MRI to assess these patients, but does not specify which is preferable. This study assesses the accuracy of USS and MRI in rotator cuff tears in a DGH, to establish the most appropriate imaging modality. Patients who had at least two of shoulder ultrasound, MRI or arthroscopy within a seven month period (n=55) were included in this retrospective study. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated using arthroscopy as the true result, and kappa coefficients calculated for each pairing. 59 comparisons were made in total. Sensitivity for MRI in full supraspinatus tears was 0.83, and for USS 0.75. Specificity for MRI in these tears was 0.75, and for USS 0.83. Values were much lower in other tears, which occurred less frequently. USS and MRI completely agreed with each other 61.3% of the time. Both modalities were only completely accurate 50% of the time. Kappa coefficient between arthroscopy and MRI for supraspinatus tears was 0.658, and for USS was 0.615. There was no statistical difference between MRI and USS sensitivity or specificity (p=1), suggesting that one modality cannot be recommended over the other for full supraspinatus tears. They also do not tend to corroborate one another, suggesting that there is no benefit from doing both scans. Further research is needed to see how both modalities can be improved to increase their accuracy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 75 - 75
1 May 2012
Bucknill A Yam T Campton L Robertson P de Steiger R
Full Access

FAI has been implicated in the progression of osteoarthritis (OA) and early detection may allow for treatment, which can slow or halt progression. FAI is a difficult condition to image and there is little objective evidence about imaging accuracy. We aim to measure the accuracy of five imaging modalities. Three blinded observers retrospectively reviewed five different modalities from two age and sex matched groups: A patient group referred to the outpatient clinic with a clinical diagnosis of FAI and a control group who had had CT scans of the pelvis for suspected trauma, where the Pelvic scan had been reported as showing no injuries. The imaging modalities were: Standard x-ray; Antero-Posterior, Lateral; Condition-specific x-ray projections; Dunn view, lateral internal rotation; Standard Computer Tomography (CT) multiplanar reconstruction (MPR); axial, sagittal and coronal; Condition-specific CT MPR; angled axial, angled coronal; 3D modelling; and surface rendered dynamic. We found marked variations in the sensitivity, specificity, Positive Predictive Value (PPV) and Negative Predictiive Value (NPV) for each of the following imaging modalities: Standard X-ray; Sensitivity 51.9; Specificity; 57.1; PPV; 40; NPV; 68.3 Special X-rays; Sensitivity; 66.7; Specificity; 57.1; PPV; 46.1; NPV; 75.7. Standard CT MPR; Sensitivity; 40.7; Specificity; 75.5; PPV; 47.8; NPV; 69.8 Special CT MPR; Sensitivity; 48.1; Specificity; 57.1; PPV; 46.4; NPV; 70.8 Dynamic 3D CT models; Sensitivity; 55.6; Specificity; 69.3; PPV; 42.8; and NPV; 71.8. The Dynamic 3D CT models (where the observer can manipulate the model in real time three dimension to control the perspective) proved to be the most accurate, closely followed by the special X-Ray views, which were also the most sensitive. The Standard CT MPRs were the most specific but had a low sensitivity. This is the first study to measure sensitivity, specificity and PPV and NPV for these imaging modalities in FAI. We recommend the use of condition-specific X-Ray views as well as 3D CT Models for optimal imaging accuracy in this condition. Standard X-Ray views and CTs proved less useful


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 89 - 89
1 Mar 2017
Plate J Shields J Bolognesi M Seyler T Lang J
Full Access

Introduction. The number of complex revision total hip arthroplasties (THA) is predicted to rise. The identification of acetabular bone defects prior to revision THA has important implications on technique and complexity of acetabular reconstruction. Paprosky et al. proposed a classification system including 3 main types with up to 3 subtypes focused on the integrity of the superior rim of the acetabulum and medial wall. However, the classification system is complex and its reliability has been questioned. The purpose of this study was to evaluate the effectiveness of different radiologic imaging modalities (plain radiographs, 2-D CT, 3-D CT reconstructions) in classifying acetabular defects in revision hip arthroplasty cases and their value of at different levels of orthopaedic training. Methods. Patients treated with revision total hip arthroplasty for acetabular bone defects between 2002–2012 were identified and 22 cases selected that had plain radiographs, 2-D CT and 3-D reconstructions available. Bone defects were classified independently by two fellowship-trained adult reconstruction surgeons. Representative sections were chosen and compiled into a timed presentation. Thirty-five residents from PGY-1 to PGY-5 and 4 attending orthopaedic surgeons were recruited for this study and received a 15-minute introduction to the classification system. Chi square analysis was utilized to examine the influence of image modality and level of training on the correct classification of acetabular bone loss using the Paprosky classification system with alpha=0.05. Results. The correct classification regardless of imaging of PGY levels was 30%. The level of training did not influence the ability to classify an acetabular defect (p=0.918). Correct classification was significantly influenced by the imaging used. Using x-ray led to 37% correctly identified defects, CT scans to 33% and 3D modeling to 30% of correct answers (p<0.001). For Class 1 defects, x-ray imaging had significantly higher number of correct classification (93%) compared to CT scans (67%) and 3D modeling (31%, p<0.001). Similarly, 2A defects were classified correctly with higher frequency on x-ray (49%) compared to CT scans (36%) or 3D modeling (15%, p=0.007). For type 2B, 2C, 3A and 3B defects, the type of imaging did not influence the frequency of correct answer. The level of training did not influence the frequency of correct classification regardless of the type of defect (p<0.05). However, there was a significant difference based on the defect type (p<0.001). Regardless of level of training or imaging, 64% of observers recognized type 1 defects, compared to only 16% correct recognition of 3B defects. Discussion. In the current study using different image modalities, residents regardless of the level of training were only able to classify 30% of defects correctly using the Paprosky classification system of acetabular defects. Using plain x-rays led to an increased number of correct classification, while regular CT scan and 3D CT reconstructions did not improve accuracy. The cost for advanced imaging when using this classification may not be justified. The Paprosky classification system of acetabular defects can be used for treatment decisions; however, it is complex and residents may require increased education in its use and identification of defects


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims. Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning. Methods. A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts. Results. A total of 59 surgeons completed the survey. For all surgeons, the use of the PSP significantly increased agreement with the experts in glenoid classification (x. 2. = 8.54; p = 0.014) and surgical planning (x. 2. = 37.91; p < 0.001). The additional information provided by the PSP also showed a significantly higher impact on surgical decision-making for surgeons who undertake fewer than ten shoulder arthroplasties annually (p = 0.017). Conclusions. The information provided by PSP has the greatest impact on the surgical decision-making of low volume surgeons (those who perform fewer than ten shoulder arthroplasties annually), and PSP brings all surgeons in to closer agreement with the recommendations of experts for glenoid classification and surgical planning. Cite this article: Bone Joint J 2020;102-B(3):365–370


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 402 - 402
1 Sep 2012
Pastides P El Sallakh S Charalambides C
Full Access

The aim of our study was to compare the clinical versus radiological diagnosis of patients suffering from a Morton's neuroma. Clinical assessments and pre operative radiological imaging of patients who underwent operative procedures for an excision of a Morton's neuroma were retrospectively compared. This review included 43 excised Morton's neuromas from 36 different patients over a period of 68 months, performed by one surgical team. The commonest clinical symptoms were those of pain or tingling on the plantar aspect of the affected webspace on direct palpation (100%), pain of weight bearing (91%) which was relieved by rest (81%) and pain on stretching the toes (79%). The most sensitive clinical sign was a Mulder's click. Our results showed that clinical assessment was the most sensitive method of diagnosing these neuromas (98%). All of our patients had at least one mode of radiological investigation. Ultrasonography was the commonest requested single imaging modality in our series. It was found to have a sensitivity of 90% (28/31). This imaging technique has the disadvantage of being operator dependant, as highlighted by the fact that one of our patients had a correct radiological diagnosis after a repeat ultrasound to the affected area was requested. Magnetic Resonance Image scan is a more expensive technique as it has the advantage of producing static reproducible images. As a single imaging modality, it was found to have a sensitivity of 92% (12/13) in our series. 3 patients had both imaging modalities; initial ultrasound failed to convincingly diagnose a neuroma in 2 cases and in the other case, the initial MRI did not show any pathology. In all these cases, the repeat imaging techniques confirmed the clinical diagnosis. We conclude that there is no absolute requirement for ultrasonography or magnetic resonance imaging in patients who clinically are suspected to have a Morton's neuroma, as the clinical examination was found to be the most sensitive method of diagnosis. We suggest that the two main indications for performing some form of imaging is (a) an unclear clinical assessment and (b) cases when more than one webspace appears to be affected. An ultrasound of the webspaces should be the radiological investigation of choice, followed by a magnetic resonance scanning if any uncertainty still remains


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 15 - 15
1 Dec 2017
Gelderman SJ Jutte PC Boellaard R Kampinga GA Ploegmakers JJ Glaudemans AWJM Wouthuyzen-Bakker M
Full Access

Aim. Diagnosing a prosthetic joint infection (PJI) can be difficult. Several imaging modalities are available, but the choice which technique to use is often based on local expertise, availability and costs. Some centers prefer to use 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) as first imaging modality of choice, but due to a lack of accurate interpretation criteria, FDG-PET is currently not routinely applied for diagnosing PJI. With FDG-PET it is difficult to differentiate between FDG uptake due to reactive inflammation and uptake due to an infection. Since the physiological uptake pattern around a joint prosthesis is not fully elucidated, the aim of this study was to determine: i) the FDG uptake pattern in non-infected total hip prostheses and, ii) to evaluate whether there is a difference in uptake between cemented and non-cemented prostheses. Method. Patients with a primary total hip arthroplasty (1995–2016) without clinical signs of an infection that underwent a FDG-PET for another indication (mainly suspicion of malignancy) were included and retrospectively analysed. Patients in whom the prosthesis was implanted < 6 months prior to FDG-PET were excluded, to avoid post-surgical effects. Scans were visually and quantitatively analysed. Quantitative analysis was performed by calculating maximum and peak standardized uptake values (SUVmax and SUVpeak) by volume of interests (VOIs) at eight different locations around the prosthesis, from which the mean SUV was calculated. SUV was standardized by the liver SUV that was taken as background. Results. A total of 52 scans from 30 patients were analysed, with a median age of the prosthesis of 5.9 years (range 0.5–19.8). Most scans (87%) showed a diffuse uptake pattern around the prosthesis. The standardized median SUVmax and SUVpeak were 0.89 (IQR 0.78–1.16) and 0.64 (IQR=0.55–0.89), respectively. There was a difference in FDG uptake between the cemented (median SUVmax 0.85, IQR=0.77–1.04) and the uncemented prostheses (median SUVmax 1.01, IQR=0.84–2.01) (p=0.026). In uncemented prostheses, there was a positive correlation in time between the age of the prosthesis and the FDG uptake (rs=0.66, p=0.004). This observation was not found in cemented prostheses (rs=0.01, p=0.96). Conclusions. Non-infected total hip prostheses mostly show a diffuse FDG pattern around the prosthesis with a higher FDG uptake in uncemented compared to cemented prostheses. In uncemented prostheses, FDG uptake increases with the age of the implant. These findings may aid in the development of accurate interpretation criteria to better differentiate between inflammation and infection in patients with a prosthetic joint


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 65 - 65
1 Mar 2021
Nicholson J
Full Access

Abstract. Objectives. Three-dimensional visualisation of sonographic callus has the potential to improve the accuracy and accessibility of ultrasound evaluation of fracture healing. The aim of this study was to establish a reliable method for producing three-dimensional reconstruction of sonographic callus. Methods. A prospective cohort of ten patients with a closed tibial shaft fracture managed with intramedullary nailing were recruited and underwent ultrasound scanning at 2-, 6- and 12-weeks post-surgery. Ultrasound B-mode capture was performed using infrared tracking technology to map each image to a three-dimensional lattice. Using echo intensity, semi-automated mapping was performed by two independent reviewers to produce an anatomic three-dimensional representation of the fracture. Agreement on the presence of sonographic bridging callus on three-dimensional reconstructions was assessed using the kappa coefficient. Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus at ≥1 cortex on the three-dimensional reconstruction; when present all united. Compared to radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8%-sensitive and 100%-specific to predict union). At twelve weeks, nine patients had bridging callus at ≥1 cortex on three-dimensional reconstruction and all united (100%-sensitive and 100%-specific to predict union). Compared to radiographs, seven of the nine patients that united had bridging callus. Three-dimensional reconstruction of the anteromedial and anterolateral tibial surface was achieved in all patients, and detection of sonographic bridging callus on the three-dimensional reconstruction demonstrated substantial inter-observer agreement (kappa=0.78, 95% confidence interval 0.29–1.0, p=0.011). Conclusions. Three-dimensional fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to identify impaired healing at an early stage in fracture management. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project