Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 231 - 231
1 Sep 2012
Chana R Esposito C Campbell P Walter W
Full Access

Background. Pseudotumours have been associated with metal-on-metal (MoM) hip replacements. We define it as a solid mass which may have cystic components that is neither neoplastic nor infectious in aetiology. The cause of a pseudotumour is not fully understood but could be due to excessive wear, metal hypersensitivity or due to an as-yet unknown cause. Aim. We present the retrieval analysis of early failure MoM hips revised for pain, loosening or a symptomatic mass. Tissues and implants were examined for the possible causes of failure and pseudotumour formation. Corrosion as a potential new cause for pseudotumour formation will be presented. Methods. A group of 16 MoM hip replacements were collected for retrieval analysis. Six of which had a pseudotumour. An Artificial Hip Profiler (Redlux Ltd) was used to measure wear. Edge loading was determined using the 3D wear data. Tissues were histologically evaluated using a 10-point ALVAL scoring system, which strongly suggests hypersensitivity (1). Cases were assigned to one of three categories: high wear (rates >5m/yr), hypersensitivity or corrosion. Results. Of the 6 pseudotumours, 3 had edge loading, 2 had high ALVAL scores and one had corrosion at the head taper junction. The high wear group, (3 cases) all demonstrated edge loading. Histology revealed more metal wear particles and macrophages, with a low ALVAL score in these cases. Two cases were found to have hypersensitivity with a high ALVAL score, more lymphocytes with less visible wear debris and macrophages. The wear rates were also lower, <4m/yr. One total hip replacement had corrosion at the junction between the head and adaptor taper for the stem. The bearings had low wear and the tissue had extensive necrosis as well as products of corrosion enclosed in fibrin (2). There was no suggestion of hypersensitivity (low ALVAL score). Conclusion. Pseudotumours can be caused by high wear, but if this is ruled out, a hypersensitivity or corrosion product reaction should be considered


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 169 - 169
1 Sep 2012
Repantis T Aroukatos P Bravou V Repanti M Korovessis P
Full Access

Background. An increased incidence of periprosthetic osteolysis, resulting in loss of biologic fixation, has been recently reported in contemporary THAs with low-carbide metal-on-metal compared to metal-on-polyethylene couple bearings. A hypersensitivity reaction due to Co and Cr debris is reported as a potential cause for failure of THAs with high-carbide bearings, but there are no evidence-based data for this reaction in low-carbide metal-on-metal bearings. Questions/purposes. We investigated whether there were differences in immunologic hypersensitivity reactions in retrievals from revised THAs with COP versus MOM bearing couples. Patients and Methods. We compared newly formed capsule and periprosthetic interface membranes retrieved from revision surgery due to aseptic failure in 20 patients with low-carbide bearings and 13 patients with ceramic-on-polyethylene bearings. For control tissue we obtained samples from the hip capsule during the primary THA implantation in 13 patients with low-carbide bearings and seven with ceramic-on-polyethylene. We examined the tissues with conventional histologic and immunohistochemical methods. Results. Compared to the controls and the tissue from patients with ceramic-on-polyethylene bearings, the tissues from patients with low-carbide metal-on-metal bearings were associated with (1) extensive necrosis and fibrin exudation in the newly formed hip capsule and (2) diffuse and perivascular lymphocytic infiltration of a higher degree than in the ceramic-on-polyethylene hips in conventional histologic examination and (3) more T than B cells. Conclusions. The conventional histologic and immunohistochemical findings in tissues retrieved from failed THAs with low-carbide metal-on-metal bearings are consistent with a link between hypersensitivity and osteolysis with low-carbide bearing couple THA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 527 - 527
1 Sep 2012
Borgwardt A Borgwardt L Ribel Madsen S Borgwardt L Zerahn B Borgwardt A
Full Access

In a randomized study of 60 patients allergic reactions are evaluated in three joint prosthesis groups, a resurfacing arthroplasty (ReCap), a non-cemented, large metal-on-metal head (Bimetric Magnum) and a non-cemented, alumina ceramic-on-ceramic bearing in a titanium shell (Bimetric C2a). The inclusion criteria were osteoarthritis, ASA I–II, MRI-scan without caput necrosis, DXA-scan without osteoporosis. The exclusion criteria were short neck (<2cm.), large cysts (>1cm.), medical treatment affecting the bone metabolism, severe deformity of the femoral head, impaired kidney function and inability to co-operate. Blood samples were drawn prior to and 6 weeks, 6 months, 1 year, and 3 years after surgery; two tubes from which plasma was prepared, and two tubes for serum. From the last included 20 patients in each group was also taken blood one and three years after surgery for an in vitro lymphocyte assay for scoring of possible hypersensitivity to prosthesis metals. The isolated lymphocytes were subjected to measurement of proliferation and expression of CD69 by flow cytometry and measurement of the Migration Inhibitory Factor (MIF) by ELISA. Plasma concentrations of the cytokines IL-1, IL-4, IL-6, IL-8, IL-12p70, IL-15, interferon-and osteoprotegerin were determined by multiplex-immunoassay. Serum concentrations of chromium and cobalt were determined by graphite furnace atomic absorption spectrometry. The serum concentrations of chromium and cobalt were lowest in patients with the C2a implant and highest with Magnum, some of these differences were significant at 6 weeks, 6 months, and 1 year after surgery. No patient had a very high serum metal concentration. The values of the variables measured in the in vitro lymphocyte assay mainly changed in the expected direction depending on the concentration of the same metal in the serum sample drawn at the same time, but no significant correlation was seen. One patient had uncertain symptoms of metal hypersensitivity and relatively high serum metal concentrations 3 years after arthroplasty with a Magnum prosthesis and was assessed extraordinarily, and elicited the marginally highest MIF responses in the lymphocyte assay. A strong correlation was found between the plasma concentrations of most cytokines, but the cytokine concentrations were not correlated to contemporary metal concentrations


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 224 - 224
1 Sep 2012
Ebreo D Khan A El-Meligy M Armstrong C Peter V
Full Access

INTRODUCTION. The advantages of large diameter metal on metal total hip arthroplasty (MoM THA) and hip resurfacing arthroplasty are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri-prosthetic osteolysis generated as a result of a biological response to particulate wear debris. No reports in the literature exist as to whether circulating levels of Chromium (Cr) and Cobalt (Co) decrease upon removal of a symptomatic large diameter MoM implant or whether levels remain high due to the effect of metal ions debris left behind in the soft tissues after revision surgery. PATIENTS AND METHODS. Between June 2006 and June 2009 we undertook 44 revision surgeries of both large head MoM THAs (femoral head diameter 38mm) and metal-on-metal hip resurfacings for suspected metallosis. Mean time from original implant to revision was 4 years, 8 months (1yr 4mo–7yr 9mo). The mean follow up evaluation was 2 years and 2 months (1yr 2mo–4 years). Blood samples were taken for whole blood Cr and serum Co according to a recognised protocol and compared with reference levels indicated by the Medicines and Healthcare Regulatory Agency recommendation of less than 7ppb for Cr (130nM/L) and Co (119nM/L). RESULTS. 42 patients were found to have histological evidence of either metal allergy, metal toxicity or foreign body reaction. 2 patients had evidence of infection with no features of metal reaction. 3 patients suffered early dislocation requiring closed reduction. 1 patient had infective complications necessitating Girdlestones. 11 patients were lost to follow up, 8 patients were diagnosed pre operatively on Co and Cr levels in urine or synovial fluid aspirate alone. 23 patients had pre revision blood or serum metal ion level results available for direct comparison. Median serum Co level pre revision was 176.6nM/L, falling post revision to 5.1nM/L (p=<0.001∗). The median whole blood Cr level pre revision was 117nM/L and 19nm/L post revision (p=<0.001∗). Mean Oxford Hip Score was 23.7. DISCUSSION. This study demonstrates that at greater than one year post removal of a large diameter MoM hip implant for the indication of symptomatic metallosis or metal hypersensitivity, metal ion levels fall to almost normal levels and that outcome of revision surgery in terms of patient satisfaction is not adversely affected


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 248 - 248
1 Sep 2012
Su E
Full Access

Hip resurfacing has grown rapidly since its introduction in the United States, as an alternative to total hip replacement in the younger, active patient. Some studies have suggested a steep learning curve and a higher complication rate when compared to THR. Existing studies have originated from the pioneering surgeons, using a specific type of resurfacing implant. The purpose of this study was to look at the experience of a single, non-inventor surgeon with the adoption of hip resurfacing, using 3 different implants. M&M. All consecutive hip resurfacings performed by the senior surgeon between 2004 and 2008 were included, providing a minimum 2 year followup period. 3 different implant types were used; 2 of these were used as part of the clinical trials, and 1 was used after US FDA approval. A total of 560 hip resurfacings were eligible for the study based upon a minimum of 2 year followup. Results. Nine revisions were performed in this cohort (1.6%). 2 were femoral conversions to endoprostheses for femoral neck fracture; 3 additional femoral conversions were done for osteonecrosis of the femoral head. 1 acetabular revision only was performed for malposition. 2 revisions to THR of both the acetabular and femoral components were done for acetabular loosening and excessive metal production (edge loading). There was 1 revision for metal hypersensitivity. Overall, the K-M survival curve is 98.1% at 4 years. There was no difference with regard to survival from additional surgery with regard to the different implant types. Radiographic signs of failure were also documented. In this cohort, 3 femoral and 1 acetabular components were identified to be radiographically loose, giving a K-M survival from clinical and radiographic failure to be 96.8% at 4 years. Discussion. Hip resurfacing can be adopted successfully with a low rate of reoperation, by the use of careful patient selection. A single surgeon's experience with 3 different types of implants demonstrated no difference in clinical results between the devices


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 185 - 185
1 Sep 2012
Von Knoch F Neuerburg C Impellizzeri F Goldhahn J Frey P Naal F Von Knoch M Leunig M
Full Access

Background. Second-generation high-carbon CoCrMo-alloy metal-on-metal total hip arthroplasty (THA) was introduced in the late 1980s following reports of early loosening, impingement, pronounced wear, and hypersensitivity in the first-generation metal-on-metal articulations. There has been inconsistent data that specifically addresses the clinical performance and longevity of second-generation metal-on-metal THA. The purpose of this study was to evaluate the survival of second-generation metal-on-metal primary THA and to assess the influence of demographic factors on implant survival in a large patient cohort. Methods. One thousand two hundred and seventy second-generation 28 mm metal-on-metal primary THA in 1121 patients were performed at one institution from 1994 to 2004. According to the International Documentation and Evaluation System patients were followed routinely at one year, two years and every five years thereafter. Clinical and radiographic outcome data was prospectively recorded using a hospital joint registry. At a mean follow-up of 6.8 years postoperatively, the probability of survival of THA was estimated using the method of Kaplan and Meier. Relative risk factors for implant failure that included age, gender, BMI, type of implant fixation and size of implant components were calculated using the Cox proportional-hazards model. Results. Sixty three (5%) hips were revised because of aseptic loosening (28 hips), infection (8 hips), periprosthetic fracture (8 hips), recurrent dislocation (8 hips), pain without implant loosening (7 hips) and breakage of the cup (4 hips). The probability of survival at ten years, with revision for any reason as the endpoint, for the THA as a whole was 0.90 (95% confidence interval, 0.87 to 0.94). The probability of survival for the cup was 0.90 (95% confidence interval, 0.86 to 0.93) and for the stem 0.94 (95% confidence interval, 0.91 to 0.97). No demographic factors or covariates were found to significantly affect survivorship. Conclusion. Second-generation metal-on-metal primary THA did not demonstrate a superior probability of survival at ten years compared with previous reports on other weight-bearing surfaces. Based on these findings and with consideration of concerns that relate to putative local and systemic toxicity of metal debris, the use of second-generation metal-on-metal articulations for primary THA remains moot


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 323 - 323
1 Sep 2012
Li C Hussain A Joseph P Kamali A
Full Access

INTRODUCTION. One of the recent advances in the hard-on-hard hip arthroplasty is the development of a new material of diffusion hardened oxidised zirconium (DHOxZr). The DHOxZr material consists of a ceramic layer on the top surface which is supported by a thick oxygen diffusion hardened (DH) zone underneath. With the desired properties of metal substrate, ceramic surface and a gradient structure of the oxygen diffusion zone, the DHOxZr-on-DHOxZr bearing combination is expected to produce low wear and minimal metal ions. This can possibly address the concerns associated with metal hypersensitivity associated with metal on metal bearings and fracture risk associated with ceramics. The aim of this study was to evaluate the wear of DHOxZr-on-DHOxZr as a possible hard on hard bearing combination in hips. METHODS. Three pairs of 50 mm DHOxZr prototype hip joint devices, each consisting of a DHOxZr modular head and a DHOxZr liner were wear tested in a ProSim hip joint simulator under standard testing conditions used by the Implant Development Centre (IDC), Smith & Nephew, Leamington Spa for 5 million cycles (Mc). The flexion/extension was 30° and 15°. The internal/external rotation was ± 10°. The force was Paul-type stance phase loading, with a maximum load of 3 kN and a standard ISO swing phase load of 0.3 kN. The test frequency was 1 Hz. Gravimetric analysis was carried out at 0, 0.5, 1, 2, 3, 4 & 5 million cycles. The lubricant was new born calf serum with 2 g/l sodium azide concentration diluted with de-ionised water to achieve average protein concentration of 20 g/l. Lubricant was changed every 0.25Mc during the first million cycles of the test and at every 0.33 Mc from 1 to 5Mc. RESULTS. A biphasic wear pattern was observed for the DHOxZr on DHOxZr devices during the test, with a running in phase from 0–1 Mc and a steady state phase from 1–5 Mc. At a confidence level of 95%, the mean wear rate was 0.21 ±0.06 mm3/Mc during the running-in stage, and the wear rate was reduced to 0.01 ±0.03 mm3/Mc during the steady state for the device tested. The wear volume loss of the DHOxZr on DHOxZr devices was significantly lower than that generated by CoCrMo metal on metal (MoM) devices (p < 0.05) under identical simulator test conditions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 572 - 572
1 Sep 2012
Khan A Ebreo D El Meligy M Armstrong C Peter V
Full Access

Introduction. The advantages of metal on metal (MOM) hip replacement are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri prosthetic osteolysis generated as a result of a biological response to particulate wear debris. Our aim in this study was to determine whether a steeply inclined acetabular component would give rise to a higher concentration of metal ions. Patients and methods. Between April 2003 and June 2006, 22 patients had MOM hip replacement for osteoarthritis by a single Surgeon. There were 12 male and 10 female patients. The average age at the time of surgery was 56 years (Range: 44–69 years). We divided the 22 patients into 2 groups, one group (A) of 11 patients with the acetabular inclination angle more than 50 degrees and the other group (B) of 11 patients with the angle less than 50 degrees. The inclination of the acetabular cup was measured using a standard AP radiograph of the pelvis. The patients had metal ion levels (blood chromium and serum cobalt) measured at an average follow up of 3.2 years (Range 2.4 to 5 years). Results. Mean blood chromium level in the group A (146 nM/L) was significantly higher (p=0.005) than in Group B (92 nM/L). Mean serum cobalt level in the group A (245 nM/L) was significantly higher (p=0.002) than in Group B (110 nM/L). Discussion. The early to mid term published results of MOM hip replacements have been encouraging. There are, however, a number of concerns about the MOM bearing. Although its wear rate is low, it still releases metal ions into the body particularly cobalt and chromium since most metal on metal bearings are made of a cobalt chromium alloy. The long-term consequences of increased levels of these ions in the body are not known. High concentrations of Co and Cr are toxic and are known to interfere with a number of biological functions. There also have been recent reports of soft tissue reactions with MOM hip replacement. In the light of these concerns, it is important to examine factors which may influence the release of metal ions after MOM hip replacement. It has been reported in the recent literature that the position of the acetabular component will influence the bearing wear inturn leading to the release of metal ions after MOM hip replacement. Our findings indicate that steeply inclined acetabular components with an inclination angle greater than 50 degrees gives rise to higher concentration of metal ions


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 762 - 768
1 Apr 2021
Ban I Kristensen MT Barfod KW Eschen J Kallemose T Troelsen A

Aims

To compare the functionality of adults with displaced mid-shaft clavicular fractures treated either operatively or nonoperatively and to compare the relative risk of nonunion and reoperation between the two groups.

Methods

Based on specific eligibility criteria, 120 adults (median age 37.5 years (interquartile range (18 to 61)) and 84% males (n = 101)) diagnosed with an acute displaced mid-shaft fracture were recruited, and randomized to either the operative (n = 60) or nonoperative (n = 60) treatment group. This randomized controlled, partially blinded trial followed patients for 12 months following initial treatment. Functionality was assessed by the Constant score (CS) (assessor blinded to treatment) and Disability of the Arm, Shoulder and Hand (DASH) score. Clinical and radiological evaluation, and review of patient files for complications and reoperations, were added as secondary outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 529 - 535
1 Apr 2012
Birch R Misra P Stewart MPM Eardley WGP Ramasamy A Brown K Shenoy R Anand P Clasper J Dunn R Etherington J

The outcomes of 261 nerve injuries in 100 patients were graded good in 173 cases (66%), fair in 70 (26.8%) and poor in 18 (6.9%) at the final review (median 28.4 months (1.3 to 64.2)). The initial grades for the 42 sutures and graft were 11 good, 14 fair and 17 poor. After subsequent revision repairs in seven, neurolyses in 11 and free vascularised fasciocutaneous flaps in 11, the final grades were 15 good, 18 fair and nine poor. Pain was relieved in 30 of 36 patients by nerve repair, revision of repair or neurolysis, and flaps when indicated. The difference in outcome between penetrating missile wounds and those caused by explosions was not statistically significant; in the latter group the onset of recovery from focal conduction block was delayed (mean 4.7 months (2.5 to 10.2) vs 3.8 months (0.6 to 6); p = 0.0001). A total of 42 patients (47 lower limbs) presented with an insensate foot. By final review (mean 27.4 months (20 to 36)) plantar sensation was good in 26 limbs (55%), fair in 16 (34%) and poor in five (11%). Nine patients returned to full military duties, 18 to restricted duties, 30 to sedentary work, and 43 were discharged from military service. Effective rehabilitation must be early, integrated and vigorous. The responsible surgeons must be firmly embedded in the process, at times exerting leadership.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 693 - 700
1 May 2010
Makki D Alnajjar HM Walkay S Ramkumar U Watson AJ Allen PW

We carried out a retrospective review of 47 intra-articular fractures of the calcaneum treated by open reduction and internal fixation in 45 patients by a single surgeon between 1993 and 2001. The fractures were evaluated before operation by plain radiographs and a CT scan using Sanders’ classification. Osteosynthesis involved a lateral approach and the use of the AO calcaneal plate. The mean follow-up was for ten years (7 to 15). Clinical assessment included the American Orthopaedic Foot and Ankle Society Score (AOFAS), the Creighton-Nebraska Score, the Kerr, Prothero, Atkins Score and the SF-36 Health Questionnaire. The radiological evaluation consisted of lateral and axial views of the os calcis. Arthritic changes in the subtalar joint were assessed with an internal oblique view and were graded using the Morrey and Wiedeman scale.

There were 18 excellent (38.3%), 17 good (36.2%), three fair (6.3%) and nine poor (19.2%) results. Five patients had a superficial wound infection and five others eventually had a subtalar arthrodesis because of continuing pain. Restoration of Böhler’s angle was associated with a better outcome. The degree of arthritic change in the subtalar joint did not correlate with the outcome scores or Sanders’ classification. Prompt osteosynthesis should be considered for intra-articular fractures of the calcaneum in order to restore the shape of the hindfoot and Böhler’s angle.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 209 - 212
1 Feb 2005
Steele N Dodenhoff RM Ward AJ Morse MH

We prospectively studied the outcome of a protocol of prophylaxis for deep vein thrombosis (DVT) in 103 consecutive patients undergoing surgical stabilisation of pelvic and acetabular fractures. Low-molecular-weight heparin (LMWH) was administered within 24 hours of injury or on achieving haemodynamic stability. Patients were screened for proximal DVT by duplex ultrasonography performed ten to 14 days after surgery.

The incidence of proximal DVT was 10% and of pulmonary embolus 5%. Proximal DVT developed in two of 64 patients (3%) who had received LMWH within 24 hours of injury, but in eight of 36 patients (22%) who received LMWH more than 24 hours after the injury (p < 0.01). We conclude that LMWH, when begun without delay, is a safe and effective method of thromboprophylaxis in high-risk patients with major pelvic or acetabular fractures.