Results 1 - 20 of 87
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 39 - 39
1 Mar 2021
Jimenez-Cruz D Masterson A Dubey M Board T Williams S
Full Access

Abstract. OBJECTIVES. Abnormal joint mechanics have been proposed as adversely affecting natural hip joint tribology, whereby increased stress on the articular cartilage from abnormal loading leads to joint degeneration. The aim of this project was to assess the damage caused by different loading conditions on the articular surfaces of the porcine hip joint in an experimental simulator. METHODS. Porcine hip joints were dissected and mounted in a single station hip simulator (SimSol, UK) and tested under loading scenarios (that corresponded to equivalent of different body mass index's’ (BMI) in humans), as follows:“Normal” (n=4), the loading cycle consisted of a simplified gait cycle based on a scaled version of a simplified twin-peak human gait cycle, the peak load was 900N (representative of a healthy BMI). Representative of an “Overweight” BMI (n=3), as the normal cycle with a peak load of 1,130N Representative of an “Obese” BMI (n=1), as the normal cycle with a peak load of 1,340N Tests were conducted at 1Hz for 14,400 cycles in Ringers solution; photogrammetry was used to characterise the appearance of the cartilage and labrum pre, during and post simulation. the appearance and location of damage was recorded. RESULTS. No significant damage was observed for samples tested under normal conditions. Following “overweight” condition testing, tears and detachment of the labrum were observed during testing in two (of three) samples. In addition to damaged observed in “overweight” tested samples the “obese” showed similar damage and also cartilage bruising and wear tracks on the articular surface of the acetabulum. DISCUSSION. The absence of damage in “normal” loading provides evidence that this is an appropriate methodology and loading regime for porcine hips. Increased damage with increasing loads demonstrates the potential to develop further this experimental simulation to assess adverse loading in natural hip joints. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 95 - 95
2 Jan 2024
Yasuda T Hara S Yamashita S Mitsuzawa S Tsukamoto Y Takeuchi H Ota S Onishi E
Full Access

The interleukin-6/gp130-associated Janus Kinases/STAT3 axis is known to play an important role in mediating inflammatory signals, resulting in production of matrix metalloproteinase-3 (MMP-3). The hip joints with rapidly destructive coxopathy (RDC) demonstrate rapid chondrolysis, probably by increased production of MMP-3 observed in the early stage of RDC. In the recent study, no apparent activation of STAT3 has been shown in the synovial tissues obtained from the osteoarthritic joint at operation. However, no data are currently available on STAT3 activation in the synovial tissues in the early stage of RDC. This study aimed to elucidate STAT3 activation in the synovial tissues in the early stage of RDC. Synovial tissues within 7 months from the disease onset were obtained from four RDC patients with femoral head destruction and high serum levels of MMP-3. RDC synovial tissues showed the synovial lining hyperplasia with an increase of CD68-positive macrophages and CD3-positive T lymphocytes. STAT3 phosphorylation was found in the synovial tissues by immunohistochemistry using anti-phospho-STAT3 antibody. The majority of phospho-STAT3-positive cells were the synovial lining cells and exhibited negative expression of macrophage or T cell marker. Treatment with tofacitinib, a Janus Kinase inhibitor, resulted in a decrease in phospho-STAT3-positive cells, especially with high intensity, indicating effective suppression of STAT3 activation in RDC synovial tissues. Inhibitory effect of tofacitinib could act through the Janus Kinase/STAT3 axis in the synovial tissues in the early stage of RDC. Therefore, STAT3 may be a potential therapeutic target for prevention of joint structural damage in RDC. Acknowledgements: This study was supported by Katakami Foundation for Clinical Research


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 40 - 40
1 Mar 2021
Karunaseelan KJ van Arkel R Jeffers J
Full Access

Abstract. Objectives. Hip joint laxity after total hip arthroplasty (THA) has been considered to cause microseparation and lead to complications, including wear and dislocation. In the native hip, the hip capsular ligaments may tighten at the limits of range of hip motion and provide a passive stabilising force preventing edge loading and reduce the risk of dislocation. Previous attempts to characterise mechanical properties of hip capsular ligaments have been largely variable and there are no cadaveric studies quantifying the force contributions of each ligament in different hip positions. In this study we quantify the passive force contribution of the hip capsular ligaments throughout a complete range of motion (ROM). Methods. Nine human cadaveric hip specimens (6 males and 3 females) with mean age of (76.4 ± 9.0 years) were skeletonised, preserving the capsular ligaments. Prepared specimens were tested in a 6 degree of freedom system to assess ROM with 5 Nm torque applied in external and internal rotation throughout hip flexion and extension. Capsular ligaments were resected in a stepwise fashion to assess internal force contributions of the iliofemoral (superior and inferior), pubofemoral, and ischiofemoral ligaments during ROM. Results. In external rotation, the superior and inferior iliofemoral ligament minimum force contributions were (136.52 ± 27.15 N) in flexion and (82.40 ± 27.85 N) in extension, respectively. In internal rotation, the ischiofemoral ligament force contributions were dominant in adducted-flexion positions and abducted-extension positions. Conclusions. These findings provide insights into the primary capsular structures that stabilise the hip joint in different manoeuvres. This data allows for an improved understanding of which capsular ligaments contribute the most to hip stability and has important implications for choosing surgical approaches and repair strategies to minimise complications related to joint instability. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 49 - 49
1 Jan 2017
Augat P Varady P Glitsch U
Full Access

Hip osteoarthritis (OA) is a disorder of high socio-economic relevance. The causes of hip osteoarthritis are multifactorial; however, the epidemiological literature regularly cites occupational tasks, such as heavy lifting and carrying, as a risk factor for the development of hip OA. The level of mechanical stresses upon the hip joint caused by occupational tasks remain largely unclear, however. This project sought to quantify the levels of stresses upon the hip joint during occupational tasks. In particular we were interested in comparing load as well as stress levels from everyday activities with occupational tasks typically performed by blue collar workers. Sectors and occupational activities presenting a high potential for stress upon the hip joint were identified by means of a survey conducted among accident insurance institutions. Lifting, carrying and load transfer (25 to 50 kg), ladder climbing and stair climbing (without additional load and with an additional load of 25 kg) were selected from among these sectors and activities for the purpose of the study. Laboratory measurements were performed in which motion capturing and a range of force measurement apparatus were used to record and evaluate the performance of the selected tasks by 12 skilled workers from a number of sectors. multi-body simulation was used to calculate the stress in the form of hip-joint contact forces. The contact pressures and their geometric distribution on the cartilage surfaces of the hip joint were then calculated from these results by means of finite-element analysis. This produced an indicator for the strain upon the hip joint. The highest hip-joint forces, at (637±148)% of the body weight, occurred during handling of the 50 kg load. This corresponded to 1.7 times the stress arising during walking, at (368±78)% of the body weight. Significantly higher hip-joint forces compared to those arising during walking were observed for the carrying of loads of 40 kg and 50 kg, the handling of loads of 25 kg, 40 kg and 50 kg, and stair climbing with an additional load of 25 kg. Maximum contact pressures of 24.1 MPa were computed during the finite-element analysis (lifting of 50 kg); only very small regions of the joint surface were however affected by these high pressures. During walking, the maximum pressure reached 15 MPa. The results obtained provide a quantitative overview of the strains upon the hip joint during occupational and everyday tasks. They constitute an aid to future quantitative exposure assessments in a range of sectors and occupational fields, and thus contribute to improving estimation of the relevance of stresses of occupational origin to the incidence of hip OA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 13 - 13
1 Apr 2018
Van Houcke J Galibarov PE Fauconnier S Pattyn C Audenaert EE
Full Access

Introduction. A deep squat (DS) is a challenging motion at the level of the hip joint generating substantial reaction forces (HJRF). During DS, the hip flexion angle approximates the functional range of hip motion. In some hip morphologies this femoroacetabular conflict has been shown to occur as early as 80° of hip flexion. So far in-vivo HJRF measurements have been limited to instrumented hip implants in a limited number of older patients performing incomplete squats (< 50° hip flexion and < 80° knee flexion). Clearly, young adults have a different kinetical profile with hip and knee flexion ranges going well over 100 degrees. Since hip loading data on this subgroup of the population is lacking and performing invasive measurements would be unfeasible, this study aimed to report a personalised numerical model solution based on inverse dynamics to calculate realistic in silico HJRF values during DS. M&M. Fifty athletic males (18–25 years old) were prospectively recruited for motion and morphological analysis. DS motion capture (MoCap) acquisitions and MRI scans of the lower extremities with gait lab marker positions were obtained. The AnyBody Modelling System (v6.1.1) was used to implement a novel personalisation workflow of the AnyMoCap template model. Bone geometries, semi-automatically segmented from MRI, and corresponding markers were incorporated into the template human model by an automated nonlinear morphing. Furthermore, a state-of-the-art TLEM 2.0 dataset, included in the Anybody Managed Model Repository (v2.0), was used in the template model. The subject-specific MoCap trials were processed to compute squat motion by resolving an overdeterminate kinematics problem. Inverse dynamics analyses were carried out to compute muscle and joint reaction forces in the entire body. Resulting hip joint loads were validated with measured in-vivo data from Knee bend trials in the OrthoLoad library. Additionally, anterior pelvic tilt, hip and knee joint angles were computed. Results. A preliminary set of results (20 out of 50 subjects) was analysed. The average HJRF was 3.42 times bodyweight at the peak of DS (95% confidence interval: 2.99 – 3.85%BW). Maximal hip and knee flexion angles were 113° (109.7°–116.8°) and 116° (109.4 – 123.0°) respectively. The anterior pelvic tilt demonstrated a biphasic profile with peak value of 33° (28.1° – 38.4°). Discussion. A non-invasive and highly personalised alternative for determining hip loading was presented. Consistently higher HJR forces during DS in young adults were demonstrated as opposed to the Orthoload dataset. Similarly, knee and hip flexion angles were much higher, which could support the increase in HJRF. We can conclude that DS hip kinetics in young adults clearly differ from the typical total hip arthroplasty population


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 105 - 105
1 Nov 2018
Kubo Y Motomura G Ikemura S Hatanaka H Fukushi J Hamai S Yamamoto T Nakashima Y
Full Access

Similar to the radiological findings in rapidly destructive arthrosis of the hip joint (RDA), subchondral insufficiency fracture of the femoral head (SIF) can result in progressive femoral head collapse of unknown etiology. We thus examined the osteoclast activity in hip joint fluid in SIF with progressive collapse in comparison to that in RDA. Twenty-nine hip joint fluid samples were obtained intraoperatively with whole femoral heads from 12 SIF patients and 17 RDA patients. SIF cases were classified into subgroups based on the presence of ≥2mm collapse on preoperative radiographs: SIF with progressive collapse (n=5) and SIF without progressive collapse (n=7). The levels of tartrate-resistant acid phosphatase (TRACP)-5b, interleukin-8, vascular endothelial growth factor (VEGF), and matrix metalloproteinase (MMP)-9 were measured. Numbers of multinuclear giant cells at the subchondral region were assessed histopathologically using mid-coronal slices of each femoral head specimen. Median levels of all markers and median numbers of multinuclear giant cells in SIF with progressive collapse were significantly higher than those in SIF without progressive collapse, while there were no significant differences in SIF with progressive collapse versus RDA. Regression analysis showed that the number of multinuclear giant cells correlated positively with the level of TRACP-5b in joint fluid. This study suggests an association of increased osteoclast activity with the existing condition of progressive collapse in SIF, which was quite similar to the findings in RDA. Therefore, high activation of osteoclast cell may reflect the condition of progressive collapse in SIF as well as RDA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 1 - 1
1 Mar 2013
Nowlan NC Sharp J
Full Access

Developmental dysplasia of the hip (DDH) is the most common post-natal skeletal abnormality. It is widely acknowledged that conditions which cause or result in reduced movement in utero are contributing factors to the incidence of DDH. However, the hypothesis that prenatal movement plays a role in normal development of the hip joint has not been tested using embryonic model systems. This research investigates the effects of immobilization in chick embryos on hip joint morphogenesis. Embryonic chicks were treated in ovo using a neuromuscular blocking agent from embryonic days 5 to 9. Limbs were stained for cartilage using alcian blue, and were scanned in 3-D. Standardized virtual sections of the femur were taken and a number of virtual sections from age-matched limbs were overlaid in order to compare between control and immobilized limbs. The results show that not all immobilised limbs were equally affected, with some immobilised embryos having almost normal joint shapes, and other immobilised embryos displaying decreased protuberance of the femoral head and decreased indentation at the femoral neck. Our results demonstrate that the mechanobiological response to immobilisation can vary between individuals, but also that preventing movement during embryonic development can lead to abnormal morphogenesis of the developing proximal femur in some individuals, providing evidence that reduced movement during development can lead to features of DDH


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 8 - 8
1 Apr 2018
Marques E Fawsitt C Thom H Hunt LP Nemes S Lopez-Lopez J Beswick A Burston A Higgins JP Hollingworth W Welton NJ Rolfson O Garellick G Blom AW
Full Access

Background. Prosthetic implants used in primary total hip replacements have a range of bearing surface combinations (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic, metal-on-metal); head sizes (small <36mm, large 36mm+); and fixation techniques (cemented, uncemented, hybrid, reverse hybrid), which influence prosthesis survival, patient quality of life, and healthcare costs. This study compared the lifetime cost-effectiveness of implants to determine the optimal choice for patients of different age and gender profiles. Methods. In an economic decision Markov model, the probability that patients required one or more revision surgeries was estimated from analyses of UK and Swedish hip joint registries, for males and females aged <55, 55–64, 65–74, 75–84, and 85+ years. Implant and healthcare costs were estimated from hospital procurement prices, national tariffs, and the literature. Quality-adjusted life years were calculated using utility estimates, taken from Patient-Reported Outcome Measures data for hip procedures in the UK. Results. Optimal choices varied between traditionally used cemented metal-on-polyethylene and cemented ceramic-on-polyethylene implants. Small head cemented ceramic-on-polyethylene implants were optimal for males and females aged under 65. The optimal choice for adults aged 65 and older was small head cemented metal-on-polyethylene implants. Conclusions. The older the patient, the higher the probability that small head cemented metal-on-polyethylene implants are optimal. Small head cemented ceramic-on-polyethelyne implants are optimal for adults aged under 65. Our findings can influence NICE guidance, clinical practice, and commissioning of services. Funding. NIHR Research for Patient Benefit programme PB-PG-0613-31032


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 321 - 321
1 Jul 2014
Kang X Wilson D Hodgson A
Full Access

Summary. We found good to excellent reproducibility of in vivo hip joint angle measurements during repeated sitting when derived from registering low-resolution Open MRI imagesets with a reference high-resolution conventional MRI scan, despite only moderate similarity of the segmented volumes. Keywords: hip, kinematics, MRI, femoroacetabular impingement, repeatability. Introduction. Femoroacetabular impingement (FAI) is a mechanical hip disorder caused by an abnormal bony contact between the femur and acetabulum. Open MRIs can enable studies of FAI under weightbearing, but the resolution of such scans is comparatively low, so it is useful to obtain high resolution (HR) reference scans from a conventional MRI and register lower resolution (LR) open MRI images to the HR images. The purpose of this study was to establish the degree of correspondence between the segmented volumes from the two types of scanner and to estimate the repeatability of joint angle measurements. Patients and Methods. Three healthy subjects were scanned in a lying position to obtain high resolution (HR) MRI images of the pelvis, hip and knee. The same subjects were scanned four times in a sitting position in a 0.5T open MRI scanner to obtain corresponding low resolution (LR) images of the hip joint. Between sittings, subjects rose and sat again, and during each sitting, a block was inserted and removed from underneath their foot. Volumetric models of the femur and acetabulum were manually segmented from the HR and LR MRI images. The LR (sitting) models were registered to the HR (supine) models using an intensity-based rigid registration method and the degree of overlap and the femoropelvic joint angles computed. Analysis is complete for two of the three subjects (results for the third are pending). Results. The overlap between the LR and HR imagesets is reasonable in most scan slices - per-slice Dice Similarity Coefficients (DSCs) are typically around 85%, although DSCs near the edges of volumes can sometimes drop to about 75%. Nonetheless, the resulting registrations are relatively insensitive to these moderate discrepancies. For the two subjects whose data has been analyzed to date, the femoral angle relative to the scanner is quite repeatable (SD < 0.9° for the flexion angle under each block condition). The mean femoral flexion angle change between block conditions was also comparatively consistent (SD 1.7° & 2.2° for the two subjects), but most of the other hip joint angles (and changes between the up and down conditions) were more variable (SDs up to ∼5.7°). Discussion/Conclusions. Although there are moderate discrepancies between the LR and HR segmented volumes, the resulting registrations and estimated joint angles are relatively consistent (SDs under 2°). The larger degree of pelvic flexion variability under repositioning indicates that it may be challenging for subjects to reproduce a desired posture on different occasions. Our results could not be directly compared with the only other studies we are aware of using open MRI to investigate FAI because neither combined LR and HR images


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 82 - 82
1 Apr 2017
Palmer J Palmer A Jones L Jackson W Glyn-Jones S Price A
Full Access

Background

Since 2011, the knee service at the Nuffield Orthopaedic Centre has been offering a neutralising medial opening wedge high tibial osteotomy (HTO) to a group of patients presenting with early medial osteoarthritis of the knee, varus alignment and symptoms for more than 2 years. During development of this practice an association was observed between this phenotype of osteoarthritis and the presence of CAM deformity at the hip.

Methods

A retrospective cohort study. All patients who underwent HTO since 2011 were identified (n=30). Comparator groups were used in order to establish whether meaningful observations were being made: Control group: The spouses of a high-risk osteoarthritis cohort recruited for a different study at our unit (n=20) Pre-arthroplasty group: Patients who have undergone uni-compartmental arthroplasty (UKA) for antero-medial osteoarthritis (n=20)All patients had standing bilateral full-length radiographs available for analysis using in house developed Matlab-based software for hip measurements and MediCAD for lower limb alignment measurements.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 120 - 120
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR.

Methods

Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 28 - 28
17 Apr 2023
Jimenez-Cruz D Dubey M Board T Williams S
Full Access

Hip joint biomechanics can be altered by abnormal morphology of the acetabulum and/or femur. This may affect load distribution and contact stresses on the articular surfaces, hence, leading to damage and degradation of the tissue. Experimental hip joint simulators have been used to assess tribology of total hip replacements and recently methods further developed to assess the natural hip joint mechanics. The aim of this study was to evaluate articular surfaces of human cadaveric joints following prolonged experimental simulation under a standard gait cycle. Four cadaveric male right hips (mean age = 62 years) were dissected, the joint disarticulated and capsule removed. The acetabulum and femoral head were mounted in an anatomical hip simulator (Simulation Solutions, UK). A simplified twin peak gait cycle (peak load of 3kN) was applied. Hips were submerged in Ringers solution (0.04% sodium azide) and testing conducted at 1 Hertz for 32 hours (115,200 cycles). Soft tissue degradation was recorded using photogrammetry at intervals throughout testing. All four hips were successfully tested. Prior to simulation, two samples exhibited articular surface degradation and one had a minor scalpel cut and a small area of cartilage delamination. The pre-simulation damage got slightly worse as the simulation continued but no new areas of damage were detected upon inspection. The samples without surface degradation, showed no damage during testing and the labral sealing effect was more obvious in these samples. The fact that no new areas of damage were detected after long simulations, indicates that the loading conditions and positioning of the sample were appropriate, so the simulation can be used as a control to compare mechanical degradation of the natural hip when provoked abnormal conditions or labral tissue repairs are simulated


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 35 - 35
17 Apr 2023
Afzal T Jones A Williams S
Full Access

Cam-type femoroacetabular impingement is caused by bone excess on the femoral neck abutting the acetabular rim. This can cause cartilage and labral damage due to increased contact pressure as the cam moves into the acetabulum. However, the damage mechanism and the influence of individual mechanical factors (such as sliding distance) are poorly understood. The aim of this study was to identify the cam sliding distance during impingement for different activities in the hip joint. Motion data for 12 different motion activities from 18 subjects, were applied to a hip shape model (selected as most likely to cause damage, anteriorly positioned with a maximum alpha angle of 80°). The model comprised of a pointwise representation of the acetabular rim and points on the femoral head and neck where the shape deviated from a sphere (software:Matlab). The movement of each femoral point was tracked in 3D while an activity motion was applied, and impingement recorded when overlap between a cam point and the acetabular rim occurred. Sliding distance was recorded during impingement for each relevant femoral point. Angular sliding distances varied for different activities. The highest mean (±SD) sliding distance was for leg-crossing (42.62±17.96mm) and lowest the trailing hip in golf swing (2.17±1.11mm). The high standard deviation in the leg crossing sliding distances, indicates subjects may perform this activity in a different manner. This study quantified sliding distance during cam impingement for different activities. This is an important parameter for determining how much the hip moves during activities that may cause damage and will provide information for future experimental studies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 60 - 60
17 Nov 2023
Diaz RL Williams S Jimenez-Cruz D Board T
Full Access

Abstract. BACKGROUND. Hemi-arthroplasty (HA) as a treatment for fractured neck of femur has slightly increased since 2019 and remarkably after the COVID pandemic. The main drawback of the treatment is ongoing cartilage deterioration that may require revision to THR. OBJECTIVE. This study assessed cartilage surface damage in hip HA by reproducing anatomical motion and loading conditions in a hip simulator. METHODS. Experimental design. HA tests were conducted using porcine acetabula and CoCr femoral heads. Five groups (n=4) were included: a control group comprising natural tissue and four HA groups where the acetabula were paired with metal heads to allow radial clearance (RC) classed as small (RC<0.6mm), large (2mm<RC<4mm), extra-large (4mm<RC), and oversized (RC<−0.6mm). Tests were carried out in an anatomical hip simulator that reproduced a simplified twin peak gait cycle, adapted for porcine hip joints, from the ISO 14242 standard for wear of THR prostheses (peak load of 900N). The test length was 6 hours, with photogrammetry taken at 1-hour intervals. Ringers solution was used as a lubricant. RESULTS. No changes were observed in the control group. However, cartilage surface changes were observed in all hemi-arthroplasty groups. Discolouration on the cartilage surface was noticeable at the posterior-superior part of the acetabulum after 1-hour (extra-large and oversized groups). Damage severity and location were characteristic of each clearance group. Of all the groups, the oversized group showed more significant damage. No labrum separation was seen after the simulation. CONCLUSIONS. These results are relevant to understand the effect of femoral head clearance on cartilage damage risk after HA. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 139 - 139
4 Apr 2023
Mühling M Sandriesser S Augat P
Full Access

Implant manufacturers develop new products to improve existing fracture fixation methods or to approach new fracture challenges. New implants are commonly tested and approved with respect to their corresponding predecessor products, because the knowledge about the internal forces and moments acting on implants in the human body is unclear. The aim of this study was to evaluate and validate implant internal forces and moments of a complex physiological loading case and translate this to a standard medical device approval test. A finite elements model for a transverse femur shaft fracture (AO/OTA type 32-B2) treated with a locked plate system (AxSOS 3 Ti Waisted Compression Plate Broad, Stryker, Kalamazoo, USA) was developed and experimentally validated. The fractured construct was physiologically loaded by resulting forces on the hip joint from previously measured in-vivo loading experiments (Bergmann et. al). The forces were reduced to a level where the material response in the construct remained linear elastic. Resulting forces, moments and stresses in the implant of the fractured model were analysed and compared to the manufacturers’ approval data. The FE-model accurately predicted the behaviour of the whole construct and the micro motion of the working length of the osteosynthesis. The resulting moment reaction in the working length was 24 Nm at a load of 400 N on the hip. The maximum principle strains on the locking plate were predicted well and did not exceed 1 %. In this study we presented a protocol by the example of locked plated femur shaft fracture to calculate and validate implant internal loading using finite element analysis of a complex loading. This might be a first step to move the basis of development of new implants from experience from previous products to calculation of mechanical behaviour of the implants and therefore, promote further optimization of the implants’ design


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 142 - 142
11 Apr 2023
Algarni M Amin A Hall A
Full Access

Cartilage degeneration and loss are key events in the initiation and progression of osteoarthritis (OA). Changes to chondrocyte volume and morphology (in the form of cytoplasmic processes) and thus cell phenotype are implicated, as they lead to the production of a mechanically-weakened extracellular matrix. The chondrocyte cytoskeleton is intimately linked to cell volume and morphology and hence we have investigated alterations to levels and distribution of chondrocyte F-actin that occur during early OA. The femoral heads (FH) from hip joints (N=16) were obtained with ethical permission and patient consent following femoral neck fracture. Cartilage was assessed as grade 0 (non-degenerate) and grade 1 (superficial fibrillation) using OARSI criteria. In situ chondrocyte volume and F-actin distribution were assessed using the fluorescent indicators (5-chloromethyl fluorescein diacetate (CMFDA)) and phalloidin, and imaged and quantified by confocal microscopy, Imaris. TM. and ImageJ software. There were no differences between the volume or total F-actin levels of in situ chondrocytes within the superficial zone of grade 0 (n=164 cells) compared to grade 1 (n=145) cartilage (P>0.05). However, a more detailed analysis of phalloidin labelling was performed, which demonstrated significant increases in both intense punctuate (IP) or intense areas (IA) (P<0.0001; P=0.0175 respectively). A preliminary analysis of IP and IA F-actin labelling suggested that while the former did not appear to be associated with changes to chondrocyte morphology, most of the cytoplasmic processes were associated with the presence of IA at the starting point of the protrusion. These results demonstrate marked changes to F-actin distribution in chondrocytes in the very early stages of cartilage degeneration as occurs in OA. These subtle changes are probably an early indication of a change to the chondrocyte phenotype and thus worthy of further study as they may lead to deleterious alterations to matrix metabolism and ultimately cartilage weakening


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 93 - 93
11 Apr 2023
de Angelis N Beaule P Speirs A
Full Access

Femoro-acetabular impingement involves a deformity of the hip joint and is associated with hip osteoarthritis. Although 15% of the asymptomatic population exhibits a deformity, it is not clear who will develop symptoms. Current diagnostic imaging measures have either low specificity or low sensitivity and do not consider the dynamic nature of impingement during daily activities. The goal of this study is to determine stresses in the cartilage, subchondral bone and labrum of normal and impinging hips during activities such as walking and sitting down. Quantitative CT scans were obtained of a healthy Control and a participant with a symptomatic femoral cam deformity (‘Bump’). 3D models of the hip were created from automatic segmentation of CT scans. Cartilage layers were added so the articular surface was the mid-line of the joint. Finite element meshes were generated in each region. Bone elastic modulus was assigned element-by-element, calculated from CT intensity converted to bone mineral density using a calibration phantom. Cartilage was modelled as poroelastic, E=0.467 MPa, v=0.167, and permeability 3×10. -16. m. 4. /N s. The pelvis was fixed while rotations and contact forces from Bergmann et al. (2001) were applied to the femur over one load cycle for walking and sitting in a chair. All analyses were performed in FEBio. High shear stresses were seen near the acetabular cartilage-labrum junction in the Bump model, up to 0.12 MPa for walking and were much higher than in the Control. Patient-specific modelling can be used to assess contact and tissue stresses during different activities to better understand the risk of degeneration in individuals, especially for activities that involve high hip flexion. The high stresses at the cartilage labrum interface could explain so-called bucket-handle tears of the labrum


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 79 - 79
1 Dec 2020
Stefanou M Vasilakou A Fryda Z Giannakou S Papadimitriou G Pilichou A Antonis K Anastasopoulos I
Full Access

Purpose. Ultrasound of the neonatal and infantile hip is a useful tool in diagnosis and treatment of the developmental dysplasia of the hip (DDH), especially given the fact that numerous cases of DDH do not present any findings in the clinical examination. Methods. Between January 2014 and May 2020, 10536 (5273 neonates and infants, 53% girls, 47% boys) consecutive neonatal and infantile hip joints were studied using the Graf Hip Ultrasound method. Results. 607 hips were diagnosed as abnormal. 523 (5%) hip joints were type IIA, 18 (0.17%) were type ΙΙΒ, 19 (0.18%) were type ΙΙC, 33 (0.31%) were type ΙΙΙ and 14 (0.13%) were type IV. 72% of patients were girls, 55% of patients were firstborns, 35,7% presented breech, 8,2% had a positive family history of DDH, 6% were part of a multiple pregnancy, while 27,2% had no predisposing factor for the disease. Type ΙΙΑ hips were treated with follow- up only and had all matured (turned to normal- type I hips) within a trimester. Type ΙΙΒ και ΙΙC hips were treated using an abductor harness and were normal (type I) within three months. 35.7% of type ΙΙΙ were treated with an abductor harness and 64.3% with hip spica. All type IV hips were treated with hip spica. The duration of therapy for type III and type IV hips was 3 months. Conclusion. The early use of a hip ultrasound provides us with the ability to diagnose and treat DDH efficiently, resulting in a normal hip joint within the first months of life


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 61 - 61
1 Dec 2021
Naghavi SA Hua J Moazen M Taylor S Liu C
Full Access

Abstract. Objectives. Currently, total hip replacement surgery is an effective treatment for osteoarthritis, where the damaged hip joint is replaced with an artificial joint. Stress shielding is a mechanical phenomenon that refers to the reduction of bone density as a result of altered stresses acting on the host bone. Due to solid metallic nature and high stiffness of the current orthopaedic prostheses, surrounding bones undergo too much bone resorption secondary to stress shielding. With the use of 3D printing technology such as selective laser melting (SLM), it is now possible to produce porous graded microstructure hip stems to mimics the surrounding bone tissue properties. Method. In this study we have compared the physical and mechanical properties of two triply periodic minimal surface (TPMS) lattice structure namely gyroid and diamond TPMS. Based on initial investigations, it was decided to design, and 3D print the gyroid and diamond scaffolds having pore size of 800 and 1100 um respectively. Scaffold of each type of structure were manufactured and were tested mechanically in compression (n=8), tension (n=5) and bending (n=1). Results. Upon FEA validation of the scaffold in Abaqus, the desired scaffold for hip implant application was evaluated to have a young's modules of 12.15 GPa, yield strength of 242 MPa and porosity of 55%. Topology and lattice optimization were performed using nTopology to design an optimised graded porous hip implant based on stress shielding reduction. It was understood that the designed optimised hip implant can reduce the stress shielding effect by more than 65% when compared to the conventional generic implant. Conclusions. The designed hip implant presented in this work shows clinical promise in reducing bone loss while having enhanced osseointegration with the surrounding cortical bones. Hence, this will help reduce the risk of periprosthetic fracture and the probability of revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 142 - 142
1 Nov 2021
Negri S Wang Y Lee S Qin Q Cherief M Hsu GC Xu J Tower RJ Levi B Levin A James A
Full Access

Introduction and Objective. Heterotopic ossification is the formation of extraskeletal mineralized tissue commonly associated with either trauma or surgery. While several mouse models have been developed to better characterize the pathologic progression of HO, no model currently exists to study HO of the hip, the most common location of acquired HO in patients. Owing to the unique biological mechanisms underpinning the formation of HO in different tissues, we sought to develop a model to study the post-surgical HO of the hip. Materials and Methods. Wild-type mice C57BL/6J mice were used to study the procedure outcomes, while Pdgfra-CreERT2;mT/mG and Scx-GFP reporter animals were used for the lineage tracing experiments (total n=16 animals, male, 12 weeks old). An anterolateral approach to the hip was performed. Briefly, a 2 cm incision was made centered on the great trochanter and directed proximal to the iliac crest and distally over the lateral shaft of the femur. The joint was then reached following the intermuscular plane between the rectus femoris and gluteus medius muscles. After the joint was exposed, the articular cartilage was removed using a micropower drill with a 1.2 mm reamer. The medius gluteus and superficial fascia were then re-approximated with Vicryl 5-0 suture (Ethicon Inc, Somerville, NJ) and skin was then closed with Ethilon 5-0 suture (Ethicon Inc). Live high resolution XR imaging was performed every 2 wks to assess the skeletal tissues (Faxitron Bioptics, Tucson, AZ). The images were then scored using the Brooker classification. Ex-vivo microCT was conducted using a Skyscan 1275 scanner (Bruker-MicroCT, Kontich, Belgium). 3D reconstruction and analysis was performed using Dragonfly (ORS Inc., Montreal, Canada). For the histological analysis of specimens, Hematoxylin and Eosin (H&E), modified Goldner's Trichrome (GMT) stainings were performed. Reporter activity was assessed using fluorescent imaging. Results. Substantial periarticular heterotopic bone was seen in all cases. A periosteal reaction and an initial formation of calcified tissue within the soft tissue was apparent starting from 4 wks after surgery. By XR, progressive bone formation was observed within the periosteum and intermuscular planes during the subsequent 8 weeks. Stage 1 HO was observed in 12.5% of cases, stage 2 in 62.5% of cases, and stage 3 HO in 25% of cases. 3D microCT reconstructions of the treated hip joints demonstrated significant de novo heterotopic bone in several location which phenocopy human disease. Heterotopic bone was observed in an intracapsular location, periosteal location involving the iliac bone and proximal femur, and intermuscular locations. Histological analyses further confirmed these findings. To assess the cells which gave rise to HO in this model, an inducible PDGFRα and constitutive Scx-GFP reporter mice were used. A dramatic increase in mGFP reporter activity was noted PDGFRα within the HO injury site, including in areas of new cartilage and bone formation. Scx-associated reporter activity increased in the soft tissue and periosteal periacetabular areas of injured hips. Conclusions. HO has a diverse set of pathologies, of which joint associated HO after elective surgery is the most common. Here, we present the first mouse model of hip dislocation and acetabular reaming that mimics elements of human periarticular HO. The diverse locations of HO after acetabular reaming (intracapsular, intermuscular and periosteal) suggests the activation of different and specific HO program after surgery. Such a field effect would be consistent with local trauma and inflammation, which is a well-studied contributor to HO genesis. Not surprisingly, joint-associated HO significantly derives from PDGFRα-expressing cells, which has been shown to similarly give rise to intramuscular and intratendinous HO