Metal-on-metal hip resurfacing prostheses are a relatively recent intervention for relieving the symptoms of common musculoskeletal diseases such as osteoarthritis. While some short term clinical studies have offered positive results, in a minority of cases there is a recognised issue of femoral fracture, which commonly occurs in the first few months following the operation. This problem has been explained by a surgeon's learning curve and notching of the femur but, to date, studies of explanted early fracture components have been limited. Tribological analysis was carried out on fourteen retrieved femoral components of which twelve were revised after femoral fracture and two for avascular necrosis (AVN). Eight samples were Durom (Zimmer, Indiana, USA) devices and six were Articular Surface Replacements (ASR, DePuy, Leeds, United Kingdom). One AVN retrieval was a Durom, the other an ASR. The mean time to fracture was 3.4 months. The AVNs were retrieved after 16 months (Durom) and 38 months (ASR). Volumetric wear rates were determined using a Mitutoyo Legex 322 co-ordinate measuring machine (scanning accuracy within 1 micron) and a bespoke computer program. The method was validated against gravimetric calculations for volumetric wear using a sample femoral head that was artificially worn in vitro. At 5mm3, 10mm3, and 15mm3 of material removal, the method was accurate to within 0.5mm3. Surface roughness data was collected using a Zygo NewView500 interferometer (resolution 1nm). Mean wear rates of 17.74mm3/year were measured from the fracture components. Wear rates for the AVN retrievals were 0.43mm3/year and 3.45mm3/year. Mean roughness values of the fracture retrievals (PV = 0.754nm, RMS = 0.027nm) were similar to the AVNs (PV = 0.621nm, RMS = 0.030nm), though the AVNs had been in vivo for significantly longer. Theoretical lubrication calculations were carried out which found that in both AVN retrievals and in seven of the twelve cases of femoral fracture the roughening was sufficient to change the lubrication regime from fluid film to mixed. Three of these surfaces were bordering on the boundary lubrication regime. The results show that even before the femoral fracture, wear rates and roughness values were high and the implants were performing poorly.
Abstract. Introduction. In general the life expectancy of population is improving. This is causing to increase case load of peri-prosthesis fractures after joint replacements. We present our results of peri-prosthesis
The Nottingham
The covid-19 pandemic had a great impact in the daily clinical and surgical practice. Concerning patients with a femoral neck fracture, there is the need of a negative Sars-CoV-2 test or an established isolation period for the positive cases, pre-operatively. The goal of this study was to evaluate the impact of the pandemic in the management of patients with femoral neck fractures, who were submitted to surgical treatment with hemiarthroplasty, in our hospital. A retrospective, observational study was performed, analysing the patients with femoral neck
Introduction and Objective. Dislocation of a hip hemiarthroplasty is a significant complication with a high mortality rate in elderly patients. Previous studies have shown a higher risk of dislocation in patients with neuromuscular conditions. In this study, we reviewed our larger cohort of patients to identify if there is a link between neuromuscular disorders and dislocation of hip hemiarthroplasty in patients with neuromuscular conditions. Materials and Methods. We have retrospectively analysed a single-centre data that was collected over 34 years for patients with intracapsular neck of femur
Introduction and Objective. Geriatric patients with a fragility
Introduction. The incidence of distal femoral fractures in the geriatric population is growing and represents the second most common insufficiency fracture of the femur following
Introduction. Long-term use of bisphosphonates has been known to induce femoral insufficiency fracture in osteoporotic patients. We followed patients who had femoral insufficiency fractures after a long-term use of bisphosphonates. Methods. Eleven patients (14 hips) were diagnosed as having an insufficiency fracture of the femur after long-term (> 4 years) use of bisphosphonate to treat osteoporosis between January 2002 and December 2008. All patients were women who had a mean age of 68 years (range, 57 to 82 years). The fracture site was located in the subtrochanteric area in 6 hips and the femoral shaft in 8 hips. Three patients had bilateral involvement. These patients were followed-up for a mean of 27 months (range, 12 to 60 months). Results. Five hips in five patients displaced during the follow-up period. The mean period from the diagnosis of insufficiency fracture to the displacement was 10 months (range, 1 to 19 months). Five hips (five patients) underwent internal fixation due to persistent pain. Thus, during the follow-up of 27 months, operation was necessary in 71% (10 hips) of 14 insufficiency
Exeter Trauma Stem (ETS) is one of the most common implants used for treating displaced intracapsular
Reported rates of dislocation in hip hemiarthroplasty
(HA) for the treatment of intra-capsular
Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic
Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemeted prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic
The calcar femorale or ‘true neck’ of the femur has a role in transmitting load from the cantilevered neck to the femoral shaft (Zhang 2009). It can appear as a distinct condensation in clinical CT images because its structure is very similar to compact bone (Aspden 1998). Harty (1957) proposed that the calcar acts as a ‘spike’ in certain fall situations, contributing to splitting of the trochanter. We hypothesised that among elderly fallers, the size of the calcar would influence whether fractures occurred in the trochanteric (TR) or femoral neck (FN) site. We also asked whether patients who sustained a fracture had more or less calcar bone than frailty-matched controls that fell but didn't fracture. The FEMCO study is designed to investigate male (M) and female (F) patients with acute
We compared joint proprioception in 12 hips in 12 patients with hemiarthroplasty after
Trauma and orthopaedics is the largest of the
surgical specialties and yet attracts a disproportionately small
fraction of available national and international funding for health
research. With the burden of musculoskeletal disease increasing,
high-quality research is required to improve the evidence base for
orthopaedic practice. Using the current research landscape in the
United Kingdom as an example, but also addressing the international
perspective, we highlight the issues surrounding poor levels of
research funding in trauma and orthopaedics and indicate avenues
for improving the impact and success of surgical musculoskeletal
research. Cite this article:
This study aims to assess the correlation of CT-based structural
rigidity analysis with mechanically determined axial rigidity in
normal and metabolically diseased rat bone. A total of 30 rats were divided equally into normal, ovariectomized,
and partially nephrectomized groups. Cortical and trabecular bone
segments from each animal underwent micro-CT to assess their average
and minimum axial rigidities using structural rigidity analysis.
Following imaging, all specimens were subjected to uniaxial compression
and assessment of mechanically-derived axial rigidity.Objectives
Methods
To assess the sensitivity and specificity of self-reported osteoporosis
compared with dual energy X-ray absorptiometry (DXA) defined osteoporosis,
and to describe medication use among participants with the condition. Data were obtained from a population-based longitudinal study
and assessed for the prevalence of osteoporosis, falls, fractures
and medication use. DXA scans were also undertaken.Objectives
Methods
We investigated several factors which affect the stability of cortical screws in osteoporotic bone using 18 femora from cadavers of women aged between 45 and 96 years (mean 76). We performed bone densitometry to measure the bone mineral density of the cortical and cancellous bone of the shaft and head of the femur, respectively. The thickness and overall bone mass of the cortical layer of the shaft of the femur were measured using a microCT scanner. The force required to pull-out a 3.5 mm titanium cortical bone screw was determined after standardised insertion into specimens of the cortex of the femoral shaft. A significant correlation was found between the pull-out strength and the overall bone mass of the cortical layer (r2 = 0.867, p <
0.01) and also between its thickness (r2 = 0.826, p <
0.01) and bone mineral density (r2 = 0.861, p <
0.01). There was no statistically significant correlation between the age of the donor and the pull-out force (p = 0.246), the cortical thickness (p = 0.199), the bone mineral density (p = 0.697) or the level of osteoporosis (p = 0.378). We conclude that the overall bone mass, the thickness and the bone mineral density of the cortical layer, are the main factors which affect the stability of a screw in human female osteoporotic cortical bone.
Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three-dimensional computer model was designed to simulate impingement and used to examine 125 combinations of positioning of the components in order to allow maximum movement without impingement. Increase in acetabular and/or femoral anteversion allowed greater internal rotation before impingement occurred, but decreases the amount of external rotation. A decrease in abduction of the acetabular components increased internal rotation while decreasing external rotation. Although some correction for malposition was allowable on the opposite side of the joint, extreme degrees could not be corrected because of bony impingement. We introduce the concept of combined component position, in which anteversion and abduction of the acetabular component, along with femoral anteversion, are all defined as critical elements for stability.