Advertisement for orthosearch.org.uk
Results 1 - 20 of over 10000
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 16 - 19
1 Oct 2015
Oussedik S Abdel MP Cross MB Haddad FS

Many aspects of total knee arthroplasty have changed since its inception. Modern prosthetic design, better fixation techniques, improved polyethylene wear characteristics and rehabilitation, have all contributed to a large change in revision rates. Arthroplasty patients now expect longevity of their prostheses and demand functional improvement to match. This has led to a re-examination of the long-held belief that mechanical alignment is instrumental to a successful outcome and a focus on restoring healthy joint kinematics. A combination of kinematic restoration and uncemented, adaptable fixation may hold the key to future advances. Cite this article: Bone Joint J 2015;97-B(10 Suppl A):16–19


Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. Discussion. There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures. Cite this article: Bone Jt Open 2023;4(1):27–37


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1428 - 1434
1 Oct 2015
Clement ND Vats A Duckworth AD Gaston MS Murray AW

Controversy remains whether the contralateral hip should be fixed in patients presenting with unilateral slipped capital femoral epiphysis (SCFE). This retrospective study compares the outcomes and cost of those patients who had prophylactic fixation with those who did not. Between January 2000 and December 2010 a total of 50 patients underwent unilateral fixation and 36 had prophylactic fixation of the contralateral hip. There were 54 males and 32 females with a mean age of 12.3 years (9 to 16). The rate of a subsequent slip without prophylactic fixation was 46%. The risk of complications was greater, the generic health measures (Short Form-12 physical (p < 0.001) and mental (p = 0.004) summary scores) were worse. Radiographic cam lesions in patients presenting with unilateral SCFE were only seen in patients who did not have prophylactic fixation. Furthermore, prophylactic fixation of the contralateral hip was found to be a cost-effective procedure, with a cost per quality adjusted life year gained of £1431 at the time of last follow-up. . Prophylactic fixation of the contralateral hip is a cost-effective operation that limits the morbidity from the complications of a further slip, and the diminished functional outcome associated with unilateral fixation. . Cite this article: Bone Joint J 2015;97-B:1428–34


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 55 - 55
11 Apr 2023
Raina D Markeviciute V Arvidsson L Törnquist E Stravinskas M Kok J Jacobson I Liu Y Tengattini A Sezgin E Vater C Zwingenberger S Isaksson H Tägil M Tarasevicius S Lidgren L
Full Access

Majority of osteoporosis related fractures are treated surgically using metallic fixation devices. Anchorage of fixation devices is sometimes challenging due to poor osteoporotic bone quality that can lead to failure of the fracture fixation. Using a rat osteoporosis model, we employed neutron tomography and histology to study the biological effects of implant augmentation using an isothermally setting calcium sulphate/hydroxyapatite (CaS/HA) biomaterial with synthetic HA particles as recruiting moiety for systemically administered bisphosphonates. Using an osteoporotic sawbones model, we then provide a standardized method for the delivery of the CaS/HA biomaterial at the bone-implant interface for improved mechanical anchorage of a lag-screw commonly used for hip fracture fixation. As a proof-of-concept, the method was then verified in donated femoral heads and in patients with osteoporosis undergoing hip fracture fixation. We show that placing HA particles around a stainless-steel screw in-vivo, systemically administered bisphosphonates could be targeted towards the implant, yielding significantly higher peri-implant bone formation compared to un-augmented controls. In the sawbones model, CaS/HA based lag-screw augmentation led to significant increase (up to 4 times) in peak extraction force with CaS/HA performing at par with PMMA. Micro-CT imaging of the CaS/HA augmented lag-screws in cadaver femoral heads verified that the entire length of the lag-screw threads and the surrounding bone was covered with the CaS/HA material. X-ray images from fracture fixation surgery indicated that the CaS/HA material could be applied at the lag-screw-bone interface without exerting any additional pressure or risk of venous vascular leakage.: We present a new method for augmentation of lag-screws in fragile bone. It is envisaged that this methodcould potentially reduce the risk of fracture fixation failure especially when HA seeking “bone active” drugs are used systemically


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 992 - 996
1 Jul 2015
Parker MJ

A total of 56 male patients with a displaced intracapsular fracture of the hip and a mean age of 81 years (62 to 94), were randomised to be treated with either a cemented hemiarthroplasty (the Exeter Trauma Stem) or reduction and internal fixation using the Targon Femoral Plate. All surviving patients were reviewed one year after the injury, at which time restoration of function and pain in the hip was assessed. There was no statistically significant difference in mortality between the two groups (7/26; 26.9% for hemiarthroplasty vs 10/30; 33.3% for internal fixation). No patient treated with a hemiarthroplasty required further surgery, but eight patients treated by internal fixation did (p = 0.005), five requiring hemiarthroplasty and three requiring total hip arthroplasty. Those treated by internal fixation had significantly more pain (p = 0.02). The restoration of mobility and independence were similar in the two groups. These results indicate that cemented hemiarthroplasty gives better results than internal fixation in elderly men with a displaced intracapsular fracture of the hip. Cite this article: Bone Joint J 2015;97-B:992–6


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 49 - 49
1 Jun 2023
Thompson E Shamoon S Qureshi A
Full Access

Introduction. Circular external fixators are fundamental to lower limb reconstruction, primarily in situations with a high risk of infection such as open fractures. During the Covid-19 pandemic, use of circular frames in our unit decreased, following departmental approval, due to resource management and in keeping with BOA guidelines as we opted to “consider alternative techniques for patients who require soft tissue reconstruction to avoid multiple operations”. These alternatives included the use of internal fixation (plate osteosynthesis and intramedullary nailing) as a measure to reduce the number of hospital attendances for patients and to conserve resources. This change in practice has continued in part following the pandemic with the increased use of internal fixation in cases previously deemed unsuitable for such techniques. We present our experience of this treatment strategy in the management of complex lower limb injuries, focusing on outcomes and consider the lessons learnt. Materials & Methods. Data of patients with complex lower limb injuries treated before, during and after the pandemic were collected from our in-house trauma database, theatre records and follow up clinics. The rationale for choosing other techniques over a circular frame, the type of alternative technique used, the cost of such alternatives, the need for soft tissue reconstruction, time to recovery, complications and amputation rates were compared among groups. Results. These data suggest comparable outcomes between circular frames and alternative techniques can be achieved. A notable reduction in the number of circular frames applied during the review period was observed. Furthermore, frame fixation was associated with more frequent outpatient review and the associated implications for resource management. Conclusions. Conclusion: The Covid-19 pandemic has posed great challenges to the Trauma and Orthopaedic community, forcing us to be flexible by adopting alternative treatment methods to traditional circular external fixation. These alternatives have proven feasible and potentially more cost effective, prompting their adoption in the post pandemic era. However, this change of practice is not without potential consequences and continued investigation is warranted


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 14 - 14
10 May 2024
Mooya S Berney M Cleary M Rowan F
Full Access

Introduction. The condition of the soft tissues surrounding an ankle fracture influences timing and treatment of injuries. Conventional treatment used an open approach to facilitate anatomical reduction and rigid internal fixation. Intramedullary devices for fibular fractures provide a safe alternative in patients in which the condition of the soft tissue envelope or the patient's co-morbidities may benefit from a less invasive approach. We compared outcomes for patients treated with open reduction internal fixation (ORIF) with those undergoing treatment with fibular nails (FN). Methods. 13 consecutive patients treated with fibular nails (FN) were compared with 13 age-matched patients that underwent open reduction and internal fixation (ORIF). All patients were followed to union. Study outcomes were time from admission to surgery, length of stay, wound failure, implant failure, revision surgery, OMAS and SF-36. Results. There was no difference in age or sex distribution between groups. There was no difference in OMAS at 1 year (83 ± 9 in FN group; 80± 21 in ORIF group) and SF-36 (94 ± 11 and 90 ± 20). There were 2 implant failures in the ORIF group and none in the FN group. There was one wound failure in the ORIF group and none in the FN group. Patients treated with FN had a shorter time to surgery (1 day ± 24 hours vs 3 days ± 24 hours) and shorter length of stay (1 day ± 24 hours vs 4 days ± 96 hours). Conclusion. FN is a safe method to treat patients with displaced distal fibular fractures that may have a poor soft tissue envelope and risk factors for wound healing. FN reduces the time to surgery and overall length of stay compared with similar patients treated with conventional ORIF


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 2 - 2
10 Oct 2023
Heinz N Bugler K Clement N Low X Duckworth A White T
Full Access

To compare the long-term outcomes of fibular nailing and plate fixation for unstable ankle fractures in a cohort of patients under the age of 65 years. Patients from a previously conducted randomized control trial comparing fibular nailing and plate fixation were contacted at a minimum of 10 years post intervention at a single study centre. Short term data were collected prospectively and long-term data were collected retrospectively using an electronic patient record software. Ninety-nine patients from one trauma centre were included (48 fibular nails and 51 plate fixations). Groups were matched for gender (p = 0.579), age (p = 0.811), body mass index (BMI)(p = 0.925), smoking status (p = 0.209), alcohol status (p = 0.679) and injury type (p = 0.674). Radiographically at an average of 2 years post-injury, there was no statistically significant difference between groups for development of osteoarthritis (p = 0.851). Both groups had 1 tibio-talar fusion (2% of both groups) secondary to osteoarthritis with no statistically significant difference in overall re-operation rate between groups identified (p = 0.518,). Forty-five percent (n=42) of patients had so far returned patient reported outcome measures at a minimum of 10 years (Fibular nail n=19, plate fixation n=23). No significant difference was found between groups at 10 years for the Olerud and Molander Ankle Score (p = 0.990), the Manchester-Oxford Foot Questionnaire (p = 0.288), Euroqol-5D Index (p = 0.828) and Euroqol-5D Visual Analogue Score (p = 0.769). The current study illustrates no difference between fibular nail fixation and plate fixation at a long-term follow up of 10 years in patients under 65 years old, although the study is currently under powered


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 185 - 191
1 Feb 2015
Kendrick BJL Kaptein BL Valstar ER Gill HS Jackson WFM Dodd CAF Price AJ Murray DW

The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs. . A total of 43 patients were randomised to receive either a cemented or a cementless Oxford UKA and were followed for two years with radiostereometric analysis (RSA), radiographs aligned with the bone–implant interfaces and clinical scores. The femoral components migrated significantly during the first year (mean 0.2 mm) but not during the second. There was no significant difference in the extent of migration between cemented and cementless femoral components in either the first or the second year. In the first year the cementless tibial components subsided significantly more than the cemented components (mean 0.28 mm (. sd. 0.17) vs. 0.09 mm (. sd. 0.19 mm)). In the second year, although there was a small amount of subsidence (mean 0.05 mm) there was no significant difference (p = 0.92) between cemented and cementless tibial components. There were no femoral radiolucencies. Tibial radiolucencies were narrow (< 1 mm) and were significantly (p = 0.02) less common with cementless (6 of 21) than cemented (13 of 21) components at two years. There were no complete radiolucencies with cementless components, whereas five of 21 (24%) cemented components had complete radiolucencies. The clinical scores at two years were not significantly different (p = 0.20). . As second-year migration is predictive of subsequent loosening, and as radiolucency is suggestive of reduced implant–bone contact, these data suggest that fixation of the cementless components is at least as good as, if not better than, that of cemented devices. Cite this article: Bone Joint J 2015; 97-B:185–91


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 2 - 2
17 Jun 2024
Fishley W Morrison R Baldock T Hilley A Baker P Townshend D
Full Access

Background. In fixation of the fibula in ankle fractures, AO advocate using a lag screw and one-third tubular neutralisation plate for simple patterns. Where a lag screw cannot be placed, bridging fixation is required. A local pilot service evaluation previously identified variance in use of locking plates in all patterns with significant cost implications. The FAIR study aimed to evaluate current practice and implant use across the United Kingdom (UK) and review outcomes and complication rates between different fibula fixation methods. Method. The study was supported by CORNET, the North East trainee research collaborative, and BOTA. Data was collected using REDCap from 22 centres in the UK retrospectively for a one-year period between 1. st. January 2019 and 31. st. December 2019 on injury mechanism, fracture characteristics, comorbidities, fixation and complications. Follow-up data was collected to at least two-years from the time surgery. Results. 1448 ankle fractures which involved fixation of the fibula were recorded; one-third tubular plate was used in 866 (59.8%) cases, a locking plate in 463 (32.0%) cases and other methods in 119 (8.2%) cases. There was significant difference between centres (p<0.001) in implant type used. Other factors associated with implant type were age, diabetes, osteoporosis, open fractures, fracture pattern and the presence of comminution. Incidence of lateral wound breakdown was higher in locking plates than one-third tubular plates (p<0.05). There was no significant difference in infection, non-union, fixation failure or removal of metalware. Conclusion. There is significant variation in practice in the UK in implant use for fixation of the fibula in ankle fractures. Potentially unnecessary use of locking plates, where a one-third tubular shows equivalent outcomes, incurs additional cost and may increase the risk of lateral wound breakdown. We would encourage surgeons with high locking plate usage to evaluate their own unit's practice against this data


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded. The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively. We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture


Abstract. Introduction. Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Methodology. Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS). Results. Preliminary analysis of Maximum Total Point Motion (MTPM) indicated cementless tibial components undergo significantly more migration than cemented components during the first 6 months (1.6mm/year, SD=0.92 versus 1.3mm/year, SD=1.1, p<0.001). Cementless migration was predominantly subsidence inferiorly (Mean=0.51mm/year, SD=0.29, p<0.001) and posteriorly (0.13mm/year, SD=0.21, p=0.03). Contrastingly, from 6 months to 10 years cemented components migrated significantly (MTPM=0.039mm/year, SD=0.11, p=0.04) whereas cementless components did not (MTPM=0.002mm/year, SD=0.02, p=0.744). Radiolucent lines occurred more frequently below cemented (10/13) than cementless (4/16) tibial components, but radiolucencies did not correlate with differences in migration or OKS. There was no significant difference in OKS between cemented and cementless. Conclusion. These results suggest that cementless tibial components migrate more than cemented before achieving primary fixation. However, long-term fixation of cementless tibial components appears to be as good, if not better, than cemented with the benefit of fewer radiolucent lines


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 65 - 74
1 Jan 2016
Phadnis J Huang T Watts A Krishnan J Bain GI

Aims. To date, there is insufficient evidence available to compare the outcome of cemented and uncemented fixation of the humeral stem in reverse shoulder arthroplasty (RSA). . Methods. A systemic review comprising 41 clinical studies was performed to compare the functional outcome and rate of complications of cemented and uncemented stems in RSA. These included 1455 cemented and 329 uncemented shoulders. The clinical characteristics of the two groups were similar. Variables were compared using pooled frequency-weighted means and relative risk ratios (RR). Results. Uncemented stems had a significantly higher incidence of early humeral stem migration (p < 0.001, RR 18.1, 95% confidence interval (CI) 5.0 to 65.2) and non-progressive radiolucent lines (p < 0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence of post-operative fractures of the acromion compared with cemented stems (p = 0.004, RR 14.3, 95% CI 0.9 to 232.8). There was no difference in the risk of stem loosening or revision between the groups. The cemented stems had a greater relative risk of infection (RR 3.3, 95% CI 0.8 to 13.7), nerve injury (RR 5.7, 95% CI 0.7 to 41.5) and thromboembolism (RR 3.9, 95% CI 0.2 to 66.6). The functional outcome and range of movement were equivalent in the two groups. . Discussion. RSA performed with an uncemented stem gives them equivalent functional outcome and a better complication profile than with a cemented stem. The natural history and clinical relevance of early stem migration and radiolucent lines found with uncemented stems requires further long-term study. Take home message: This study demonstrates that uncemented stems have at least equivalent clinical and radiographic outcomes compared with cemented stems when used for reverse total shoulder arthroplasty. . Cite this article: Bone Joint J 2016;98-B:65–74


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 58 - 58
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

The optimal method of tibial fixation when using a hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction is unclear. This study aimed to compare the risk of revision ACL reconstruction between suspensory and interference devices on the tibial side. Prospective data on primary ACL reconstructions recorded in the New Zealand ACL Registry between April 2014 and December 2019 were analyzed. Only patients with a hamstring tendon autograft fixed with a suspensory device on the femoral side were included. The rate of revision ACL reconstruction was compared between suspensory and interference devices on the tibial side. Univariate Chi-Square test and multivariate Cox regression was performed to compute hazard ratios (HR) and 95% confidence intervals (CI) with adjustment for age, gender, time-to-surgery, activity at the time of injury, number of graft strands and graft diameter. 6145 cases were analyzed, of which 59.6% were fixed with a suspensory device on the tibial side (n = 3662), 17.6% fixed with an interference screw with a sheath (n = 1079) and 22.8% fixed with an interference screw without a sheath (n = 1404). When compared to suspensory devices (revision rate = 3.4%), a higher risk of revision was observed when using an interference screw with a sheath (revision rate = 6.2%, adjusted HR = 2.05, 95% CI 1.20 – 3.52, p = 0.009) and without a sheath (revision rate = 4.6%, adjusted HR = 1.81, 95% CI 1.02 – 3.23, p = 0.044). The number of graft strands and a graft diameter of ≥8 mm did not influence the risk of revision. When reconstructing the ACL with a hamstring tendon autograft, the use of an interference screw, with or without a sheath, on the tibial side has a higher risk of revision when compared to a suspensory device


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims. Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures. Methods. The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed. Results. A total of 19 studies were included in the qualitative synthesis, and six comparative studies were included in the meta-analysis. Overall, 120 patients received locking-plate fixation with bone-graft augmentation, 179 patients received locking-plate fixation with cement augmentation, and 336 patients received locking-plate fixation without augmentation. No statistically relevant differences between the augmented and non-augmented cohorts were found in terms of the Disabilities of the Arm, Shoulder and Hand questionnaire score and Constant-Murley Score. The cement-augmented group had a significantly lower rate of complications compared to the non-augmented group. Conclusion. While locking-plate fixation with cement augmentation appears to produce a lower complication rate compared to locking-plate fixation alone, functional outcomes seem comparable between augmented and non-augmented techniques. Cite this article: Bone Joint J 2024;106-B(7):646–655


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 38 - 38
23 Feb 2023
Ernstbrunner L Almond M Rupasinghe H Jo O Zbeda R Ackland D Ek E
Full Access

The extracortical single-button (SB) inlay repair is one of the most preferred distal biceps tendon repair techniques. However, specific complications such as neurovascular injury and non-anatomic repairs have led to the development of techniques that utilize intracortical double-button (DB) fixation. To compare the biomechanical stability of the extracortical SB repair with the anatomical DB repair technique. Controlled laboratory study. The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SBor anatomical DB group. Both groups were cyclically loaded with 60N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap-formation and construct stiffness during cyclic loading, and ultimate load to failure was analysed. After 1000 cycles, the anatomical DB technique compared with the extracortical SB technique showed significantly less gap-formation (mean difference 1.2 mm; p=0.017) and significantly more construct stiffness (mean difference 31 N/mm; p=0.023). Ultimate load to failure was not significantly different comparing both groups (SB, 277 N ±92 vs. DB, 285 N ±135; p=0.859). The failure mode in the anatomical DB group was significantly different compared with the extracortical SB technique (p=0.002) and was due to fracture avulsion of the BicepsButton in 7 out of 9 specimens (vs. none in SB group). Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to the SB technique. The DB repair technique reduces the risk of nerve injury and better restores the anatomical footprint of biceps tendon. The DB technique may offer a clinically viable alternative to the SB repair technique


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims. Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods. Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system. Results. At a mean follow-up of 90 months (64 to 130), only two out of 245 cases failed due to aseptic loosening. Intraoperative grading yielded mean scores of 1.87 (95% confidence interval (CI) 1.82 to 1.92) for the femur and 1.96 (95% CI 1.92 to 2.0) for the tibia. Only 3.7% of femoral and 1.7% of tibial reconstructions fell below the 1.5-point threshold, which included the two cases of aseptic loosening. Interobserver reliability for postoperative radiological grading was 0.97 for the femur and 0.85 for the tibia. Conclusion. A minimum score of 1.5 points for each skeletal segment appears to be a reasonable cut-off to define sufficient fixation in rTKA. There were no revisions for aseptic loosening at mid-term follow-up when this fixation threshold was achieved or exceeded. When assessing first-time revisions, this novel grading system has shown excellent intra- and interobserver reliability. Cite this article: Bone Joint J 2024;106-B(5):468–474


Bone & Joint Research
Vol. 13, Issue 10 | Pages 559 - 572
8 Oct 2024
Wu W Zhao Z Wang Y Liu M Zhu G Li L

Aims. This study aimed to demonstrate the promoting effect of elastic fixation on fracture, and further explore its mechanism at the gene and protein expression levels. Methods. A closed tibial fracture model was established using 12 male Japanese white rabbits, and divided into elastic and stiff fixation groups based on different fixation methods. Two weeks after the operation, a radiograph and pathological examination of callus tissue were used to evaluate fracture healing. Then, the differentially expressed proteins (DEPs) were examined in the callus using proteomics. Finally, in vitro cell experiments were conducted to investigate hub proteins involved in this process. Results. Mean callus volume was larger in the elastic fixation group (1,755 mm. 3. (standard error of the mean (SEM) 297)) than in the stiff fixation group (258 mm. 3. (SEM 65)). Pathological observation found that the expression levels of osterix (OSX), collagen, type I, alpha 1 (COL1α1), and alkaline phosphatase (ALP) in the callus of the elastic fixation group were higher than those of the stiff fixation group. The protein sequence of the callus revealed 199 DEPs, 124 of which were highly expressed in the elastic fixation group. In the in vitro study, it was observed that a stress of 200 g led to upregulation of thrombospondin 1 (THBS1) and osteoglycin (OGN) expression in bone marrow mesenchymal stem cells (BMSCs). Additionally, these genes were found to be upregulated during the osteogenic differentiation process of the BMSCs. Conclusion. Elastic fixation can promote fracture healing and osteoblast differentiation in callus, and the ability of elastic fixation to promote osteogenic differentiation of BMSCs may be achieved by upregulating genes such as THBS1 and OGN. Cite this article: Bone Joint Res 2024;13(10):559–572


Bone & Joint Open
Vol. 3, Issue 7 | Pages 566 - 572
18 Jul 2022
Oliver WM Molyneux SG White TO Clement ND Duckworth AD

Aims. The primary aim was to estimate the cost-effectiveness of routine operative fixation for all patients with humeral shaft fractures. The secondary aim was to estimate the health economic implications of using a Radiographic Union Score for HUmeral fractures (RUSHU) of < 8 to facilitate selective fixation for patients at risk of nonunion. Methods. From 2008 to 2017, 215 patients (mean age 57 yrs (17 to 18), 61% female (n = 130/215)) with a nonoperatively managed humeral diaphyseal fracture were retrospectively identified. Union was achieved in 77% (n = 165/215) after initial nonoperative management, with 23% (n = 50/215) uniting after surgery for nonunion. The EuroQol five-dimension three-level health index (EQ-5D-3L) was obtained via postal survey. Multiple regression was used to determine the independent influence of patient, injury, and management factors upon the EQ-5D-3L. An incremental cost-effectiveness ratio (ICER) of < £20,000 per quality-adjusted life-year (QALY) gained was considered cost-effective. Results. At a mean of 5.4 yrs (1.2 to 11.0), the mean EQ-5D-3L was 0.736 (95% confidence interval (CI) 0.697 to 0.775). Adjusted analysis demonstrated the EQ-5D-3L was inferior among patients who united after nonunion surgery (β = 0.103; p = 0.032). Offering routine fixation to all patients to reduce the rate of nonunion would be associated with increased treatment costs of £1,542/patient, but would confer a potential EQ-5D-3L benefit of 0.120/patient over the study period. The ICER of routine fixation was £12,850/QALY gained. Selective fixation based on a RUSHU < 8 at six weeks post-injury would be associated with reduced treatment costs (£415/patient), and would confer a potential EQ-5D-3L benefit of 0.335 per ‘at-risk patient’. Conclusion. Routine fixation for patients with humeral shaft fractures to reduce the rate of nonunion observed after nonoperative management appears to be a cost-effective intervention at five years post-injury. Selective fixation for patients at risk of nonunion based on their RUSHU may confer even greater cost-effectiveness, given the potential savings and improvement in health-related quality of life. Cite this article: Bone Jt Open 2022;3(7):566–572


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 8 - 8
10 Jun 2024
Airey G Aamir J Chapman J Tanaka H Elbannan M Singh A Mangwani J Kyaw H Jeyaseelan L Mason L
Full Access

Background. Research on midfoot injuries have primarily concentrated on the central column and the Lisfranc ligament without amassing evidence on lateral column injuries. Lateral column injuries have historically been treated with Kirschner wire fixation when encountered. Objective. Our aim in this study was to analyse lateral column injuries to the midfoot, their method of treatment and the radiological lateral column outcomes. Our nul hypothesis being that fixation is required to obtain and maintain lateral column alignment. Methods. Data was retrospectively collected from four centres on surgically treated midfoot fracture dislocations between 2011 and 2021. Radiographs were analysed using departmental PACS. All statistics was performed using SPSS 26. Results. A total of 235 cases were diagnosed as having a lateral column injury out of the 409 cases included. On cross tabulation, there was a significant association with having a central column injury (234/235, p<.001) and 70% of cases (166/235) also had an additional medial column injury. Of the 235 lateral column injuries, data was available regarding fixation radiographic alignment on 222 cases. There were 44 cases which underwent Kirschner wire fixation, 23 plate fixations and 3 screw fixations. Lateral column alignment loss was seen in 2.84% (4/141) of those which didn't undergo fixation, 13.64% (6/44) which underwent K wires, and 0 % in those fixed by screws or K wires. Conclusion. Lateral column injury occurs in over half of midfoot fractures in this study. It rarely occurs alone and is most commonly related to three column injuries. Nevertheless, following stabilisation of the central column, additional fixation of injuries to the lateral column do not appear beneficial. The use of a bridge plate to fix the central column appears protective and purely ligamentous injury was a higher risk than an injury that included the bone