A prospective, randomized, controlled trial was performed to compare the outcome of treatment of unstable fractures of the proximal part of the femur with either a sliding hip screw or a short proximal
Purpose. To perform comparative analysis between the results of internal fixation using proximal
Introduction. Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal
The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.Aims
Methods
Pertrochanteric femoral fractures are common and intramedullary nailing with a proximal
The PFNA is used routinely at the RUH for unstable peri-trochanteric and femoral fractures. Failure of operative treatment is associated with increased morbidity and financial burden. We analysed surgical and fracture factors, aiming to identify those associated with fixation failure. Retrospective analysis of 76 consecutive patients treated with a PFNA between 2009–2012 was performed. Patient demographics were assessed, along with fracture classification, adequacy of reduction, tip apex distance (TAD) and grade of surgeon. Failure was defined as metal work failure, non-union or need for repeat procedure. The mean age was 78.9 years (25.9–97.4). 21 were male and 49 female. There were 17 failures (24.3%) (7 required further surgery). 10 failures were per-trochanteric, 2 sub-trochanteric and 5 mid-shaft fractures. Complications included 4 broken and 6 backed-out distal locking screws, 2 blade cut-outs, 1 nail fracture and 4 non-unions. All per-trochanteric were adequately reduced with a TAD <25 mm. 11/17 had consultant supervision. A high rate of backed-out distal locking screws was identified. We found no concerns with adequacy of reduction, TAD or consultant supervision.
In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty(BH), compression hip screw(CHS) and proximal femur nail antirotatory(PFNA) in treating comminuted intertrochanteric fractures(AO type, A2(21, 22, 23)) We retrospectively evaluated total 150 patients(BH:50, CHS:50, PFNA: 50) who were operated due to intertrochanteric fractures from March 2010 to Dec 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris hip score, ability of ambulation(Koval stage), visual analogue scale and radiologic limb length discrepancy(shortening). Landmark and radiologic length was checked.
–A: postoperative length –A’: POD 1year –B: immediate posteopative contralateral length(from hip center to distal tip of lesser trochanter) –B’: POD 1year contralateral length(from hip center to distal tip of lesser trochanter) –
Limb length(shortening) was adjusted considering difference of magnification = {A × (B’/B)}− A’Introduction
Materials and Methods
Long
In the polytrauma patient, intraoperative patient positioning is one factor thought to influence pulmonary complications associated with intramedullary (IM) nailing of the femur. With regards to lateral
This technique is a novel superior based muscle sparing approach. Acetabular reaming in all hip approaches requires femoral retraction. This technique is performed through a hole in the lateral femoral cortex without the need to retract the femur. A 5 mm hole is drilled in the lateral femur using a jig attached to the broach handle, similar to a
Introduction. The aim of this radiographic study was to define the anatomical axis joint centre distance (aJCD) and anatomical axis joint centre ratio (aJCR) of the distal femur in the coronal plane for skeletally mature individuals. Materials and Methods. A cross-sectional radiographic study was conducted to calculate the horizontal distances between the anatomical axis and the centre of the knee at the level of the intercondylar notch and the joint line. Ratios relating these points to the width of the femur were then calculated. Results. A total of 164 radiographs were included: 91 male (55.5%) and 73 female patients (44.5%) with a mean age of 44.9 ± 18.0 years, with 79 right (48.2%) and 85 left (51.8%). The intercondylar width mean was 75.4 ± 6.8mm, the median aJCD at the notch was 3.6mm (interquartile range, IQR 2.1 – 5.1), the median aJCD at the joint line was 4.7mm (IQR 3.5 – 6.3), the aJCR at the notch 45.1 ± 2.7, and the aJCR at the joint line 43.5 ± 2.7. The intercondylar width was significantly different (p<0.001) between males (79.5 ± 5.0 mm) and females (70.4 ± 5.1 mm). A significant difference between the aJCR at the notch (p=0.003) and the aJCR at the joint line (p=0.002) was observed in males and females. No differences between the aJCD at the notch or aJCD at the joint line was observed between males versus females, left versus right and those younger versus those older than 65 years. Conclusions. This is the first objective description of the anatomic axis joint centre ratio (aJCR) of the distal femur in the coronal plane. This ratio can be used to aid the planning and execution of distal femoral deformity correction, retrograde
Introduction. At Sheffield Children's Hospital, treatment of leg length discrepancy is a common procedure. Historically, this has been done with external fixators. With the development in intramedullary technology, internal nails have become the preferred modality for long bone lengthening in the adolescent population. However, it is important to review whether this technology practically reduces the known challenges seen and if it brings any new issues. Therefore, the aim of this review is to retrospectively evaluate the therapeutic challenges of 16 fit-bone intramedullary femoral lengthening's at Sheffield Children's Hospital between 2021–2022. Materials & Methods. The international classification of function (ICF) framework was used to differentiate outcomes. The patient's therapy notes were retrospectively reviewed for themes around structural, activity and participation limitation. The findings were grouped for analysis and the main themes presented. Results. There were 8 males, mean age 17.4 years (range 17–18) and 8 females, mean age 15.9 years (range 14–18). 5 right and 11 left femurs were lengthened. Underlying pathology varied amongst the 16 patients. All patients went into a hinged knee brace post operatively. Structural limitations included: pain, fixed flexion deformity of the knee, loss of knee flexion, quadriceps muscle lag, muscle spasms and gluteal weakness. The primary activity limitation was reduced weight bearing with altered gait pattern. Participation limitations included reduced school attendance and involvement in activities with peers. Access to Physiotherapy from local services varied dramatically. Five of the cohort have completed treatment. Conclusions. Anecdotally, intramedullary
Introduction. Pixel Value Ratio (PVR) is a radiographic measure of the relative density of the regenerate to the adjacent bone. This has been reported as an objective criterion for regenerate healing and a guide for when to allow full weight bearing (FWB) in lengthening with intramedullary telescopic nails. The threshold for which magnitude of PVR is adequate to allow bearing full weight is not yet agreed. The aim of this study was to identify from our cohort of adult limb lengthening patients the time to FWB following lengthening, the PVR at this point, and how this compared with the recommended values in the literature. Materials and Methods. A retrospective database review identified 30 adult patients treated with the PRECICE
Purpose. To compare the clinical and radiological results between internal fixation using the proximal
The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines.Aims
Methods
Introduction. The incidence of distal femoral fractures amongst elderly patients is likely to rise due to increased life expectancy. This study reports on the outcome of a series of distal femoral fractures treated by retrograde
Purpose. The timing of definitive fixation for major fractures in polytrauma patients is controversial. To clarify this aspect of trauma management, we randomised patients with blunt multiple injuries to either initial definitive stabilisation of the femur shaft with an intramedullary nail or an external fixator which was converted to an intramedullary nail at a secondary procedure and documented the post-operative clinical condition. Methods. Multiply injured patients with femoral shaft fractures were randomised to either initial (<24 hours) intramedullary
Proximal
In patients requiring two-stage procedures, stabilization of large skeletal defects after radical debridement must be attained in order to successfully treat the infection. With the use of standard rod plus antibiotic impregnated PMMA spacers limb salvage may be attempted with satisfactory results. Between 1992 and 2014, 23 patients were treated for hip, knee, or shoulder musculoskeletal infections resulting in an average skeletal defect of 22 cm. There were 13 males and 10 females. Twelve patients had infected tumor prostheses, seven patients had an infected total joint arthroplasty, and four patients had a primary infection involving a large skeletal defect. The mean time from the index procedure until infection was 22 months. Following debridement, the defect was stabilized with Tobramycin and Vancomycin impregnated PMMA and intramedullary nails. Patients were treated with IV and oral antibiotics for six weeks each. In 18 patients who had resection about the knee stabilization was achieved with a single femoral or tibial nail in nine patients and with two nails joined by a screw or cerclage wire in the other nine. In four patients a cephalomedullary
Introduction. The project of a modular, double-conicity stem is born from the need to obtain primary stability and correct osseointegration in patients with developmental hip dysplasia, or proximal femoral dysmorphisms requiring a femoral shortening osteotomy or presenting characteristics of non-adaptability to single-conicity or straight stems. Such an implant could also be employed in