Abstract
Introduction
Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal Femoral Nail Antirotation (PFNA) is a recently introduced implant from AO/ASIF designed to compact the cancellous bone and may be particularly useful in unstable and osteoporotic hip fractures. This study is a single and independent centre experience of this implant used in management of acute hip fractures.
Methods
68 patients involving 68 PFNA nailing procedures done over a period of 2 years (2007–09) were included in the study. Average follow-up period of patients was 1 year. AO classification for trochanteric fractures was used to classify all the fractures. Radiological parameters including tip-apex distance and neck shaft angle measurement were assessed.
Results
Average age of patients included in the study was 80 years. 18 patients died during the follow up period due to non-procedure related causes. Average tip-apex distance was 12.7 mm and radiological fracture union time was 5 months. Revision of short to a long PFNA was needed for periprosthetic fracture of shaft of femur in two patients. Two patients needed a complex total hip replacement eventually and further two patients had removal of the implant due to PFNA blade penetration through the femoral head.
Discussion
PFNA is a technically demanding procedure and has a learning curve. Our experience shows that it is a useful implant in unstable pertrochanteric fracture fixation. A close radiological and clinical follow up is recommended due to the risk of late fracture and implant related complications.