Surgical debridement for medial epicondylitis (ME) is indicated for patients with refractory ME. The clinical efficacy of simple debridement has not been studied sufficiently. Moreover, authors experienced surgical outcome of ME was not as good as lateral epicondylitis. In this regard, authors have combined the atelocollagen injection in the debridement surgery of ME. The purpose of study was to compare clinical outcomes between simple debridement and debridement combined with atelocollagen injection in the ME. Twenty-five patients with refractory ME and underwent surgical debridement were included in the study. Group A (n=13) was treated with isolated debridement surgery, and group B (n=12) was treated with debridement combined with 1.0 mL of type I atelocollagen. Pain and functional improvements were assessed using visual analogue scale, Mayo
Driven by increasing emphasis on problem-based and self-directed learning, medical students and doctors in orthopedic specialty training rely increasingly on the internet as learning resource. As students or residents performance on physical examination may be less supervised in comparison to other clinical skills (for example surgical competence), online videos may provide a valuable source for education of physical examination skills. Cognitive psychological research has shown that videos can help viewers to understand techniques and manage the sequential steps of physical examination and approach to patients. YouTube is the largest open-access video platform available and provides access to thousands of educational videos on orthopedics-related topics. VuMedi, G9MD, and Orthobullets are examples of online platforms requiring user-registration with video content that is more directly focused on orthopedic topics. The objective of this study was to investigate the accuracy and quality of instructional videos on the physical examination of the
Advancements in treating the unstable
Introduction. The stability of the
Background. The pattern of appearance of secondary ossification centers in the
Introduction. The epicondylar axis of the
Summary. In contrast to the current literature, myofibroblasts are not present in chronic posttraumatic elbow contractures. However, myofibroblasts are present in the acute phase after an
Primary bony tumours of the
Introduction. Two randomised trials concluded cast type (above or below elbow) makes no significant difference in the re-displacement rate of paediatric forearm fractures involving the distal third of the radius. This has not, however, led to the universal use of below
Increasingly more emphasis is being placed on Patient Reported Outcome Measures (PROMs). There are many used and reported in clinical studies, but there are no universally accepted or preferred measures. It is important for a researcher with a non-clinical background to understand how these assessments are performed, the type of information provided by each of the measures, and which diseases states are best reported by each measure.
Standard fixation for intra-articular distal humerus fracture is open reduction and internal fixation (ORIF). However, high energy fractures of the distal humerus are often accompanied with soft tissue injuries and or vascular injuries which limits the use of internal fixation. In our report, we describe a highly complex distal humerus fracture that showed promising healing via a ring external fixator. A 26-year-old man sustained a Gustillo Anderson Grade IIIB intra-articular distal humerus fracture of the non-dominant limb with bone loss at the lateral column. The injury was managed with aggressive wound debridement and cross
Radial head fractures are among the most common fractures around the
To analyse bone stresses in humerus-megaprosthesis construct in response to axial loading under varying implant lengths in proximal humeral replacement following tumour excision. CT scans of 10 cadaveric humeri were processed in 3D Slicer to obtain three-dimensional (3D) models of the cortical and cancellous bone. Megaprostheses of varying body lengths (L) were modelled in FreeCAD to obtain the 3D geometry. Four FE models: group A consisting of intact bone; groups B (L=40mm), C (L=100mm) and D (L=120mm) comprising of humerus-megaprosthesis constructs were created. Isotropic linear elastic behaviour was assigned for all materials. A tensile load of 200N was applied to the
Abstract. Objectives. Falling studies have been conducted in controlled environments but not in field studies for ethical reasons; this limits the validity and applicability of previous studies. We performed field studies on existing YouTube © videos of skateboarders falling. The aims were to measure the wrist angle at impact on videos of real unprotected falls and to study the dynamics of the upper limbs when falling. Methods. Youtube © videos of skateboarders falling were studied assessing the direction of the fall, the positions of both upper limbs and especially the wrists on impact. This study would not be ethical by other means. Results. In study one (the more quantitative study) there were 48 men and 50 falls. The mean
Olecranon plates used for the internal fixation of complex olecranon fractures are applied directly over the triceps tendon on the posterior aspect of the olecranon. The aim of the study is to describe the relationship of the plates and screws to the triceps tendon at the level of the olecranon. Eight cadaveric
Introduction and Objective. There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. Materials and Methods. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and
Abstract. Introduction. Intra-articular distal humerus OTA type C fractures are challenging to treat. When osteosynthesis is not feasible one can choose to do a primary arthroplasty of
The purpose of this study is to report the clinical and radiological outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. After ethical approval (reference: 17/YH/0318), patients were identified and invited to participate in this observational study. Inclusion criteria included: 1) severe glenoid bone loss necessitating the need for custom implants; 2) patients with definitive glenoid and humeral components implanted more than 2 years prior; 3) ability to comply with patient reported outcome questionnaires. After seeking consent, included patients underwent clinical assessment utilising the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and
Paediatric musculoskeletal (MSK) disorders often produce severe limb deformities, that may require surgical correction. This may be challenging, especially in case of multiplanar, multifocal and/or multilevel deformities. The increasing implementation of novel technologies, such as virtual surgical planning (VSP), computer aided surgical simulation (CASS) and 3D-printing is rapidly gaining traction for a range of surgical applications in paediatric orthopaedics, allowing for extreme personalization and accuracy of the correction, by also reducing operative times and complications. However, prompt availability and accessible costs of this technology remain a concern. Here, we report our experience using an in-hospital low-cost desk workstation for VSP and rapid prototyping in the field of paediatric orthopaedic surgery. From April 2018 to September 2022 20 children presenting with congenital or post-traumatic deformities of the limbs requiring corrective osteotomies were included in the study. A conversion procedure was applied to transform the CT scan into a 3D model. The surgery was planned using the 3D generated model. The simulation consisted of a virtual process of correction of the alignment, rotation, lengthening of the bones and choosing the level, shape and direction of the osteotomies. We also simulated and calculated the size and position of hardware and customized massive allografts that were shaped in clean room at the hospital bone bank. Sterilizable 3D models and PSI were printed in high-temperature poly-lactic acid (HTPLA), using a low-cost 3D-printer. Twenty-three operations in twenty patients were performed by using VSP and CASS. The sites of correction were: leg (9 cases) hip (5 cases)
Among the advanced technology developed and tested for orthopaedic surgery, the Rizzoli (IOR) has a long experience on custom-made design and implant of devices for joint and bone replacements. This follows the recent advancements in additive manufacturing, which now allows to obtain products also in metal alloy by deposition of material layer-by-layer according to a digital model. The process starts from medical image, goes through anatomical modelling, prosthesis design, prototyping, and final production in 3D printers and in case post-production. These devices have demonstrated already to be accurate enough to address properly the specific needs and conditions of the patient and of his/her physician. These guarantee also minimum removal of the tissues, partial replacements, no size related issues, minimal invasiveness, limited instrumentation. The thorough preparation of the treatment results also in a considerable shortening of the surgical and of recovery time. The necessary additional efforts and costs of custom-made implants seem to be well balanced by these advantages and savings, which shall include the lower failures and revision surgery rates. This also allows thoughtful optimization of the component-to-bone interfaces, by advanced lattice structures, with topologies mimicking the trabecular bone, possibly to promote osteointegration and to prevent infection. IOR's experience comprises all sub-disciplines and anatomical areas, here mentioned in historical order. Originally, several systems of Patient-Specific instrumentation have been exploited in total knee and total ankle replacements. A few massive osteoarticular reconstructions in the shank and foot for severe bone fractures were performed, starting from mirroring the contralateral area. Something very similar was performed also for pelvic surgery in the Oncology department, where massive skeletal reconstructions for bone tumours are necessary. To this aim, in addition to the standard anatomical modelling, prosthesis design, technical/technological refinements, and manufacturing, surgical guides for the correct execution of the osteotomies are also designed and 3D printed. Another original experience is about en-block replacement of vertebral bodies for severe bone loss, in particular for tumours. In this project, technological and biological aspects have also been addressed, to enhance osteointegration and to diminish the risk of infection. In our series there is also a case of successful custom reconstruction of the anterior chest wall. Initial experiences are in progress also for shoulder and