Abstract
Introduction
Two randomised trials concluded cast type (above or below elbow) makes no significant difference in the re-displacement rate of paediatric forearm fractures involving the distal third of the radius. This has not, however, led to the universal use of below elbow casts. In particular we noted one trial reported significant re-displacement in 40% or more of cases, which was much higher than we would expect.
To review the radiological outcomes and need for re-manipulation of paediatric distal forearm fractures treated with closed manipulation under anaesthesia in our institution, in part for subsequent comparison with published results.
All forearm fractures treated at a specialist children's hospital in one year were reviewed retrospectively. Based on the methodology of one trial, we included all fractures involving the distal third of the radius, with or without an ulna fracture, which underwent closed manipulation. Outcomes were radiological alignment using existing radiographs and need for re-manipulation. Cast type was at the discretion of the treating surgeon. The radiological criteria for re-displacement were based on published methodology.
79 children underwent manipulation, 71 receiving above elbow casts and 8 below elbow casts. Radiologically 21% of injuries treated in an above elbow cast re-displaced (15/71) compared to 38% of those in below elbow plasters (3/8). In 2 cases the re-displacement was treated with re-manipulation.
The preference in our institution was clearly for above elbow casts in this injury pattern. The small number of below elbow casts in our series limits any comparisons. Our rate of re-displacement using above elbow casts was half that of one of the published studies, so the existing literature is not consistent with our experience.