Advertisement for orthosearch.org.uk
Results 1 - 20 of 104
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 27 - 27
1 Sep 2021
Hess GM Golan J Mozsko S Duarte J Jarzem P Martens F
Full Access

Lumbar fusion remains the gold standard for the treatment of discogenic back pain. Total disc replacement has fallen out of favor in many institutions. Other motion preservation alternatives, such as nucleus replacement, have had limited success and none are commercially available at this time. Two prospective, nonrandomized multicenter studies of lumbar disc nucleus replacement using the PerQdisc 2.0 nucleus replacement device in patients with lumbar discogenic back pain. Early clinical results are presented. A total of 16 patients from 4 international sites (Germany, Paraguay, Canada and Belgium) were enrolled in the trial between May 2019 and February 2021. Data collection points include baseline and postoperatively at 1, 2, 6, and 12 months. Clinical outcome measures were obtained from the Visual Analog Scale (VAS) for back and leg pain, Oswestry Disability Index (ODI), SF-12V2, Analgesic Score (AS), and radiographic assessments. Prospectively gathered data on patient reported outcomes, neurological outcome, surgical results, radiological analysis, and any adverse events. 16 patients had successful implantation of the device. There have been no expulsions of the device. Early postoperative results are available in 13/16 patients at 6 months and 11/16 patients at 12 months. There have been 4 (25%) revision surgeries 3–12 months post implantation between the two trials. 12 of 13 (92%) patients had Minimal Clinically Important Difference (MCID) in ODI at 6 months and 10 of 11 (91%) at 12 months. Mean decrease in ODI from baseline to 12 months was 44.8. At 12 months 8 (73%) patients are not taking pain medication, 1 (9%) patient is taking a narcotic for pain management. 73% of patients are working without restrictions at 12 months post implant. Early clinical and technical results are encouraging. Long term follow up is essential and is forthcoming. Additional patient recruitment and data points are ongoing. FDA/Drug Status Investigational/Not approved


Abstract. MAGnetic Expansion Control (MAGEC) rods are used in the surgical treatment of children with early onset scoliosis. The magnetically controlled lengthening mechanism enables rod distractions without the need for repeated invasive surgery. The CE certification of these devices was suspended in March 2021 due, primarily, to performance evidence gaps in the documents provided by the manufacturer to regulators and notified bodies. MAGEC rods are therefore not permitted for use in countries requiring CE marking. This was a survey of 18 MAGEC rod surgeons in the UK about their perception of the impact of the CE suspension on the clinical management of their patients. Unsurprisingly, virtually all perceived a negative impact, reflecting the complexity of this patient group. Reassuringly, these surgeons are highly experienced in alternative treatment methods. Cite this article: Bone Jt Open 2022;3(2):155–157


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 11 - 11
1 Apr 2012
Newey M Sell P
Full Access

The use of interspinous distraction devices should remain the subject of audit and research. They are a relatively new addition to the armamentarium of surgical treatment of lumbar spinal stenosis. The reported results are variable and there are a number of different devices available. It is recognised that there is an early failure rate with interspinous distraction devices. This is a report of the clinical results after conversion to segmental lumbar decompression following a failure of interspinous distraction procedure. 18 patients had removal of device and conversion to a standard lumbar decompression at an average of 13 months after the index procedure. There were 7 females and 11 males. The average age was 68 years (range 49-85). The two youngest patients had a decompression and instrumented fusion, the others had decompression alone. Prior to the Index procedure of stand alone interspinous distraction device the average Oswestry Disability Index (ODI) was 42 and Visual Analogue Score (VAS) leg 7.2. Prior to revision the average ODI was 42 and VAS leg 6.7. Complications: One intra operative myocardial infarction, one incidental durotomy and one post operative infection (pseudomonas isolated). At a mean of 9 months follow up the average ODI was 23 and VAS leg 2.1. The VAS back was 1.9. The walking distance was subjectively reported as 246 yards pre op and 1100 yards post procedure. There was a clinically significant improvement in all patients. A failed interspinous distraction device can be satisfactorily salvaged with a segmental lumbar decompression


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 51 - 51
1 Apr 2012
Collis RA Kelleher M McEvoy L Bolger C
Full Access

Several surgical options have been utilised to treat patients with back dominant lumbar disc disease. The purpose of our study was to compare the outcomes in patients who underwent lumbar fusion with an expandable interbody device (B-TWIN) using different surgical techniques (PLIF, TLIF or posterolateral screws alone). Observational study, retrospective analysis of prospectively collected data. Patients underwent a single level lumbar fusion. Group A: PLIF with B-Twin cage; Group B: TLIF with B-Twin cage and unilateral pedicle screw fixation and Group C: bilateral posterolateral screw fixation alone. Functional outcomes were assessed using: SF-36, Oswestry Disability Index (ODI), Distress and Risk Assessment Method scores (DRAM) and the visual analogue pain scores (VAS). There were 32 patients, 24 female and 8 male. Average age was 45 (range 33-63). Average follow up was12 months (range 2-36). Level of spinal fusion was 2 L3/4, 11 L4/5 and 13 L5/S1. Mean hospital stay was 5.8 days. VAS improved in all 3 groups A 5.83 – 5; B 8 – 4.83; C 5.71 – 2.3. ODI improved in all 3 groups A 0.5 – 0.35; B 0.51 – 0.44, C 0.42 – 0.16. There was no statistical difference on comparison of the three groups. There were no operative complications. One patient broke her interdody device during a all in the first post-operative week requiring a subsequent procedure. Lumbar interbody fusions can safely be performed using an expandable interbody device. Good functional outcomes can be achieved in the majority of well selected patients


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_2 | Pages 14 - 14
1 Feb 2015
Vadhva M Hoggett L Khatri M
Full Access

Aim. To assess the safety of Zero Profile Interbody fusion (Zero P) device in Anterior Cervical Decompression and fusion (ACDF) for degenerative cervical stenosis. Method. 89 consecutive patients treated with Zero P interbody device from September 2009 to September 2012 were included in this retrospective study. Inclusion criterion: degenerative cervical stenosis with myelopathy, persistent radiculopathy after at least 3 months of failed conservative management. Exclusion criterion: Paediatric population; patients with infection, metastatic disease and trauma. There were 39 females, 50 males with mean age of 55 (ranging from 24 to 84 years). 56 (64%) had surgery at 1 level, 31 (35%) at 2 levels, 1 (1%) at 3 levels. Total number of levels operated were 121. Common levels operated were C56 (62%) and C67 (47%). Majority were operated due to radicular symptoms, 56 (64%) had radicular symptoms, 28(31%) had myelopathy and 5 (5%) Myeloradiculopathy. Results. All had a minimum of 6 months follow up (maximum 2 years). No patient had cage subsidence or extrusion. 1 had superficial infection which settled with antibiotics, 10 (11%) had dysphagia which settled in 6 to12 weeks. Conclusions. Our study demonstrates that ACDF with Zero P can be considered a safe option in management of patients with cervical degenerative stenosis. We would will also recommend a prospective randomised study as a follow on to this retrospective study. Preoperative kyphosis or lordosis did not change the outcome or make the surgical technique any more difficult, hence this implant can also be used in these circumstances. Conflicts of interest: No conflicts of interest. Sources of funding: No funding obtained


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 25 - 25
1 Apr 2012
Kamal T Hegazy A Elikety S Shah N Casha J
Full Access

We are presenting a prospective analysis and assessment for the results of the Coflex@ inter-spinous dynamic stabilization device with a 2 year follow up. The purpose of this study is to assess the efficacy and safety of the Coflex@ Posterior Dynamic Stabilization Implant. A prospective analysis was performed on 121 patients (176 devices) treated with the Coflex@ Interspinous Implant. Indication for the treatment was spinal canal foraminal stenosis with nerve root irritation. Pre- and postoperative disability and pain scores were measured using Oswestry disability score, functional assessment a radiological evaluation at pre-operative - three - six twelve and twenty-four month interval. Data analysis revealed a high rate of patient satisfaction 92% of patients are satisfied and will have the surgery again 81% of patients had major improvement of their leg symptoms. 72% of patients reported improvement of their back pain symptoms this was more noted in the decompression group. Two revision surgeries were carried out. One due to implant back-out and the second due to infection. The Coflex@inter-spinous implant is a simple surgical treatment strategy with a low risk. Early results show a good improvement of both clinical and radiological parameters combined with patient satisfaction with better outcome achieved if combined with spinal decompression


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_4 | Pages 41 - 41
1 Feb 2014
Shostak N Pravdyuk N Muradyants A Atabegashvili M Sidorenkova V
Full Access

Background. Back pain (BP) is a serious problem not only for the elderly, but also young. The non-radiation methods are taking the special relevance in the screening assessment of BP. Objective. To estimate the frequency of occurrence of the BP in young adults and its relation to the functional state of the spine. Methods. The screening conducted 91 medical students (58 women and 33 men) aged 21.3±2.4 years. The research contained a survey on the BP in the last 12 month, and the risk factors, as well as the assessment of functional condition of the spine in three positions using the device ValedoShape (Hocoma, Switzerland). Statistical analysis was performed using Statistica 10.0. Results. A total of 62 (68.1%) students reported BP. In the structure of the BP dominated the lumbar-sacral localization (53.2%). In 90.6% of young people the BP had periodic pattern, 26.7% of students sought medical attention because of the BP. Among the risk factors students mentioned a long stay in a sitting position (51.2%) and weight lifting (35.5%). BP was significantly more frequently among women (71%) and those with scoliosis spine (19.4%). According to the ValedoShape examination the hypermobility of vertebral-motor segment was found in 21 (33.9%) of students with BP, which in 11.3% of the cases had polysegmentary character. Conclusion. 68.1% of young adults had a BP in history. BP was significantly associated with female sex, long-term stay in a sitting position, scoliosis spinal deformity and the loss of segmental integrity (p<0,05)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 102 - 102
1 Apr 2012
Rasul Z Boreham B Sell P
Full Access

Clinical and radiological indicators of outcome in the use of X-Stops were sought by evaluating patient-centred outcomes alongside radiographic scrutiny of changes around implants with correlation to outcome.

Prospectively collated outcome scores were correlated to outcome, with retrospective analysis of pre-operative MRI scans and 117 post-operative radiographs.

Single surgeon series of 44 patients(52 implants).

Clinical - ODI, walking distance, Low Back Outcome Score, MZDI and MSP. Radiographic - lucency(anterior and cranio-caudal to implant), coronal rotation, dorsal migration of implant. Failure defined by persistent symptoms requiring removal+/−decompression.

Pre-operative features of success: lower ODI(p<0.05), higher LBOS(p<0.01), higher walking distance(p<0.01), lower MZDI(p<0.01).

Marked differences were noted in post-operative scores for the two cohorts. An eight-fold improvement in walking distance in success patients compared to an increase to 1.8 times the baseline in failures. ODI improved ten times more in the success group at 20 cf2(failure). MZDI improvement was greater in the revisions at 2.2 cf 0.9 in successes.

Ranking Pearson's coefficient of radiograph measurements in success and failure cohorts, revealed failure associated most to anterior lucency(R=0.93), rotation(R=-0.61), cranio-caudal lucency (R=-0.29) and migration (R=-0.25). Success most associated to rotation (R=-0.22). Failure radiographs revealed greater lucency cranio-caudal and ventral to the implant, more coronal rotation, and pronounced dorsal migration.

Clinical features of success are older patients with no co-morbidities, unilateral leg pain and multi-level insertion. Males, those with bilateral leg pain, and scoliosis or spondylolistheses are more likely to fail.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 543 - 547
1 Apr 2013
Qi M Chen H Liu Y Zhang Y Liang L Yuan W

In a retrospective cohort study we compared the clinical outcome and complications, including dysphagia, following anterior cervical fusion for the treatment of cervical spondylosis using either a zero-profile (Zero-P; Synthes) implant or an anterior cervical plate and cage. A total of 83 patients underwent fusion using a Zero-P and 107 patients underwent fusion using a plate and cage. The mean follow-up was 18.6 months (sd 4.2) in the Zero-P group and 19.3 months (sd 4.1) in the plate and cage group. All patients in both groups had significant symptomatic and neurological improvement. There were no significant differences between the groups in the Neck Disability Index (NDI) and visual analogue scores at final follow-up. The cervical alignment improved in both groups. There was a higher incidence of dysphagia in the plate and cage group on the day after surgery and at two months post-operatively. All patients achieved fusion and no graft migration or nonunion was observed.

When compared with the traditional anterior cervical plate and cage, the Zero-P implant is a safe and convenient procedure giving good results in patients with symptomatic cervical spondylosis with a reduced incidence of dysphagia post-operatively.

Cite this article: Bone Joint J 2013;95-B:543–7.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 83 - 83
1 Jun 2012
Balamurali G Konig M Boszczyk B
Full Access

Aim

A retrospective review of the management of adjacent level discectomy and fusion using a Zero-P (Synthes) cage and report of ease of technique and outcomes.

Method

Surgical approach to adjacent level cervical disc protrusion with previous anterior cervical discectomy and fusion (ACDF) can be difficult. We review 4 patients who had previous ACDF with cage and plate who developed new onset adjacent level cervical disc prolepses causing myelopathy. A retrospective review of demographic data, symptoms, details of surgery, pre and post operative radiology, pre and postoperative ODI and pain score, length of stay, complications and follow-up data were collected in all patients.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 33 - 33
7 Aug 2024
Williams R Evans S Maitre CL Jones A
Full Access

Background. It has become increasingly important to conduct studies assessing clinical outcomes, reoperation rates, and revision rates to better define the indications and efficacy of lumbar spinal procedures and its association with symptomatic adjacent segment degeneration (sASD). Adjacent segment degeneration (ASD) is defined as the radiographic change in the intervertebral discs adjacent to the surgically treated spinal level. SASD represents adjacent segment degeneration which causes pain or numbness due to post-operative spinal instability or nerve compression at the same level. The most common reason for early reoperation and late operation is sASD, therefore is in our best interest to understand the causes of ASD and make steps to limit the occurrence. Method. A comprehensive literature search was performed selecting Randomized controlled trials (RCTs) and retrospective or prospective studies published up to December 2023. Meta-analysis was performed on 38 studies that met the inclusion criteria and included data of clinical outcomes of patients who had degenerative disc disease, disc herniation, radiculopathy, and spondylolisthesis and underwent lumbar fusion or motion-preservation device surgery; and reported on the prevalence of ASD, sASD, reoperation rate, visual analogue score (VAS), and Oswestry disability index (ODI) improvement. Results. When compared to fusion surgery, a significant reduction of ASD, sASD and reoperation was observed in the cohort of patients that underwent motion-preserving surgery. Conclusion. Dynamic fusion constructs are treatment options that may help to prevent sASD. Conflicts of interest. This research was funded by Paradigm Spine. Sources of funding. Paradigm Spine


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 32 - 32
7 Aug 2024
Raftery K Tavana S Newell N
Full Access

Introduction. Vertebral compression fractures are the most common type of osteoporotic fracture. Though 89% of clinical fractures occur anteriorly, it is challenging to replicate these ex vivo with the underlying intervertebral discs (IVDs) present. Furthermore, the role of disc degeneration in this mechanism is poorly understood. Understanding how disc morphology alters vertebral strain distributions may lead to the utilisation of IVD metrics in fracture prediction, or inform surgical decision-making regarding instrumentation type and placement. Aim. To determine the effect of disc degeneration on the vertebral trabecular bone strain distributions in axial compression and flexion loading. Methods. Eight cadaveric thoracolumbar segments (T11-L3) were prepared (N=4 axial compression, N=4 flexion). µCT-based digital volume correlation was used to quantify trabecular strains. A bespoke loading device fixed specimens at the resultant displacement when loaded to 50N and 800N. Flexion was achieved by adding 6° wedges. Disc degeneration was quantified with Pfirrmann grading and T2 relaxation times. Results. Anterior axial strains were 80.9±39% higher than the posterior region in flexion (p<0.01), the ratio of which was correlated with T2 relaxation time (R. 2. =0.80, p<0.05). In flexion, the central-to-peripheral axial strain ratio in the endplate region was significantly higher when the underlying IVDs were non-degenerated relative to degenerated (+38.1±12%, p<0.05). No significant differences were observed in axial compression. Conclusion. Disc degeneration is a stronger determinant of the trabecular strain distribution when flexion is applied. Load transfer through non-degenerate IVDs under flexion appears to be more centralised, suggesting that disc degeneration predisposes flexion-type compression fractures by shifting high strains anteriorly. Conflicts of interest. The authors declare none. Sources of funding. This work was funded by the Engineering & Physical Sciences Research Council (EP/V029452/1), and Back-to-Back


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 43 - 43
7 Aug 2024
Johnson K Pavlova A Swinton P Cooper K
Full Access

Purpose and background. Work-related musculoskeletal disorders, particularly back pain, are a significant issue for healthcare workers, with patient handling being the most frequently reported risk factor. Patient handling is often performed without assistive devices or equipment, which can cause healthcare staff to maintain awkward postures or experience high loads. This review aimed to comprehensively map the literature surrounding manual patient handling (without assistive devices) by healthcare practitioners to identify the current evidence-base on moving and handling of patients and explore what primary research had been conducted. Methods and results. JBI methodology for scoping reviews and an a priori registered protocol (DOI 10.17605/OSF.IO/8PR7A) was followed and AMED, CINAHL, MEDLINE, SPORTDiscus and EMBASE databases were searched. Literature published in English between 2002 and 2021 was included. Forty-nine records were included: 36 primary research studies, 1 systematic review and 12 ‘other’ including narrative and government reports. Primary research predominantly used observational cross-sectional designs (n = 21 studies). Most studies took place in hospitals (n = 13) and laboratories (n = 12). Nurses formed the largest population group (n = 13), with very little research on physiotherapists and other allied health professionals. Conclusion. This scoping review comprehensively reviewed the available literature in the area. Most of the included primary research was observational. Nurses were often investigated in hospitals and laboratories. Qualitative research investigating moving and handling and further biomechanical investigation into therapeutic handling by healthcare staff were identified as areas for further research. Conflicts of interest. None. Sources of funding. None. This work has been published in Physiotherapy: Johnson, K., Swinton, P., Pavlova, A. and Cooper, K., 2023. Manual patient handling in the healthcare setting: a scoping review. Physiotherapy. (120) 60–77 . https://doi.org/10.1016/j.physio.2023.06.003


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 8 - 8
1 Aug 2022
Sharma A Grannum S de Koning R Thakar C Nnadi C
Full Access

Surgical site infections following spinal surgery profoundly influence continued treatment, significantly impacting psychological and economic dimensions and clinical outcomes. Its reported incidence varies up to 20%, with the highest incidence amongst neuromuscular scoliosis and metastatic cord compression patients. We describe the first reported biphasic osteoconductive scaffold (Cerament G) with a logarithmic elution profile as a cumulative strategic treatment modality for adjacent spinal surgery infections. All patients who developed surgical site infections following instrumented fusion (May 2021-December 2021) had their demographics (age, sex), type and number of procedures, isolated organism, antibiotics given, comorbidities, and WHO performance status analysed. The infected wound was debrided to healthy planes, samples taken, and Cerament g applied. Thirteen patients were treated for deep SSI following spinal instrumentation and fusion procedures with intraoperative Cerament G application. There were four males and nine females with an average age of 40 ranging between 12 and 87. Nine patients underwent initial surgery for spinal deformity, and four were treated for fractures as index procedure. 77% of infections were attributable to MSSA and Cutibacteriousm acnes; others included Klebsiella, Pseudomonas and Streptococcus and targeted with multimodal cumulative therapy. A WHO performance score improved in 11 patients. In addition, there was no wound leak, and infection was eradicated successfully in 12/13 with a single procedure. This series shows the successful eradication of the infection and improved functional outcomes with Cerament G. However, the low numbers of patients in our series are an essential consideration for the broader applicability of this device


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 1 - 1
1 Aug 2022
Nicholson T Foster N Haj AE Ede MN Jones S
Full Access

We previously reported that osteoblasts at the curve apex in adolescent idiopathic scoliosis (AIS) exhibit a differential phenotype, compared to non-curve osteoblasts(1). However, the Hueter-Volkmann principle on vertebral body growth in spinal deformities (2) suggests this could be secondary to altered biomechanics. This study examined whether non-curve osteoblasts subjected to mechanical strain resemble the transcriptomic phenotype of curve apex osteoblasts. Facet spinal tissue was collected perioperatively from three sites, (i) the concave and (ii) convex side at the curve apex and (iii) from outside the curve (non-curve) from six AIS female patients (age 13–18 years; NRES 19/WM/0083). Non-curve osteoblasts were subjected to strain using a 4-point bending device. Osteoblast phenotype was determined by RNA sequencing and bioinformatic pathway analysis. RNAseq revealed that curve apex osteoblasts exhibited a differential transcriptome, with 1014 and 1301 differentially expressed genes (DEGs; p<0.05, fold-change >1.5) between convex/non-curve and concave/non-curve sites respectively. Non-curve osteoblasts subjected to strain showed increased protein expression of the mechanoresponsive biomarkers COX2 and C-Fos. Comparing unstimulated vs strain-induced non-curve osteoblasts, 423 DEGs were identified (p<0.05, fold-change >1.5). Of these DEGs, only 5% and 6% were common to the DEGs found at either side of the curve apex, compared to non-curve cells. Bioinformatic analysis of these strain-induced DEGs revealed a different array of canonical signalling pathways and cellular processes, to those significantly affected in cells at the curve apex. Mechanical strain of AIS osteoblasts in vitro did not induce the differential transcriptomic phenotype of AIS osteoblasts at the curve apex


Full Access

Introduction. Missile injuries are very serious injuries particularly in the cervical region. They are classified into high and low missile injuries when it involves the cervical spine. In modern guerrilla warfare, one must be aware of ballistic pathology with bullets as well as from explosives. In particular, improvised explosive devices commonly known as IED's play a new and important pathophysiology whether they are suicided vests or roadside bombs. They usually produce severe or lethal injuries and serious neurovascular deficit is frequent. We present the details of 40 patients with local experience on how to handle serious penetrating cervical missile injuries. Methods. All cases were collected from the record of Basrah University Hospital, Iraq. Healthy military gentlemen with ages ranging between 20–35 years were included. Results. 11 patients had bullet injuries and 29patients had fragments of shell injuries. The sites of injuries were 9: C2–C3, 12: C5–C6, 12: C4–C5 and 7: C7-T1. Bullet entrance was anterior in 23 patients, posterior in 7 patients and lateral in 10 patients. The cervical vertebrae were injured in 37 patients at body or lamina level while in 3 patients it was only neural tissue injuries. Missiles were retained in 13 patients. All injuries showed some degree of neurological deficit with quadriplegia in 26 patients. 9 patients presented with very serious injuries. No relation was found between the size of the missile and the extent of damage. Outcome of treatment in all patients was poor. Conclusion. Gunshot wounds only account for approximately one third of penetrating missile injuries in patients who survive and are well enough to receive medical treatment. 62% of patients' cohort were from explosive devices, consistent with data from 2010, where 58% of fatalities were from IED's occurring in foreign soldiers in Afghanistan. We discuss the importance of general supportive measures, generous wound excision, removal of the retained missiles and heavy cover of antibiotics


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 4 - 4
1 Aug 2022
Watson F Loureiro RCV Leong JJH
Full Access

There is a need for non-radiographic, objective outcome measures for children with Adolescent Idiopathic Scoliosis (AIS). Standing balance and stability is altered in children with AIS. The Margin of Stability (MoS) has been used to compare gait stability in clinical populations. Our objective was to compare the MoS in anterior-posterior (MoS. AP. ) and mediolateral (MoS. ML. ) directions in girls with AIS to Controls. Girls with AIS and healthy girls walked at three speeds on an instrumented treadmill wearing retroreflective markers, surrounded by motion capture cameras. The MoS. AP/ML. was calculated at left and right heel strike. Data was processed in Visual 3D. A two-way ANOVA was used to compare MoS. AP/ML. between group, speed and the interaction between group and speed. Pearson's correlation coefficient was used to compare the MoS to Cobb angle. Statistical significance was accepted when p > 0.05. A priori power analysis suggested 12 participants per group. Three Cases and four Controls were recruited. Girls with AIS all had right-sided main thoracic curves (Lenke type 1a, 61.3° ± 10.0°). MoS. AP. was significantly bigger for Cases compared to Controls on the left (p=0.038) and right foot (p=0.041). There was no significant difference between Cases and Controls for MoS. ML. , but there was a visual trend for a smaller MoS. ML. in Cases. There was no significant difference for speed or the interaction between group and speed for MoS. AP. or MoS. ML. In Cases, MoS. AP. increased with increasing Cobb angle on the left (r. 2. =0.687, p=0.054) and right (r. 2. =0.634, p=0.067) and MoS. ML. decreased with increasing Cobb angle on the left (r. 2. =-0.912, p=0.002). Further subjects are being recruited. Girls with Lenke type 1a AIS are more stable in the AP direction and less stable in the ML direction than Controls during treadmill walking. AP stability increases and ML stability decreases with increasing Cobb angle. This research suggests that the MoS could be used as an outcome measure for children with AIS. Continued work is required to increase the power of this study. Further work could consider these changes during walking overground, measuring an MoS or MoS-like measure using a wearable device, and in different curve types


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 3 - 3
1 Sep 2021
Tsang E Lupu C Fragkakis A Bernard J Bishop T Lui D
Full Access

Introduction. The British Spinal Registry (BSR) is a web-based database commissioned by the British Association of Spine Surgeons (BASS) in the UK. It allows auditing of spinal surgery outcomes, patient's safety and overall experience. The clinical data include patient's demographics which is entered into the Registry by medical staff, as well as patient-reported outcome measures (PROM) that is submitted to the Registry by the patient themselves at different time periods post-operatively. It has the ability to register Device and Implants as well as co-ordinate multicentre research. This study is to identify both the staff and patient compliance regarding to data submissions to the BSR at St. George's Hospital NHS Trust. Methods and Materials. Retrospective analysis of the BSR data for all spinal surgeries that was performed at SGH by the three Complex Spinal Surgery Consultants between 1st January 2017 to 31st December 2018. This study period allowed up to 12 months PROM data analysis. Staff and Patient compliance were analysed separately depend on the data they submitted. Results. 404 (n) spinal surgeries were performed over this two-year period. Surgical demographics: 39.4% (159/404) males and 56.2% (227/404) females, 4.5% (18/404) declined to be added. Age ranging from 6 to 92, mean age was 47.9. Staff compliance was 89.4% for the registration of patient data. Trauma and tumour patients were excluded as they are not required to complete any pre-operative PROMs. For the remaining patients, 35.8% (116/324) completed their baseline pre-operative PROMs. A steady decrease in patient compliance for post-operative PROMS was observed: 29.8% (2 weeks), 24.9% (6 weeks), 21.2% (6 months), 17.1% (12 months), and 16.6% (24 months). Conclusions. We identified a poor patient compliance in both pre-operative and post-operative PROMS. Patient questionnaire fatigue can occur over time which results in falling compliance to PROMS in 12 months and 24 months. Moreover, patients who do not provide an email address are less likely to fill in their PROMS. Satisfactory compliance for staff regarding to BSR utilisation are shown. Staff should aim to achieve a higher level of compliance as this will help to keep a record of all spinal surgeries that are performed and any complications that are encountered in a particular centre. Over the past three years, the BSR had introduced various schemes to drive up utilisation including a Best Practice Tariff in 2019. Part of the tariff will be withheld when staff failure to enter patients onto the Registry. Further research is needed to determine why there is such fall off especially with patient compliance and to elucidate potential measures to improve their compliance


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 507 - 515
1 Apr 2018
Nnadi C Thakar C Wilson-MacDonald J Milner P Rao A Mayers D Fairbank J Subramanian T

Aims. The primary aim of this study was to evaluate the performance and safety of magnetically controlled growth rods in the treatment of early onset scoliosis. Secondary aims were to evaluate the clinical outcome, the rate of further surgery, the rate of complications, and the durability of correction. Patients and Methods. We undertook an observational prospective cohort study of children with early onset scoliosis, who were recruited over a one-year period and followed up for a minimum of two years. Magnetically controlled rods were introduced in a standardized manner with distractions performed three-monthly thereafter. Adverse events which were both related and unrelated to the device were recorded. Ten children, for whom relevant key data points (such as demographic information, growth parameters, Cobb angles, and functional outcomes) were available, were recruited and followed up over the period of the study. There were five boys and five girls. Their mean age was 6.2 years (2.5 to 10). Results. The mean coronal Cobb angle improved from 57.6° (40° to 81°) preoperatively, 32.8° (28° to 46°) postoperatively, and 41° (19° to 57°) at two years. Five children had an adverse event, with four requiring return to theatre, but none were related to the device. There were no neurological complications or infections. No devices failed. One child developed a proximal junctional kyphosis. The mean gain in spinal column height from T1 to S1 was 45.4 mm (24 to 81) over the period of the study. Conclusion. Magnetically controlled growth rods provide an alternative solution to traditional growing rods in the surgical management of children with early onset scoliosis, supporting growth of the spine while controlling curve progression. Their use has clear psychosocial and economic benefits, with the reduction of the need for repeat surgery as required with traditional growing rods. Cite this article: Bone Joint J 2018;100-B:507–15


Bone & Joint Open
Vol. 5, Issue 9 | Pages 809 - 817
27 Sep 2024
Altorfer FCS Kelly MJ Avrumova F Burkhard MD Sneag DB Chazen JL Tan ET Lebl DR

Aims

To report the development of the technique for minimally invasive lumbar decompression using robotic-assisted navigation.

Methods

Robotic planning software was used to map out bone removal for a laminar decompression after registration of CT scan images of one cadaveric specimen. A specialized acorn-shaped bone removal robotic drill was used to complete a robotic lumbar laminectomy. Post-procedure advanced imaging was obtained to compare actual bony decompression to the surgical plan. After confirming accuracy of the technique, a minimally invasive robotic-assisted laminectomy was performed on one 72-year-old female patient with lumbar spinal stenosis. Postoperative advanced imaging was obtained to confirm the decompression.