We report the outcome of 84 nonunions involving
long bones which were treated with rhBMP-7, in 84 patients (60 men:
24 women) with a mean age 46 years (18 to 81) between 2003 and 2011.
The patients had undergone a mean of three previous operations (one
to 11) for nonunion which had been present for a mean of 17 months
(4 months to 20 years). The nonunions involved the lower limb in
71 patients and the remainder involved the upper limb. A total of 30
nonunions were septic. Treatment was considered successful when
the nonunion healed without additional procedures. The relationship
between successful union and the time to union was investigated
and various factors including age and gender, the nature of the
nonunion (location, size, type, chronicity, previous procedures,
infection, the condition of the soft tissues) and type of index
procedure (revision of fixation, type of graft, amount of rhBMP-7) were
analysed. The improvement of the patients’ quality of life was estimated
using the Short Form (SF) 12 score. A total of 68 nonunions (80.9%) healed with no need for further
procedures at a mean of 5.4 months (3 to 10) post-operatively. Multivariate
logistic regression analysis of the factors affecting union suggested
that only infection significantly affected the rate of union
(p = 0.004).Time to union was only affected by the number of previous
failed procedures
(p = 0.006). An improvement of 79% and 32.2% in SF-12 physical and
mental score, respectively, was noted within the first post-operative
year. Rh-BMP-7 combined with bone grafts, enabled healing of the nonunion
and improved quality of life in about 80% of patients. Aseptic nonunions
were much more likely to unite than septic ones. The number of previous
failed operations significantly delayed the time to union. Cite this article:
Triple arthrodesis is the most effective treatment resource for restoring shape and stability to the hind-foot. It is used in order to achieve a plantigrade foot, aligned, stable and painless, in the treatment of various pathologies. However, it has the effect of changing the dynamic mobility of the foot and diminishes the adapting ability to uneven ground, influencing the outcome. Opinions differ on the necessity of internal fixation to maintain the proper alignment of the hind-foot and improve
Aims. The management of a significant bony defect following excision
of a diaphyseal atrophic femoral nonunion remains a challenge. We
present the outcomes using a combined technique of acute femoral
shortening, stabilized with a long retrograde intramedullary nail,
accompanied by bifocal osteotomy compression and distraction osteogenesis with
a temporary monolateral fixator. Patients and Methods. Eight men and two women underwent the ‘rail and nail’ technique
between 2008 and 2016. Proximal locking of the nail and removal
of the external fixator was undertaken once the length of the femur
had been restored and prior to full
Several low energy osteotomy techniques are described in the literature but there is limited evidence comparing healing indices. We present a retrospective review of two techniques to evaluate an optimum method. Method:. Two cohorts of patients underwent osteotomy of the tibia using a Gigli saw (n=15) or DeBastiani corticotomy (n=12) technique. Indications for surgery included limb lengthening and bone transport for defect reconstruction with a minimal distraction of 2 cm. The patient radiographs were anonymised and the regenerate assessed by the two senior authors who were blinded to the osteotomy type. Bone quality was recorded along the anterior, posterior, medial and lateral cortices, graded 1–5 from absent to full
Objectives. The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator. Materials and Methods. An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing
Fracture-related infections (FRIs) are a devastating complication of fracture management. However, the impact of FRIs on mental health remains understudied. The aim of this study was a longitudinal evaluation of patients’ psychological state, and expectations for recovery comparing patients with recurrent FRI to those with primary FRI. A prospective longitudinal study was conducted at a level 1 trauma centre from January 2020 to December 2022. In total, 56 patients treated for FRI were enrolled. The ICD-10 symptom rating (ISR) and an expectation questionnaire were assessed at five timepoints: preoperatively, one month postoperatively, and at three, six, and 12 months.Aims
Methods
Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures. We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.Aims
Methods
Introduction and objectives. Intramedullary nailing is indicated to stabilization of tibia shaft fractures. Intramedullary nailing through an infra-patellar incision is commonly the technique of choice. While intramedullary nailing of simple diaphyseal fracture patterns is relatively easy, proximal tibia fractures, extremely comminuted/segmental tibia fractures, politrauma with multiple fractures in both extremities and reconstruction of bone loss segment with stiffness of the knee joint can be very challenging to treat. A novel technique for intramedullary tibia nailing through the patella-femoral joint is described. This technique allow extension tibia during intervention time and it supplies easier reduction of the pattern of fracture above. The purpose of our investigation was to evaluate the use of this new technique in described above pattern fracture and patient situation; because we have thought that new technique can perform better outcomes in this situations. Materials and Methods. An observational study of tibia fractures or bone defect was performed for consecutive patients who presented: proximal tibia fractures, extremely comminuted/segmental tibia fractures, politrauma with multiple fractures in both extremities and reconstruction of bone loss segment in the Trauma unit of our institution from September 2009 to August 2010. A total of 32 were included in our study, which performed surgery intervention with Trigen tibia nail (Smith & Nephew, Memphis) with suprapatelar device. Demographic data, mechanism of injury, fracture classification, ROM (2 and 6 weeks, and 3 months),
Tobacco, in addition to being one of the greatest public health threats facing our world, is believed to have deleterious effects on bone metabolism and especially on bone healing. It has been described in the literature that patients who smoke are approximately twice as likely to develop a nonunion following a non-specific bone fracture. For clavicle fractures, this risk is unclear, as is the impact that such a complication might have on the initial management of these fractures. A systematic review and meta-analysis were performed for conservatively treated displaced midshaft clavicle fractures. Embase, PubMed, and Cochrane Central Register of Controlled Trials (via Cochrane Library) were searched from inception to 12 May 2022, with supplementary searches in Open Grey, ClinicalTrials.gov, ProQuest Dissertations & Theses, and Google Scholar. The searches were performed without limits for publication date or languages.Aims
Methods
Background:. Segmental defects of long bones are notoriously demanding and difficult to treat. We evaluate nine cases where the Masquelet induced membrane technique to substitute bone loss has been used. We discuss the method compared to other types of bone reconstruction and share our tips and tricks to reduce treatment time and improve patient comfort. Method:. Eight patients (nine injuries) operated between 2011 and 2014 were included. Four were infected. Outcome was time-to weight-bearing,
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
Due to the recent rapid expansion of scooter sharing companies, there has been a dramatic increase in the number of electric scooter (e-scooter) injuries. Our purpose was to conduct a systematic review to characterize the demographic characteristics, most common injuries, and management of patients injured from electric scooters. We searched PubMed, EMBASE, Scopus, and Web of Science databases using variations of the term “electric scooter”. We excluded studies conducted prior to 2015, studies with a population of less than 50, case reports, and studies not focused on electric scooters. Data were analyzed using Aims
Methods
Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures.Aims
Methods
The aim of this study was to perform the first population-based description of the epidemiological and health economic burden of fracture-related infection (FRI). This is a retrospective cohort study of operatively managed orthopaedic trauma patients from 1 January 2007 to 31 December 2016, performed in Queensland, Australia. Record linkage was used to develop a person-centric, population-based dataset incorporating routinely collected administrative, clinical, and health economic information. The FRI group consisted of patients with International Classification of Disease 10th Revision diagnosis codes for deep infection associated with an implanted device within two years following surgery, while all others were deemed not infected. Demographic and clinical variables, as well as healthcare utilization costs, were compared.Aims
Methods
Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central bone grafting and compared them to those of 20 who were treated with a traditional posterolateral graft. Central bone grafting entails a lateral approach, anterior to the fibula and interosseous membrane which is used to create a central space filled with cancellous iliac crest autograft. Upon
AIM. SIGN-nail system was elaborated to reduce the need in image intensifier during IM-nailing and to allow use of this method in poor countries with restricted medical facilities. The aim of this study was to evaluate efficacy of SIGN-nailing in tibia fractures treatment. MAT. 119 patients with 120 tibia fractures were treated with SIGN nails from 2006 to 2009. Mean age 41.4±12.9 years (17–72). Closed fractures - 106, open - 14 (Gustilo I-6, II-6, III-2 III). Interval from the injury to operation: 6.24±7.9 days (0–45); 71.7% of patients were operated within a week after the injury. Closed reposition achieved in all but 7 cases. Manual reaming was performed in most cases, power -9, no reaming -8 cases. Distal locking was performed with use of supplied jig. RES. Satisfactory reposition and fixation was achieved in most cases, axial deviations more than 5° were noticed post-operatively in 6 cases, or developed within 2 months in other 2, but were well tolerated clinically. All deviations were seen in joint-adjacent fractures (proximal 5, distal 3). Purulent complications were seen in 2 cases (1.6%). Follow-up results in terms exceeding 12 months were obtained in 106 patients (mean 13.6±6.6, range 6–36). No non-unions were seen. Delayed unions - 8 patients (6 of them with proximal third fractures). Radiological
Introduction. Vitamin E stabilization of radiation crosslinked UHMWPE is done by (1) blending into the resin powder,
Introduction. The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower limb lengthening. To assess macroscopic and microscopic changes to the implants and assess differences following design modification, with identification of potential surgical, implant and patient risk factors. Method. 15 nails were retrieved from 13 patients following lower limb lengthening. Macroscopic and microscopic surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analysed with Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy to identify corrosion. Results. 7 male and 3 females underwent 12 femoral lengthenings, 9 antegrade and 3 retrograde. 3 females underwent tibial lengthening. All patients obtained the desired length with no implant failure and full regenerate
Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.Aims
Methods
Background:. Little is known about the forces carried by the Taylor Spatial Frame (TSF) hexapod fixator. Our aim was to measure the TSF resultant force and how this changed during the