Advertisement for orthosearch.org.uk
Results 1 - 20 of 25
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 643 - 645
1 Jul 2000
Mohan N Hunter JB Colton CL

Our study describes a posterolateral approach to the distal humerus for open reduction and internal fixation of displaced fractures of the lateral condyle. A total of 20 patients had open reduction and internal fixation over a four-year period using this approach, and at a mean follow-up of 12 months had full union, range of movement and no complications, either clinical or radiological. This approach is well suited to the exact visualisation and accurate reduction of this difficult fracture with minimal dissection of tissues


Bone & Joint Open
Vol. 4, Issue 10 | Pages 728 - 734
1 Oct 2023
Fokkema CB Janssen L Roumen RMH van Dijk WA

Aims

In the Netherlands, general practitioners (GPs) can request radiographs. After a radiologically diagnosed fracture, patients are immediately referred to the emergency department (ED). Since 2020, the Máxima Medical Centre has implemented a new care pathway for minor trauma patients, referring them immediately to the traumatology outpatient clinic (OC) instead of the ED. We investigated whether this altered care pathway leads to a reduction in healthcare consumption and concomitant costs.

Methods

In this retrospective cohort study, patients were included if a radiologist diagnosed a fracture on a radiograph requested by the GP from August to October 2019 (control group) or August to October 2020 (research group), on weekdays between 8.30 am and 4.00 pm. The study compared various outcomes between groups, including the length of the initial hospital visit, frequency of hospital visits and medical procedures, extent of imaging, and healthcare expenses.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 238 - 238
1 Sep 2012
Ishii Y Noguchi H Takeda M Sato J
Full Access

The purpose of this study is to analyze what kind of pattern of change in each posterior femoral condyle allows for a greater degree of flexion after total knee arthroplasty (TKA). The flexion angle was assessed pre-operatively, and at 12 months after the surgery in 98 patients (106 knees) who underwent consecutive TKA. We used a quantitative 3 dimensional technique using computed tomography for the assessment of changes in both the medial and lateral femoral condylar offset. There were no significant correlation between changes of each posterior condylar offset and post flexion angle (medial condyle; R=−0.038, p=0.70, lateral condyle; R=−0.090, p=0.36). There were no significant differences between changing patterns and increase rate of flexion (p=0.443). Additionally there were no significant differences between changing patterns and increase of flexion angle (p=0.593). Changes of each posterior condylar offset were no correlation to knee flexion after TKA in the current design prosthesis


Bone & Joint Research
Vol. 2, Issue 2 | Pages 26 - 32
1 Feb 2013
Neumann H Schulz AP Gille J Klinger M Jürgens C Reimers N Kienast B

Objectives. Osteochondral injuries, if not treated adequately, often lead to severe osteoarthritis. Possible treatment options include refixation of the fragment or replacement therapies such as Pridie drilling, microfracture or osteochondral grafts, all of which have certain disadvantages. Only refixation of the fragment can produce a smooth and resilient joint surface. The aim of this study was the evaluation of an ultrasound-activated bioresorbable pin for the refixation of osteochondral fragments under physiological conditions. Methods. In 16 Merino sheep, specific osteochondral fragments of the medial femoral condyle were produced and refixed with one of conventional bioresorbable pins, titanium screws or ultrasound-activated pins. Macro- and microscopic scoring was undertaken after three months. . Results. The healing ratio with ultrasound-activated pins was higher than with conventional pins. No negative heat effect on cartilage has been shown. Conclusion. As the material is bioresorbable, no further surgery is required to remove the implant. MRI imaging is not compromised, as it is with implanted screws. The use of bioresorbable pins using ultrasound is a promising technology for the refixation of osteochondral fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 253 - 253
1 Sep 2012
Solgaard L Moeller L Sandberg T
Full Access

Introduction. Unicompartmental arthroplasty is still a controversial issue in knee replacement, mainly due to a marked variation in published survival rates of the implants. The aim of this study was to analyse possible risk factors for revision following Oxford unicompartmental knee arthroplasties (OUKA). Material and methods. Since 1997 data for all patients with primary and revision knee arthroplasties performed in our department have been stored in a database. Selected for the present study was all primary OUKA performed in the period 1997–2006 as well as any revision following these operations until the end of 2008. We got information from The National Health Register and the CPR register about any revision performed at other institutions and date in case of death. Primary OUKA were grouped in three categories according to the experience of the surgeon: 1 for operation done by a surgeon who had performed less than 20 OUKA, 2 for operation by a surgeon who had performed 20–40, and 3 for operation by a surgeon who had performed more than 40. Risk of revision was analysed by Cox regression. Revisions due to pain as the only reason were excluded from the analyses. Age and gender of the patients, previous surgical intervention, operation time, and the experience of the surgeon were included as possible risk factors in the analysis. Results. 445 primary Oxford knee arthroplasties were included. These were followed by 46 revisions. The indications for the revisions were: aseptic loosening 16 knees, progression of the osteoarthritis to the lateral compartment 7 knees, dislocation of the polyethylene meniscus 5 knees, varus-valgus instability 3 knees, fracture of the medial tibia condyle 3 knees, collision of the polyethylene meniscus and the femur condyle 1 knee, and pain as the only reason 11 knees. Age and gender of the patients as well as previous surgical intervention in the knee in question were not correlated to the risk of revision. Operation time was correlated to risk of revision with decreasing risk with increasing operation time (p=0,001). The experience of the surgeon was also correlated to risk of revision with decreasing risk with increasing experience (p=0,02). The 6 years survival rate for an experienced surgeon using an operation time at 90 min. or more was 97,5 % compared to a survival rate at 78,7 % for an inexperienced surgeon with an operation time less than 90 min. Conclusion. OUKA performed by an inexperienced surgeon and OUKA performed with short operation time had marked reduced survival rates. This seems to be an essential information to institutions performing OUKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 316 - 316
1 Sep 2012
Pandorf T Preuss R Flohr M Upmann C
Full Access

Introduction. In knee arthroplasty a ceramic component has several advantages: first, there is no ion release implying a risk for potential allergies. Second, the hardness of the material leads to a scratch resistance which ultimately reduces PE wear over time. In the past, ceramic components in knee applications were limited in the variety of design possibilities due to necessary thickness of the component resulting from the associated fracture risk of ceramics. By the development of an alumina matrix composite material with increased mechanical properties it is possible to develop ceramic knee components which have nearly the same design as a metal component and use the same implantation technique as well as the same instruments. This offers the surgeon the opportunity to choose intraoperatively between metal or ceramic knee components. Extensive in-vitro testing shows that ceramic knee components achieve superior mechanical test results. The reliability of the components is proven by two different burst tests and a fatigue test for both a femoral and a tibial ceramic knee component. Material and method. The mechanical proof-test was developed by subsequent steps of numerical load/stress analysis and design of an adequate mechanical test equipment. The procedure was organized as follows:. Oncologic: Analysis of relevant maximum in-vivo loading conditions. Analysis of the “boundary conditions”. Finite Element analysis: Identifying regions of highest stress concentration. Design analysis and accommodation if necessary. Development of an adequate mechanical test equipment which produces stresses comparable to the in-vivo conditions. Performing mechanical tests with ceramic femoral components. Validation of the test concept: comparison of test results and stress analysis. Assign “safety margin”,. Establish “proof test”. Results. Two independent load scenarios have been determined for each type of components as being in-vivo relevant. Hence, the developed proof-test consists of two subsequent load tests, the so-called regular test and the tension test for the femoral components, and the upper side test and the lower side test for the tibial components. In the regular test, the mechanical strength of the polished outer condyles is tested using a force which is equivalent to an in-vivo loading of 16 times bodyweight. In the tension test, the interior sides of the condyles are stressed in the sagittal plane ensuring a mechanically reliable implantation. This test is performed with a force equivalent to 10 times bodyweight. Discussion. The procedure to determine the proof loads using the maximum in-vivo loads together with a safety factor ensures the mechanical safety of the ceramic knee component. Together with the well-known excellent wear and biological behaviour of ceramics, this application provides an alternative to common metallic knee components. Clinical observations in the framework of a multi-centre study in different European countries have been started and show very promising results


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 13 - 13
1 Jun 2016
Hindle P Khan N Baily J Biant L Simpson H Péault B
Full Access

Our unpublished data has indicated that the perivascular stem cells (PSCs) have increased chondrogenic potential compared to mesenchymal stem cells (MSCs) derived in culture. There has been a recent change in the theory that stem cells work by a paracrine effect rather than differentiation. There are minimal data demonstrating the persistence of implanted stem cells when used for engraftment. This study aimed to develop an autologous large animal model for perivascular stem cells as well as to determine if cells were retained in the articular cartilage defects. The reactivity of anti-human and anti-ovine antibodies was ascertained using immunohistochemistry and fluorescence-activated cell sorting (FACS). A panel of antibodies were combined and used to identify and purify pericytes (CD34-CD45-CD146+) and adventitial cells (CD34+CD45-CD146-) using FACS. The purified cells were cultured and their identity checked using FACS. These cultured cells demonstrated osteogenic, adipogenic and chondrogenic potential. Autologous ovine PSCs (oPSCs) were isolated, cultured and transfected using a GFP virus. The transfection rate was 88%. The cells were implanted into an articular cartilage defect on the medial femoral condyle using a hydrogel, four weeks following implantation the condyle was explanted and confocal laser scanning microscopy demonstrated the presence of oPSCs in the defect. Histology did not demonstrate any repair tissue at this early time point. These data have confirmed the viability our large animal model and that the implanted stem cells were retained in the defect four weeks following implantation


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims

The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years.

Methods

From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 46 - 46
1 Apr 2013
Iga T Karita T Sato W Okazaki H Tatsumi T Touhara C Nishikawa T Nagai I Ushita M Matsumoto T Kondo T
Full Access

Introduction. In oblique olecranon fracture, fracture line begins in the trochlear notch and proceeds distally to the dorsal cortex of the ulna. We have experienced a nonunion of reverse oblique fracture. Hypothesis. Reverse oblique olecranon fracture has instability. Materials & Methods. 130 patients with an olecranon fracture were retrospectively evaluated. Inclusion criteria are that fracture line begins at the base of the coronoid process, distal portion of the trochlear notch, and proceeds proximally to the dorsal cortex of the ulna on the lateral radiograph. Fractures with articular comminution were excluded. Results. Seven patients met the criteria. They were associated with local injuries: anterior translation of the proximal radius and ulna, fracture of the medial epicondyle or the lateral condyle of the humerus. One out of five patients treated with tension band wiring (TBW) was revised with screw fixation because of nonunion. Discussion. The associated injuries suggested the anterior and valgus instability. A nonunion case suggests a requirement of more secure fixation. However, these findings are common in distal olecranon fracture. Therefore, the instability in our series is due to the distal location of fracture on the trochlear notch rather than reverse obliquity. The reverse obliquity attributes to small proximal fragment. Conclusion. Reverse oblique olecranon fracture has instability because of its distal location. It should be distinguished from simple, stable fracture


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims

Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP.

Methods

This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 74 - 77
1 Jan 2003
Simonis RB Nuñez VA Khaleel A

Between 1993 and 2000 we treated 14 patients with nonunion of fractures of the distal humerus; 11 had already had previous fixation which had failed. The mean time to surgery was 21 months after injury. All the fractures were very low which made it difficult to obtain a firm hold of the small distal fragment. The problem of fixation was addressed by inserting a Coventry infant hip screw into the humeral condyles. The screw has a thread of wide diameter which gives excellent purchase on the small distal fragment. The condyles can then be compressed on to the humeral shaft using a 4.5 mm narrow tibial dynamic plate. Of these 14 difficult cases of nonunion, 12 progressed to union


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 182 - 182
1 Sep 2012
Martinez Carranza N Nurmi-Sandh H Lagerstedt A Hultenby K Berg H Ryd L
Full Access

Single focal grade IV cartilage lesion in the knee has a poor healing capacity. Instead these lesions often progress to severe and generalized osteoarthritis that may result in total knee replacement. Current treatment modalities aim at biological repair and, although theoretically appealing, the newly formed tissue is at the best cartilage-like, often fibrous or fibrocartilaginous. This at the expense of sophisticated laboratory resources, delicate surgery and strict compliance from patients. An alternative may be small implants of biomaterial inserted to replace the damaged cartilage. We investigated the response of the opposing tibia cartilage to a metallic implant inserted at different depth into the surrounding cartilage level. Methods. The medial femoral condyle of both knees of 12 sheep, 70–90kg, 2 year of age and from the same breeder, was operated. A metallic implant with an articulating surface of 316L stainless steel, diameter of 7mm, HA plasma sprayed press-fit peg and a tailored radius and contour to the sheep femoral condyle was placed at the most weight-bearing position. The level of the implant was aimed flush, 0,3 and 0,8 mm below surrounding cartilage. The animals were stabled indoors, allowed to move freely and euthanized after 6 and 12 weeks. Postoperatively the knees were high resolution photographed for macroscopic evaluation. The position and depth of the implant were analysed using a laser scan device. Tibial and femoral condyles specimen were decalcified and slices were prepared for microscopic evaluation. Implant position and cartilage damage was assessed from two independent observers using a macroscopic ICRS score and a modified histologic score according to Mankin. Results. 22 tibia condyles showed a variety of cartilage damage ranging from severe damage down to subchondral bone to an almost pristine condition. There was a strong correlation between implant position and damage to opposing cartilage surface. Mankin score correlated significantly with implant position (p<0.001 regression analysis, r. 2. =.45) as did the ICRS score (p<0.001, regression analysis, r. 2. =.67). Implants sitting proud were associated with poor Mankin score. There was no difference between 6-week and 3-months knees. Conclusion. By precise postoperative measurement we have shown that significant imprecision occur; this has never before been studied. We found a distinct correlation between implant position and cartilage damage. These results suggest that further studies of metallic implants, inserted into cartilage defects with the utmost precision regarding the surrounding cartilage, may be warranted


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 244 - 248
1 Feb 2016
Liu TJ Wang EB Dai Q Zhang LJ Li QW Zhao Q

Aims

The treatment of late presenting fractures of the lateral humeral condyle in children remains controversial.

Methods

We report on the outcome for 16 children who presented with a fracture of the lateral humeral epicondyle at a mean of 7.4 weeks (3 to 15.6) after injury and were treated surgically.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1165 - 1171
1 Sep 2013
Arastu MH Kokke MC Duffy PJ Korley REC Buckley RE

Coronal plane fractures of the posterior femoral condyle, also known as Hoffa fractures, are rare. Lateral fractures are three times more common than medial fractures, although the reason for this is not clear. The exact mechanism of injury is likely to be a vertical shear force on the posterior femoral condyle with varying degrees of knee flexion. These fractures are commonly associated with high-energy trauma and are a diagnostic and surgical challenge. Hoffa fractures are often associated with inter- or supracondylar distal femoral fractures and CT scans are useful in delineating the coronal shear component, which can easily be missed. There are few recommendations in the literature regarding the surgical approach and methods of fixation that may be used for this injury. Non-operative treatment has been associated with poor outcomes. The goals of treatment are anatomical reduction of the articular surface with rigid, stable fixation to allow early mobilisation in order to restore function. A surgical approach that allows access to the posterior aspect of the femoral condyle is described and the use of postero-anterior lag screws with or without an additional buttress plate for fixation of these difficult fractures.

Cite this article: Bone Joint J 2013;95-B:1165–71.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1126 - 1131
1 Aug 2016
Shiels SM Cobb RR Bedigrew KM Ritter G Kirk JF Kimbler A Finger Baker I Wenke JC

Aims

Demineralised bone matrix (DBM) is rarely used for the local delivery of prophylactic antibiotics. Our aim, in this study, was to show that a graft with a bioactive glass and DBM combination, which is currently available for clinical use, can be loaded with tobramycin and release levels of antibiotic greater than the minimum inhibitory concentration for Staphylococcus aureus without interfering with the bone healing properties of the graft, thus protecting the graft and surrounding tissues from infection.

Materials and Methods

Antibiotic was loaded into a graft and subsequently evaluated for drug elution kinetics and the inhibition of bacterial growth. A rat femoral condylar plug model was used to determine the effect of the graft, loaded with antibiotic, on bone healing.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1378 - 1384
1 Oct 2014
Weiser L Korecki MA Sellenschloh K Fensky F Püschel K Morlock MM Rueger JM Lehmann W

It is becoming increasingly common for a patient to have ipsilateral hip and knee replacements. The inter-prosthetic (IP) distance, the distance between the tips of hip and knee prostheses, has been thought to be associated with an increased risk of IP fracture. Small gap distances are generally assumed to act as stress risers, although there is no real biomechanical evidence to support this.

The purpose of this study was to evaluate the influence of IP distance, cortical thickness and bone mineral density on the likelihood of an IP femoral fracture.

A total of 18 human femur specimens were randomised into three groups by bone density and cortical thickness. For each group, a defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing the appropriate lengths of component. The maximum fracture strength was determined using a four-point bending test.

The fracture force of all three groups was similar (p = 0.498). There was a highly significant correlation between the cortical area and the fracture strength (r = 0.804, p <  0.001), whereas bone density showed no influence.

This study suggests that the IP distance has little influence on fracture strength in IP femoral fractures: the thickness of the cortex seems to be the decisive factor.

Cite this article: Bone Joint J 2014;96-B:1378–84.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1693 - 1697
1 Dec 2015
Keightley AJ Nawaz SZ Jacob JT Unnithan A Elliott DS Khaleel A

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110o and the median Iowa score was 85.

Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome.

High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator.

Cite this article: Bone Joint J 2015;97-B:1693–7.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 532 - 538
1 Apr 2015
Scott CEH Davidson E MacDonald DJ White TO Keating JF

Radiological evidence of post-traumatic osteoarthritis (PTOA) after fracture of the tibial plateau is common but end-stage arthritis which requires total knee arthroplasty is much rarer.

The aim of this study was to examine the indications for, and outcomes of, total knee arthroplasty after fracture of the tibial plateau and to compare this with an age and gender-matched cohort of TKAs carried out for primary osteoarthritis.

Between 1997 and 2011, 31 consecutive patients (23 women, eight men) with a mean age of 65 years (40 to 89) underwent TKA at a mean of 24 months (2 to 124) after a fracture of the tibial plateau. Of these, 24 had undergone ORIF and seven had been treated non-operatively. Patients were assessed pre-operatively and at 6, 12 and > 60 months using the Short Form-12, Oxford Knee Score and a patient satisfaction score.

Patients with instability or nonunion needed total knee arthroplasty earlier (14 and 13.3 months post-injury) than those with intra-articular malunion (50 months, p < 0.001). Primary cruciate-retaining implants were used in 27 (87%) patients. Complication rates were higher in the PTOA cohort and included wound complications (13% vs 1% p = 0.014) and persistent stiffness (10% vs 0%, p = 0.014). Two (6%) PTOA patients required revision total knee arthroplasty at 57 and 114 months. The mean Oxford knee score was worse pre-operatively in the cohort with primary osteoarthritis (18 vs 30, p < 0.001) but there were no significant differences in post-operative Oxford knee score or patient satisfaction (primary osteoarthritis 86%, PTOA 78%, p = 0.437).

Total knee arthroplasty undertaken after fracture of the tibial plateau has a higher rate of complications than that undertaken for primary osteoarthritis, but patient-reported outcomes and satisfaction are comparable.

Cite this article: Bone Joint J 2015;97-B:532–8.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).

Cite this article: Bone Joint J 2013;95-B:1406–9.