Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 75 - 75
1 Jan 2016
Nakamura S Sharma A Nakamura K Ikeda N Zingde S Komistek R Matsuda S
Full Access

Previously more femoral rollback has been reported in posterior-stabilized implants, but so far the kinematic change after post-cam engagement has been still unknown. The tri-condylar implants were developed to fit a life style requiring frequent deep flexion activities, which have the ball and socket third condyle as post-cam mechanism. The purpose of the current study was to examine the kinematic effects of the ball and socket third condyle during deep knee flexion. The tri-condylar implant analyzed in the current study is the Bi-Surface Knee System developed by Kyocera Medical (Osaka, Japan). Seventeen knees implanted with a tri-condylar implant were analyzed using 3D to 2D registration approach. Each patient was asked to perform a weight-bearing deep knee bend from full extension to maximum flexion under fluoroscopic surveillance. During this activity, individual fluoroscopic video frames were digitized at 10°increments of knee flexion. A distance of less than 1 mm initially was considered to signify the ball and socket contact. The translation rate as well as the amount of translation of medial and lateral AP contact points and the axial rotation was compared before and after the ball and socket joint contact. The average angle of ball and socket joint contact were 64.7° (SD = 8.7), in which no separation was observed after initial contact. The medial contact position stayed from full extension to ball and socket joint contact and then moved posteriorly with knee flexion. The lateral contact position showed posterior translation from full extension to ball and socket joint contact, and then greater posterior translation after contact (Figure 1). Translation and translation rate of contact positions were significantly greater at both condyles after ball and socket joint contact. The femoral component rotated externally from full extension to ball and socket joint contact, and then remained after ball and socket joint contact (Figure 2). There was no statistical significance in the angular rotation between ball and socket joint contact and maximum flexion. Translation of angular rotation was significantly greater before ball and socket joint contact, however, there was no significance in translation rate before and after ball and socket joint contact. The ball and socket joint was proved to induce posterior rollback intensively. In terms of axial rotation, the ball and socket joint did not induce reverse rotation, but had slightly negative effects after contact. The ball and socket provided enough functions as a posterior stabilizing post-cam mechanism and did not prevent axial rotation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 17 - 17
1 Jun 2012
Burnell C Brandt J Petrak M Bourne R
Full Access

Wear of the polyethylene (PE) insert in total knee replacements can lead to wear-particle and fluid-pressure induced osteolysis. One major factor affecting the wear behaviour of the PE insert in-vivo is the surface characteristics of the articulating femoral components. Contemporary femoral components available in Canada are either made of cast Cobalt Chromium (CoCr) alloy or have an oxidized zirconium surface (Oxinium). The latter type of femoral components have shown to have increased abrasive wear resistance and increased surface wettability, thus leading to reduced PE wear in-vitro compared with conventional cast CoCr components. Although surface damage has been reported on femoral components in general, there have been no reports in the literature as to what extent the recommended operating techniques affect the surface tribology of either type of femoral component. Twenty-two retrieved total knee replacements were identified with profound surface damage on the posterior aspect of the femoral condyles. The femoral components were of three different knee systems: five retrievals from the NexGen(r) total knee system (Zimmer Inc., Warsaw, IN), twelve retrievals from the Genesis II(r) total knee system (CoCr alloy or Oxinium; Smith & Nephew Inc., Memphis, TN), and five retrievals from the Duracon(r) total knee system (Stryker Inc., Mahwah, NJ). Reasons for revision were all non-wear-related and included aseptic loosening in two cases, painful flexion instability, and chronic infection. All retrieved femoral components showed evidence of surface damage on the condyles, at an average of 99° flexion (range, 43° – 135° flexion). Titanium (Ti) alloy transfer and abrasive surface damage were evident on all retrieved CoCr alloy femoral components that came in contact with Ti alloy tibial trays. Surface damage on the retrieved Oxinium femoral components was gouging, associated with the removal and cracking of the oxide and exposure of the zirconium alloy substrate material. CoCr alloy femoral components that had unintended contact with CoCr alloy tibial trays also showed evidence of gouging and abrasive wear. All femoral components showed severe surface damage in the posterior aspect of the condyles. The femoral surface was heavily scratched and the oxidized zirconium coating surface appeared removed. The surface analysis suggested that the surface damage most likely occurred during the time of initial implantation. In particular, it appeared that the femoral condyles were resting on the posterior aspect of the tibial tray in flexion, thus scratching the femoral components. Such scratches could potentially lead to accelerated PE insert wear and reduced implant longevity, thus making expensive revisions surgery necessary. The authors strongly suggest a revision of the current operating techniques recommended by the implant manufacturer to prevent this type of surface damage from occurring


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 124 - 124
1 Feb 2017
Li G Dimitriou D Tsai T Park K Kwon Y Freiberg A Rubash H
Full Access

Introduction. An equal knee joint height during flexion and extension is of critical importance in optimizing soft-tissue balancing following total knee arthroplasty (TKA). However, there is a paucity of data regarding the in-vivo knee joint height behavior. This study evaluated in-vivo heights and anterior-posterior (AP) translations of the medial and lateral femoral condyles before and after a cruciate-retaining (CR)-TKA using two flexion axes: surgical transepicondylar axis (sTEA) and geometric center axis (GCA). Methods. Eleven patient with advanced medial knee osteoarthritis (age: 51–73 years) who scheduled for a CR TKA and 9 knees from 8 healthy subjects (age: 23–49 years) were recruited. 3D models of the tibia and femur were created from their MR images. Dual fluoroscopic images of each knee were acquired during a weight-bearing single leg lunge. The OA knee was imaged again one year after surgery using the fluoroscopy during the same weight-bearing single leg lunge. The in vivo positions of the knee along the flexion path were determined using a 2D/3D matching technique. The GCA and sTEA were determined based on existing methods. Besides the anterior-posterior translation, the femoral condyle heights were determined using the distances from the medial and lateral epicondyle centers on the sTEA and GCA to the tibial plateau surface in coronal plane (Fig. 1). The paired t-test was applied to compare the medial and lateral condyle motion within each group (Healthy, OA, and CR-TKA). Two-way ANOVA followed post hoc Newman–Keuls test was adopted to detect significant differences among the groups. p<0.05 was considered significant. Results. The results demonstrated that following TKA, the medial and lateral femoral condyle heights were not equal at mid-flexion (15° to 45°, medial condyle lower then lateral by 2.4mm at least, p<0.01), although the knees were well-balanced at 0° and 90° (Fig. 2). While the femoral condyle heights increased from the pre-operative values (>2mm increase on average, p<0.05), they were similar to the intact knees except that the medial sTEA was lower than the intact medial condyle between 0 and 90°. At deep flexion (>90°), both condyles were significantly higher (>2mm, p <0.01) than the healthy knees. Anterior femoral translation of the TKA knee was more pronounce at mid-flexion (Fig. 3), whereas limited posterior translation was found at deep flexion. Conclusion. Femoral condyle heights and AP translations of the CR TKA knees were significantly different from the healthy knees during the weight bearing flexion activity when measured using both the sTEA and GCA, especially at mid-flexion (15° to 45°) and deep flexion (>90°). These results suggest that a well-balanced knee intra-operatively might not necessarily result in mid-flexion and deep flexion balance during functional weight-bearing motion, implying mid-flexion instability and deep flexion tightness of the knee. The data could be useful for improvement of future prostheses designs and surgical techniques in treatment of patients with end-stage medial knee OA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2022
Cheruvu MS Ganapathi M
Full Access

Abstract. Background. Conventional TKR aims for neutral mechanical alignment which may result in a smaller lateral distal femoral condyle resection than the implant thickness. We aim to explore the mismatch between implant thickness and bone resection using 3D planning software used for Patient Specific Instrumentation (PSI) TKR. Methods. This is a retrospective anatomical study from pre-operative MRI 3D models for PSI TKR. Cartilage mapping allowed us to recreate the native anatomy, enabling us to quantify the mismatch between the distal lateral femoral condyle resection and the implant thickness. Results. We modelled 292 knees from PSI TKR performed between 2012 and 2015. There were 225 varus knees and 67 valgus knees, with mean supine hip-knee-angle of 5.6±3.1 degrees and 3.6±4.6 degrees, respectively. In varus knees, the mean cartilage loss from medial and lateral femoral condyle was 2.3±0.7mm and 1.1±0.8mm respectively; the mean overstuffing of the lateral condyle 1.9±2.2mm. In valgus knees, the mean cartilage loss from medial and lateral condyle was 1.4±0.8mm and 1.5±0.9mm respectively; the mean overstuffing of the lateral condyle was 4.1±1.9mm. Conclusions. Neutral alignment TKR often results in overstuffing of the lateral condyle. This may increase the patello-femoral pressure at the lateral facet in flexion. Anterior knee pain may be persistent even after patellar resurfacing due to tight lateral retinacular structures. An alternative method of alignment such as anatomic alignment may minimise this problem


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 83 - 83
10 Feb 2023
Lee H Lewis D Balogh Z
Full Access

Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All extra-articular fractures and revision fixation cases were allowed to weight bear immediately. The primary outcome was union rate. This technique was utilised on sixteen patients; 3 acute, 13 revisions; mean age 52 years (range 16-85), 81% male, 5 open fractures. The union rate was 100%, with a median time to union of 29 weeks (IQR 18-46). The mean follow-up was 15 months. There were two complications: a deep infection requiring two debridements and a prominent screw requiring removal. The mean range of motion was 1–108. o. . Supplemental medial plating of DFF with a Large Fragment LCP T-Plate is a feasible, safe, and economical option for both acute fixation and revisions. Further validation on a larger scale is warranted, along with considerations to developing a specific implant in line with these principles


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 137 - 137
1 Feb 2020
Dessinger G Argenson J Bizzozero P LaCour M Komistek R
Full Access

Introduction. Numerous fluoroscopic studies have been conducted to investigate kinematic variabilities of total knee arthroplasty (TKA). In those studies, subjects having a posterior stabilized (PS) TKA experience greater weightbearing knee flexion and posterior femoral rollback of the lateral condyle. In those same studies, subjects did experience a high incidence of variable medial condyle motion and reverse axial rotation, especially occurring when the cam engaged the post. More recently, a PS TKA was designed to accommodate both gender and ethnicity. Therefore, the objective of this study was to assess in vivo kinematics for subjects having this TKA type to determine if subjects having this PS TKA experienced more optimal knee kinematics. Methods. Twenty-five subjects in this study were asked to perform a deep knee bend to maximum knee flexion and a step-up maneuver while under fluoroscopic surveillance. All subjects were patients of one experienced surgeon and received the same PS TKA. Using a 3D-2D registration technique, the CAD models, supplied by the sponsoring company, were superimposed over x-ray images at specified increments throughout the fluoroscopic footage. The kinematics were then analyzed to evaluate lateral anterior/posterior (LAP) and medial anterior/posterior (MAP) condyle translation as well as axial rotation of the femur with respect to the tibia. Results. During the DKB activity, the average flexion for the PS TKA subjects was 1108°. On average subjects experienced a lateral condyle motion in the posterior direction of 7.3mm, with the maximum amount of posterior rollback being 12.8 mm. These same subjects experienced an average medial condyle motion in the posterior direction of 4.8 mm with the maximum amount of posterior motion being 7.8 mm. Therefore, with the lateral condyle rolling more posterior than the medial condyle, these subjects experienced an average amount of 7.1° of axial rotation, with a maximum of 12.0°. Only one subject in this study experienced a reverse axial rotation from full extension to maximum knee flexion. During the step-up maneuver, subjects consistently experienced a roll forward motion of both their condyles. Discussion. Subjects in this study experienced a high incidence and magnitude of lateral condyle posterior femoral rollback, leading a normal-like axial rotation pattern, although less in magnitude compared to the normal knee. There was variability occurring with the medial condyle as some experience experienced an anterior slide while others rolled in the posterior direction. As seen in previous studies, during mid flexion both condyles experienced a more variable motion pattern. Twenty-five subjects having a posterior cruciate retaining TKA are being added to this study to determine if retention of the PCL in a similarly designed TKA leads to more normal-like kinematic patterns


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 83 - 83
1 Dec 2022
Bornes T Kubik J Klinger C Altintas B Dziadosz D Ricci W
Full Access

Tibial plateau fracture reduction involves restoration of alignment and articular congruity. Restorations of sagittal alignment (tibial slope) of medial and lateral condyles of the tibial plateau are independent of each other in the fracture setting. Limited independent assessment of medial and lateral tibial plateau sagittal alignment has been performed to date. Our objective was to characterize medial and lateral tibial slopes using fluoroscopy and to correlate X-ray and CT findings. Phase One: Eight cadaveric knees were mounted in extension. C-arm fluoroscopy was used to acquire an AP image and the C-arm was adjusted in the sagittal plane from 15° of cephalad tilt to 15 ° of caudad tilt with images captured at 0.5° increments. The “perfect AP” angle, defined as the angle that most accurately profiled the articular surface, was determined for medial and lateral condyles of each tibia by five surgeons. Given that it was agreed across surgeons that more than one angle provided an adequate profile of each compartment, a range of AP angles corresponding to adequate images was recorded. Phase Two: Perfect AP angles from Phase One were projected onto sagittal CT images in Horos software in the mid-medial compartment and mid-lateral compartment to determine the precise tangent subchondral anatomic structures seen on CT to serve as dominant bony landmarks in a protocol generated for calculating medial and lateral tibial slopes on CT. Phase Three: 46 additional cadaveric knees were imaged with CT. Tibial slopes were determined in all 54 specimens. Phase One: Based on the perfect AP angle on X-ray, the mean medial slope was 4.2°+/-2.6° posterior and mean lateral slope was 5.0°+/-3.8° posterior in eight knees. A range of AP angles was noted to adequately profile each compartment in all specimens and was noted to be wider in the lateral (3.9°+/-3.8°) than medial compartment (1.8°+/-0.7° p=0.002). Phase Two: In plateaus with a concave shape, the perfect AP angle on X-ray corresponded with a line between the superiormost edges of the anterior and posterior lips of the plateau on CT. In plateaus with a flat or convex shape, the perfect AP angle aligned with a tangent to the subchondral surface extending from center to posterior plateau on CT. Phase Three: Based on the CT protocol created in Phase Two, mean medial slope (5.2°+/-2.3° posterior) was significantly less than lateral slope (7.5°+/-3.0° posterior) in 54 knees (p<0.001). In individual specimens, the difference between medial and lateral slopes was variable, ranging from 6.8° more laterally to 3.1° more medially. In a paired comparison of right and left knees from the same cadaver, no differences were noted between sides (medial p=0.43; lateral p=0.62). On average there is slightly more tibial slope in the lateral plateau than medial plateau (2° greater). However, individual patients may have substantially more lateral slope (up to 6.8°) or even more medial slope (up to 3.1°). Since tibial slope was similar between contralateral limbs, evaluating slope on the uninjured side provides a template for sagittal plane reduction of tibial plateau fractures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 18 - 18
1 Jul 2020
Pattappa G Koch M Weber J Lang S Bohrer A Johnstone B Docheva D Zellner J Angele P Krueckel J Franke D
Full Access

Osteoarthritis (OA) is one of the most prevalent joint diseases involving progressive and degenerative changes to cartilage resulting from a variety of etiologies including post-traumatic incident or aging. OA lesions can be treated at its early stages through cell-based tissue engineering therapies using Mesenchymal Stem Cells (MSCs). In vivo models for evaluating these strategies, have described both chondral (impaction) and osteochondral (biopsy punch) defects. The aim of the investigation was to develop a compact and reproducible defect inducing post-traumatic degenerative changes mimicking early OA. Additionally, a pilot study to evaluate the efficacy of MSC-hydrogel treatment was also assessed. Surgery was performed on New Zealand white rabbits (male, 5–8 months old) with defects created on medial femoral condyle. For developing an appropriate defect, three approaches were used for evaluation: a biopsy punch (n = three at six and twelve weeks), an impaction device1 (n = three at six and twelve weeks) and a dental drill model (n = six at six and twelve weeks). At stated time points, condyles were harvested and decalcified in 10% EDTA, then embedded in Tissue-Tek and sectioned using a cryostat. Upon identification of region of interest, sections were stained with Safranin-O/Fast green and scored using OARSI scoring system by two blinded observers2. For the pilot study, autologous bone marrow was harvested from rabbits and used to isolate and expand MSCs. The Dental drill model was applied to both knee condyles, left untreated for six weeks at which stage, PKH26 fluorescently labelled MSCs were seeded into a hyaluronic acid hydrogel (TETEC). Repair tissue was removed from both condyles and MSC-hydrogel was injected into the left knee, whilst right knee was left empty. Rabbits were sacrificed at one (n = 1), six (n = 3) and twelve (n = 3) weeks post-treatment, processed as previously described and cartilage regeneration evaluated using Sellers score3. Impacted condyles exhibited no observed changes histologically (Mean OARSI score = 1 + 1), whereas biopsy punched and dental drilled defects demonstrated equal signs of cartilage erosion (OARSI score = 3 + 1) at assessed time points. However, biopsy punched condyles formed a diffusive defect, whereas dental drilled condyles showed a more defined, compact and reproducible defect. In the pilot study, PKH-labelled MSCs were observed at one and six weeks post-implantation within the defect space where hydrogel was injected. Tissue regeneration assessment indicated no difference between empty (Mean Sellers score = 14 + 2) and MSC treated defects (Sellers score = 16 + 5) at six weeks post-injection. At twelve weeks, MSC treated defects showed improved tissue regeneration with substantial subchondral bone restoration and good integration of regenerative cartilage with surrounding intact tissue (Sellers score = 10 + 1), whereas untreated defects showed no change in regeneration compared to six weeks (Sellers score = 16 + 2). Dental drill model was found to be the appropriate strategy for investigating early OA progression and treatment. Application of MSCs in defects showed good cartilage regeneration after twelve weeks application, indicating their promise in the treatment of early OA defects


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 68 - 68
1 Feb 2020
Gascoyne T Pejhan S Bohm E Wyss U
Full Access

Background. The anatomy of the human knee is very different than the tibiofemoral surface geometry of most modern total knee replacements (TKRs). Many TKRs are designed with simplified articulating surfaces that are mediolaterally symmetrical, resulting in non-natural patterns of motion of the knee joint [1]. Recent orthopaedic trends portray a shift away from basic tibiofemoral geometry towards designs which better replicate natural knee kinematics by adding constraint to the medial condyle and decreasing constraint on the lateral condyle [2]. A recent design concept has paired this theory with the concept of guided kinematic motion throughout the flexion range [3]. The purpose of this study was to validate the kinematic pattern of motion of the surface-guided knee concept through in vitro, mechanical testing. Methods. Prototypes of the surface-guided knee implant were manufactured using cobalt chromium alloy (femoral component) and ultra-high molecular weight polyethylene (tibial component). The prototypes were installed in a force-controlled knee wear simulator (AMTI, Watertown, MA) to assess kinematic behavior of the tibiofemoral articulation (Figure 1). Axial joint load and knee flexion experienced during lunging and squatting exercises were extracted from literature and used as the primary inputs for the test. Anteroposterior and internal-external rotation of the implant components were left unconstrained so as to be passively driven by the tibiofemoral surface geometry. One hundred cycles of each exercise were performed on the simulator at 0.33 Hz using diluted bovine calf serum as the articular surface lubricant. Component motion and reaction force outputs were collected from the knee simulator and compared against the kinematic targets of the design in order to validate the surface-guided knee concept. Results. Under deep flexion conditions of up to 140° of squatting the surface-guided knee implants were found to undergo a maximum of 22.2° of tibial internal rotation and 20.4 mm of posterior rollback on the lateral condyle. Pivoting of the knee joint was centered about the highly congruent medial condyle which experienced only 1.6 mm of posterior rollback. Experimental results were within 2° (internal-external rotation) and 1 mm (anteroposterior translation) agreement with the design target throughout the applied exercises (Figure 2). Conclusion. The results of this test confirm that by combining a constrained medial condyle with guiding geometry on the lateral condyle, deep knee flexion activities of up to 140° can be performed while maintaining near-natural kinematics of the knee joint. The authors believe that the tested surface-guided implant concept is a significant step toward the development of novel TKR which allows a greater range of motion and could improve the quality of life for active patients undergoing knee replacement. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 100 - 100
1 Feb 2020
Khasian M LaCour M Coomer S Komistek R
Full Access

Background. Although early TKA designs were symmetrical, during the past two decades TKA have been designed to include asymmetry, pertaining to either the trochlear groove, femoral condylar shapes or the tibial component. More recently, a new TKA was designed to include symmetry in all areas of the design, in the hopes of reducing design and inventory costs. Objective. The objective of this study was to determine the in vivo kinematics for subjects implanted with this symmetrical TKA during a weight-bearing deep knee bend activity. Methods. In vivo deep knee bend (DKB) kinematics for 21 subjects implanted with symmetrical posterior cruciate sacrificing (PCS) fixed bearing TKA were obtained using fluoroscopy. A 3D-to-2D registration technique was used to determine each subjects anteroposterior translation of lateral (LAP) and medial (MAP) femoral condyles and tibiofemoral axial rotation and their weight-bearing knee flexion. Results. During the DKB, the average maximum weight-bearing flexion was 111.7° ± 13.3°. On average, from full extension to maximum knee flexion, subjects experienced 2.5 mm ± 2.0 mm femoral rollback on lateral condyle −2.5 mm ± 2.2 mm of medial condyle motion in the anterior direction (Figure 1). This medial condyle motion was consistent for the majority of the subjects with the lateral condyle exhibiting rollback from 0° to 60° of flexion and then an average anterior slide of 0.3 mm from 60° to 90° of flexion. On average, the subjects in this study experienced 6.6° ± 3.3° of axial rotation, with most of rotation occurring in early flexion, averaging 4.9° (Figure 2). Discussion. Although subjects in this study were implanted with a symmetrical TKA, they did experience femoral rollback of the lateral condyle and positive axial rotation. Both of these kinematic parameters were normal-like in pattern, compared to the normal knee in early flexion, but in deeper flexion the pattern of motion varied from the normal knee. Also, the magnitude of posterior femoral rollback and axial rotation revealed similarities to previous fluoroscopy studies on subjects implanted with an asymmetrical TKA design. This was only a single surgeon study, so it is unclear if the results are TKA or surgeon influenced. Therefore, it is proposed that more patients be analyzed having this TKA implanted by other surgeons. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 89 - 89
7 Nov 2023
Greenwood K Molepo M Mogale N Keough N Hohmann E
Full Access

The posterior compartments of the knee are currently accessed arthroscopically through anterior, posteromedial or posterolateral portals. A direct posterior portal to access the posterior compartments has been overlooked due to a perceived high-risk of injury to the popliteal neurovascular structures. Therefore, this study aimed to investigate the safety and accessibility of a direct posterior portal into the knee. This cross-sectional study comprised a sample of 95 formalin-embalmed cadaveric knees and 9 fresh-frozen knees. Cannulas were inserted into the knees, 16mm from the vertical plane between the medial epicondyle of the femur and medial condyle of the tibia and 8 and 14mm (females and males respectively) from the vertical plane connecting the lateral femoral epicondyle and lateral tibial condyle. Landmarks were identified in full extension and cannula insertion was completed with the formalin-embalmed knees in full extension and the fresh-frozen in 90-degree flexion. Posterior aspects of the knees were dissected from superficial to deep, to assess potential damage caused by cannula insertion. Incidence of neurovascular damage was 9.6% (n=10); 0.96% medial cannula and 8.7% lateral cannula. The medial cannula damaged one small saphenous vein (SSV) in a male specimen. The lateral cannula damaged one SSV, 7 common fibular nerves (CFN) and both CFN and lateral cutaneous sural nerve in one specimen. All incidences of damage occurred in formalin-embalmed knees. The posterior horns of the menisci were accessible in all specimens. A medial-lying direct posterior portal into the knee is safe in 99% of occurrences. The lateral-lying direct posterior portal is of high risk to the CFN


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 48 - 48
1 Feb 2021
Khasian M LaCour M Dennis D Komistek R
Full Access

Introduction. A common goal of total knee arthroplasty (TKA) is to restore normal knee kinematics. While substantial data is available on TKA kinematics, information regarding non-implanted knee kinematics is less well studied especially in larger patient populations. The objectives of this study were to determine normal femorotibial kinematics in a large number of non-implanted knees and to investigate parameters that yield higher knee flexion with weight-bearing activities. Methods. Femorotibial kinematics of 104 non-implanted healthy subjects performing a deep knee bend (DKB) activity were analyzed using 3D to 2D fluoroscopy. The average age and BMI were 38.1±18.2 years and 25.2±4.6, respectively. Pearson correlation analysis was used to determine statistical correlations. Results. On average, subjects experienced 21.5±7.2 mm, 13.8±8.9 mm, and 27.1°±12.1° of lateral rollback, medial rollback, and external femorotibial axial rotation, respectively (Figure 1). Most rollback occurred in early flexion, with 10.2±6.4 mm and 5.3±6.3 mm of rollback for the lateral and medial condyles, respectively. While the lateral condyle consistently moved posteriorly, the medial condyle experienced 1.8±4.8 mm of anterior sliding between 90° to 120° of flexion. There was a positive correlation between higher weight-bearing flexion and lateral condylar rollback (r=0.5480, p<.0001) (Figure 2), medial condylar rollback (r=0.3188, p=0.001) (Figure 3), and external axial rotation (r=0.5505, p<.0001) (Figure 4). There was an inverse correlation between advancing age and knee flexion (r=-0.7358, p<.0001) as well as higher BMI and flexion (r=-0.3332, p=0.0007), indicating that multiple factors contribute to postoperative range-of-motion. Conclusion. This represents one of the largest studies on normal knee femorotibial kinematics in non-implanted healthy subjects. These results indicate that increased condylar rollback and external axial rotation correlate with increased weight-bearing knee flexion, while increased age and BMI yield decreased flexion. Therefore, in order to achieve higher weight-bearing flexion following TKA, normal-like kinematics such as high rollback and external axial rotation should be incorporated into TKA design. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 49 - 49
1 Jul 2020
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar MJ Turgeon T
Full Access

The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution. Supine RSA radiographs were obtained post-operatively and at 6-, 12-, and 24-months. Standing (weight-bearing) RSA radiographs were obtained at 12-months (n=45) and 24-months (n=48). All patients received the same knee design with a fixed, conventional PE insert of either a cruciate retaining or posterior stabilized design. Ethics approval for this study was obtained. In order to assess in vivo wear, a highly accurate 3-dimensional virtual model of each in vivo TKA was developed. Coordinate data from RSA radiographs (mbRSA v3.41, RSACore) were applied to digital implant models to reconstruct each patient's replaced knee joint in a virtual environment (Geomagic Studio, 3D Systems). Wear was assessed volumetrically (digital model overlap) on medial and lateral condyles separately, across each follow-up. Annual rate of wear was calculated for each patient as the slope of the linear best fit between wear and time-point. The influence of weight-bearing was assessed as the difference in annual wear rate between standing and supine exams. Age, BMI, and Oxford-12 knee improvement were measured against wear rates to determine correlations. Weight bearing wear measurement was most consistent and prevalent in the medial condyle with 35% negative wear rates for the lateral condyle. For the medial condyle, standing exams revealed higher mean wear rates at 1 and 2 years, supine, 16.3 mm3/yr (SD: 27.8) and 11.2 mm3/yr (SD: 18.5) versus standing, 51.3 mm3/yr (SD: 55.9) and 32.7 mm3/yr (SD: 31.7). The addition of weight-bearing increased the measured volume of wear for 78% of patients at 1 year (Avg: 32.4 mm3/yr) and 71% of patients at 2 years (Avg: 48.9 mm3/yr). There were no significant (95% CI) correlations between patient demographics and wear rates. Volumetric, weight-bearing wear measurement of TKR using model-based RSA determined an average of 33 mm3/yr at 2 years post-surgery for a modern, non-cross-linked polyethylene bearing. This value is comparable to wear rates obtained from retrieved TKRs. Weight-bearing exams produced better wear data with fewer negative wear rates and reduced variance. Limitations of this study include: supine patient imaging performed at post-op, no knee flexion performed, unknown patient activity level, and inability to distinguish wear from plastic creep or deformation under load. Strengths of this study include: large sample size of a single TKR system, linear regression of wear measurements and no requirement for implanted RSA beads with this method. Based on these results, in vivo volumetric wear of total knee replacement polyethylene can be reliably measured using model-based RSA and weight-bearing examinations in the short- to mid–term. Further work is needed to validate the accuracy of the measurements in vivo


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 100 - 100
10 Feb 2023
Mactier L Baker M Twiggs J Miles B Negus J
Full Access

A primary goal of revision Total Knee Arthroplasty (rTKA) is restoration of the Joint Line (JL) and Posterior Condylar Offsets (PCO). The presence of a native contralateral joint allows JL and PCO to be inferred in a way that could account for patient-specific anatomical variations more accurately than current techniques. This study assesses bilateral distal femoral symmetry in the context of defining targets for restoration of JL and PCO in rTKA. 566 pre-operative CTs for bilateral TKAs were segmented and landmarked by two engineers. Landmarks were taken on both femurs at the medial and lateral epicondyles, distal and posterior condyles and hip and femoral centres. These landmarks were used to calculate the distal and posterior offsets on the medial and lateral sides (MDO, MPO, LDO, LPO respectively), the lateral distal femoral angle (LDFA), TEA to PCA angle (TEAtoPCA) and anatomic to mechanical axis angle (AAtoMA). Mean bilateral differences in these measures were calculated and cases were categorised according to the amount of asymmetry. The database analysed included 54.9% (311) females with a mean population age of 68.8 (±7.8) years. The mean bilateral difference for each measure was: LDFA 1.4° (±1.0), TEAtoPCA 1.3° (±0.9), AAtoMA 0.5° (±0.5), MDO 1.4mm (±1.1), MPO 1.0mm (±0.8). The categorisation of asymmetry for each measure was: LDFA had 39.9% of cases with <1° bilateral difference and 92.4% with <3° bilateral difference, TEAtoPCA had 45.8% <1° and 96.6% <3°, AAtoMA had 85.7% <1° and 99.8% <3°, MDO had 46.2% <1mm and 90.3% <3mm, MPO had 57.0% <1mm and 97.9% <3mm. This study presents evidence supporting bilateral distal femoral symmetry. Using the contralateral anatomy to obtain estimates for JL and PCO in rTKA may result in improvements in intraoperative accuracy compared to current techniques and a more patient specific solution to operative planning


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 64 - 64
1 Apr 2019
Dessinger G Ta M Zeller I Nachtrab J Sharma A Komistek R
Full Access

Introduction. Many fluoroscopic studies on total knee arthroplasty (TKA) have identified kinematic variabilities compared to the normal knee, with many subjects experiencing paradoxical motion patterns. The intent of this research study was to investigate the results of customized-individual-made (CIM) and off-the-shelf (OTS) PS and PCR TKA to determine kinematic variabilities and to assess these kinematic patterns with those previously documented for the normal knee. Methods. In vivo kinematics were assessed for 151 subjects – 44 with CIM-PCR, 75 with OTS-PCR, 14 with CIM-PS, and 18 with OTS-PS TKA – using a mobile fluoroscopic system and then evaluated using a 3D-2D registration technique. This was a multicenter evaluation so the group of implants were implanted by two surgeons and selected based on recruitment criteria. Each subject performed a deep knee bend activity (DKB) while under fluoroscopy. The kinematics assessed for each subject were condyle translation (LAP/MAP) and rotation (axial rotation). Results. During the DKB, the average LAP of the CIM-PCR was −2.0 mm (s = 4.0), the OTS-PCR was −2.1 mm (s = 3.0), the CIM-PS was −9.0 mm (s = 6.0), and the OTS-PS was −4.3 mm (s = 3.3) (Figure 1). The average MAP of the CIM-PCR was 2.0 mm (s = 2.9), the OTS-PCR was 2.4 mm (s = 3.3), the CIM-PS was −1.2 mm (s = 5.2), and the OTS-PS was 1.1 mm (s = 1.7) (Figure 2). The average axial rotation of the CIM-PCR was 4.6° (s = 5.8), the OTS-PCR was 5.7° (s = 4.8), the CIM-PS was 9.3° (s = 4.8), and the OTS-PS was 7.5° (s = 3.5) (Figure 3). Eleven of 44 (25%) subjects having a CIM-PCR TKA, 16/75 (21.3%) subjects having an OTS-PCR TKA experienced an anterior slide of their lateral condyle, while no subjects having a CIM-PS TKA and 3/18 (16.6%) of OTS-PS subjects experienced this slide. Nine of 44 (20.5%) CIM- PCR, 8/75 (10.6%) OTS-PCR experienced a reverse axial rotation pattern, while only one subject having a CIM-PS and not OTS-PS subjects experienced this non-normal rotation pattern. Discussion. Subjects having a CIM-PS TKA experienced the greatest amount of lateral condyle posterior femoral rollback and axial rotation, although less in magnitude to the normal knee seen in previous fluoroscopic studies. This was the only group to experience posterior motion of their medial condyle during flexion. More subjects having a PCR TKA experienced a paradoxical anterior lateral condyle sliding pattern and reverse axial rotation pattern, which was not commonly seen in the subjects having a PS TKA. Significance. Subjects that had a CIM-PS TKA demonstrated greater magnitudes of lateral condyle rollback and subjects having a PS TKA experienced more normal axial rotation patterns


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 73 - 73
1 Feb 2020
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar M Turgeon T
Full Access

Purpose. The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Methods. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution. Supine RSA radiographs were obtained post-operatively and at 6-, 12-, and 24-months. Standing (weight-bearing) RSA radiographs were obtained at 12-months (n=45) and 24-months (n=48). All patients received the same knee design with a fixed, conventional PE insert of either a cruciate retaining or posterior stabilized design. Ethics approval for this study was obtained. In order to assess in vivo wear, a highly accurate 3-dimensional virtual model of each in vivoTKA was developed. Coordinate data from RSA radiographs (mbRSA v3.41, RSACore) were applied to digital implant models to reconstruct each patient's replaced knee joint in a virtual environment (Geomagic Studio, 3D Systems). Wear was assessed volumetrically (digital model overlap) on medial and lateral condyles separately, across each follow-up. Annual rate of wear was calculated for each patient as the slope of the linear best fit between wear and time-point. The influence of weight-bearing was assessed as the difference in annual wear rate between standing and supine exams. Age, BMI, and Oxford-12 knee improvement were measured against wear rates to determine correlations. Results. Weight bearing wear measurement was most consistent and prevalent in the medial condyle with 0–4% of calculated wear rates being negative compared to 29–39% negative wear rates for the lateral condyle. For the medial condyle, standing exams revealed higher mean wear rates at 1 and 2 years; supine, 16.3 mm. 3. /yr (SD: 27.8) and 11.2 mm. 3. /yr (SD: 18.5) versus standing, 51.3 mm. 3. /yr (SD: 55.9) and 32.7 mm. 3. /yr (SD: 31.7). The addition of weight-bearing increased the measured volume of wear for 78% of patients at 1 year (Avg: 32.4 mm. 3. /yr) and 71% of patients at 2 years (Avg: 48.9 mm. 3. /yr). There were no significant (95% CI) correlations between patient demographics and wear rates. Discussion and Conclusion. This study demonstrated TKA wear to occur at a rate of approximately 10 mm. 3. /year and 39 mm. 3. /year in patients imaged supine versus standing, respectively, averaged over 2 years of clinical follow-up. In an effort to eliminate the effect of PE creep and deformation, wear was also calculated between 12 and 24 months as 9.3 mm. 3. (standing examinations), This value is comparable to wear rates obtained from retrieved TKRs. Weight-bearing exams produced better wear data with fewer negative wear rates and reduced variance. Limitations of this study include: supine patient imaging performed at post-op, no knee flexion performed, and unknown patient activity level. Strengths of this study include: large sample size of a single TKR system, linear regression of wear measurements and no requirement for implanted RSA beads with this method. Based on these results, in vivo volumetric wear of total knee replacement polyethylene can be reliably measured using model-based RSA and weight-bearing examinations in the short- to mid–term. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 75 - 75
1 Dec 2022
Rousseau-Saine A Kerslake S Hiemstra LA
Full Access

Recurrent patellar instability is a common problem and there are multiple demographic and pathoanatomic risk factors that predispose patients to dislocating their patella. The most common of these is trochlear dysplasia. In cases of severe trochlear dysplasia associated with patellar instability, a sulcus deepening trochleoplasty combined with a medial patellofemoral ligament reconstruction (MPFLR) may be indicated. Unaddressed trochlear pathology has been associated with failure and poor post-operative outcomes after stabilization. The purpose of this study is to report the clinical outcome of patients having undergone a trochleoplasty and MPFLR for recurrent lateral patellofemoral instability in the setting of high-grade trochlear dysplasia at a mean of 2 years follow-up. A prospectively collected database was used to identify 46 patients (14 bilateral) who underwent a combined primary MPFLR and trochleoplasty for recurrent patellar instability with high-grade trochlear dysplasia between August 2013 and July 2021. A single surgeon performed a thin flap trochleoplasty using a lateral para-patellar approach with lateral retinaculum lengthening in all 60 cases. A tibial tubercle osteotomy (TTO) was performed concomitantly in seven knees (11.7%) and the MPFLR was performed with a gracilis tendon autograft in 22%, an allograft tendon in 27% and a quadriceps tendon autograft in 57% of cases. Patients were assessed post-operatively at three weeks and three, six, 12 and 24 months. The primary outcome was the Banff Patellar Instability Instrument 2.0 (BPII 2.0) and secondary outcomes were incidence of recurrent instability, complications and reoperations. The mean age was 22.2 years (range, 13 to 45), 76.7% of patients were female, the mean BMI was 25.03 and the prevalence of a positive Beighton score (>4/9) was 40%. The mean follow-up was 24.3 (range, 6 to 67.7) months and only one patient was lost to follow-up before one year post-operatively. The BPII 2.0 improved significantly from a mean of 27.3 pre-operatively to 61.1 at six months (p < 0 .01) and further slight improvement to a mean of 62.1 at 12 months and 65.6 at 24 months post-operatively. Only one patient (1.6%) experienced a single event of subluxation without frank dislocation at nine months. There were three reoperations (5%): one for removal of the TTO screws and prominent chondral nail, one for second-look arthroscopy for persistent J-sign and one for mechanical symptoms associated with overgrowth of a lateral condyle cartilage repair with a bioscaffold. There were no other complications. In this patient cohort, combined MPFLR and trochleoplasty for recurrent patellar instability with severe trochlear dysplasia led to significant improvement of patient reported outcome scores and no recurrence of patellar dislocation at a mean of 2 years. Furthermore, in this series the procedure demonstrated a low rate (5%) of complications and reoperations


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 24 - 24
1 Apr 2018
Zeller I Grieco T Meccia B Sharma A Komistek R
Full Access

Background. The overall goal of total knee arthroplasty (TKA) is to facilitate the restoration of native function following late stage osteoarthritis and for this reason it is important to develop a thorough understanding of the mechanics of a normal healthy knee. While there are several methods for assessing TKA mechanics, these methods have limitations that make them prohibitive to both replicating physiological systems and evaluating non-implanted knees. These limitations can be circumvented through the development of mathematical models that use anatomical and physiological inputs to computationally simulate joint mechanics. This can be done in an inverse or forward manner to solve for either joint forces or motions respectively. The purpose of this study is to evaluate one such forward model and determine the accuracy of the predicted motions using fluoroscopy. Methods. In vivo kinematics were determined during flexion from full extension to 120 degrees for ten normal, healthy, subjects using fluoroscopy and a 3D-to-2D registration method. All ten subjects had previously undergone CT scans allowing for the digital reconstruction of native femur and tibia geometries. These geometries were then input into a ridged body forward model based on Kane's system of dynamics. The resulting kinematics determined through fluoroscopy and the mathematical model were compared for all of the ten subjects. Results. The three kinematic parameters evaluated for this study were the initial positioning and translation of the medial and lateral condylar contact point in addition to the axial position and rotation of the femur with respect to the tibia. The model simulations demonstrated an average of −2.16mm of medial condyle translation, −14.03mm of lateral condyle translation, and 20.09°of axial rotation. Through fluoroscopy, subjects demonstrated an average of −3.63mm of medial condyle translation, −16.02mm of lateral condyle translation, and 15.65°of axial rotation. Comparing these two methods the model predicted on average an additional 1.47mm of medial condyle translation, 1.98mm of lateral condyle translation, and 4.44° less axial rotation compared to the fluoroscopic analysis of the same ten subjects. Conclusion. In comparing the simulation kinematics to the that of the fluoroscopic assessment, the results are comparably similar demonstrating a forward model can be a viable assessment of knee kinematics in the future. By validating mathematical simulation as a feasible means of mechanical assessment, it becomes possible to evaluate mechanics using inputs to reflect extraordinary and theoretical instances such as trauma patients and congenital deformities unable to be assessed by other methods. The nature of the model also allows for a seamless transition to assess TKA mechanics, creating a more efficient means of evaluating both device design and surgical technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 57 - 57
1 Dec 2022
Champagne A McGuire A Shearer K Brien D Martineau PA Bardana DD
Full Access

Reconstruction of the anterior cruciate ligament (ACL) allows to restore stability of the knee, in order to facilitate the return to activity (RTA). Although it is understood that the tendon autograft undergoes a ligamentous transformation postoperatively, knowledge about longitudinal microstructural differences in tissue integrity between types of tendon autografts (ie, hamstring vs. patella) remains limited. Diffusion tensor imaging (DTI) has emerged as an objective biomarker to characterize the ligamentization process of the tendon autograft following surgical reconstruction. One major limitation to its use is the need for a pre-injury baseline MRI to compare recovery of the graft, and inform RTA. Here, we explore the relationship for DTI biomarkers (fractional anisotropy, FA) between knees bilaterally, in healthy participants, with the hypothesis that agreement within a patient's knees may support the use of the contralateral knee as a reference to monitor recovery of the tendon autograft, and inform RTA. Fifteen participants with no previous history of knee injuries were enrolled in this study (age, 26.7 +/− 4.4 years; M/F, 7/8). All images were acquired on a 3T Prisma Siemens scanner using a secured flexible 18-channel coil wrapped around the knee. Both knees were scanned. A 3D anatomical Double Echo Steady State (DESS) sequence was acquired on which regions of interest (ROI) were placed consistent with the footprints of the ACL (femur, posteromedial corner on medial aspect of lateral condyle; tibia, anteromedial to intercondylar eminence). Diffusion images were acquired using fat saturation based on optimized parameters in-house. All diffusion images were pre-processed using the FMRIB FSL toolbox. The footprint ROIs of the ACL were then used to reconstruct the ligament in each patient with fiber-based probabilistic tractography (FBPT), providing a semi-automated approach for segmentation. Average FA was computed for each subject, in both knees, and then correlated against one another using a Pearson correlation to assess the degree of similarity between the ACLs. A total of 30 datasets were collected for this study (1/knee/participant; N=15). The group averaged FA (+/− standard deviation) for the FBPT segmented ACLs were found to equal 0.1683 +/− 0.0235 (dominant leg) and 0.1666 +/− 0.0225 (non-dominant leg). When comparing both knees within subjects, reliable agreement was found for the FBPT-derived ACL with a linear correlation coefficient (rho) equal to 0.87 (P < 0 .001). We sought to assess the degree of concordance in FA between the knees of healthy participants with hopes to provide a method for using the contralateral “healthy” knee in the comparison of autograft-dependent longitudinal changes in microstructural integrity, following ACL reconstruction. Our results suggest that good agreement in anisotropy can be achieved between the non-dominant and dominant knees using DTI and the FBPT segmentation method. Contralateral anisotropy of the ACL, assuming no previous injuries, may be used as a quantitative reference biomarker for monitoring the recovery of the tendon autograft following surgical reconstruction, and gather further insight as to potential differences between chosen autografts. Clinically, this may also serve as an index to supplement decision-making with respect to RTA, and reduce rates of re-injuries


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 10 - 10
1 Feb 2020
Vendittoli P Blakeney W Puliero B Beaulieu Y Kiss M
Full Access

INTRODUCTION. Mechanical alignment in TKA introduces significant anatomic modifications for many individuals, which may result in unequal medial-lateral or flexion-extension bone resections. The objective of this study was to calculate bone resection thicknesses and resulting gap sizes, simulating a measured resection mechanical alignment technique for TKA. METHODS. Measured resection mechanical alignment bone resections were simulated on 1000 consecutive lower limb CT-Scans from patients undergoing TKA. Bone resections were simulated to reproduce the following measured resection mechanical alignment surgical technique. The distal femoral and proximal tibial cuts were perpendicular to the mechanical axis, setting the resection depth at 8mm from the most distal femoral condyle and from the most proximal tibial plateau (Figure 1). If the resection of the contralateral side was <0mm, the resection level was increased such that the minimum resection was 0mm. An 8mm resection thickness was based on an implant size of 10mm (bone +2mm of cartilage). Femoral rotation was aligned with either the trans-epicondylar axis or with 3 degrees of external rotation to the posterior condyles. After simulation of the bone cuts, media-lateral gap difference and flexion-extension gaps difference were calculated. The gap sizes were calculated as the sum of the femoral and tibial bone resections, with a target bone resection of 16mm (+ cartilage corresponding to the implant thickness). RESULTS. For both the varus and valgus knees, the created gaps in the medial and lateral compartments were reduced in the vast majority of cases (<16mm). The insufficient lateral condyle resection distalises the lateral joint surface by a mean of 2.1mm for the varus and 4.4mm for the valgus knees. The insufficient medial tibial plateau resection proximalises the medial joint surface by 3.3mm for the varus and 1.2mm for the valgus knees. Medio-lateral gap imbalances in the extension space of more than 2mm) occurred in 25% of varus and 54% of valgus knees and significant imbalances of more than 5mm were present in up to 8% of varus and 19% of valgus knees. Higher medio-lateral gap imbalances in the flexion space were created with trans epicondylar axis versus 3 degrees to the posterior condyles (p<0.001). Using trans epicondylar axis, only 49% of varus and 18% of valgus knees had less than 3mm of imbalance in both media-lateral and flexion-extension gaps together. DISCUSSION AND CONCLUSION. A systematic use of the tested measured resection mechanical alignment technique for TKA leads to many cases with medio-lateral or flexion-extension gap asymmetries. Some medio-lateral imbalances may not be correctable surgically and may results in TKA instability. Other versions of the mechanical alignment technique or other alignment methods that better reproduce knee anatomies should be explored. For any figures or tables, please contact the authors directly