Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 10 - 10
1 Oct 2021
Zein A Elhalawany AS Ali M Cousins G
Full Access

Despite multiple published reviews, the optimum method of correction and stabilisation of Blount's disease remains controversial. The purpose of this study is to evaluate the clinical and radiological outcomes of acute correction of late-onset tibial vara by percutaneous proximal tibial osteotomy with circular external fixation using two simple rings. This technique was developed to minimise cost in a context of limited resources. This study was conducted between 2016 and 2020. We retrospectively reviewed the clinical notes and radiographs of 30 patients (32tibiae) who had correction of late-onset tibia by proximal tibial osteotomy and Ilizarov external fixator. All cases were followed up to 2 years. The mean proximal tibial angle was 65.7° (±7.8) preoperatively and 89.8° (±1.7) postoperatively. The mean mechanical axis deviation improved from 56.2 (±8.3) preoperatively to 2.8 (±1.6) mm postoperatively. The mean femoral-tibial shaft angle was changed from – 34.3° (±6.7) preoperatively to 5.7° (±2.8) after correction. Complications included overcorrection (9%) and pin tract infection (25%). At final follow up, all patients had full knee range of motion and normal function. All cases progressed to union and there were no cases of recurrence of deformity. This simple procedure provides secure fixation allowing early weight bearing and early return to function. It can be used in the context of health care systems with limited resources. It has a relatively low complication rate. Our results suggest that acute correction and simple circular frame fixation is an excellent treatment choice for cases of late-onset tibia vara, especially in severe deformities


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 687 - 692
1 May 2010
Giotakis N Panchani SK Narayan B Larkin JJ Al Maskari S Nayagam S

We have carried out a retrospective review of 20 patients with segmental fractures of the tibia who had been treated by circular external fixation. We describe the heterogeneity of these fractures, their association with multiple injuries and the need for multilevel stability with the least compromise of the biology of the fracture segments. The assessment of outcome included union, complications, the measurement of the functional IOWA knee and ankle scores and the general health status (Short-form 36). The mean time to union was 21.7 weeks (12.8 to 31), with no difference being observed between proximal and distal levels of fracture. Complications were encountered in four patients. Two had nonunion at the distal level, one a wire-related infection which required further surgery and another shortening of 15 mm with 8° of valgus which was clinically insignificant. The functional scores for the knee and ankle were good to excellent, but the physical component score of the short-form 36 was lower than the population norm. This may be explained by the presence of multiple injuries affecting the overall score


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 16 - 16
1 Jun 2017
Giannoudis V Ewins E Foster P Taylor M Harwood P
Full Access

Introduction. Distal tibial fractures are notoriously difficult to treat and a lack of consensus remains on the best approach. This study examined clinical and functional outcomes in such patients treated definitively by circular external fixation (Ilizarov). Patients and Methods: Between July 2011 and May 2016, patients with fractures extending to within 1 muller square of the ankle were identified from our prospective Ilizarov database. Existing data was supplemented by review of clinical records. Fractures were classified according to the AO/OTA classification. Functional outcome data, including general measures of health related quality of life (SF-12 and Euroqol) and limb specific scores (Olerud and Molander Score and Lysholm scores) had been routinely collected for part of the study period. Patients in whom this had not been collected were asked to complete these by post. Adverse events were documented according to Paley's classification of: problems, obstacles and complications. Results. 142 patients with 143 fractures were identified, 40 (28%) were open, 94 (66%) were intra-articular, 85 (59%) were tertiary referrals. 32% were type 1, 28%, type 2 and 40% type 3 AO/OTA severity. 139 (97%) of the fractures united (2 non-unions, 1 amputation and 2 delayed unions who remain in frames), at a median of 165 days (range 104 to 429, IQR 136 to 201). 62% united by 6 months, 87% by 9 months and 94% by 1 year. Both non-unions have united with further treatment. Closed fractures united more rapidly than open (median 157 vs 185 days; p=0.003) and true Pilon (43C3) fractures took longer to unite other fractures (median 156 vs 190 days; p<0.001). 34% of patients encountered a problem, 12% an obstacle and 10% a complication. Of the complications, 6 (4%) were minor, 5 (3.5%) major not interfering with the goals of treatment and 4 (3%) major interfering with treatment goals (including the 2 patients with non-union and 1 who underwent amputation as well as 1 significant mal-union). This will increase to 4% if the 2 delayed unions fail to unite. Overall 56% reported good or excellent ankle scores at last report, 28% fair and 16% poor. Closed, extra-articular and non-43C3 fractures had better functional outcome scores than open, intra-articular and 43C3 fractures respectively. Conclusions. This study demonstrates a high union and low serious complication rate, suggesting that external ring fixation is a safe and effective treatment for these injuries. *Judged best paper*


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims. In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia. Patients and Methods. Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study. Results. The regenerate mineralization on radiographs was comparable in both groups at two, four, six, and ten months’ follow-up but the rail fixator group had statistically significant higher grades of mineralization when compared with the circular frame group at eight and 12 months’ follow-up. The regenerate mineralization was also higher in the rail fixator group than in the circular frame group on CT at three and six months, although this difference was not statistically significant. Conclusion. Overall, the regenerate mineralization was higher in the monolateral than the circular frame group. A monolateral fixator may be preferred in patients with infected nonunion of the tibia with bone defects up to 7 cm. Cite this article: Bone Joint J 2019;101-B:1416–1422


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 710 - 717
1 Sep 1996
Dendrinos GK Kontos S Katsenis D Dalas A

We treated 24 patients with high-energy fractures of the tibial plateau by the Ilizarov fixator and transfixion wires. Eleven fractures were open, and 20 patients had complex injuries. Twelve were treated by ligamentotaxis and percutaneous fixation, seven by limited open reduction and five by extensive open reduction. All were followed for at least 24 months. All the fractures united, with an average time to healing of 14.4 weeks. Thirteen patients achieved full extension and 13 more than 110° of flexion. Twenty-two knees were stable. Fifteen patients walked normally and the rest with only a slight limp. All but two knees had an articular step-off of less than 4 mm and all had normal axial alignment except two. There were no cases of postoperative skin infection, osteomyelitis or septic arthritis. Ilizarov circular fixation is an ideal method of treatment for these fractures when extensive dissection and internal fixation are contraindicated due to trauma to the soft tissue, deficiency of bone stock, and bony comminution


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 17 - 17
1 May 2018
Kontoghiorghe C Khaleel A
Full Access

Background. The circular Ilizarov frame is a well-established method of external fixation used in the acute treatment of fractures. In our unit, based on our experience, we have changed practice from an all-wire construct to a hybrid, incorporating one 5mm titanium half-pin in the distal reference construct. We were able to compare the all-wire construct against this hybrid in terms of time to union and complications. Methods. All patients who underwent circular frame fixation between 2009 and 2016 for Schatzker IV-VI tibial plateau fractures at one district general hospital were included in the study. The date of union was noted and time to union was calculated. Results. A total of 151 patients were identified for the study. Of these, 17 were excluded due to loss to follow up. In total, 134 patients were included, 74 in the all-wire group and 60 in the hybrid group. Mean time to union was 155.5 days and 114.3 days respectively (p<0.01). Time spent in frame was therefore shorter in the hybrid group. There was no incidence of deep infection in either group and rates of superficial infection were comparable amongst both groups. Previously published data shows there is no difference between the groups in functional scores and SF scores. Conclusions. These results suggest that the hybrid method of Ilizarov fixation is superior to the classical all-wire method. Use of the hybrid construct will reduce time to union, thus improve patient tolerance and reduce associated complications


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 30 - 30
1 May 2018
Sadekar V Moulder E Hadland Y Barron E Sharma H
Full Access

Introduction. Fracture and deformity after frame removal is a known risk in 9–14.5% of patients after circular frame treatment. The aims of this study were to assess the effectiveness of our staged protocol for frame removal and risk factors for the protocol failure. Methods and materials. We identified 299 consecutive patients who underwent circular frame fixation for fracture or deformity correction in our unit from our prospective database. All 247 patients who followed the staged frame removal protocol were included in this study. We reviewed the electronic clinical record and radiographs of each patient to record demographics, risk factors for treatment failure and outcome following frame removal. We defined failure of the protocol as a re-fracture or change in bony alignment within 12 weeks of frame removal. Results underwent statistical analysis using Chi square analysis. Results. Of the 247 patients, 196 were trauma patients, of which 56 were open fractures and 48 were elective cases. There were 92 Ilizarov frames and 155 hexapods. 93 patients were smokers. The protocol failed to prevent mechanical failure after frame removal in 10 patients, of which four had refracture and six had an increase in deformity. The average increase in deformity was 7.7 in the frontal plane and 3.8 in the lateral plane. We identified risk factors for mechanical failure in eight of the ten; four were smokers, two were on steroids and two had hypophosphataemic rickets. Of the ten patients, four were for elective indications, six for trauma. Two of the six trauma patients had been treated for open fractures. ‘The type of frame and smoking history showed no statistical association with mechanical failure. Four patients went to have another frame, five were managed with plaster and one patient refused further treatment. Conclusion. Our staged reloading protocol may delay frame removal however it is a simple and effective way to confirm the timing of frame removal


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 10 - 10
1 Jun 2017
Noblet T Jackson P Foster P Taylor D Harwood P Wiper J
Full Access

Introduction. Large numbers of patients with open tibial fractures are treated in our major trauma centre. Previously, immediate definitive skeletal stabilisation and soft tissue coverage has been recommended in the management of such injuries. We describe our recent practice, focusing on soft tissue cover, including patients treated by early soft tissue cover and delayed definitive skeletal stabilisation. Methods. Between September 2012 and January 2016, more than 120 patients with open tibial fractures were admitted to our unit. Patients were identified through prospective databases. Data collected included patient demographics, injury details, orthopaedic and plastic surgery procedures. Major complications were recorded. Paediatric cases were excluded and one patient was lost to follow up. Results. Fifty-seven patients (median age 41 years (range 16–95)) were identified with open tibial fractures classified grade IIIB or IIIC requiring soft tissue coverage. Of these 57 patients, 39 were treated by initial temporary external fixation, soft tissue cover, and circular frame and 18 by initial temporary external fixation, soft tissue cover and internal fixation (ORIF). Of the 57 patients, 51 were acutely managed by Leeds MTC, and 6 were tertiary referrals primarily managed elsewhere. Soft tissue cover constituted free tissue transfer in 43 patients (19 gracilis, 15 ALT, 6 LD, 2 radial forearm and 1 groin flap), pedicled flap in 12 patients (6 gastroc, 4 fasciocutaneous, 1 soleus, 1 EDB), and skin graft in 2 patients. Complications included flap failure (n=3), return to theatre (n=1). Long term soft tissue cover was definitely achieved in 100% of cases. Chronic deep infection was reported in 1 acutely managed case. There were no cases of soft tissue failure after delayed circular frame fixation following soft tissue reconstruction. Conclusions. Evolution of orthopaedic techniques has meant that the management of these complex fractures using delayed definitive fixation with a circular frame is increasingly commonplace. This case series demonstrates that a joint orthoplastic approach, with circular frame application undertaken a short time after soft tissue reconstruction (including free flap surgery) is safe and can be undertaken without risk to the soft tissue coverage


Bone & Joint Open
Vol. 1, Issue 8 | Pages 481 - 487
11 Aug 2020
Garner MR Warner SJ Heiner JA Kim YT Agel J

Aims

To compare results of institutional preferences with regard to treatment of soft tissues in the setting of open tibial shaft fractures.

Methods

We present a retrospective review of open tibial shaft fractures at two high-volume level 1 trauma centres with differing practices with regard to the acute management of soft tissues. Site 1 attempts acute primary closure, while site 2 prefers delayed closure/coverage. Comparisons include percentage of primary closure, number of surgical procedures until definitive closure, percentage requiring soft tissue coverage, and percentage of 90-day wound complication.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 101 - 105
1 Jan 2013
Penn-Barwell JG Bennett PM Fries CA Kendrew JM Midwinter MJ Rickard RF

The aim of this study was to report the pattern of severe open diaphyseal tibial fractures sustained by military personnel, and their orthopaedic–plastic surgical management.The United Kingdom Military Trauma Registry was searched for all such fractures sustained between 2006 and 2010. Data were gathered on demographics, injury, management and preliminary outcome, with 49 patients with 57 severe open tibial fractures identified for in-depth study. The median total number of orthopaedic and plastic surgical procedures per limb was three (2 to 8). Follow-up for 12 months was complete in 52 tibiae (91%), and half the fractures (n = 26) either had united or in the opinion of the treating surgeon were progressing towards union. The relationship between healing without further intervention was examined for multiple variables. Neither the New Injury Severity Score, the method of internal fixation, the requirement for vascularised soft-tissue cover nor the degree of bone loss was associated with poor bony healing. Infection occurred in 12 of 52 tibiae (23%) and was associated with poor bony healing (p = 0.008). This series characterises the complex orthopaedic–plastic surgical management of severe open tibial fractures sustained in combat and defines the importance of aggressive prevention of infection.

Cite this article: Bone Joint J 2013;95-B:101–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 232 - 237
1 Feb 2006
Saridis A Panagiotopoulos E Tyllianakis M Matzaroglou C Vandoros N Lambiris E

We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight.

The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation.