Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 33 - 33
2 Jan 2024
Emonde C Reulbach M Evers P Behnsen H Nürnberger F Jakubowitz E Windhagen H
Full Access

According to the latest report from the German Arthroplasty Registry, aseptic loosening is the primary cause of implant failure following primary hip arthroplasty. Osteolysis of the proximal femur due to the stress-shielding of the bone by the implant causes loss of fixation of the proximal femoral stem, while the distal stem remains fixed. Removing a fixed stem is a challenging process. Current removal methods rely on manual tools such as chisels, burrs, osteotomes, drills and mills, which pose the risk of bone fracture and cortical perforation. Others such as ultrasound and laser, generate temperatures that could cause thermal injury to the surrounding tissues and bone. It is crucial to develop techniques that preserve the host bone, as its quality after implant removal affects the outcome of a revision surgery. A gentler removal method based on the transcutaneous heating of the implant by induction is proposed. By reaching the glass transition temperature (T. G. ) of the periprosthetic cement, the cement is expected to soften, enabling the implant to be gently pulled out. The in-vivo environment comprises body fluids and elevated temperatures, which deteriorate the inherent mechanical properties of bone cement, including its T. G. We aimed to investigate the effect of fluid absorption on the T. G. (ASTM E2716-09) and Vicat softening temperature (VST) (ISO 306) of Palacos R cement (Heraeus Medical GmbH) when dry and after storage in Ringer's solution for up to 8 weeks. Samples stored in Ringer's solution exhibited lower T. G. and VST than those stored in air. After 8 weeks, the T. G. decreased from 95.2°C to 81.5°C in the Ringer's group, while the VST decreased from 104.4°C to 91.9°C. These findings will be useful in the ultimate goal of this project which is to design an induction-based system for implant removal. Acknowledgements: Funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) – SFB/TRR-298-SIIRI – Project-ID 426335750


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 64 - 64
1 Dec 2020
Misir A Kaya V Basar H
Full Access

The ideal treatment method regarding various defect sizes after local aggressive tumor resection is unknown. We investigated the biomechanical properties of metaphyseal defect filling regarding different defect sizes and fixation methods. Ninety-one sheep tibias were divided into five groups as 21 tibias per four study groups and 7 tibias in the control group. Study groups were further divided into three subgroups according to 25%, 50% and 75% metaphyseal defect size. Control group tibias were left intact. In study group 1, a metaphyseal defect was created and no further process was applied. Metaphyseal defects were filled with cement without fixation in group 2. Cement filling and fixation with 2 screws were performed in group 3. In addition to cement filling, plate-screw fixation was performed in group 4. Axial loading test was applied to all tibias and the results were compared between study subgroups and control group. Plate-screw fixation was found to have the best biomechanical properties in all defect sizes. Load to failure for screw fixation was found to be significantly decreased between 25% and 50% defect size (P<0.05). However, load to failure for isolated cement filling was not affected from defect size (p>0.05). In conclusion, size of the defect predicts the fixation method in addition to filling with cement. Filling with cement in metaphyseal defects was found to be biomechanically insufficient. In addition to filling with cement, additional screw fixation in less than 25% defects and plate-screw fixation in more than 25% defects may decrease tibial plateau fracture or metaphyseal fracture risk after local aggressive tumor resection


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 8 - 8
1 Apr 2018
Marques E Fawsitt C Thom H Hunt LP Nemes S Lopez-Lopez J Beswick A Burston A Higgins JP Hollingworth W Welton NJ Rolfson O Garellick G Blom AW
Full Access

Background. Prosthetic implants used in primary total hip replacements have a range of bearing surface combinations (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic, metal-on-metal); head sizes (small <36mm, large 36mm+); and fixation techniques (cemented, uncemented, hybrid, reverse hybrid), which influence prosthesis survival, patient quality of life, and healthcare costs. This study compared the lifetime cost-effectiveness of implants to determine the optimal choice for patients of different age and gender profiles. Methods. In an economic decision Markov model, the probability that patients required one or more revision surgeries was estimated from analyses of UK and Swedish hip joint registries, for males and females aged <55, 55–64, 65–74, 75–84, and 85+ years. Implant and healthcare costs were estimated from hospital procurement prices, national tariffs, and the literature. Quality-adjusted life years were calculated using utility estimates, taken from Patient-Reported Outcome Measures data for hip procedures in the UK. Results. Optimal choices varied between traditionally used cemented metal-on-polyethylene and cemented ceramic-on-polyethylene implants. Small head cemented ceramic-on-polyethylene implants were optimal for males and females aged under 65. The optimal choice for adults aged 65 and older was small head cemented metal-on-polyethylene implants. Conclusions. The older the patient, the higher the probability that small head cemented metal-on-polyethylene implants are optimal. Small head cemented ceramic-on-polyethelyne implants are optimal for adults aged under 65. Our findings can influence NICE guidance, clinical practice, and commissioning of services. Funding. NIHR Research for Patient Benefit programme PB-PG-0613-31032


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 183 - 183
1 Jul 2014
Zderic I Windolf M Gueorguiev B Stadelmann V
Full Access

Summary. Time-lapsed CT offers new opportunities to predict the risk of cement leakage and to evaluate the mechanical effects on a vertebral body by monitoring each incremental injection step in an in-vitro vertebroplasty procedure. Introduction. Vertebroplasty has been shown to reinforce weak vertebral bodies and to prophylactically reduce fracture risks. However, bone cement leakage is a major vertebroplasty related problem which can cause severe complications. Leakage risk can be minimised by injecting less cement into the vertebral body, inevitably compromising the mechanical properties of the augmented bone, as a proper endplate-to-endplate connection of the injected cement is needed to obtain a mechanical benefit. Thus the cement flow in a vertebroplasty procedure requires a better understanding. This study aimed at developing a method to monitor the cement flow in a vertebral body and its mechanical effect. Materials and Methods. Eight fresh frozen human cadaveric vertebrae were prepared for augmentation by performing a bitrans- or bipedicular approach. Following they were XTremeCT-scanned (Scanco, Switzerland) at a nominal resolution of 82µm. A custom made setup enabled to fix the vertebrae in the CT bore (Siemens Emotion6) centrically. Bone cement (Vertecem V+, Synthes GmbH, Switzerland) was injected monopedicularly via a syringe driver (Harvard Apparatus, USA). Injection forces were recorded through a load cell (Type 9211, Kistler Instrumente AG, Switzerland) placed on the driver. Either a custom PEEK cannula or a trocar was inserted into each pedicle of a vertebra to allow artifact-free CT scanning. After each milliliter of injection a CT scan of the vertebra was performed at a nominal resolution of 0.63mm. Subsequently, the CT images were resampled to the original XTremeCT image and the cement cloud was segmented. The image data were then further processed for micro finite element (microFE) modeling (FAIM, Numerics88, Canada). The models were then solved for axial stiffness and Von Mises Stress (VMS) distribution. Finally, the vertebrae underwent a biomechanical quasistatic axial compression test (Mini Bionix II 858, MTS Systems Corp., USA). Results. Endplate-to-endplate connection of the cement was reached in 4 vertebrae. The average volume needed to reach the connection was 5.0±1.2 ml. Cement leakage occurred in all vertebrae, whereby in 4 cases the cement leaked into the spine channel. Each successive cement injection step was characterised with an increase of peak injection forces (16.5±12.7N at 1ml to 70.82±21.14N at 6ml). With respect to axial stiffness the mechanical tests and the microFE models correlated well (R. 2. = 0.778). Analyzing the top 100 VMS an elevated stress concentration between the endplate and the cement was observed unless the endplate was in direct contact with the cement. Conclusion. Cement flow can be monitored precisely at each injection step using the time-lapsed CT approach. Combined with microFE modeling the mechanical properties of the augmented bone can be evaluated for different incremental cement volumes injected. Our results suggest augmenting the bone until an endplate-to-endplate connection is established as otherwise partial filling would increase the risk of failure in the trabecular bone structure. This is in close agreement to other studies


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 26 - 31
1 Jan 1996
Senaha Y Nakamura T Tamura J Kawanabe K Iida H Yamamuro T

We have developed a bioactive bone cement (BA cement) consisting of Bis-GMA resin and bioactive glass powder. It has high compressive and tensile strengths, a low curing temperature and its bioactivity allows it to bond directly with bone. We operated on the 18 femora of nine mongrel dogs for intercalary replacement of part of the bone by a metal prosthesis using either PMMA cement or BA cement for fixation. Three dogs were killed at each of 4, 12 and 26 weeks after surgery for the evaluation of fixation strength by a push-out test and for histological examination by Giemsa surface staining and SEM. Fixation strengths with PMMA cement at 4, 12 and 26 weeks after surgery were 46.8 ± 18.9, 50.0 ± 24.7, and 58.2 ± 28.9 kgf (mean ±SD), respectively. Those with BA cement were 56.8 ± 26.1, 67.2 ± 19.2, and 72.8 ± 22.2 kgf, respectively. Fibrous tissue intervened between bone and PMMA cement but BA cement had bonded directly to bone at 12 and 26 weeks. This suggests that BA cement will be useful in providing long-lasting fixation of implants to bone under weight-bearing conditions


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 52 - 52
1 Apr 2017
Cundall-Curry D Lawrence J
Full Access

Background. Since it's establishment in 2007, the National Hip Fracture Database [NHFD] has been the key driving force in improving care for hip fracture patients across the UK. It has facilitated the setting of standards to which all musculoskeletal units are held, and guides service development to optimise outcomes in this group of patients. As with any audit, the ability to draw conclusions and make recommendations for changes in practise relies on the accuracy of data collection. This project aimed to scrutinise the data submitted to the NHFD from a Major Trauma Centre [MTC], focusing on procedure coding, and discuss the implications of any inaccuracies. Method. The authors performed a retrospective analysis of all procedure coding data entered into the NHFD from July 2009 to July 2014 at Cambridge University Hospitals NHS Foundation Trust. We examined 1978 cases for discrepancies, comparing procedure codes entered into the NHFD with post-procedure imaging and operative notes. Results. The procedure coding data submitted to the NHFD was highly inaccurate, with incorrect procedure codes in 24% of the 1978 cases reviewed. In particular, coding of cemented total arthroplasty and cemented bipolar hemiarthroplasty, with coding errors in registry data of 42% and 39% respectively. Of the 67 THRs performed only 52% were correctly coded for, and only 626 of the 915 hemiarthroplasties (68%). 16% of cannulated hip screws actually underwent primary arthroplasty. Conclusions. This study highlights the inaccuracy of coding data entered into the NHFD from a Major Trauma Centre, with data on arthroplasty being particularly inadequate. The unreliability of procedure data leaves us unable to evaluate surgical treatment strategies using the NHFD. This has worrying implications for standard setting, service development and, consequently, patient care. Level of evidence. 2c


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 59 - 59
1 Jan 2017
Winfield S Kumar G
Full Access

GIRFT was published in the United Kingdom with the aim of streamlining primary care pathways, secondary care, creating a network of hospitals and treatment centres and to better regulate introduction of new implants. It also proposed the use of Orthopaedic Devices Evaluation Panel (ODEP) 10A* rated cemented implants in hip arthroplasty. Aim: The purpose of this study was to assess the effects of adopting GIRFT on surgical time, length of stay, changes to the implants used and number of cases per surgical list. Prior to adopting GIRFT, elective primary total hip replacement (THR) was predominantly uncemented THR. Age, sex, Body Mass Index (BMI), American Society of Anesthetiss (ASA), closure technique and surgical time of 50 consecutive primary uncemented THR were analysed to identify the appropriate statistical methods. Mean and standard deviation for surgical time were identified. Threshold increase in surgical time was set at 20 minutes. Based on expected difference of 20 minutes and standardised difference, minimum sample size was calculated to be 19. Prospective data on 60 consecutive uncemented THR and 30 consecutive cemented primary THR were included in this study. Inclusion criteria – primary THR for arthritis by single surgeon. Exclusion criteria – previous hip surgery, complex primary, abnormal anatomy. No differences in age, sex, BMI, ASA and length of stay between the two groups. Surgical time was significantly increased by 28 minutes (p<0.001). Implants used changed from 7A*/5A* uncemented THR to 10A* (18/30) and 7A*(12/30) cemented THR. There was a reduction in number of THR done per surgical list due to the increase in surgical time (3 instead of 4). GIRFT compliance improved from 0% cemented to 100% cemented. 0% 10A* rated implants to 66% 10A* rated implants. Undertaking cemented THR instead of uncemented THR is associated with significantly increased surgical time. Hence, number of THR surgeries performed in a day's list is accordingly reduced. There is potential for financial loss when the savings in the implants used is compared with the reduction in the number of surgeries performed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 64 - 64
1 Jan 2017
Pereira J Ramos A Completo A
Full Access

Positioning of the hip resurfacing is crucial for its long term survival and is critical in young patients for some reasons; manly increase the wear in the components and change the load distribution. THR have increased in the last years, mainly in young patients between 45 to 59 years old. The resurfacing solution is indicated for young patients with good bone quality. A long term solution is required for these patients to prevent hip revision. The resurfacing prosthesis Birmingham Hip Resurfacing (BHR) was analyzed in the present study by in vitro experimental studies. This gives indications for surgeons when placing the acetabular cup. One synthetic left model of composite femur (Sawbones®, model 3403), which replicates the cadaveric femur, and four composite pelvic bones (Sawbones®, model 3405), were used to fix the commercial models of Hip resurfacing (Birmingham model). The resurfacing size was chosen according to the head size of femurs with 48 mm head diameter and a cup with 58 mm. They were introduced by an experimented surgeon with instrumental of prosthesis. The cup is a press fit system and the hip component was cemented using bone cement Simplex, Stryker Corp. The acetabular cup was analyzed in 4 orientations; in anteverion with 15º and 20°; and in inclination 40 and 45°. Combinations of these were also considered. The experimental set-up was applied according to a system previously established by Ramos et al. (2013) in the anatomic position. The femur rotates distally and the Pelvic moves vertically as model changes, such that the same boundary conditions are satisfied. This system allows compensating motions of the acetabular cup orientation. A vertical load of 1700 N was applied on all cases, which have resulted in joint reaction force of 2.4 kN. The femur and iliac bone was instrumented with rosettes. 5 repetitions at each position were conducted. When the femur was instrumented with three rosettes in medial, anterior and posterior aspect, the maximum strain magnitude was observed in the medial aspect of femur with a minimum principal strain of −2070µε for 45° inclination and 20° of anterversion. The pubic region was found most critical region after instrumenting the Iliac bone with four rosettes, with a minimum principal strain around −2500µε (rosette 1), for the 45° inclination and 20° of anterversion. We have observed the great influence of the inclination on the strain distribution, changing its magnitude from compression to traction in different bone regions. The minimum principal strain is more critical in medial aspect of the femur and the influence of strain is about 7% when orientation and inclination change. The maximum influence was observed in the anterior aspect, where the anteversion presents a significant influence. The results show the interaction between inclination and anterversion in all aspects, being observed lower values in lower angles. The orientation of the acetabular cup significantly influences the strain distribution on the iliac surface. Besides, as anterversion increases, more strains are induced, mainly in the region of iliac body (rosette 3)


Bone & Joint Research
Vol. 4, Issue 3 | Pages 29 - 37
1 Mar 2015
Halim T Clarke IC Burgett-Moreno MD Donaldson TK Savisaar C Bowsher JG

Objectives. Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt–chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA). Methods. Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range 5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments (5 mg) were inserted at ten intervals during the five million cycle (5 Mc) test. . Results. In a clean test phase (0 Mc to 0.8 Mc), lubricants retained their yellow colour. Addition of metal particles at 0.8 Mc turned lubricants black within the first hour of the test and remained so for the duration, while PMMA particles did not change the colour of the lubricant. Rates of wear with PMMA, CoCr and Ti6Al4V debris averaged 0.3 mm. 3. /Mc, 4.1Â mm. 3. /Mc and 6.4 mm. 3. /Mc, respectively. . Conclusions. Metal particles turned simulator lubricants black with rates of wear of MOM bearings an order of magnitude higher than with control PMMA particles. This appeared to model the findings of black, periarticular joint tissues and high CoCr wear in failed MOM replacements. The amount of wear debris produced during a 500 000-cycle interval of gait was 30 to 50 times greater than the weight of triggering particle allotment, indicating that MOM bearings were extremely sensitive to third-body wear. Cite this article: Bone Joint Res 2015;4:29–37


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims. Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA. Methods. This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living. Results. Small micromotions (mean < 12 µm) were found to occur at the bone-implant interface for all loading cases with or without a stem. Stem inclusion was associated with lower micromotion, however these reductions were too small to have any clinical significance. Peak interface micromotion, even when the cone is used without a stem, was too small to effect osseointegration. The maximum difference occurred with stair descent loading. Stress concentrations in the bone occurred around the inferior aspect of each implant, with the largest occurring at the end of the long stem; these may lead to end-of-stem pain. Stem use is also found to result in stress shielding in the bone along the stem. Conclusion. When a metaphyseal cone is used at rTKA to manage uncontained posterior or medial defects of up to 10 mm depth, stem use may not be necessary. Cite this article:Bone Joint Res. 2020;9(4):162–172


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 62 - 62
1 Mar 2013
HACHEM M DEB S
Full Access

Introduction. Polymethylmethacrylate(PMMA) bone cement has been used in joint reconstruction surgery and recently introduced for treatment of osteoporotic vertebral compression fracture. However, the use of PMMA bone cement in vertebroplasty leads to extensive bone stiffening and high rate of adjacent vertebrae fracture. Aim. The purpose of this study was to investigate the properties of PMMA bone cement augmented with collagen and assess its characteristics and relevance for the reduction of complication rate associated with vertebroplasty. Methods. Bone cement was produced using 2 types of PMMA based bone cement. Augmented groups were prepared using 40g of bone cement with 1% of rat tail liquid collagen. Mixing was conducted in controlled laboratory environment and at room temperature. The working and setting time and the mechanical properties were determined in accordance to ASTM standards for acrylic cements. The effect of ageing in simulated body fluid(SBF) on mechanical properties of these cements and the microstructure were studied. Results. Addition of collagen to bone cement has shown no marked effect on the working and setting time and produces bone cement with good injectability. The compressive strength is not affected but the modulus shows the material is less brittle than PMMA. Conclusion. Addition of liquid collagen to PMMA based bone cement does not necessarily compromise the properties of the cements and produce cement with good injectability and less brittle than PMMA based bone cement alone. However, bone cement augmented with different concentration of collagen need to be studied further in order to assess its clinical relevance especially in vertebroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 771 - 776
1 Jul 2004
Frei H Mitchell P Masri BA Duncan CP Oxland TR

We studied various aspects of graft impaction and penetration of cement in an experimental model. Cancellous bone was removed proximally and local diaphyseal lytic defects were simulated in six human cadaver femora. After impaction grafting the specimens were sectioned and prepared for histomorphometric analysis. The porosity of the graft was lowest in Gruen zone 4 (52%) and highest in Gruen zone 1 (76%). At the levels of Gruen zones 6 and 2 the entire cross-section was almost filled with cement. Cement sometimes reached the endosteal surface in other Gruen zones. The mean peak impaction forces exerted with the impactors were negatively correlated with the porosity of the graft


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 45 - 45
1 Aug 2012
Craig J Buchanan F O'Hara R Dunne N
Full Access

Vertebroplasty is a minimal invasive surgical procedure for treatment of vertebral compressive fractures, whereby cement is injected percutaneously into a vertebral body. Cement viscosity is believed to influence injectability, cement wash-out and leakage. Altering the liquid to powder ratio can affect the viscosity, level of cohesion and extent cement fill within the vertebral body and the ultimately strength and stiffness of the cement-vertebra composite. The association of these combined factors remains unclear. The aim of this study was to determine the relationship between cement viscosity and the potential augmentation of strength and stiffness in a model simulating in-vitro prophylactic vertebroplasty of osteoporotic vertebral bodies. Samples of synthetic bone (Sawbone) representing osteoporotic bone were manually injected with 1mL of calcium phosphate cement using a 11G cannulated needle. Calcium phosphate cement was produced by mixing alpha-tricalcium phosphate, calcium carbonate and hydroxyapatite with an aqueous solution of 5 wt% disodium hydrogen phosphate. Three liquid to powder ratio (LPR) representing different viscosity levels were used; i.e. 0.5mL/g (low viscosity), 0.45mL/g (medium viscosity) and 0.35mL/g (high viscosity). Cement filled samples were then placed in an oven (37oC) for 20 min and then immersed in Ringer's solution (37oC) for 3 days. Samples of synthetic bone without cement injection were used as controls. Potential for leakage and wash-out was determined using gravimetric analysis. Extent of cement fill was determined using computer tomography (CT). Samples were tested under axial compression at a rate of 1 mm/min and the strength and stiffness determined. Statistical significance against controls was determined using a one-way analysis of variance (p<0.05). Low viscosity cement showed more cement leakage (p=0.512) and increased cement wash-out after 3 days in Ringer's solution (p=0.476). Qualitative assessment of cement fill within the vertebral body using CT imaging supported the wash-out results. The strength (p<0.05-0.01) and stiffness (p<0.01) of samples significantly increased by cement injection in comparison to control, the extent of this increase was greater with increasing cement viscosity. Linear correlation analysis showed a definite association between the mechanical properties and viscosity of injected cement and was dependent on the amount of cement retained within the synthetic bone post-setting


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 12 - 12
1 May 2012
Simpson DJ Kendrick B Price AJ Murray D Gill H
Full Access

Introduction. Unicompartmental Knee Replacement (UKR) is an appealing alternative to Total Knee Replacement (TKR) when the patient has isolated compartment osteoarthritis (OA). A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain following implantation with a UKR; this may be related to elevated bone strains in the tibia. The aim of this study was to investigate the mechanical environment of the tibia bone adjacent to the tray wall, following UKR, to determine whether this region of bone resorbs, and how altering the mechanical environment affects tibia strains. Materials and methods. A finite element (FE) model of a cadaver tibia implanted with an Oxford UKR was used in this study, based on a validated model. A single static load, measured in-vivo during a step-up activity was used. There was a 1 mm layer of cement surrounding the keel in the cemented UKR, and the cement filled the cement pocket. In accordance with the operating procedure, no cement was used between the tray wall and bone. For the cementless UKR a layer of titanium filled the cement pocket. An intact tibia was used to compare to the cemented and cementless UKR implanted tibiae. The tibia was sectioned by the tray wall, defining the radiolucency zone (parallel to the vertical tray wall, 2 mm wide with a volume of 782.5 mm. 3. ), corresponding to the region on screened x-rays where radiolucencies are observed. Contact mechanics algorithms were used between all contacting surfaces; bonded contact was also introduced between the tray wall and adjacent bone, simulating a mechanical tie between them. Strain energy density (SED), was compared between the intact and implanted tibia for the radiolucency zone. Equivalent strains were compared on the proximal tibia between the intact and implanted tibia models. Forty patients (20 cemented, 20 cementless) who had undergone UKR were randomly selected from a database, and assessed for radiolucency. Results. The SED in the radiolucency zone was 80% lower in the cemented and cementless tibia, compared to the intact tibia, without a mechanical tie between the tibial tray wall and adjacent bone. When a mechanical tie was introduced the SED in the radiolucency zone was 35% higher in the cemented and cementless tibia, compared to the intact tibia. The strain on the proximal tibia was reduced by 20% when a mechanical tie was used between the tray wall and adjacent bone. Radiolucency at the tray wall was observed in all forty radiographs examined. Discussion. This work has presented a static snapshot of the load being carried through the proximal tibia following implantation with an Oxford UKR. It has been shown that by introducing a mechanical tie between the tibial tray wall and the adjacent bone, the SED in the region observed to have radiolucency is increased; this has the potential of reducing the likelihood of a radiolucency occurring in that region. Moreover, the strain observed in the proximal tibia was reduced when a mechanical tie was introduced, which may reduce the incidence of pain following implantation with a UKR. It is recommended that integration between the bone and the tray wall is important for UKR


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 900 - 905
1 Aug 2003
Shardlow DL Stone MH Ingham E Fisher J

Proponents of the biological theory of aseptic loosening have in recent years tended to concentrate on the production and distribution of particulate ultra-high-molecular-weight polyethylene (UHMWPE) debris around the potential joint space. However, mechanical loading of cemented implants with the differing elastic moduli of metal stems, polymethylmethacrylate (PMMA) cement and bone can result in relative micromotion, implying the potential for production of metal and PMMA particles from the stem-cement interface by fretting wear. In order to investigate the production and biological reactivity of debris from this interface, PMMA and metal particulate debris was produced by sliding wear of PMMA pins containing barium sulphate and zirconium dioxide against a Vaquasheened stainless steel counterface. This debris was characterised by SEM, energy-dispersive analysis by X-ray (EDAX) and image analysis, then added to cell cultures of a human monocytic cell line, U937, and stimulation of pro-osteolytic cytokines measured by ELISA. Large quantities of PMMA cement debris were generated by the sliding wear of PMMA pins against Vaquasheened stainless steel plates in the method developed for this study. Both cements stimulated the release of pro-osteolytic TNFα from the U937 monocytic cell line, in a dose-dependent fashion. There was a trend towards greater TNFα release with Palacos cement than CMW cement at the same dose. Palacos particles also caused significant release of IL-6, another pro-osteolytic cytokine, while CMW did not. The particulate cement debris produced did not stimulate the release of GM-CSF or IL1β from the U937 cells. These results may explain the cytokine pathway responsible for bone resorption caused by particulate PMMA debris. Radio-opaque additives are of value in surgical practice and clinical studies to quantify the relevance of these in vitro findings are required before the use of cement containing radio-opacifier is constrained


Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives. The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic. Methods. We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs. Results. There was no evidence of cement attachment on any of the 11 Attune trays examined. There were significant differences between Ti and CoCr PFC Sigma implants and Attune designs (p < 0.05); however, there was no significant difference between CoCr PFC Sigma RP and Attune designs (p > 0.05). There were significant differences in the design features between the investigated designs (p < 0.05). Conclusion. The majority of the earliest PFC Sigma designs showed evidence of cement, while all of the retrieved Attune trays and the majority of the RP PFC trays in this study had no cement attached. This may be attributable to the design differences of these implants, in particular in relation to the cement pockets. Our results may help explain a controversial aspect related to cement attachment in a recently introduced TKA design. Cite this article: A. Cerquiglini, J. Henckel, H. Hothi, P. Allen, J. Lewis, A. Eskelinen, J. Skinner, M. T. Hirschmann, A. J. Hart. Analysis of the Attune tibial tray backside: A comparative retrieval study. Bone Joint Res 2019;8:136–145. DOI: 10.1302/2046-3758.83.BJJ-2018-0102.R2


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 156 - 161
1 Jan 1998
ElMaraghy AW Humeniuk B Anderson GI Schemitsch EH Richards RR

We examined the roles of methylmethacrylate (MMA) monomer and cementing technique in the formation, and haemodynamic outcome, of pulmonary fat emboli. The preparation of the femoral canal and the cementing technique were studied in four groups of adult dogs as follows: control (no preparation); lavage; cement pressurisation; and cement pressurisation after lavage. We measured the intramedullary pressure, pulmonary artery pressure (PAP), pulmonary capillary wedge pressure and bilateral femoral vein levels of triglyceride, cholesterol and MMA monomer at rest and after reaming, lavage, and cementing. Femoral vein triglyceride and cholesterol levels did not vary significantly from resting levels despite significant elevations in intramedullary pressure with reaming, lavage and cementing (p = 0.001). PAP was seen to rise significantly with reaming (p = 0.0038), lavage (p = 0.0031), cementing (p = 0.0024) and cementing after lavage (p = 0.0028) while the pulmonary capillary wedge pressure remained unchanged. MMA monomer was detected in femoral vein samples when cement pressurisation was used. Intramedullary lavage before cementing had no significant effect on the MMA level. Haemodynamic evidence of pulmonary embolism was noted with reaming and intramedullary canal preparation, irrespective of the presence of MMA monomer. We found no relationship between MMA monomer level and intramedullary pressure, PAP or pulmonary capillary wedge pressure. Our findings suggest that the presence of MMA monomer in femoral venous blood has no effect on the formation of fat emboli or their pulmonary haemodynamic outcome during cemented hip arthroplasty


Bone & Joint Research
Vol. 6, Issue 6 | Pages 366 - 375
1 Jun 2017
Neves N Linhares D Costa G Ribeiro CC Barbosa MA

Objectives

This systematic review aimed to assess the in vivo and clinical effect of strontium (Sr)-enriched biomaterials in bone formation and/or remodelling.

Methods

A systematic search was performed in Pubmed, followed by a two-step selection process. We included in vivo original studies on Sr-containing biomaterials used for bone support or regeneration, comparing at least two groups that only differ in Sr addition in the experimental group.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 962 - 970
1 Jul 2007
Albert C Patil S Frei H Masri B Duncan C Oxland T Fernlund G

This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting. Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured. Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration/micromotion, and valgus/varus migration were significantly higher in the no-pressure group than in that subjected to pressure. These motion components correlated negatively with the mean area of cement and its contact with the endosteum. The presence of cement at the endosteum appears to play an important role in the initial stability of the implant following impaction allografting


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 120 - 122
1 Jan 2006
Kwong FNK Power RA

The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may be a factor involved. Palacos R, Palacos LV (both with gentamicin), CMW 1, CMW 2, CMW Endurance (CMWE) and Simplex were prepared under vacuum and allowed to cure overnight in similar cylinders. The next day this volume was determined by the displacement of water. Shrinkage varied between 3.82% and 7.08% with CMWE having the lowest and Palacos LV the highest. This could be a factor to consider when choosing a cement for a shape-closed stem