Advertisement for orthosearch.org.uk
Results 1 - 20 of 60
Results per page:
Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 81
1 Mar 2002
Siboto G Roche S
Full Access

We treated 133 traumatic posterior dislocations surgically between July 1994 and March 2001. In 16 patients, labral tears had occurred. Operating on posterior hip dislocations, initially we fixated the posterior wall with screws and/or buttress plate, depending on the size of the fragment, and did suture the torn labrum, relying rather on the buttress plate or intact posterior wall for stability. We began repairing the torn labrum when we realised that any small fragments still attached to the labrum simply pull out from under the buttress plate, allowing the hip to redislocate. Once the wall has been reconstructed, interrupted sutures are passed through the labrum, with the hip internally rotated to prevent shortening of the capsule when sutures are tied. A one-third tubular plate is placed over the sutures lying on the posterior wall and fixed with screws. The sutures are then tied individually over the plate. Postoperatively the patient is kept in bed for six weeks, with the hip abducted and knee extended. Seven patients in whom the labrum was not repaired experienced redislocation. We performed second operations on two of them, repositioning the plates and reconstructing the posterior wall, but redislocation again occurred. The redislocated femoral heads were damaged because they rubbed against the plate and screws. In the other nine patients, we sutured the labrum, and in a 3 month to 2.5 year follow-up, no redislocation has occurred. . Labral repair restores stability, and tying interrupted sutures over a buttress plate is an easy and effective method of repair


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction. Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF. Objectives. To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA). Material and Methods. We performed a comparative retrospective study between two series of patients treated by fixed volar angle locking plate (40 patients) or volar buttress plate (36 patients). Distal radius fractures were classified by the AO/ASIF Müller classification after X-ray study in two views (Anteroposterios and lateral views), surgical treatment was indicated by the type of fracture (unstable fractures) and open fractures. Demographic information was gathered, injury mechanism and postoperatory complications. The minimal follow-up was 10 months. We performed clinical and radiographic evaluations before surgery, postoperatory, to 3 months and at the end of the follow-up (Palmar tilt, radial inclination, radial height and the radioulnar index were measured). Lidström's and Quick Dash scale, by means of telephonic survey, were used for the functional evaluation. Results. The time from fracture to surgery was on average 3.74 days in the group of DVR ® plates and 1.69 days for the group treated with T buttress plates. Henry's approach was realized in every case and the average time spent in surgery was 74 minutes for patients treated with T buttress plate and 80 minutes for patients treated with plate DVR®. In some cases K wires had to be used in 9 cases in the DVR® group and 7 in the other group. DVR® group obtained better results in radiological evaluation except in the radial inclination. In the Quick Dash scale, conducted a telephone survey, the average for the DVR® group was 26.40 (CI: 13.6 to 81.8) and 33.37 (CI: 10.2–90) for the group of T buttress plate (p=0.055). Conclusion. The potential advantages of ORIF in the distal radius fractures are low complication rate, stable subchondral fixation and early active movement of the wrist in the postoperative period. The disadvantages are a high cost, greater complexity and surgical exposure. Locking plates were designed to prevent postoperative collapse of the fracture also allows a better fix system in osteoporotic bone. Both types of plates obtained good results radiological and functional at the end of follow-up but we have obtained better results in the patients treated with locking plates


Bone & Joint Open
Vol. 5, Issue 3 | Pages 227 - 235
18 Mar 2024
Su Y Wang Y Fang C Tu Y Chang C Kuan F Hsu K Shih C

Aims. The optimal management of posterior malleolar ankle fractures, a prevalent type of ankle trauma, is essential for improved prognosis. However, there remains a debate over the most effective surgical approach, particularly between screw and plate fixation methods. This study aims to investigate the differences in outcomes associated with these fixation techniques. Methods. We conducted a comprehensive review of clinical trials comparing anteroposterior (A-P) screws, posteroanterior (P-A) screws, and plate fixation. Two investigators validated the data sourced from multiple databases (MEDLINE, EMBASE, and Web of Science). Following PRISMA guidelines, we carried out a network meta-analysis (NMA) using visual analogue scale and American Orthopaedic Foot and Ankle Score (AOFAS) as primary outcomes. Secondary outcomes included range of motion limitations, radiological outcomes, and complication rates. Results. The NMA encompassed 13 studies, consisting of four randomized trials and eight retrospective ones. According to the surface under the cumulative ranking curve-based ranking, the A-P screw was ranked highest for improvements in AOFAS and exhibited lowest in infection and peroneal nerve injury incidence. The P-A screws, on the other hand, excelled in terms of VAS score improvements. Conversely, posterior buttress plate fixation showed the least incidence of osteoarthritis grade progression, postoperative articular step-off ≥ 2 mm, nonunions, and loss of ankle dorsiflexion ≥ 5°, though it underperformed in most other clinical outcomes. Conclusion. The NMA suggests that open plating is more likely to provide better radiological outcomes, while screw fixation may have a greater potential for superior functional and pain results. Nevertheless, clinicians should still consider the fragment size and fracture pattern, weighing the advantages of rigid biomechanical fixation against the possibility of soft-tissue damage, to optimize treatment results. Cite this article: Bone Jt Open 2024;5(3):227–235


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims. Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures. Methods. We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up. Results. Immediate postoperative radiological Matta’s reduction accuracy showed anatomical reduction (0 to 1 mm) in 23 cases (67.6%), satisfactory (2 to 3 mm) in nine (26.4%), and unsatisfactory (> 3 mm) in two (6%). Merle d’Aubigné score at the end of one year was calculated to be excellent in 18 cases (52.9%), good in 11 (32.3%), fair in three (8.8%), and poor in two (5.9%). Matta’s radiological grading at the end of one year was calculated to be excellent in 16 cases (47%), good in nine (26.4%), six in fair (17.6%), and three in poor (8.8%). Merle d’Aubigné score at latest follow-up deteriorated by one point in some cases, but the grading remained the same; Matta’s radiological grading at latest follow-up also remained unchanged. Conclusion. Stabilization of posterior column through AIP by medial surface plate along the sciatic notch gives good stability to posterior column, and at the same time can avoid morbidity of the additional lateral window. Cite this article: Bone Jt Open 2024;5(2):147–153


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 426 - 432
1 Mar 2005
Mueller CA Eingartner C Schreitmueller E Rupp S Goldhahn J Schuler F Weise K Pfister U Suedkamp NP

The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 817 - 823
1 Jun 2011
Solomon LB Callary SA Stevenson AW McGee MA Chehade MJ Howie DW

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51). Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 19 - 19
1 May 2015
Pease F Ward A Stevens A Cunningham J Sabri O Acharya M Chesser T
Full Access

Stable, anatomical fixation of acetabular fractures gives the best chance of a good outcome. We performed a biomechanical study to compare fracture stability and construct stiffness of three methods of fixation of posterior wall acetabular fractures. Two-dimensional motion analysis was used to measure fracture fragment displacement and the construct stiffness for each fixation method was calculated from the force / displacement data. Following 2 cyclic loading protocols of 6000 cycles, to a maximum 1.5kN, the mean fracture displacement was 0.154mm for the rim plate model, 0.326mm for the buttress plate and 0.254mm for the spring plate model. Mean maximum displacement was significantly less for the rim plate fixation than the buttress plate (p=0.015) and spring plate fixation (p=0.02). The rim plate was the stiffest construct 10962N/mm (SD 3351.8), followed by the spring plate model 5637N/mm (SD 832.6) and the buttress plate model 4882N/mm (SD 387.3). Where possible a rim plate with inter-fragmentary lag screws should be used for isolated posterior wall fracture fixation as this is the most stable and stiffest construct. However, when this method is not possible, spring plate fixation is a safe and superior alternative to a posterior buttress plate method


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 30 - 30
1 Jul 2022
Middleton R Jackson W Alvand A Bottomley N Price A
Full Access

Abstract. Background. Since 2012 we have routinely used the cementless Oxford medial unicompartmental knee arthroplasty (mUKA), with microplasty instrumentation, in patients with anteromedial osteoarthritis (AMOA) meeting modern indications. We report the 10-year survival of 1000 mUKA with minimum 4-year follow-up. Methods. National Joint Registry (NJR) surgeon reports were interrogated for each senior author to identify the first 1,000 mUKAs performed for osteoarthritis. A minimum of 4 years follow-up was required. There was no loss to follow-up. The NJR status of each knee was established. For each mUKA revision the indication and mechanism of failure was determined using local patient records. The 10-year implant survival was calculated using life-table analysis. Results. The 1,000 mUKA cohort represented 55% of all primary knee replacements in the period, with an average age of 67.7 years and a 54%/46% male/female split. There were 17 revisions (11 for arthritis progression, 4 infections, 1 dislocation and 1 aseptic loosening). The 10-year survival was 98% (44 at risk in 10th year). One patient sustained a periprosthetic fracture at 3 weeks, treated with buttress plate fixation. Discussion. This is the first detailed series reporting the long-term outcome of the cementless Oxford mUKA implanted using microplasty instrumentation. There was a low failure rate, with only one revision for aseptic loosening. Lateral progression was the commonest cause for revision, with an incidence of 1%. This report provides evidence that the combination of evidence-based indications, well-designed instrumentation and cementless fixation can provide excellent long-term survival for the Oxford mUKA in treating AMOA


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1165 - 1171
1 Sep 2013
Arastu MH Kokke MC Duffy PJ Korley REC Buckley RE

Coronal plane fractures of the posterior femoral condyle, also known as Hoffa fractures, are rare. Lateral fractures are three times more common than medial fractures, although the reason for this is not clear. The exact mechanism of injury is likely to be a vertical shear force on the posterior femoral condyle with varying degrees of knee flexion. These fractures are commonly associated with high-energy trauma and are a diagnostic and surgical challenge. Hoffa fractures are often associated with inter- or supracondylar distal femoral fractures and CT scans are useful in delineating the coronal shear component, which can easily be missed. There are few recommendations in the literature regarding the surgical approach and methods of fixation that may be used for this injury. Non-operative treatment has been associated with poor outcomes. The goals of treatment are anatomical reduction of the articular surface with rigid, stable fixation to allow early mobilisation in order to restore function. A surgical approach that allows access to the posterior aspect of the femoral condyle is described and the use of postero-anterior lag screws with or without an additional buttress plate for fixation of these difficult fractures. Cite this article: Bone Joint J 2013;95-B:1165–71


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 76 - 76
1 Sep 2012
Lidder S Heidari N Grechenig W Clements H Tesch N Weinberg A
Full Access

Introduction. Posterolateral tibial plateau fractures account for 7 % of all proximal tibial fractures. Their fixation often requires posterolateral buttress plating. Approaches for the posterolateral corner are not extensile beyond the perforation of the anterior tibial artery through the interosseous membrane. This study aims to provide accurate data about the inferior limit of dissection by providing measurements of the anterior tibial artery from the lateral joint line as it pierces the interosseous membrane. Materials and Methods. Forty unpaired adult lower limbs cadavers were used. The posterolateral approach to the proximal tibia was performed as described by Frosch et al. Perpendicular measurements were made from the posterior limit of the articular surface of the lateral tibial plateau and fibula head to the perforation of the anterior tibial artery through the interosseous membrane. Results. The anterior tibial artery coursed through the interosseous membrane at 46.3 +/− 9.0 mm (range 27–62 mm) distal to the lateral tibial plateau and 35.7 +/− 9.0 mm (range 17–50 mm) distal to the fibula head. There was no significant difference between right or left sided knees. Discussion. This cadaveric study demonstrates the safe zone (min 27 mm, mean 45mm) up to which distal exposure can be performed for fracture manipulation and safe application of a buttress plate for displaced posterorlateral tibial plateau fractures. Evidence demonstrates quality of reduction correlates with clinical outcome and the surgeon can expect to be able to use a small fragment buttress plate of up to 45mm as this is the mean


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 503 - 509
1 Apr 2007
Giannoudis PV Tzioupis C Moed BR

Our aim was to evaluate the efficacy of a two-level reconstruction technique using subchondral miniscrews for the stabilisation of comminuted posterior-wall marginal acetabular fragments before applying lag screws and a buttress plate to the main overlying posterior fragment. Between 1995 and 2003, 29 consecutive patients with acute comminuted displaced posterior-wall fractures of the acetabulum were treated operatively using this technique. The quality of reduction measured from three standard plain radiographs was graded as anatomical in all 29 hips. The clinical outcome at a mean follow-up of 35 months (24 to 90) was considered to be excellent in five patients (17%), very good in 16 (55%), good in six (21%) and poor in two (7%). The use of the two-level reconstruction technique appears to provide stable fixation and is associated with favourable results in terms of the incidence of post-traumatic osteoarthritis and the clinical outcome. However, poor results may occur in patients over the age of 55 years


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 135 - 135
1 Mar 2008
Duffy P Trask K Barron L Hennigar A Deluzio K Leighton R Dunbar M
Full Access

Purpose: The Less Invasive Stabilization System (LISS), Dynamic Condylar Screw (DCS) and Condylar Buttress Plate (CBP) are three common fixation methods for supracondylar femur fractures. The DCS and CBP are compression plates while the LISS uses locking screws to transfer load from bone to plate without compression. We developed a study to determine if the theoretical biomechanical advantages of the LISS would be evident in laboratory testing. Methods: Identical AO type C fractures were created in eighteen composite femurs and fixed with either LISS, CBP, or DCS (6 each). Roentgen Stereophotogrammetric Analysis (RSA) was used for analysis. Reference markers were implanted into each bone segment. Biplanar x-rays were taken to give a three-dimensional representation of the fracture. The femurs were loaded axially in an Instron 1350 and subjected to cyclic loading (50kg ± 25 for 50000 cycles). After loading, the bones were x-rayed to determine relative motion between fracture segments. To examine inducible displacement under static loading, the femurs were x-rayed in an unloaded and loaded (50 kg) condition. Again, RSA was used for analysis. Results: RSA-CMS software was used to analyze relative motion between the bone segments. After cyclic loading, the condylar buttress plate showed significantly more permanent deformation between the medial condyle and shaft of the femur than the DCS or LISS. Under static load, the LISS showed greater displacement than the other devices between the medial condyle and shaft, and between the lateral condyle and shaft. Conclusions: The LISS demonstrated less permanent deformation but greater inducible deformation between the medial femoral condyle and femoral shaft, compared to the DCS and CBP. The results were statistically significant. These results may have clinical implications regarding the choice of fixation devices for this difficult fracture pattern. Funding: Other Education Grant. Funding Parties: Capital Health Research Grant


Bone & Joint 360
Vol. 12, Issue 3 | Pages 32 - 35
1 Jun 2023

The June 2023 Trauma Roundup360 looks at: Aspirin or low-molecular-weight heparin for thromboprophylaxis?; Lateral plating or retrograde nailing for distal femur fractures?; Sciatic nerve palsy after acetabular fixation: what about patient position?; How reliable is the new OTA/AO classification for trochanteric hip fractures?; Young hip fractures: is a medial buttress the answer?; When is the best time to ‘flap’ an open fracture?; The mortality burden of nonoperatively managed hip fractures.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 36 - 39
1 Dec 2024

The December 2024 Trauma Roundup360 looks at: Percutaneous lumbopelvic fixation is effective in the management of unstable transverse sacral fractures; A systematic review on autologous matrix-induced chondrogenesis (AMIC) for chondral knee defects; Stable clinical and radiological outcomes at medium and over five-year follow-up of calcaneus fracture open reduction internal fixation using a sinus tarsi approach; Right or left? It might make a difference; Suprapatellar versus infrapatellar tibial nailing – is there a difference in anterior knee pain and function?; Can patients safely weightbear following ankle fracture fixation?; Anterior-to-posterior or a plate fixation for posterior malleous fractures?; Audio distraction for traction pin insertion: a prospective randomized controlled study; Is intramedullary nailing of femoral diaphyseal fractures in the lateral decubitus position as safe and effective as on a traction table?


Bone & Joint 360
Vol. 13, Issue 2 | Pages 35 - 38
1 Apr 2024

The April 2024 Trauma Roundup360 looks at: The infra-acetabular screw in acetabular fracture surgery; Is skin traction helpful in patients with intertrochanteric hip fractures?; Reducing pain and improving function following hip fracture surgery; Are postoperative splints helpful following ankle fracture fixation?; Biomechanics of internal fixation in Hoffa fractures: a comparison of four different constructs; Dual-plate fixation of periprosthetic distal femur fractures; Do direct oral anticoagulants necessarily mean a delay to hip fracture surgery?; Plate or retrograde nail for low distal femur fractures?.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 4 | Pages 724 - 727
1 Nov 1965
Ellis J

1. A method of treating Smith's fracture and Barton's anterior fracture-dislocation of the wrist by internal splintage is described. 2. The application of a special buttress plate fixed to the lower anterior aspect of the radius is advocated; no external splintage is used


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 153 - 153
1 Jan 2013
Lidder S Masterson S Grechenig S Heidari N Clements H Tesch P Grechenig W
Full Access

Introduction. Posterior malleolar fractures are present in up to 44% of all ankle fractures. Those involving > 25% of the articular surface have a higher rate of posterior ankle instability which may predispose to post traumatic arthritis. The posterolateral approach to the distal tibia allows direct reduction and stabilization of the posterior malleolus and concomitant lateral malleolus fractures. An anatomical study was performed to establish the safe zone of proximal dissection to avoid injury to the peroneal vessels in this uncommon approach. Methods. 26 unpaired adult lower limbs were dissected using the posterolateral approach to the distal tibia as described by Tornetta et al. The peroneal artery was identified coursing through the intraosseous membrane on deep dissestion as the flexor hallucis longus muscle was reflected medially. The level of its bifurcation was also noted over the tibia. Perpendicular measurements were made from the tibial plafond to these variable anatomical locations. Results. The peroneal artery bifurcated at 83+/−21 mm (41–115mm) proximal to the tibial plafond and perforated through the interossoeus membrane 64+/−18 mm (47–96mm) proximal to the tibial plafond. Conclusion. The safe zone for the posterolateral approach to the distal tibia is described. Caution is advised as the bifurcation and perforating artery may be as little as 41mm from the tibial plafond. This is important during deep dissection when the belly of the flexor hallucis longus muscle is reflected medially from the medial edge of the fibula. Once the peroneal artery was mobilized a buttress plate could easily be placed beneath it


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 401 - 405
1 May 1994
Keating J Court-Brown C McQueen M

We reviewed a series of 79 distal radial fractures with volar displacement which had been fixed internally using a buttress plate. The fractures were classified using the Frykman and AO systems; 59% were intraarticular. Complications occurred in 40.5% of cases; malunion was most frequent (28%). Functional recovery in patients with malunion was significantly worse than in those with good anatomical restoration (p < 0.001). The AO and Frykman classifications and the degree of restoration of volar tilt were predictive of outcome


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 219 - 219
1 Nov 2002
DeOrio J Ware A
Full Access

Purpose: To determine if union could be achieved in peri-plafond tibial fractures by using a fibular plate with the screws brought all the way across to the medial tibial cortex. Materials & Methods: Between September 1994 and March 2000, five patients were treated with this technique with autologous bone grafting with or without a tibial buttress plate. All of the fractures were within 2cm of the tibial plafond, thereby preventing adequate fixation with a tibial plate alone. The preoperative diagnoses included infected distal tibial nonunion (3 cases), a distal tibial nonunion (1 case), and distal tibial malunion (1 case). All had associated fibular involvement. The patients had undergone 12 prior operations. Their average age was 59 years. All patients healed without additional surgery and all were pleased with their procedure. Conclusion: The difficulty in obtaining fixation of a periplafond tibial nonunion with fibular involvement was solved using rigid internal fixation via a fibular plate with the screws brought entirely across the tibia. All five patients achieved osseous union and stability and functionally were able to walk with minimal or no discomfort and required no ambulatory aides


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 364 - 364
1 Mar 2004
Petsatodes G Christoforides J Antonarakos P Karataglis D Pournaras J
Full Access

Aim: The results of operative treatment of acetabular fractures, as well as its role in the prevention of post-traumatic osteoarthritis are presented. Methods: From 1990 to 2000, þfty patients had an open reduction and internal þxation of an acetabular fracture. Thirty-two patients were male and eighteen were female, with an average age of 37,8 years (range: 18 to 71 years). The mechanism of injury was a motor vehicle accident in most cases (84%). 22 fractures were A-type, 24 B-type and 4 C-type according to the AO classiþcation, while according to the Letournel-Judet classiþcation 21 fractures were simple and 21 complex. Osteosynthesis was achieved with either lag screws alone or with a combination of lag screws and a buttress plate. Results: Follow-up ranged from 2–10 years (average: 5,8 years). Clinical evaluation according to the Dñ Aubigne-Postel scoring system gave 20 excellent (40%), 18 good (36%), 5 fair (10%) and 7 poor (14%) results. Early postoperative complications included 5 cases of common peroneal nerve palsy and 3 cases of wound infection. Late complications included 1 case of avascular necrosis of the femoral head, 12 cases of post-traumatic osteoarthritis (24%) and 5 cases of Brooker III heterotopic ossiþcation (10%). Conclusions: Operative treatment of ace-tabular fractures although demanding bears very good results. Post-traumatic arthritis remains a common complication, even if care is taken for the anatomic reduction of the fracture