Is Non-Weight-Bearing Necessary? (INWN) is a pragmatic multicentre randomised controlled trial comparing immediate protected weight-bearing (IWB) with non-weight-bearing cast immobilisation (NWB) following ankle fracture fixation (ORIF). This trial compares; functional outcomes, complication rates and performs an economic analysis to estimate cost-utility. IWB within 24hrs was compared to NWB, following ORIF of all types of unstable ankle fractures. Skeletally immature patients and tibial plafond fractures were excluded. Functional outcomes were assessed by the Olerud-Molander Ankle Score (OMAS) and RAND-36 Item Short Form Survey (SF-36) taken at regular follow-up intervals up to one year. A cost-utility analysis via decision tree modelling was performed to derive an incremental cost effectiveness ratio (ICER). A standard gamble health state valuation model utilising SF-36 scores was used to calculate Quality Adjusted Life Years (QALYs) for each arm. We recruited 160 patients (80 per arm), aged 15 to 94 years (M = 45.5), 54% female. Complication rates were similar in both groups. IWB demonstrated a consistently higher OMAS score, with significant values at 6 weeks (MD=10.4, p=0.005) and 3 months (MD 12.0, p=0.003). Standard gamble utility values demonstrated consistently higher values (a score of 1 equals perfect health) with IWB, significant at 3 months (Ẋ = 0.75 [IWB] / 0.69 [NWB], p=0.018). Cost-utility analysis demonstrated NWB is €798.02 more expensive and results in 0.04 fewer QALYs over 1 year. This results in an ICER of −€21,682.42/QALY. This negative ICER indicates cost savings of €21,682.42 for every QALY (25 patients = 1 QALY gain) gained implementing an IWB regime. IWB demonstrates a superior functional outcome, greater cost savings and similar complication rates, compared to NWB following ankle fracture fixation.
Abstract. Background. The Oxford Domed Lateral (ODL) Unicompartmental Knee Replacement (UKR) has some advantages over other lateral UKRs, but the mobile
Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this
Ultra-high molecular weight polyethylene (UHMWPE) is a commonly used as
Introduction. The results of the original mobile
UKA with mobile
We have undertaken a series of clinical trials over the last 20 years to look at different
Background. As the number of ceramic THR bearings used worldwide is increasing, the number of implants that experience off-normal working conditions, e.g. edge loading, third bodies in the joint, soft tissues laxity, dislocation/subluxation of the joint, increases too. Under all such conditions the
Summary Statement. Wear of total knee replacement (TKR) is a clinical concern. This study demonstrated low-conformity moderately cross-linked-polyethylene fixed
In 2011, approximately 1.6 million total hip arthroplasties (THAs) were conducted in 27 of the 34 member countries in the Organization for Economic Cooperation and Development (OECD) However, approximately 10–15% of patients still require revision surgery every year. Therefore, new technologies are required to increase the life-spam of the prosthesis from the current 10–15 years to at least 20–30 years. Our strategy focuses on surface modification of the
To date there has been no material for endoprosthetics providing excellent resistance to abrasion and corrosion combined with great tensile strength, fracture toughness, and bending strength, as well as adequate biocompatibility. Carbon-fiber-reinforced silicon carbide (C/SiC, C/C-SiC or C/SiSiC) is as a ceramic compound a potentially novel biomaterial offering higher ductility and durability than comparable oxide ceramics. Aim of this investigation was to test the suitability of C/SiC ceramics as a new material for
This was a retrospective study of registry data from a National Orthopaedic Hospital for all THRs with 10-year follow-up data. Inclusion criteria were all THRs with a minimum of 10-year follow-up data. All metal-on-metal (MoM) THRs and MoM resurfacings were excluded from the analysis due to the high rate of revision associated with these bearings. Univariate and multivariate analyses controlling for confounding variables were performed to compare outcomes. A total of 1,697 THRs were performed in 1,553 patients. The four significant predictors for revision were fixation type (p<0.01), surface
Study Purpose. A preliminary study to compare continuous sagittal plane lumbar inter-vertebral kinematics in 10 healthy volunteers in recumbent and weight
We report the short term follow up of nineteen consecutive PFC sigma unicompartmental knee replacements carried out in our institution with minimum one year follow up. The PFC Sigma medial unicompartmental knee replacement is a fixed
Introduction. Kager's fat pad (KFP) is located in Kager's triangle between the Achilles tendon (AT), the superior cortex of the calcaneus and Flexor Hallucis Longus (FHL) muscle & tendon. Although the biomechanical functions of KFP are not yet fully understood, a number of studies suggested that KFP performs important biomechanical roles including assisting in the dynamic lubrication of the AT subtendinous area, protection of AT vascular supply, and load and stress distribution within the retrocalcaneal bursa space. Similar to the knee meniscus, KFP has become under increasing investigations since strong indications were found that it serves more than just a space filler. Both KFP and the knee meniscus are anchored to their surrounding tissues via fibrous attachments, they can be found in encapsulated (or ‘air tight’) regions, lined by synovial membranes, and they both slide within their motion ranges. The protruding wedge (PW) of KFP was observed to slide in and out of the retrocalcaneal bursal space during ankle plantarflexion and dorsiflexion, respectively. In-vitro studies of KFP suggest that it reduces the load by 39%, which is similar to that of the knee meniscus (30%-70% of the load applied on the knee joint). This study investigated the in-vivo load
Introduction. Alumina ceramic-on-highly cross-linked polyethylene bearings (Al-on-X-linked PE) are attractive because of the potential for reduced wear, osteolysis and loosening of the component. The purpose of this study was to evaluate the clinical and radiographic outcomes of cementless total hip arthroplasties (THAs) using an Al-on-X-linked PE
The combination of natural polymers with calcium phosphate cements (CPCs) by mimicking the highly mineralized collagen-based matrix of native bone is crucial in order to obtain mechanically compatible injectable bone substitute (IBS) formulations. This combination overcomes the drawbacks of CPCs like high resorbability, poor mechanical properties, and degradability. In this study, methylcellulose (MC) was combined with CPCs because of MC's thermoresponsive behavior which makes MC suitable for IBS application. In addition, gelatin (GEL) was also incorporated to adjust the gelation temperature and to enhance cell adhesion. These polymers combination makes the liquid (L) phase. The powder (P) phase comprised of tetra calcium phosphate (TTCP), dicalcium phosphate dehydrates (DCPD), and calcium sulfate dehydrates (CSD). TTCP and DCPD are commonly studied for the development of bone cements and they lead to high-density products. CSD was added to the powder phase to increase the porosity as well as to enhance mechanical properties of the IBS. TTCP was synthesized using a solid state method. Test tube inversion method was used to adjust the gelation temperature. GEL concentration was kept constant at 5 wt% and MC concentration varied between 1.5 and 12 wt%. The weight fraction of P/L phase was used as 1.8:1 (wt/wt). Synthesized IBS was characterized by using X-Ray Diffraction (XRD), Fourier Transform Infrared Analysis (FTIR), Zeta Particle Size Analysis, rheometry, and thermogravimetric analysis. XRD and FTIR analysis proved that TTCP was successfully synthesized with a particle size of 430.1 nm. The particle size of P phase mixture was measured as 581.1 nm. Based on the test tube inversion tests, weight fraction of MC was chosen as 10 and 12 while the weight fraction of GEL was fixed as 5. FTIR spectra of the liquid phase was showed that there was a hydrophilic interaction between MC and GEL since both Amide I at 1633 cm−1 and β-gylcosides bonds among saccharide units at 900–1230 cm−1 were clearly seen. MC10GEL5/P and MC12GEL5/P were analyzed by the XRD. According to this analysis, only the peaks of TTCP, DCPD, and CSD were observed. From the rheological data obtained from the rheometer, it is evident that all the prepared formulations exhibited Newtonian flow. The measured viscosity of all the investigated formula remained constant with the applied force over time. The MC12GEL5/P had the highest viscosity value due to its high concentration of MC (12% w/v). Results of TG of the synthesized IBS showed two main decomposition steps for the L phase because of the hydrophilic interaction between MC and GEL. The synthesized self-crosslinkable IBS represent promising platforms for future studies in bone tissue engineering. Overall, the presented study identified a novel IBS with suitable viscoelastic properties for non-invasive treatment of bone defects which may ultimately be a substitute for surgery for a wide variety of therapeutic applications.
Using a weight-bearing force control task, age-related changes in muscle action were observed in osteoarthritic subjects, however, greater activation of rectus femoris and medial hamstring muscles in the OA group compared to control indicates greater cocontraction and varied stabilisation strategies. Osteoarthritis (OA) is the most debilitating condition among older adults. OA is thought to be mechanically driven by altering the stabilising integrity of the joint. The main contributor to knee joint stability is that of muscular contraction. In cases where the history of a traumatic knee joint injury is not a causal factor, a change in muscle function, resulting in reduced strength and force control in believed to induce OA development and progression. Since age is also a determining factor of OA, the purpose of this study was to investigate the muscle activation patterns of young healthy adults (YC), older healthy adults (OC), and adults with OA during a standing isometric force control task.Summary Statement
Introduction
Metal-on-metal hip resurfacing prostheses are a relatively recent intervention for relieving the symptoms of common musculoskeletal diseases such as osteoarthritis. While some short term clinical studies have offered positive results, in a minority of cases there is a recognised issue of femoral fracture, which commonly occurs in the first few months following the operation. This problem has been explained by a surgeon's learning curve and notching of the femur but, to date, studies of explanted early fracture components have been limited. Tribological analysis was carried out on fourteen retrieved femoral components of which twelve were revised after femoral fracture and two for avascular necrosis (AVN). Eight samples were Durom (Zimmer, Indiana, USA) devices and six were Articular Surface Replacements (ASR, DePuy, Leeds, United Kingdom). One AVN retrieval was a Durom, the other an ASR. The mean time to fracture was 3.4 months. The AVNs were retrieved after 16 months (Durom) and 38 months (ASR). Volumetric wear rates were determined using a Mitutoyo Legex 322 co-ordinate measuring machine (scanning accuracy within 1 micron) and a bespoke computer program. The method was validated against gravimetric calculations for volumetric wear using a sample femoral head that was artificially worn in vitro. At 5mm3, 10mm3, and 15mm3 of material removal, the method was accurate to within 0.5mm3. Surface roughness data was collected using a Zygo NewView500 interferometer (resolution 1nm). Mean wear rates of 17.74mm3/year were measured from the fracture components. Wear rates for the AVN retrievals were 0.43mm3/year and 3.45mm3/year. Mean roughness values of the fracture retrievals (PV = 0.754nm, RMS = 0.027nm) were similar to the AVNs (PV = 0.621nm, RMS = 0.030nm), though the AVNs had been in vivo for significantly longer. Theoretical lubrication calculations were carried out which found that in both AVN retrievals and in seven of the twelve cases of femoral fracture the roughening was sufficient to change the lubrication regime from fluid film to mixed. Three of these surfaces were bordering on the boundary lubrication regime. The results show that even before the femoral fracture, wear rates and roughness values were high and the implants were performing poorly.
Articular cartilage (AC) and subchondral bone (SB) are intimately intertwined, forming a complex unit called the AC-SB interface. Our recent studies have shown that cartilage and bone marrow are connected by a three-dimensional network of microchannels (i.e. cartilage-bone marrow microchannel connector; CMMC), which differ microarchitecturally in number, size and morphology depending on the maturation stage of the bone and the region of the joint. However, the pathological significance of CMMC is largely unknown. Here, we quantitatively assessed how CMMC microarchitecture relates to cartilage condition and regional differences in early idiopathic osteoarthritis (OA). Two groups of cadaveric female human femoral heads (intact cartilage vs early cartilage lesions) were identified and biopsy-based high-resolution micro-CT imaging was used. Subchondral bone (SB) thickness, CMMC number, maximum and minimum CMMC size, and CMMC morphology were quantified and compared between the two groups. The effect of joint region and cartilage condition on each dependent variable was examined. The number and morphology of CMMCs were influenced by the region of the joint, but not by the cartilage condition. On the other hand, the minimum and maximum CMMC size was modified by both joint location and cartilage condition. The smallest CMMCs were consistently found in the load