Advertisement for orthosearch.org.uk
Results 1 - 20 of 201
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 83 - 83
11 Apr 2023
Khojaly R Rowan F Nagle M Shahab M Shah V Dollard M Ahmed A Taylor C Cleary M Niocaill R
Full Access

Is Non-Weight-Bearing Necessary? (INWN) is a pragmatic multicentre randomised controlled trial comparing immediate protected weight-bearing (IWB) with non-weight-bearing cast immobilisation (NWB) following ankle fracture fixation (ORIF). This trial compares; functional outcomes, complication rates and performs an economic analysis to estimate cost-utility.

IWB within 24hrs was compared to NWB, following ORIF of all types of unstable ankle fractures. Skeletally immature patients and tibial plafond fractures were excluded. Functional outcomes were assessed by the Olerud-Molander Ankle Score (OMAS) and RAND-36 Item Short Form Survey (SF-36) taken at regular follow-up intervals up to one year. A cost-utility analysis via decision tree modelling was performed to derive an incremental cost effectiveness ratio (ICER). A standard gamble health state valuation model utilising SF-36 scores was used to calculate Quality Adjusted Life Years (QALYs) for each arm.

We recruited 160 patients (80 per arm), aged 15 to 94 years (M = 45.5), 54% female. Complication rates were similar in both groups. IWB demonstrated a consistently higher OMAS score, with significant values at 6 weeks (MD=10.4, p=0.005) and 3 months (MD 12.0, p=0.003). Standard gamble utility values demonstrated consistently higher values (a score of 1 equals perfect health) with IWB, significant at 3 months (Ẋ = 0.75 [IWB] / 0.69 [NWB], p=0.018). Cost-utility analysis demonstrated NWB is €798.02 more expensive and results in 0.04 fewer QALYs over 1 year. This results in an ICER of −€21,682.42/QALY. This negative ICER indicates cost savings of €21,682.42 for every QALY (25 patients = 1 QALY gain) gained implementing an IWB regime.

IWB demonstrates a superior functional outcome, greater cost savings and similar complication rates, compared to NWB following ankle fracture fixation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 20 - 20
1 Dec 2021
Yang I Gammell JD Murray DW Mellon SJ
Full Access

Abstract. Background. The Oxford Domed Lateral (ODL) Unicompartmental Knee Replacement (UKR) has some advantages over other lateral UKRs, but the mobile bearing dislocation rate is high (1–6%). Medial dislocations, with the bearing lodged on the tibial component wall, are most common. Anterior/posterior dislocations are rare. For a dislocation to occur distraction of the joint is required. We have developed and validated a dislocation analysis tool based on a computer model of the ODL with a robotics path-planning algorithm to determine the Vertical Distraction required for a Dislocation (VDD), which is inversely related to the risk of dislocation. Objectives. To modify the ODL design so the risk of medial dislocation decreases to that of an anterior/posterior dislocation. Methods. The components were modified using Solidworks. For each modification the dislocation analysis tool was used to determine the VDD for medial dislocation (with bearing 0–6mm from the tibial wall). This was compared with the original implant to identify the modifications that were most effective at reducing the dislocation risk. These modifications were combined into a final design, which was assessed. Results. Modifying the tibial component plateau, changing the femoral component width and making the bearing wider medially had little effect on VDD. Shifting the femoral sphere centre medially decreased VDD. Shifting the femoral sphere laterally, increasing tibial wall height and increasing bearing width laterally increased VDD. A modified implant with a femoral sphere centre 3mm lateral, wall 2.8mm higher, and bearing 2mm wider laterally, implanted so the bearing is ≤4mm from the tibial wall with a bearing thickness ≥4mm had a minimum VDD for medial dislocation of 5.75mm, which is larger than the minimum VDD for anterior/posterior dislocation of 5.5mm. Conclusions. A modified ODL design should decrease the dislocation rate to an acceptable level, however, further testing in cadavers is required. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years. Materials and Methods. A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively. Results. There was a 6.2% (n=28) all-cause and 5.3% (n=24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months − 11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years. Conclusions. This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. The role for CoC bearings in THA has been called into question in recent years and may continue to decline in popularity, even in younger patients. Further large scale studies are important to assess the long-term outcomes of this bearing surface


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 35 - 35
1 Jan 2019
Zaribaf F Gill HR Pegg E
Full Access

Ultra-high molecular weight polyethylene (UHMWPE) is a commonly used as bearing material in joint replacement devices. UHMWPE implants can be hard to see on a standard X-ray because UHMWPE does not readily attenuate X-rays. Radiopaque UHMWPE would enable direct imaging of the bearing both during and after surgery, providing in vivo assessment of bearing position, dislocation or fracture, and potentially a direct measure of wear. The X-ray attenuation of UHMWPE was increased by diffusing an FDA approved contrast agent (Lipiodol) into UHMWPE parts (Zaribaf et al, 2018). The aim of this study was to evaluate the optimal level of radiopacity for a UHMWPE bearing. Samples of un-irradiated medical grade UHMWPE (GUR 1050) were machined into 4mm standard medium Oxford Unicompartmental bearings. Samples were immersed in Lipiodol Ultra Fluid (Guerbert, France) at elevated temperatures (85 °C, 95 °C and 105 °C) for 24 h to achieve three different levels of radiopacity. A phantom set-up was used for X-ray imaging; the phantom contained two perspex rods to represent bone, with the metallic tibial tray and polyethylene bearing fixed to the end of one rod and the metallic femoral component fixed to the other rod. Radiographs of the samples were taken (n=5) with the components positioned in full extension. To ensure consistency, the images of all the samples were taken simultaneously alongside an untreated part. The results of our ongoing study demonstrate that the radiopacity of UHMWPE can be enhanced using Lipiodol and the parts are visible in a clinical radiographs. The identification of the optimal treatment from a clinical perspective is ongoing; we are currently running a survey with clinicians to find the consensus on the optimal radiopacity taking into account the metallic components and alignment. Future work will involve a RSA study to assess the feasibility of measuring wear directly from the bearing


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 59 - 59
1 May 2012
Simpson DJ Kendrick B Thomas G Gill H O'Connor J Murray DW
Full Access

Introduction. The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Methods. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the joint space (M-L); anterior to posterior dislocation, out of the joint space (A-P). A size C tray and a medium femoral component and bearing were used in all models. The femoral component, tibial tray and bearing were first aligned in a neutral position. For each dislocation the tibial tray was restrained in all degrees of freedom. The femoral component was restrained from moving in the anterior-posterior directions and in the medial-lateral directions. The femoral component was also restrained from rotating about the anterior-posterior, medial-lateral and superior-inferior directions. This meant that the femoral component was only able to move in the superior-inferior direction. Different bearing sizes were inserted into the model and the effect that moving the femoral component medially and laterally had on the amount of distraction required to cause bearing dislocation was investigated. Results. The average femur distraction to allow bearing dislocation in the A-P, M-L and L-M-wall directions was 1.62 mm (27%), 0.51 mm (26%) and 1.2 mm (24%) greater respectively for the domed bearing. There was a 3% increase in femoral distraction required to cause L-M-Wall dislocation, per increment of bearing thickness for both the domed and lateral bearings. There was on average a 7% increase in femoral distraction required to cause L-M-Wall dislocation per mm increment of medial femoral component movement. Discussion. Dislocation over the tray wall is a particular clinical problem and using a domed bearing can lead to an increased required femoral distraction of between 25% and 37%. This may be significant during everyday activities and demonstrates that the new domed design should reduce the incidence of bearing dislocation by increasing the amount of entrapment. Increasing the thickness of the bearing has a small effect on the distraction required to allow bearing dislocation. Lateral placement of the femoral component markedly reduced the femoral distraction required for bearing dislocation over the tray wall. Medial placement of the femoral component is advisable so long as impingement with the tray wall is avoided


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 54 - 54
1 Jan 2017
Etani Y
Full Access

UKA with mobile bearing is a one of the treatment of medial osteoarthritis. However, some reports refer to the risk of dislocation of the mobile bearing. Past reports pointed out that medial gap might be enlarged in deep flexion position (over 120 degrees), and says that it will lead to instability of the mobile bearing. The purpose of this study is to research the risk factors of enlargement of medial gap in deep flexion position. We performed 81 UKAs with mobile bearing system from November 2013 to December 2015, and could evaluate 41 knees. This study of 41 knees included 9 males and 32 females, with average operation age of 75.4years(63–89years). The diagnosis was osteoarthritis in 39 knees and osteonecrosis in 2 knees. The UKA(Oxford partial knee microplasty, Biomet, Warsaw, IN) was used in all cases. We performed distal femur and proximal tibia osteotomy using CT-Free navigation system(Stryker Navigation System II/precision Knee Navigation ver4.0). And we inserted femoral and tibial trial component, then we placed an UKA tensioner on the medial component of the knee. Using tensioner under 30 lbs, we measured joint medial gap at 0,20,45,90,130(deep flexion) degrees. When we compared medial gap at 90 degrees position with at 130 degrees, we defined it as ‘instability group’ if there was gap enlargement more than 1mm, and defined it as ‘stability group’ if there wasn't. We compared this two groups with regard to age, BMI, femoro-tibial angle (FTA), the diameter of anterior cruciate ligament (ACL), tibial angle and tibial posterior slope angle of the implant. We evaluated preoperative and postoperative FTA by weightbearing long leg antero-posterior alignment view X-rays. We measured ACL diameter at its condyle level in coronal view of MRI. Also we evaluated tibial component implantation angle by postoperative CT using 3D template system. These measurement were analyzed statistically using t test. The stability group contained 26 knees, and the instability group contained 15 knees. Compared with the stability group, the instability group indicated higher FTA (p=0.001). Between 20 and 90 degrees flexion position, there was no change of medial gap. Dislocation of the mobile bearing is one of the complications of UKA and it will need re-operation. It is said to be caused by impingement of the bearing and osteophyte of femur. However, some reports said that dislocation was happened when the knee was flexed deeply or twisted, and there was no impingement. We think it may means that dislocation could be caused by medial gap enlargement. This study indicates that higher FTA could be risk factor of dislocation of mobile bearing. It is important to evaluate preoperatively FTA by X-ray


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 102 - 102
1 Nov 2018
Waddell J
Full Access

We have undertaken a series of clinical trials over the last 20 years to look at different bearing surface combinations in young adults. We continue to follow these patients well beyond the planned duration of the trials and new information is constantly becoming available. The first trial compared ceramic-on-ceramic with ceramic-on-standard-polyethylene. These patients have now been followed for 20 years with significant wear in the polyethylene group but virtually identical revision rates. The second trial ceramic-on-ceramic, cobalt-chrome-on-standard-polyethylene and cobalt-chrome-on-cross-linked-polyethylene. In this group the ceramic-on-ceramic patients have the lowest revision rate; the ceramic-on-polyethylene group demonstrates a lower wear rate than cobalt-chrome-on-polyethylene. The third trial looks at cobalt-chrome versus zirconium on either cross-linked polyethylene or conventional polyethylene. At 10 years there remains no evidence of improved performance from the zirconium surface as compared to cobalt-chrome. The cross-linked polyethylene group is clearly outperforming the conventional polyethylene in terms of wear rate but at 10 years the revision rates remain the same in all groups. Cross liked polyethylene appears to be the major determining factor in prosthetic longevity and appears to be more important than the counter face material


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 19 - 19
1 Apr 2017
Corrado P Alan P Michael S
Full Access

Background. As the number of ceramic THR bearings used worldwide is increasing, the number of implants that experience off-normal working conditions, e.g. edge loading, third bodies in the joint, soft tissues laxity, dislocation/subluxation of the joint, increases too. Under all such conditions the bearing surfaces can be damaged, leading eventually to a limitation of the expected performances of the implant. Methods. We characterised the damage resistance of different bearing surfaces (alumina matrix composite BIOLOXdelta, alpha-alumina BIOLOXforte, zirconia 3Y-TZP, oxidized zirconium alloy Zr-2.5Nb, CoCr-alloy) by scratch tests performed following the European standard EN 1071–3:2005. Also the scratch hardness of same materials has been assessed. Results. The Lc1 value (i.e., the load for the onset of a scratch) measured for BIOLOXdelta is about fivefold the one measured for the oxidized zirconium alloy (OXZr) surface and about tenfold the Lc1 measured for the CoCr alloy. The height of ridges along the scratch edges due to plastic flow in the composite ceramic BIOLOXdelta are only 21% in height than in CoCr, and only a small fraction (0.04%) of the height of ridges measured on OXZr surfaces. The scratch hardness of the metal samples tested (CoCr, OXZr) results one order of magnitude lower than the ones of ceramics. This behavior is not influenced by of the presence of the coating on OXZr surface. Conclusions. The transformation toughened ceramics tested (BIOLOXdelta, 3Y-TZP) are the materials that exhibit the higher resistance to scratching. Ridges at scratch edges are lower in ceramics than in coated or uncoated metals. The result show the superior scratch resistance behavior of toughened ceramics for THR wear couples with respect to coated or bare alloys. Level of Evidence. Level 1


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 7 - 7
1 Jul 2014
Brockett C Carbone S Jennings L Fisher J
Full Access

Summary Statement. Wear of total knee replacement (TKR) is a clinical concern. This study demonstrated low-conformity moderately cross-linked-polyethylene fixed bearing TKRs showed lower volumetric wear than conventional-polyethylene curved fixed bearing TKRs highlighting potential improvement in TKR performance through design and material selection. Introduction. Wear of total knee replacement (TKR) continues to be a significant factor in the clinical performance of the implants. Historically, failure due to delamination and fatigue directed implant design towards more conforming implants to reduce contact stress. However, the new generations of more oxidatively-stable polyethylene have improved the long-term mechanical properties of the material, and therefore allowed more flexibility in the bearing design. The purpose of this study was to investigate the effect of insert conformity and material on the wear performance of a fixed bearing total knee replacement through experimental simulation. Methods. The wear of TKR bearings were investigated using a physiological six station Prosim knee wear simulator (Simulator Solutions, UK). Six samples of each test configuration (Sigma CR fixed bearing knees (DePuy Synthes, UK) were studied, and compared with previously reported data, tested under identical conditions (1, 2). The central axis of the implant was offset from the aligned axes of applied load and tibial rotation to replicate a right knee. High kinematics, under anterior-posterior displacement control was used for this study (3). The lubricant was 25% (v/v) calf serum supplemented with 0.03% (v/v) sodium azide solution in deionised water, as an antibacterial agent, and was changed approximately every 0.33Mc. Wear was assessed gravimetrically and moisture uptake accounted for using unloaded soak controls. Results. The wear rates for the moderately cross-linked inserts (XLK) were significantly lower than the conventional polyethylene (GVF) for all geometries (ANOVA, p<0.05). There was a significant reduction in wear rate as the insert geometry became less conforming for both materials (ANOVA, p<0.05). The wear scars areas were comparable in size and shape between materials, within a geometry group. The size of the wear scar changed with conformity, with the curved inserts showing the largest scars in both anterior-posterior and medial-lateral dimensions, and the flat inserts showing the smallest wear scars. Discussion/Conclusion. The introduction of a moderately cross-linked polyethylene insert was shown to significantly reduce the wear of a fixed bearing total knee replacement compared with a conventional material. There was a trend for reducing wear rate with reducing conformity for both materials, suggesting that reduced conformity results in higher contact pressures and reduced contact area, leading to a reduced surface for wear to occur. Both material and conformity were shown to have a significant impact on the wear of a fixed bearing TKR, and therefore provide opportunity for enhancing wear performance through material and design selection


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 68 - 68
1 Nov 2018
Sánchez-Abella L Loinaz I Grande H Dupin D
Full Access

In 2011, approximately 1.6 million total hip arthroplasties (THAs) were conducted in 27 of the 34 member countries in the Organization for Economic Cooperation and Development (OECD) However, approximately 10–15% of patients still require revision surgery every year. Therefore, new technologies are required to increase the life-spam of the prosthesis from the current 10–15 years to at least 20–30 years. Our strategy focuses on surface modification of the bearing materials with a hydrophilic coating to improve their wear behaviour. These coatings are biocompatible, with high swelling capacity and antifouling properties, mimicking the properties of natural cartilage, i.e. wear resistance with permanent hydrated layer that prevents prosthesis damage. Clear beneficial advantages of this coating have been demonstrated in different conditions and different materials, such as UHMWPE, PEEK, CrCo, Stainless steel, ZTA and Alumina. Using routine tribological experiments, the wear for UHMWPE substrate was decreased by 75% against alumina, ZTA and stainless steel. For PEEK-CFR substrate coated, the amount of material lost against ZTA and CrCo was at least 40% lower. Further experiments on hip simulator adding abrasive particles (1-micron sized aluminium particles) during 3 million cycles, on a total of 6 million, showed a wear decreased of around 55% compared to uncoated UHMWPE and XLPE. In conclusion, CIDETEC‘s coating technology is versatile and can be adapted to protect and improve the tribological properties of different types of surfaces used for prosthesis, even in abrasive conditions


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 44 - 44
1 Apr 2018
Bernstein A Reichert A Weichand P Gadow R Südkamp NP Mayr HO
Full Access

To date there has been no material for endoprosthetics providing excellent resistance to abrasion and corrosion combined with great tensile strength, fracture toughness, and bending strength, as well as adequate biocompatibility. Carbon-fiber-reinforced silicon carbide (C/SiC, C/C-SiC or C/SiSiC) is as a ceramic compound a potentially novel biomaterial offering higher ductility and durability than comparable oxide ceramics. Aim of this investigation was to test the suitability of C/SiC ceramics as a new material for bearing couples in endoprosthetics. One essential quality that any new material must possess is biocompatibility. For this project the in-vitro biocompatibility was investigated by using cuboid like scaffolds made of CMC. To determine whether the material is suited as a lubricant partner in endoprosthetics, we measured its abrasion coefficient and wear tolerance against various antibodies. The C/SiC samples tested were produced via the Liquid Silicon Infiltration (LSI) of pyrolized porous fiber preforms made by warm-flow pressing free-flowing granulates on a hydraulic downstroking press with a heated die of the type HPS-S, 1000 kN. After preparation of the composites, the tribological characteristics are determined. Flexural strength was determined at room temperature according to DIN685-3 with an universal testing machine Z100 and the Young”s -modulus was carried out via resonant frequency-damping analysis RFDA. The samples”surface as well as cell adhesion and cell morphology were assessed via ESEM. The human osteoblast-like cell line MG-63 and human ostoeblast were used for cel culture ecperiments (WST, Live/dead, Cytotoxicity, cell morphology). Based on the raw data the mean value and the standard deviation were calculated. The Mann-Whitney-U-Test was used to evaluate the differences between experiment and control samples. The flexural strength at room temperature is approx. 180 MPa, while the elongation at break is about 0.13%. The Young”s modulus is detected between 120 and 150 GPa. The density lies between 2.5 and 3.0 g/cm. 3. We noted a friction coefficient µ between 0.31. The cell lines exhibited no morphological alterations, and adhered well to the C/SiC samples. Vitality was not impaired by contact with the ceramic composite. Cell growth was observed evenly distributed over a 21-day period. In the future, investigators aiming to apply this composite in endoprosthetics will have to focus on its efficacy in conjunction with sudden, strong demands, and long-term performance in bodily fluids within joint simulators, etc. In conclusion: C/SiC can definitely be considered a new material with genuine potential for use in endoprosthetics


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 107 - 107
1 Nov 2018
Sheridan G Kelly R McDonnell S Kenny P
Full Access

This was a retrospective study of registry data from a National Orthopaedic Hospital for all THRs with 10-year follow-up data. Inclusion criteria were all THRs with a minimum of 10-year follow-up data. All metal-on-metal (MoM) THRs and MoM resurfacings were excluded from the analysis due to the high rate of revision associated with these bearings. Univariate and multivariate analyses controlling for confounding variables were performed to compare outcomes. A total of 1,697 THRs were performed in 1,553 patients. The four significant predictors for revision were fixation type (p<0.01), surface bearing type (p<0.01), age (P<0.05) and head size (p<0.05). Gender, BMI and approach had no effect on revision rates. The lowest 10-year all-cause revision rates were seen in cemented THRs at 1.7%. Ceramic-on-poly bearings had the lowest revision rate at only 1.2%. Metal-on-poly bearings had a 1.7% revision rate. Ceramic on ceramic bearings had a 7.1% revision rate with 1 revision for squeak and 1 revision for ceramic head fracture. The causes for revision in order of decreasing frequency were as follows: Infection (n=13, 0.7%), dislocation (n=7, 0.4%), periprosthetic fracture (n=3, 0.2%) and aseptic loosening (n=2, 0.1%). There were 2 re-revisions at 10 years in total. The smaller 22.225mm head sizes had a significantly lower revision rate than other head sizes (p<0.05). Ceramic-on-poly bearings, cemented fixation and smaller head sizes perform better in the experience of this registry. However, with multivariate analysis, these differences were shown to be insignificant


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_17 | Pages 20 - 20
1 Apr 2013
Breen A Mellor F Breen A
Full Access

Study Purpose. A preliminary study to compare continuous sagittal plane lumbar inter-vertebral kinematics in 10 healthy volunteers in recumbent and weight bearing configurations using quantitative fluoroscopy. Background. There are no direct in-vivo comparisons between continuous weight bearing and non-weight bearing inter-vertebral kinematics in the same healthy individuals. This information will advance our knowledge of spine mechanics and provide reference values for clinical studies. Methods. Ten male healthy control volunteer subjects aged between 30 and 50 underwent a recumbent bending procedure during fluoroscopy. All participants repeated this in weight bearing. Trunk motion was controlled for range and velocity. Digital image sequences (DICOM) of these movements were captured at 15 fps and analysed using automated frame to frame image registration codes in MATLAB (Mathworks). Inter-vertebral motion characteristics, including inter-vertebral angular range of rotation and attainment rate (Laxity), were calculated. Results. These results are the preliminary output of an ongoing study to create a reference database for normal spine kinematics. Comparisons of the motion patterns within and between participants will be demonstrated along with preliminary statistical analysis of range of motion and speed of attainment (laxity) of the angular range within the first 10° of trunk motion after the inter-vertebral motion starts. Laxity is proposed as a new in vivo proxy for the neutral zone where force is replaced by trunk motion near the neutral position. Conclusion. These preliminary comparisons demonstrate the feasibility of establishing a reference database of lumbar spine kinematics to which patient populations can be compared, potentially allowing these to emerge as outcome measures. No conflicts of interest. Sources of funding: PhD studentship: School of Design Engineering and Computing, Bournemouth University. This abstract has not been previously published in whole or substantial part nor has it been presented previously at a national meeting


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 33 - 33
1 Aug 2013
Bell S Mullen M Leach W Rooney B
Full Access

We report the short term follow up of nineteen consecutive PFC sigma unicompartmental knee replacements carried out in our institution with minimum one year follow up. The PFC Sigma medial unicompartmental knee replacement is a fixed bearing, cemented unicompartmenal knee replacement. There are currently no published reports of follow up for the PFC Sigma medial unicompartmental knee replacement. Nineteen patients (nineteen knees) underwent PFC sigma medial unicompartmental knee arthroplasty. The pre-operative diagnosis was osteoarthritis in eighteen patients and osteonecrosis in one patient. There were ten males and nine females with a mean age of sixty four years. All patients had clinical and radiological review at one year. All operations were carried out by the two senior authors (BPR and BL). The mean length of admission was 2.7 days (Range 2–5). There have been no infective or thromboembolic complications to date. The mean oxford scores improved from 41 (Range 26–52) pre-operatively to 18 (15–27) at one year follow-up. The mean range of motion improved from 115 degrees of flexion preoperatively to 125 degrees. All radiographs were satisfactory at one year follow up with no evidence of loosening. We report the promising early results of a new medial unicompartmental knee replacement with at least one year follow up. No early complications or infections were identified in our cohort of patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 58 - 58
1 May 2012
Ghazzawi AA Nokes L Byrne C
Full Access

Introduction. Kager's fat pad (KFP) is located in Kager's triangle between the Achilles tendon (AT), the superior cortex of the calcaneus and Flexor Hallucis Longus (FHL) muscle & tendon. Although the biomechanical functions of KFP are not yet fully understood, a number of studies suggested that KFP performs important biomechanical roles including assisting in the dynamic lubrication of the AT subtendinous area, protection of AT vascular supply, and load and stress distribution within the retrocalcaneal bursa space. Similar to the knee meniscus, KFP has become under increasing investigations since strong indications were found that it serves more than just a space filler. Both KFP and the knee meniscus are anchored to their surrounding tissues via fibrous attachments, they can be found in encapsulated (or ‘air tight’) regions, lined by synovial membranes, and they both slide within their motion ranges. The protruding wedge (PW) of KFP was observed to slide in and out of the retrocalcaneal bursal space during ankle plantarflexion and dorsiflexion, respectively. In-vitro studies of KFP suggest that it reduces the load by 39%, which is similar to that of the knee meniscus (30%-70% of the load applied on the knee joint). This study investigated the in-vivo load bearing functionality of KFP. Materials and Methods. The ankles of 5 volunteers (3 males, 2 females, Age 20-28, BMI 21-26) were scanned using a 0.2T MRI scanner at ankle plantarflexion and neutral positions. The ankles of 2 of those volunteers were later scanned using a 3T MRI scanner for higher accuracy. The areas and volumes of KFP were measured using Reconstruct¯ 3D modelling software. The hind foot of the volunteers were scanned using dynamic ultrasound to measure in-vivo real time shape changes of PW. Results. The cross sectional area of KFP in the AT midline saggital plane increased on average by 10% when ankles were changed from neutral to plantarflexion positions. The volume of KFP showed less variation than cross sectional areas (3.9% variation in volume). Previous studies showed the cross sectional area of the knee meniscus changes by 9.8% during loading, or flexing the knee by 90°, and its volume was reduced by 3.5%-5.9% (medial and lateral menisci respectively). Ultrasound imaging showed that PW's thickness decreased during dorsiflexion compared to plantarflexion by an average of 1mm and a hysteresis was found between the location of PW's tip and the insertion angle of AT, suggesting the fibrous tip of PW bears load during dorsiflexion. Discussions and conclusions. The similarities in results between the knee meniscus (literature review) and KFP supports hypotheses that KFP assists in reducing the load applied at the AT enthesis organ. Furthermore, histological studies showed a fibrosis is evident at the tip of PW, which is thought to be developed as a result of resisting external loading. This also supports speculations that KFP removal is likely to reduce lubrication, pressure distribution, load bearing, and consequently, increasing the tear and wear level within AT enthesis


Introduction. Alumina ceramic-on-highly cross-linked polyethylene bearings (Al-on-X-linked PE) are attractive because of the potential for reduced wear, osteolysis and loosening of the component. The purpose of this study was to evaluate the clinical and radiographic outcomes of cementless total hip arthroplasties (THAs) using an Al-on-X-linked PE bearing and to determine the rates of osteolysis using radiographs and computer tomographic (CT) scans in young patients with osteonecrosis of femoral head. Methods. Consecutive primary cementless THAs using Al-on-X-linked PE bearing were performed in 71 patients (73 hips) who were younger than 50 years of age with osteonecrosis of the femoral head. There were 48 men (51 hips) and 23 women (23 hips). The average age at the time of the index arthroplasty was 46 years (range, 20 to 50 years). Osteolysis was evaluated using radiographs and CT scanning. The average follow-up was 11 years (range, 10 to 13 years). Results. The mean preoperative Harris hip score was 51 points (range, 27 to 55 points), which was improved to 96 points (range, 85 to 100 points) at the final follow-up. Preoperative functional activity was improved significantly (p=0.001) at the latest follow-up. All acetabular and femoral components were fixed by bone ingrown. The mean polyethylene linear penetration was 0.05 ?0.02 mm per year (range, 0.02 mm to 0.08 mm per year). Radiographic and CT scan evaluation demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up. Conclusion. The current generation of anatomic tapered cementless femoral component with Al-on-X-linked PE bearing is functioning well with no osteolysis at a 10-year minimum and average of 11-year follow-up in this series of young patients with osteonecrosis of the femoral head


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 22 - 22
1 Apr 2018
Oğuz ÎD Ege D
Full Access

The combination of natural polymers with calcium phosphate cements (CPCs) by mimicking the highly mineralized collagen-based matrix of native bone is crucial in order to obtain mechanically compatible injectable bone substitute (IBS) formulations. This combination overcomes the drawbacks of CPCs like high resorbability, poor mechanical properties, and degradability. In this study, methylcellulose (MC) was combined with CPCs because of MC's thermoresponsive behavior which makes MC suitable for IBS application. In addition, gelatin (GEL) was also incorporated to adjust the gelation temperature and to enhance cell adhesion. These polymers combination makes the liquid (L) phase. The powder (P) phase comprised of tetra calcium phosphate (TTCP), dicalcium phosphate dehydrates (DCPD), and calcium sulfate dehydrates (CSD). TTCP and DCPD are commonly studied for the development of bone cements and they lead to high-density products. CSD was added to the powder phase to increase the porosity as well as to enhance mechanical properties of the IBS. TTCP was synthesized using a solid state method. Test tube inversion method was used to adjust the gelation temperature. GEL concentration was kept constant at 5 wt% and MC concentration varied between 1.5 and 12 wt%. The weight fraction of P/L phase was used as 1.8:1 (wt/wt). Synthesized IBS was characterized by using X-Ray Diffraction (XRD), Fourier Transform Infrared Analysis (FTIR), Zeta Particle Size Analysis, rheometry, and thermogravimetric analysis. XRD and FTIR analysis proved that TTCP was successfully synthesized with a particle size of 430.1 nm. The particle size of P phase mixture was measured as 581.1 nm. Based on the test tube inversion tests, weight fraction of MC was chosen as 10 and 12 while the weight fraction of GEL was fixed as 5. FTIR spectra of the liquid phase was showed that there was a hydrophilic interaction between MC and GEL since both Amide I at 1633 cm−1 and β-gylcosides bonds among saccharide units at 900–1230 cm−1 were clearly seen. MC10GEL5/P and MC12GEL5/P were analyzed by the XRD. According to this analysis, only the peaks of TTCP, DCPD, and CSD were observed. From the rheological data obtained from the rheometer, it is evident that all the prepared formulations exhibited Newtonian flow. The measured viscosity of all the investigated formula remained constant with the applied force over time. The MC12GEL5/P had the highest viscosity value due to its high concentration of MC (12% w/v). Results of TG of the synthesized IBS showed two main decomposition steps for the L phase because of the hydrophilic interaction between MC and GEL. The synthesized self-crosslinkable IBS represent promising platforms for future studies in bone tissue engineering. Overall, the presented study identified a novel IBS with suitable viscoelastic properties for non-invasive treatment of bone defects which may ultimately be a substitute for surgery for a wide variety of therapeutic applications.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 166 - 166
1 Jul 2014
Flaxman T Smith A Benoit D
Full Access

Summary Statement

Using a weight-bearing force control task, age-related changes in muscle action were observed in osteoarthritic subjects, however, greater activation of rectus femoris and medial hamstring muscles in the OA group compared to control indicates greater cocontraction and varied stabilisation strategies.

Introduction

Osteoarthritis (OA) is the most debilitating condition among older adults. OA is thought to be mechanically driven by altering the stabilising integrity of the joint. The main contributor to knee joint stability is that of muscular contraction. In cases where the history of a traumatic knee joint injury is not a causal factor, a change in muscle function, resulting in reduced strength and force control in believed to induce OA development and progression. Since age is also a determining factor of OA, the purpose of this study was to investigate the muscle activation patterns of young healthy adults (YC), older healthy adults (OC), and adults with OA during a standing isometric force control task.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 77 - 77
1 Aug 2012
Lord J Langton D Nargol A Meek R Joyce T
Full Access

Metal-on-metal hip resurfacing prostheses are a relatively recent intervention for relieving the symptoms of common musculoskeletal diseases such as osteoarthritis. While some short term clinical studies have offered positive results, in a minority of cases there is a recognised issue of femoral fracture, which commonly occurs in the first few months following the operation. This problem has been explained by a surgeon's learning curve and notching of the femur but, to date, studies of explanted early fracture components have been limited.

Tribological analysis was carried out on fourteen retrieved femoral components of which twelve were revised after femoral fracture and two for avascular necrosis (AVN). Eight samples were Durom (Zimmer, Indiana, USA) devices and six were Articular Surface Replacements (ASR, DePuy, Leeds, United Kingdom). One AVN retrieval was a Durom, the other an ASR. The mean time to fracture was 3.4 months. The AVNs were retrieved after 16 months (Durom) and 38 months (ASR).

Volumetric wear rates were determined using a Mitutoyo Legex 322 co-ordinate measuring machine (scanning accuracy within 1 micron) and a bespoke computer program. The method was validated against gravimetric calculations for volumetric wear using a sample femoral head that was artificially worn in vitro. At 5mm3, 10mm3, and 15mm3 of material removal, the method was accurate to within 0.5mm3. Surface roughness data was collected using a Zygo NewView500 interferometer (resolution 1nm).

Mean wear rates of 17.74mm3/year were measured from the fracture components. Wear rates for the AVN retrievals were 0.43mm3/year and 3.45mm3/year. Mean roughness values of the fracture retrievals (PV = 0.754nm, RMS = 0.027nm) were similar to the AVNs (PV = 0.621nm, RMS = 0.030nm), though the AVNs had been in vivo for significantly longer.

Theoretical lubrication calculations were carried out which found that in both AVN retrievals and in seven of the twelve cases of femoral fracture the roughening was sufficient to change the lubrication regime from fluid film to mixed. Three of these surfaces were bordering on the boundary lubrication regime. The results show that even before the femoral fracture, wear rates and roughness values were high and the implants were performing poorly.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 84 - 84
2 Jan 2024
Taheri S Yoshida T Böker KO Foerster R Jochim L Flux A Grosskopf B Hawellek T Lehmann W Schilling A
Full Access

Articular cartilage (AC) and subchondral bone (SB) are intimately intertwined, forming a complex unit called the AC-SB interface. Our recent studies have shown that cartilage and bone marrow are connected by a three-dimensional network of microchannels (i.e. cartilage-bone marrow microchannel connector; CMMC), which differ microarchitecturally in number, size and morphology depending on the maturation stage of the bone and the region of the joint. However, the pathological significance of CMMC is largely unknown. Here, we quantitatively assessed how CMMC microarchitecture relates to cartilage condition and regional differences in early idiopathic osteoarthritis (OA). Two groups of cadaveric female human femoral heads (intact cartilage vs early cartilage lesions) were identified and biopsy-based high-resolution micro-CT imaging was used. Subchondral bone (SB) thickness, CMMC number, maximum and minimum CMMC size, and CMMC morphology were quantified and compared between the two groups. The effect of joint region and cartilage condition on each dependent variable was examined. The number and morphology of CMMCs were influenced by the region of the joint, but not by the cartilage condition. On the other hand, the minimum and maximum CMMC size was modified by both joint location and cartilage condition. The smallest CMMCs were consistently found in the load bearing region (LBR) of the joint. Compared to healthy subjects, the size of the microchannels was increased in early OA, most notably in the non-load bearing region (NLBR) and the peripheral rim (PR) of the femoral head. In addition, subchondral bone thinning was observed in early OA as a localized event associated with areas of partial chondral defect. Our data suggest an enlargement of the SB microchannel network and a collective structural deterioration of the SB in early idiopathic OA