RATES OF OSTEOLYSIS IN WELL-FUNCTIONING ALUMINA-ON-HIGHLY CROSS-LINKED POLYETHYLENE BEARING CEMENTLESS TOTAL HIP ARTHROPLASTY IN PATIENTS YOUNGER THAN FIFTY YEARS WITH FEMORAL HEAD OSTEONECROSIS

Yokohama, Japan, November 2009 meeting



Abstract

Introduction

Alumina ceramic-on-highly cross-linked polyethylene bearings (Al-on-X-linked PE) are attractive because of the potential for reduced wear, osteolysis and loosening of the component. The purpose of this study was to evaluate the clinical and radiographic outcomes of cementless total hip arthroplasties (THAs) using an Al-on-X-linked PE bearing and to determine the rates of osteolysis using radiographs and computer tomographic (CT) scans in young patients with osteonecrosis of femoral head.

Methods

Consecutive primary cementless THAs using Al-on-X-linked PE bearing were performed in 71 patients (73 hips) who were younger than 50 years of age with osteonecrosis of the femoral head. There were 48 men (51 hips) and 23 women (23 hips). The average age at the time of the index arthroplasty was 46 years (range, 20 to 50 years). Osteolysis was evaluated using radiographs and CT scanning. The average follow-up was 11 years (range, 10 to 13 years).

Results

The mean preoperative Harris hip score was 51 points (range, 27 to 55 points), which was improved to 96 points (range, 85 to 100 points) at the final follow-up. Preoperative functional activity was improved significantly (p=0.001) at the latest follow-up. All acetabular and femoral components were fixed by bone ingrown. The mean polyethylene linear penetration was 0.05 ?0.02 mm per year (range, 0.02 mm to 0.08 mm per year). Radiographic and CT scan evaluation demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up.

Conclusion

The current generation of anatomic tapered cementless femoral component with Al-on-X-linked PE bearing is functioning well with no osteolysis at a 10-year minimum and average of 11-year follow-up in this series of young patients with osteonecrosis of the femoral head.