header advert
Results 1 - 20 of 53
Results per page:
Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims. Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results. Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion. While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article: Bone Jt Open 2022;3(6):495–501


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 100 - 102
1 Nov 2012
Vasarhelyi EM MacDonald SJ

Obesity is an epidemic across both the developed and developing nations that is possibly the most important current public health factor affecting the morbidity and mortality of the global population. Obese patients have the potential to pose several challenges for arthroplasty surgeons from the standpoint of the influence obesity has on osteoarthritic symptoms, their peri-operative medical management, the increased intra-operative technical demands on the surgeon, the intra- and post-operative complications, the long term outcomes of total hip and knee arthroplasty. Also, there is no consensus on the role the arthroplasty surgeon should have in facilitating weight loss for these patients, nor whether obesity should affect the access to arthroplasty procedures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 72 - 72
1 Oct 2020
Howard JL Williams HA Lanting BA Teeter MG
Full Access

Background. In recent years, the use of modern cementless implants in total knee arthroplasty has been increasing in popularity. These implants take advantage of new technologies such as additive manufacturing and potentially provide a promising alternative to cemented implant designs. The purpose of this study was to compare implant migration and tibiofemoral contact kinematics of a cementless primary total knee arthroplasty (TKA) implanted using either a gap balancing (GB) or measured resection (MR) surgical technique. Methods. Thirty-nine patients undergoing unilateral TKA were recruited and assigned based on surgeon referral to an arthroplasty surgeon who utilizes either a GB (n = 19) or a MR (n = 20) surgical technique. All patients received an identical fixed-bearing, cruciate-retaining beaded peri-apatite coated cementless femoral component and a pegged highly porous cementless tibial baseplate with a condylar stabilizing tibial insert. Patients underwent a baseline radiostereometric analysis (RSA) exam at two weeks post-operation, with follow-up visits at six weeks, three months, six months, and one year post-operation. Migration including maximum total point motion (MTPM) of the femoral and tibial components was calculated over time. At the one year visit patients also underwent a kinematic exam using the RSA system. Results. Mean MTPM of the tibial component at one year post-operation was not different (mean difference = 0.09 mm, p = 0.980) between the GB group (0.85 ± 0.37 mm) and the MR group (0.94 ± 0.41 mm). Femoral component MTPM at one year post-operation was also not different (mean difference = 0.27 mm, p = 0.463) between the GB group (0.62 ± 0.34 mm) and the MR group (0.89 ± 0.44 mm). Both groups displayed a lateral pivot pattern with similar frequencies of condylar separation. Conclusion. There was no difference in implant migration and kinematics of a single-radius, cruciate retaining cementless TKA performed using a GB or MR surgical technique. The magnitude of migration suggests there is no risk of early loosening. The results provide support for the use of a cementless TKA as a viable alternative to cemented fixation


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 98 - 103
1 Jul 2019
Premkumar A Lovecchio FC Stepan JG Sculco PK Jerabek SA Gonzalez Della Valle A Mayman DJ Pearle AD Alexiades MM Albert TJ Cross MB Haas SB

Aims. The aim of this study was to determine the general postoperative opioid consumption and rate of appropriate disposal of excess opioid prescriptions in patients undergoing primary unilateral total knee arthroplasty (TKA). Patients and Methods. In total, 112 patients undergoing surgery with one of eight arthroplasty surgeons at a single specialty hospital were prospectively enrolled. Three patients were excluded for undergoing secondary procedures within six weeks. Daily pain levels and opioid consumption, quantity, and disposal patterns for leftover medications were collected for six weeks following surgery using a text-messaging platform. Results. Overall, 103 of 109 patients (94.5%) completed the daily short message service (SMS) surveys. The mean oral morphine equivalents (OME) consumed during the six weeks post-surgery were 639.6 mg (. sd. 323.7; 20 to 1616) corresponding to 85.3 tablets of 5 mg oxycodone per patient. A total of 66 patients (64.1%) had stopped taking opioids within six weeks of surgery and had the mean equivalent of 18 oxycodone 5 mg tablets remaining. Only 17 patients (25.7%) appropriately disposed of leftover medications. Conclusion. These prospectively collected data provide a benchmark for general opioid consumption after uncomplicated primary unilateral TKA. Many patients are prescribed more opioids than they require, and leftover medication is infrequently disposed of appropriately, which increases the risk for illicit diversion. Cite this article: Bone Joint J 2019;101-B(7 Supple C):98–103


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 4 - 4
1 Oct 2019
Lawrie CM Okafor LC Kazarian GS Barrack TN Barrack RL Nunley RM
Full Access

Background. The purpose of this study was to assess the overall clinical and radiographic outcomes of unicompartmental knee arthroplasty (UKA) in the 2–10 year postoperative period. The secondary goal was to compare outcomes between fixed- (FB) and mobile-bearing (MB) implant designs. Methods. We performed a retrospective analysis of 237 consecutive primary medial UKAs from a single academic center. All cases were performed by high-volume fellowship-trained arthroplasty surgeons, though UKA comprised <10% of their overall knee arthroplasty practice (<20 medial UKAs per surgeon per year). Clinical outcomes included the Oxford Knee Scores (OKS) and revision rates. Femoral and tibial coronal and sagittal angles (FCA, FSA, TCA, TSA) were radiographically measured. FCA (>±10º deviation from the neutral axis), FSA (>15º flexion), TCA (>±5º deviation from the neutral axis), and TSA (>±5º deviation from 7º) outliers were defined. Far outliers were defined as measurements that fell an additional >±2º outside of these ranges. Outcomes were compared between the FB and MB groups. Results. Overall, OKS scores improved significantly from 18.6 to 34.2 (p<0.0001) following UKA. The overall revision rate at an average 5.5-year follow-up was 14.3%. Only 48.9% and 46.4% of knees simultaneously fell within coronal and sagittal alignment targets for femoral and tibial alignment, respectively. Only 24.1% of all UKAs fell within target alignment in all four measurements. When comparing FB and MB knees, there was no difference in the overall revision rate (12.5% vs. 17.6%, p=0.280), nor were there differences in postoperative OKS (33.6 vs. 35.4, p=0.239) or outlier risk. Conclusions. The proportion of UKA revisions and alignment outliers is greater than expected, even among high-volume surgeons. In general, implant design does not appear to significantly impact clinical outcomes, revision rates, or implant alignment. There was a trend for far outliers to have a higher rate of revision and lower OKS. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 61 - 61
1 Oct 2019
Warth LC Deckard ER Meneghini RM
Full Access

Introduction. t is accepted dogma in total knee arthroplasty (TKA) that resecting the posterior cruciate ligament (PCL) increases the flexion space by approximately 4mm, which significantly affects intra-operative decisions and surgical techniques. Unfortunately, this doctrine is based on historical cadaveric studies of limited size. This study purpose was to more accurately determine the effect of PCL resection on the tibiofemoral flexion gap dimension in vivo in a large sample. Methods. Tibiofemoral joint space measurements were made during 127 standardized TKAs by two arthroplasty surgeons. A medial parapatellar approach, computer navigation and provisional tibial and femoral bone cuts were performed in all cases with particular attention to preserving PCL integrity. Cases with an incompetent or damaged PCL were excluded. The tibiofemoral gap dimension was measured with a calibrated tension device at full extension, 45-degrees, and 90-degrees before and after complete PCL resection. Results. 52% of patients were female (66/127), with mean age and BMI of 69.4 years and 34.3 kg/m. 2. , respectively. After PCL resection, the mean joint space dimension increased 0.3mm (range, 0–3mm) at extension, 0.9mm (range, 0–4mm) at 45-degrees, and 1.7mm (range, 0–5mm) at 90-degrees (p<0.001). The 90-degree flexion space opened ≤1mm in 48% of patients and ≥3mm in only 10%. Dividing the flexion gap change by the femoral implant dimension to account and calibrate for patient size, the joint space at 90-degrees increased more in females (0.031 vs. 0.023, p=0.022). Conclusion. The tibiofemoral joint space increases progressively from extension, to mid-flexion through 90-degrees flexion after PCL resection, yet is substantially less than reported in historical studies. However, large variation in the degree of flexion space opening was observed with some patients failing to increase their flexion space whatsoever with PCL resection. This runs counter to conventional TKA understanding and should be considered in modern surgical techniques and education. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 11 - 11
1 Oct 2018
Klement MR Luzzi AJ Siddiqi A Valichka K Sharkey PF
Full Access

Introduction. Recovery after total knee arthroplasty (TKA) may take longer than patients expect. Furthermore, there are a subset of patients who still experience pain and dissatisfaction despite normal physical examination, radiographs, and laboratory analysis. Corticosteroid injection (CSI) is commonly used nonsurgical treatment for painful knee arthritis. However, the efficacy of CSI in patients with a painful TKA remains unknown. Methods. A retrospective charge review was performed to identify a cohort of patients who had a primary TKA performed between 2015 and 2016 and later received a CSI. All TKAs and CSIs were performed by a fellowship-trained arthroplasty surgeon. Patients receiving a CSI underwent a clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to injection. Patient variables were recorded and a survey assessed the efficacy of the injection. The survey response rate was 63.6%. Results. Of the 119 responders, 81.5% remembered the injection. The average time from index arthroplasty injection was 16.9 months (range 1–133) and patients received 1.3 averaged CSIs (range 1–4). Overall, 77.3% reported decreased pain, 54.6% reported increased motion, and 60.8% reported decreased swelling. The relief lasted greater than three months for 53.6% of patients, and 84.6% reported improvement (slight to great) in the knee. The rate of patient reported adverse events was 5.0% and included pruritus, pain, decreased energy, swelling, and clicking. No patients developed PJI as a result of the injection. Conclusions. The results of this survey suggest that patients with a painful and/or swollen TKA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out recognizable etiologies (i.e. infection, loosening, instability). This study certainly has its limitations but it is the only study of its kind. The authors hope that this provides impetus for further research regarding this investigation


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1086 - 1093
1 Oct 2023
Kolin DA Sculco PK Gonzalez Della Valle A Rodriguez JA Ast MP Chalmers BP

Aims

Blood transfusion and postoperative anaemia are complications of total knee arthroplasty (TKA) that are associated with substantial healthcare costs, morbidity, and mortality. There are few data from large datasets on the risk factors for these complications.

Methods

We retrospectively reviewed the records of TKA patients from a single tertiary care institution from February 2016 to December 2020. There were a total of 14,901 patients in this cohort with a mean age of 67.9 years (SD 9.2), and 5,575 patients (37.4%) were male. Outcomes included perioperative blood transfusion and postoperative anaemia, defined a priori as haemoglobin level < 10 g/dl measured on the first day postoperatively. In order to establish a preoperative haemoglobin cutoff, we investigated a preoperative haemoglobin level that would limit transfusion likelihood to ≤ 1% (13 g/dl) and postoperative anaemia likelihood to 4.1%. Risk factors were assessed through multivariable Poisson regression modelling with robust error variance.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims

A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis.

Methods

Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 65 - 65
1 Oct 2018
Haas SB Premkumar A Lovecchio FC Stepan JG Koch CN Carroll KM Sculco PK Jerabek SA Della Valle AG Mayman DJ Pearle AD Alexiades MM Albert TJ Cross MB
Full Access

Introduction. Over the past few decades, opioid abuse has become a major threat to public health. In 2013 alone, enough opioid prescriptions were written in the United States for every American adult to have their own bottle of pills. Since then, opioid prescribing rates and opioid related deaths have continued to grow, with over 46 people dying on average each day from prescription opioid overdoses in 2016. Orthopaedic surgeons are among the top 5 specialties in the number of opioid prescriptions written. For many common surgeries, such as total knee arthroplasty (TKA), post-discharge prescriptions are based on prescriber habits and opinion. There exists limited data-driven protocols to guide post-operative opioid prescribing practices. The purpose of this prospective study was to determine the average postoperative opioid consumption in patients undergoing primary TKA using a novel mobile text messaging platform. We hypothesized that majority of patients undergoing TKA do not properly dispose of left over pills after surgery. Methods. 95 patients undergoing primary unilateral TKA with one of nine arthroplasty surgeons at a single orthopaedic specialty hospital were prospectively enrolled. Daily pain levels and opioid consumption, and quantity and disposal patterns for left over medications were collected for six weeks following surgery using a novel mobile phone text messaging system. This system automatically queried patients twice a day, storing responses on a secure third-party host that investigators monitored and used to generate data reports in real-time. Results. Of the 95 patients enrolled, 1 was excluded for undergoing a secondary procedure in the acute postoperative data collection period. Of the remaining 94 patients, 88 (93.6%) completed the daily SMS surveys and were included in analysis. Average age was 62.0 ± 7.1 years, BMI 31.1 ± 6.2, and length of hospital stay 2.6 ± 1.2 days. The average oral morphine equivalents (OME) consumed during the 6 weeks post-surgery were 617.3 ± 350.26 mg, which corresponds to a mean consumption of 82 oxycodone 5 mg tablets per patient. For the 55(58.5%) of patients who had stopped taking opioids within 6 weeks of surgery, there were on average 196.2 mg OME left over, the equivalent of 26 oxycodone 5 mg tablets; 20% of those who stopped taking opioids had at least 367.5 mg OME left over, the equivalent of at least 49 oxycodone 5 mg tablets. Only 26.5% of patients with left over pills described an appropriate method of disposal of left over medications, with most patients storing left over pills in their homes. Conclusion. This prospectively collected data provides a benchmark for average opioid consumption after uncomplicated primary unilateral TKA. Many patients are prescribed more opioids than they require, and left-over medication is infrequently disposed of appropriately, which increases the risk for illicit diversion. Prospective collection of patient reported opioid consumption has tremendous value in the development of national postoperative guideline protocols while informing further research and strategies aimed to reduce opioid use and misuse and in predicting patient characteristics associated with increased opioid consumption after surgery


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 29 - 29
1 Oct 2018
Lawrie CM Schwabe M Pierce A Barrack RL
Full Access

Introduction. Cemented total knee arthroplasty (TKA) remains the gold standard with survivorship above 90% at greater than 10 years postoperatively. However, with younger, heavier, more active patients undergoing TKA at an increasing rate, cementless implants have the appeal of potential for improved implant fixation longevity and decreased rates of aseptic loosening. The cementless implants are more expensive than their cemented counterparts such that implant costs may create a barrier to utilization. However, such comparisons fail to consider the unavoidable additional costs of cementing, including the cost of operating room time, cement and cementing accessories. The purpose of this study is to compare the actual cost of cemented and cementless TKA. Methods. The TKA cost calculation included the cost of operative time, implants, cement and cementing accessories. The difference in operative time between cemented and cementless TKA was determined from a previously published study of 100 TKAs performed using a cemented (55) or press fit (45) implant of the same design performed at a single institution by four fellowship trained arthroplasty surgeons. The decision to use cemented or cementless design in these patients was made based on patient bone quality intraoperatively. Operative time was compared between groups using a Student's two-tailed T-test. The cost of operating room time was based on estimates in the recent literature. The cost of cement and cementing accessories was estimated based on publically available market data. The cost of implants was estimated from institutional data for multiple companies. Results. The cost comparison between cemented and cementless total knee arthroplasty is summarized in Table 1. Mean operative time for cemented TKA was 14.3 minutes longer than for cementless TKA (94.7 + 15.2 vs. 80.4 + 15.7, p<0.01). The estimated cost of one minute of operating room time in the literature ranges from $30 to $60. For our analysis, we used an estimate of $36 per minute obtained from a recently published multi-center study. This resulted in an average operating room time cost $3406 for cemented and $2894 for cementless TKA. Antibiotic cement costs an average of $250 per bag and antibiotic-free cement costs an average of $75 per bag. Cement mixing techniques vary across surgeons. Approximately 95% use a vacuum system and 5% use a mixing bowl. The cost of vacuum systems ranges from $80 for an enclosed bowl to $125 for a vacuum system that can be directly connected to a cement gun. The cost of a plastic mixing bowl and spatula is $20. The cost of the disposables from a cement injection kit is $25. The average cost of a primary TKA implant, including femoral, tibial and polyethylene liner components, is $3530 for cemented and $4659 for cementless designs. Patellar resurfacing is not routinely used at our institution and therefore was not included in implant cost. Based on our calculations, the average cost of a cementless TKA is $7553. Using the cheapest cementing technique with 2 bags of plain cement and a manual mixing bowl with spatula, the cost of a cemented TKA $7114. Using the most expensive cementing technique with 2 bags of antibiotic cement and a cement gun compatible vacuum mixer, the cost of a cemented TKA is $7564. Conclusion. Cemented TKA remains the gold standard and still accounts for most procedures. Cementless TKA is increasing in utilization and may decrease the rate of aseptic loosening, especially in the rapidly growing young, active population undergoing TKA. Although cementless implants remain more expensive than cemented implants at most institutions, the actual overall cost of the two procedures is similar if operative time, cement and cementing accessories are considered. For any figures or tables, please contact authors directly


Aims

The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness.

Methods

A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims

Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort.

Methods

Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 432 - 441
5 Jun 2023
Kahlenberg CA Berube EE Xiang W Manzi JE Jahandar H Chalmers BP Cross MB Mayman DJ Wright TM Westrich GH Imhauser CW Sculco PK

Aims

Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model.

Methods

We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims

The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?

Methods

A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 158 - 165
1 Feb 2024
Nasser AAHH Sidhu M Prakash R Mahmood A

Aims

Periprosthetic fractures (PPFs) around the knee are challenging injuries. This study aims to describe the characteristics of knee PPFs and the impact of patient demographics, fracture types, and management modalities on in-hospital mortality.

Methods

Using a multicentre study design, independent of registry data, we included adult patients sustaining a PPF around a knee arthroplasty between 1 January 2010 and 31 December 2019. Univariate, then multivariable, logistic regression analyses were performed to study the impact of patient, fracture, and treatment on mortality.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 961 - 970
1 Sep 2023
Clement ND Galloway S Baron YJ Smith K Weir DJ Deehan DJ

Aims

The primary aim was to assess whether robotic total knee arthroplasty (rTKA) had a greater early knee-specific outcome when compared to manual TKA (mTKA). Secondary aims were to assess whether rTKA was associated with improved expectation fulfilment, health-related quality of life (HRQoL), and patient satisfaction when compared to mTKA.

Methods

A randomized controlled trial was undertaken, and patients were randomized to either mTKA or rTKA. The primary objective was functional improvement at six months. Overall, 100 patients were randomized, 50 to each group, of whom 46 rTKA and 41 mTKA patients were available for review at six months following surgery. There were no differences between the two groups.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 604 - 612
1 May 2022
MacDessi SJ Wood JA Diwan A Harris IA

Aims

Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA.

Methods

A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS4) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 173 - 181
1 Mar 2022
Sobol KR Fram BR Strony JT Brown SA

Aims

Endoprosthetic reconstruction with a distal femoral arthroplasty (DFA) can be used to treat distal femoral bone loss from oncological and non-oncological causes. This study reports the short-term implant survivorship, complications, and risk factors for patients who underwent DFA for non-neoplastic indications.

Methods

We performed a retrospective review of 75 patients from a single institution who underwent DFA for non-neoplastic indications, including aseptic loosening or mechanical failure of a previous prosthesis (n = 25), periprosthetic joint infection (PJI) (n = 23), and native or periprosthetic distal femur fracture or nonunion (n = 27). Patients with less than 24 months’ follow-up were excluded. We collected patient demographic data, complications, and reoperations. Reoperation for implant failure was used to calculate implant survivorship.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 71 - 71
1 Jul 2012
Beard D Holt M Mullins M Massa E Malek S Price A
Full Access

Purpose. Late stage medial unicompartmental osteoarthritic disease of the knee can be treated by either Total Knee Replacement (TKR) or Unicompartmental Replacement (UKR). As a precursor to the TOPKAT study this work tested the postulate that individual surgeons show high variation in the choice of treatment for individual patients. Method. Four surgeons representing four different levels of expertise or familiarity with partial knee replacement (UKR design centre knee surgeon, specialist knee surgeon, arthroplasty surgeon and a year six trainee) made a forced choice decision of whether they would perform a TKR or UKR based on the same pre-operative radiographic and clinical data in 140 individual patients. Consistency of decision was also evaluated for each surgeon 3 months later and the effect of additional clinical data was also evaluated. The sample consisted of the 100 patients who had subsequently undergone UKR and 40 who had undergone TKR. Results. The specialist knee surgeon from the design centre would have performed UKR in 80% of the patients. The other surgeons would have performed a UKR in between 32-43% of the patients representing a variation in decision making of up to 59%. The choice of treatment for each surgeon remained unchanged in between 80-87% of cases after viewing additional clinical data. There was high intra surgeon repeatability in decision making when assessed 3 months later. Conclusion. Despite being given identical information, surgeons show high variability in decision making for patients with medial OA of the knee. A knee surgeon with a special interest in partial knee replacement is twice as likely to choose UKR for a patient with medial compartment OA than a non specialist surgeon. The choice is predominantly based on radiological findings but decision making for each individual surgeon is reassuringly consistent. The implications are that if TKR and UKR have unequal efficacy, some patients may be undergoing a suboptimal procedure